ENGLISH <strong>SERVICE</strong> <strong>MANUAL</strong>DETERGENT SUPPLY SYSTEMTROUBLESHOOTINGSmall amount of solution or no solution reaches the brushPossible causes:1. The solution tank valve is clogged/dirty or broken (clean or replace).2. The solenoid valve (EV) is broken or there is an open in the electrical connection (replace the solenoid valve/repair theelectrical connection).3. There is debris in the solution tank clogging the output hole (clean the tank).4. There is debris in the solution hoses and/or reducer clogging the flow (clean the hose).The solution reaches the brush also when the machine is offPossible causes:1. There is dirt or calcium deposit on the solenoid valve gasket (clean).2. The solenoid valve is broken (replace).WIRING DIAGRAMP10042112 9098840000 SC350