select 3D ® and select 3D ® ii<br />

ArtEriAl CAnnulAE<br />

lAsEr DOPPlEr AnEmOmEtry<br />

(lDA) PErFOrmAnCE †<br />

laser doppler anemometry testing demonstrates that<br />

the select <strong>3D®</strong> arterial cannula features significantly<br />

reduced velocity compared to a standard open<br />

tip arterial cannula while also maintaining a more<br />

centralized flow pattern compared to competitive<br />

diffuse flow arterial cannulae.<br />

Comparison of flow velocity for 24 Fr arterial cannulae<br />

at 6 lPm. velocity measurements at 12mm from<br />

cannula tip for the select 3D (diffuse flow), a standard<br />

open tip angled (non-diffuse flow), terumo®-sarns<br />

angled soft-Flow® (diffuse flow).<br />

<strong>Medtronic</strong>-DLP 78624 – 24 Fr<br />

<strong>Medtronic</strong>-DLP 72524 – 24 Fr<br />

Terumo ® -Sarns Soft-Flow - 5768 – 24 Fr - 8 mm<br />

† Data on file at medtronic, inc.<br />

FlOw PErFOrmAnCE<br />

COmPArisOn<br />

Select 3D and Select 3D II Arterial Cannulae<br />

Pressure Loss (mm Hg)<br />

100<br />

80<br />

60<br />

40<br />

20<br />

18 FR<br />

20 FR<br />

22 FR<br />

24 FR<br />

0<br />

0 1 2 3 4<br />

Flow Rate (L/min. of water)<br />

5 6<br />

the unique design of the 3D arterial cannulae<br />

tip results in lower arterial line pressures than<br />

a conventional open tip arterial cannula or<br />

competitive diffuse flow arterial cannula.<br />

Line Pressure (mm of Hg)<br />

Average Line Pressure – 24 Fr Arterial Cannulae<br />

Average Line Pressure – 24 Fr Arterial Cannula<br />

(Closed Circuit Using Blood)<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

112.20<br />

Select 3D<br />

24 Fr Angled<br />

(<strong>Medtronic</strong>-<br />

DLP 78624)<br />

(Closed Circuit Using Blood)<br />

127.73<br />

Open Tip<br />

24 Fr Curved<br />

(<strong>Medtronic</strong>-<br />

DLP 83024)<br />

156.47<br />

Soft-�ow®<br />

24 Fr Angled<br />

Terumo®-Sarns<br />

5768<br />

laboratory comparison of arterial line pressures at 6 liters<br />

per minute*<br />

*Data on file at medtronic, inc.