Beta Star<strong>Radial</strong> <strong>Arm</strong> <strong>Door</strong>Steam SterilizationAutoclave<strong>Sterilizer</strong> Models:243636, 243648, 243660Features and BenefitsLowest Cost of Ownership - Design characteristics from yearsof service experience are engineered into the LS Seriessterilizers. Industrial grade components, precision machiningand fabrication, proven mechanical advantages and utilityconservation devices provide owners and users with a lowmaintenance reliable sterilizer.Reliability - Industrial grade components and high temperaturedoor gaskets greatly reduce costly and common service downtime.The vessel is tested and certified to exceed national pressurevessel standards and carries a manufacturer’s warranty.Safety - Operator and technician safety is ensured throughtemperature and pressure monitoring, relief valves, safetyinterlocks and overrides.Serviceability - Reduce costly maintenance downtime with easyto access consumable and expendable components.Simplicity - The intuitive touch screen interface provides userswith clearly identifiable selections to operate cycles.Long Life <strong>Door</strong> Gasket - Beta Star’s high temperature, airactuated door gaskets are seated into a machined groovethat provides a close tolerance creating a less strenuousenvironment, extending door gasket life.Made in the U.S.A. - Manufactured in southeastern Pennsylvania,Beta Star takes pride in their first class ASME certified fabricationand assembly plant. Over 250 employees are committed to thesuperior quality products we provide.Eco Friendly - Reduce your facility’s water footprint with BetaStar’s utility conservation features. Mechanical and programmableconservation features are integrated into the Beta Star LS Seriessterilizer.ApplicationBeta Star supplies sterilization cycle packages for all applicationsin the pharmaceutical, life science, biotechnology, laboratory,and animal care markets. All LS Series sterilizers includePre-Vacuum, Liquid, Bio-Bag, Hard Goods, Bowie-Dick and aVacuum Leak Test cycle as standard. Cycle parameters adhereto the guidelines for Industrial Moist Heat Sterilization referred toin document AAMI / ISO 111345-R-8/93.Thirty total cycle recipes can be programmed and stored for specificproducts using supervisory access. Custom cycle programming issupported by an all encompassing PLC system.DesignBeta Star sterilizers are value engineered for maximumthroughput, efficiency, serviceability, safety, and reliability. Oursolid stainless steel rectangular chambers offer dual steaminlet baffles for better temperature distribution, more usablespace, center sloping chamber floors to minimize condensateretention, reduce dry time, and allow simple cleanup if spillingoccurs.Beta Star steam sterilizers are designed for continuous use withserviceability engineered into every sterilizer. Lengthy downtimehas been eliminated through the use of industrial grade nonproprietarycomponents. Our rigid modular frame provides a solidbase and framework for easy access to our industrial grademechanical and electrical components.R-V <strong>Industries</strong>, Inc. Honey Brook, PA • website: www.rvii.com


<strong>Sterilizer</strong> Cycles<strong>Radial</strong> <strong>Arm</strong> <strong>Door</strong> SeriesPRE-VACUUMCONDITIONING STERILIZE EXHAUSTCHAMBER TEMPERATURE121 0GRAVITY CYCLECONDITIONING STERILIZE EXHAUSTCHAMBER TEMPERATURE20.0PSIA121 0 CHAMBER PRESSUREAMBIENT PRESSURE20.0PSIACHAMBER PRESSUREAMBIENT PRESSURETIMETIMELEAK TESTLIQUID CYCLECONDITIONINGHOLD TIMEEXHAUST121 0CONDITIONING STERILIZE SLOW EXHAUSTCHAMBER TEMPERATURE15.0PSIAAMBIENT PRESSURE0.0PSIATIMECHAMBER PRESSURE20.0PSIACHAMBER PRESSUREAMBIENT PRESSURETIMEPre-Vacuum CyclesPre-Vacuum Cycle - pre-conditioning of load during air removalusing programmable ramped positive and negative pressurepulsing to remove entrapped air. Programmable ramped vacuumdrying.Micro Isolator Cycle - pre-vacuum cycle using programmable,ramped, positive and negative pressure pulsing to reduce internaland external crazing of animal housing by allowing pressurestabilization to product items being processed.Test CyclesLeak Test - programmable vacuum leak test to verify door seal,sterilizer chamber and piping integrity through monitoring ofacceptable vacuum loss over selected time.A.A.R.T. (autoclave air removal test) - pre-programmed vacuumcycle used to verify removal of residual air from chamber and load,and ensure steam penetration into the test load.Bio-Waste Cycle - designed for pre-sterilization conditioningthrough positive and negative pressurization to ensure air removalfrom mixed products in containers. Programmable ramped steampressurization is used to maximize heat penetration of mixedlaboratory biohazard waste.F 0Temperature Control Cycle - for the sterilization of heatsensitive materials using time-at-temperature calculationsbeginning at a predetermined point of the conditioning phase.This reduces the product exposure to higher temperaturesnormally found in standard sterilization cycles.Gravity Cycle - for non-air retentive products; utilizes positivesteam pressure with vacuum assist air removal for conditioningof load. The end of cycle exhaust is programmable for dry andnon-dry phases.Liquid CyclesLiquid Cycle - cycle used for liquids in vented borosilicate glassor metal containers. Positive steam pressure with vacuum assistedair removal with programmable ramped heating and exhaust toambient with optional cooling phase.Liquid, Air Cool Cycle - cycle used for liquids in ventedborosilicate glass or metal containers. Positive steam pressurewith vacuum assisted air removal with programmable rampedheating and introduction of filtered air during exhuast to speedcooling.Pre-Vacuum Liquid Cycle - pre-conditioning of load usingprogrammable, ramped, positive and negative pressure pulsingto assist in removal of entrapped air. Chamber temperatures atnegative pressures are controlled to prevent boiling of product.Controlled ramped exhaust to ambient with optional cooling phase.Isothermal Cycle - designed for conditioning of heat sensitivematerials at a temperature range of 78 O C - 104 O C.Effluent - for the processing of items in BSL3 and BSL4 laboratories.The cycle uses a heated, jacketed, 0.2 micron hydrophobic filterto contain biohazard contents in sterilizer chamber while allowingexhaust of sterile gasses.R-V <strong>Industries</strong>, Inc. Honey Brook, PA • website: www.rvii.com


Standard Equipment<strong>Radial</strong> <strong>Arm</strong> <strong>Door</strong> SeriesControl SystemThe Laboratory Series (LS) Color Touch Screen PLC featuresa user friendly interface powered by a robust ProgrammableLogic Control system. Features include:• Operator intuitive 5.7” color touchscreen display• Five (5) levels of user login security• Pre-programmed cycle types• Thirty (30) stored programmablecustom cycles• Custom cycle names for easyrecognition• Continuous cycle status output• Help screens / alarms• Network or data download portsPrinterThe printer is a 32 column, nine (9) pin dot matrix impact printer.The printer records all cycle set points, cycle phase changes,pressure and temperature at specified time intervals and alarms.The printer uses easy to change roll paper and ink ribbons.Vessel ConstructionAll Beta Star vessels are manufactured at our corporateheadquarters in Honey Brook, PA. All standard vessels consistof a 316L stainless steel chamber and door and 304 stainlesssteel steam jacket. The chamber and jacket meet the requirementsof the ASME Boiler and Pressure Vessel Code Section VIII,Division 1. The vessel chamber, door(s) and jacket maintain specifiedoperating pressures and temperatures and withstand operationfrom full vacuum to 45 psig. Two (2) validation ports for loadprobes are included on all sterilizer chambers. Features include:• Engineered for optimum life expectancy• 316L/304 stainless steel construction• 25 Ra polished chamber finish for sanitary requirements• Two (2) threaded validation ports for load monitoring• Machined and polished door gasket groove for extendeddoor gasket life, and greater assurance of seal integrity• Rectangle chamber design for maximum loading capacity• Three (3) sided door retention for additional safety• Dual steam inlet for uniform temperature distributionPipingAll piping assemblies are constructed, tested and fitted usingbrass and copper connected to the jacket, chamber and drain.Industrial grade pneumatic valves provide less maintenance,eliminating costly downtime. Features include:• Engineered for lowest cost of ownership• High temperature industrial grade valves• Pressure relief valves• Piping designed to reduce condensation and ease of maintenance• Serviceable piping configuration for P.M. inspections• Integrated RTD’s for constant and accurate monitoring• Easy-Clean chamber drain strainer• Stainless steel piping configurations are available<strong>Door</strong> SystemThe <strong>Radial</strong> <strong>Arm</strong> Swing <strong>Door</strong> is a less than one quarter turn, easyoperation, manual hinged radial arm door with safety interlock andpositive mechanical lock. The radial door system features foursided door retention certified by ASME code.Engineered for safety: eachdoor system is equipped withboth automatic locking andsealing subsystems. Thelocking system is used toensure that once the autoclavebegins a cycle, the doorgasket remains locked untilthe system has reached a safeto open state. We also havea door seal test system thatmust be satisfied prior to allowing steam into the chamber. Thesealing system uses compressed air to activate the sealonce the door is closed and locked.<strong>Door</strong> GasketBeta Star’s high temperature, air actuated door gaskets are seatedinto a machined groove that provides close tolerances, offering aless strenuous operating environment, extending door gasket life.FasciaAll Beta Star sterilizers include a number 4 finish, 304 stainlesssteel, removable front fascia panel to enclose the vessel,mechanicals and the door. Side, back and top panel removableenclosures are available.Vacuum SystemThe Beta Star LS series sterilizer is equipped with a water ejectorsystem. Beta Star’s unique piping configuration reduces waterconsumption while maintaining consistent vacuum and automaticallyregulating effluent temperature to the facility drain to belowlocally specified temperature requirements.Quality StandardsAll sterilizers are rigorously tested according to Beta Star QAand testing procedures. The results of each test are recorded andstored on the Quality Control Record (QR-001). This testingincludes: instrument calibration to NIST standards, electricalinput and output verification, Leak Test, Bowie & Dick Test, alarmsverification, hazards test and consecutive execution of sterilizationcycles to insure repeatability. Temperature control to within +/-0.5°C is verified for all sterilization cycles. The following listingsand standards are met, exceeded and carry identifiable labeling.• Underwriters Laboratory (UL) Standard• ASME Code, Section VIII, Division 1 for pressure vessels.• Canadian Standards Association (CSA)Safety FeaturesBeta Star sterilizers are safe to operate. They all contain safetychecks and balances that ensure operator safety.• An auto abort system for abnormal chamber conditions• An interlocking door that will stay closed under chamber pressure• Key lock system that ensures only authorized users haveaccess to the sterilizer• A pneumatic override of steam to chamber valve• Safety door handle that will bend but not break if too muchoperator pressure is applied when the door is lockedR-V <strong>Industries</strong>, Inc. Honey Brook, PA • website: www.rvii.com


Equipment Options<strong>Radial</strong> <strong>Arm</strong> <strong>Door</strong> SeriesControl System OptionsThe Beta Star LS Touch Screen control system is equipped tohandle advanced cycle functionality.• F 0Cycle: The F 0Cycle calculates the sterilization time based onload temperature and duration exposed. These calculations arebased on predetermined set points. The result is controlledexposure time.• Air Over Pressure: This option provides filtered air pressureto the chamber to cool the load and controlled exhaust rate. Thisfeature is used in the processing of critical liquids to reduce thecycle time and prevent boil over.• Isothermal Cycle: This is a low temperature cycle used indisinfection or pasteurization of heat sensitive solutions.• Full or Partial Remote: <strong>Sterilizer</strong>s equipped with a second dooras a pass through can be equipped with full control capabilities orpartial control capabilities for monitoring system status.• Allen Bradley Compact Logix: An Allen Bradley non-proprietaryPLC is available with the Beta Star LS series sterilizers.• Nema 4x Enclosure: For facilities who require specific controlenclosures.• Load Probe: A load probe for temperature monitoring can beadded through one of the included validation ports.Vessel OptionsThe Beta Star vessel can be configured to enhance functionality.• Double <strong>Door</strong>: Beta Star LS <strong>Sterilizer</strong>s can be configured witha second door to be used as a pass through system. Doubledoor sterilizers can be equipped with a full or partial secondarycontrol.• Sanitary Ports: The chamber ports can be upgraded with sanitaryports accepting thermocouple fittings for use with critical mediaor goods.• 20 Ra Polish: The internal chamber and door can be polishedto a 20 Ra finish or better for critical applications.• 316L Steam Jacket: The standard 304 stainless steel steamjacket can be upgraded to 316L stainless steel.• Seismic Restraints: For equipment being installed in areas ofseismic activity, a seismic restraint or tie-down is used.• Chamber Passivation: An internal surface chamber passivationcan be applied to the sterilizer. This process removes impuritiesand inhibits further corrosion.• Dual Drain: Allows for improved temperature distribution.• Jacket Idle: Holds jacket at lower temperature for utilityconservation when the unit is not in cycle.Piping Options<strong>Sterilizer</strong> jacket and chamber piping can be configured to meetprocess requirements and are upgrades.• 316L Stainless Steel Piping with threaded and swagelockfittings, and stainless steel process valves.• Sanitary Piping: 316L stainless steel, orbital welded, sanitarypiping and process valves can be added for high level sterilization.Steam Source OptionsThe Beta Star LS Steam <strong>Sterilizer</strong>s are used for moist heatsterilization. Steam requirements vary based on model size andoptions. The following are the steam supply options:• House Steam: House steam is when the facility or building isequipped with a steam source that can supply the sterilizer withthe required steam utility.• Integral Electric Boiler: An integral electric boiler is used togenerate steam if there is no building steam available. Integralboilers sit within the footprint of the sterilizer.• Stainless Steel Boiler: For use with sensitive media or goods,a stainless steel steam generator can be used to produce cleansteam with DI water.• Steam to Steam Generator: A heat exchanging system usedto create clean steam from a pure water source and house steamor electric boiler system. These systems are connected directlyto the chamber.Air CompressorA laboratory grade air compressor can be used when facilitysupplied compressed air is not available.Process OptionsNon-standard options used in the processing of goods or mediainclude:• Air Inlet Insitu Filter: An air inlet filter rated at 0.2 um. For usein high level sterilization.• Stainless Air Inlet Housing: A stainless steel housing thatallows the insitu filter to be sterilized.Loading EquipmentA bottom shelf is standard with all Beta Star sterilizers. Additionalshelves are available using the internal rack system.Loading Cart & Transfer CarriageThe heavy duty 316L stainless steel loading cart is designed tohold the goods or media to be sterilized. The loading cart rideson the tracks between the transfer carriage and the chamber. Thetransfer carriage is used to transport the loading cart from stationto station. A drip pan can be added to the loading cart to capturespilled liquid or media.Uninterrupted Power / Backup PowerAn uninterrupted power supply (UPS) system can be integratedinto the sterilizer configuration. This option helps prevent againstvoltage spikes, drops and loss. This system works by having aninternal checking system that when power loss is recognized, asterilizer alarm goes off and the system goes into “abort”conditions which will hold the sterilizer in safe mode untilelectric service is being provided to the unit.Loading Cart & Transfer CarriageR-V <strong>Industries</strong>, Inc. Honey Brook, PA • website: www.rvii.com


Equipment Options<strong>Radial</strong> <strong>Arm</strong> <strong>Door</strong> SeriesBiocontainment SealAn optional biocontainment flange is welded to the vessel. Theflange serves as a sealed and ready-to-install rigid support for ouradaptable biocontainment extension panels, ensuring a reliable andturnkey pathogen barrier for containment applications.Effluent Package OptionOur design prevents harmful pathogens and viruses from exitingthe sterilizer at any time during the sterilization process. Pathogensare retained until the required sterilization exposure time hasbeen achieved.Our standard steam effluent sterilization cycles exhaust througha heated 0.2 um hydrophobic filter in order to prevent pathogensand viruses from exiting the sterilizer prior to fulfilling sterilizationtime and temperature requirements. Sloped chamber base andinternal liquid dams retain effluent during the entire sterilizationperiod.ServiceabilityService access will be from the top, and control side of the sterilizer.Electrical wiring, pneumatic valves and tubing is clearly labeledand visibly traceable. Standard piping components are copperbrazed or compression fittings and threaded brass components,positioned for safe and easy replacement. All wiring and piping arenon-proprietary industrial grade components available direct througha local supply house, authorized service agency, or direct throughthe Beta Star Parts Department.Quality DocumentationQuality documentation packages can be included into yoursterilizer package. Quality documents include:• IQ/OQ Documentation Only: A documentation package usedto qualify installation and operation of the sterilizer.• IQ/OQ Documentation and Execution: A documentationpackage and manufacturer representative executing andqualifying installation and operation of the sterilizer.• GMP Documentation Package: Good Manufacturers Practicedocumentation package used for sterilizers involved in themanufacturing process.• FAT (Factory Acceptance Test): Equipment testing performeddirectly by the manufacturer in the factory before shipment.• FAT Documentation Only Package: Documents qualifying thefactory acceptance test.• SAT (Site Acceptance Test): On-site testing of the equipmentperformed by a manufacturer’s representative.• FRS (Functional Requirement Specification): Testing providedensuring equipment functionality.• Chamber Temperature Mapping: Temperature testing throughoutthe inside of the chamber to record consistency.Installation ScopeAll Beta Star sterilizers are installed directly by the manufactureror an authorized installation provider. The scope of installationcan vary depending on the customer’s requirements.• Delivery: Factory direct delivery and installation provided directlyor through an authorized installation provider.• Removal of Existing Equipment: In the case of equipmentreplacement, Beta Star can arrange removal of the existingsterilizer.• Installation Supervision Only: Where in-house or specializedservice workers will be used, an on-site authorized representativewill guide workers through the installation process.• User Training: Operator training is provided with every newlyinstalled sterilizer. Additional operator training is available torefresh or train new users.• Maintenance Training: In-house maintenance technicians canbenefit from factory direct training on-site or at our factory.Preventative MaintenanceA network of trained and skilled service technicians can providescheduled inspections, adjustments, and recommendedmaintenance to ensure equipment reliability. Contact Beta StarService for maintenance agreement options.Water ConservationThe EnviroVac® dramatically reduces environmental and facilitywater usage concerns with our water savings option.Beta Star <strong>Sterilizer</strong>s can be equipped with the optional patentpending EnviroVac ® . Designed to drastically reduce waterconsumption by nearly 75% during the sterilization cycle, theEnviroVac ® requires only a ½” water feed at a minimum of 20 psig.With the EnviroVac ® option your sterilization cycle is no longer atrisk due to normal water pressure and temperature fluctuations.The EnviroVac ® also monitors and regulates water and steamdischarge to ensure they are below safe and regulatory temperaturelevels before allowing entry to the facility drain systems. Thisreplaces standard vacuum pump and condenser systems providedby others. Condensers on other systems have a history of failure,which requires costly out of warranty replacement.R-V <strong>Industries</strong>, Inc. Honey Brook, PA • website: www.rvii.com


Sizing and Volume<strong>Radial</strong> <strong>Arm</strong> <strong>Door</strong> SeriesCHAMBERWIDTHHANDLE OFFSETFASCIAWALL OPENINGLENGTH (SD)SINGLE DOORLENGTH (DD)DOUBLE DOORFASCIA WIDTHSINGLE DOORRIGHT HAND CABINETWALL OPENINGFASCIA WIDTHDOUBLE DOORLEFT HAND CABINETDOOR SWINGCLEARANCEFASCIA WIDTHFASCIAHEIGHTFRAMEHEIGHTWALLOPENINGHEIGHTFLOOR TOCHAMBERSIDE VIEW, DOUBLE DOORRECESSED ONE WALLFRONT VIEWLEFT HANDModel 243636 243648 243660Chamber Size(W x H x L) in Inches24 x 36 x 36 24 x 36 x 48 24 x 36 x 60Chamber Capacity 18 ft 3 24 ft 3 30 ft 3Chamber Width 34.5” 34.5” 34.5”Frame Height 79” 79” 79”Length (SD) 45 1/8” 57 1/8” 69 1/8”Length (DD) 45 1/8” 57 1/8” 69 1/8”Wall Opening Width 47” 47” 47”Wall Opening Height 80 3/4” 80 3/4” 80 3/4”Fascia Height 82” 82” 82”Fascia Width 49” 49” 49”Floor to Chamber 23 1/4” 23 1/4” 23 1/4”<strong>Door</strong> Swing Clearance 28 1/4” 28 1/4” 28 1/4”Overall Weight (LB)Single <strong>Door</strong> / Double <strong>Door</strong> 3,600 / 3,700 4,000 / 4,100 4,500 / 4,600Heat Emissions (BTU/HR)Front Wall / Mech. Space 3,400 / 4,500 4,100 / 5,700 4,800 / 6,900Equipment NotesR-V <strong>Industries</strong>, Inc. Honey Brook, PA • website: www.rvii.com


Utility Requirements<strong>Radial</strong> <strong>Arm</strong> <strong>Door</strong> SeriesModel 243636Plumbing Utility Supplied Connection Material Flow Rate PressureA Drain Size 3 Inch PVC/Copper Peak AverageB Compressed Air (SCFM) 1/2 Inch Copper 2 1 80-100 PSIGC Ejector Vacuum - Water (GPM) 1 Inch Copper 14 8 60-80 PSIGC EnviroVac® Vacuum - Water (GPM) 1/2 Inch Copper 3 2 40-60 PSIGD Hot Water for Generator (GPM) 1/2 Inch Copper 1 1 40-60 PSIGE House Steam (LB/HR) 1 Inch Black Iron/Brass 180 120 60-80 PSIGElectrical Utility Voltage Phase Frequency Amp Draw Disconnect Fuse SizeF Control 120 1 60 Hz 5 Wall Disconnect 20 AmpG 48 KW Steam Generator 208/480 3 60 Hz 133/58 200/100 Amp Disconnect 175/75 AmpH Steam Generator Control 120 1 60 Hz 5 Wall Disconnect 15 AmpI EnviroVac® System 208/480 3 60 Hz 7.8/3.4 30/30 Amp Disconnect 10/5 AmpJ Air Compressor 120 1 60 Hz 12 Duplex Outlet 15 AmpModel 243648Plumbing Utility Supplied Connection Material Flow Rate PressureA Drain Size 3 Inch PVC/Copper Peak AverageB Compressed Air (SCFM) 1/2 Inch Copper 2 1 80-100 PSIGC Ejector Vacuum - Water (GPM) 1 Inch Copper 14 8 60-80 PSIGC EnviroVac® Vacuum - Water (GPM) 1/2 Inch Copper 3 2 40-60 PSIGD Hot Water for Generator (GPM) 1/2 Inch Copper 1 1 40-60 PSIGE House Steam (LB/HR) 1 Inch Black Iron/Brass 215 145 60-80 PSIGElectrical Utility Voltage Phase Frequency Amp Draw Disconnect Fuse SizeF Control 120 1 60 Hz 5 Wall Disconnect 20 AmpG 60 KW Steam Generator 208/480 3 60 Hz 167/72 600/100 Amp Disconnect 225/90 AmpH Steam Generator Control 120 1 60 Hz 5 Wall Disconnect 15 AmpI EnviroVac® System 208/480 3 60 Hz 7.8/3.4 30/30 Amp Disconnect 10/5 AmpJ Air Compressor 120 1 60 Hz 12 Duplex Outlet 15 AmpModel 243660Plumbing Utility Supplied Connection Material Flow Rate PressureA Drain Size 3 Inch PVC/Copper Peak AverageB Compressed Air (SCFM) 1/2 Inch Copper 2 1 80-100 PSIGC EnviroVac® Vacuum - Water (GPM) 1/2 Inch Copper 3 2 40-60 PSIGD Hot Water for Generator (GPM) 1/2 Inch Copper 1 1 40-60 PSIGE House Steam (LB/HR) 1 Inch Black Iron/Brass 260 178 60-80 PSIGElectrical Utility Voltage Phase Frequency Amp Draw Disconnect Fuse SizeF Control 120 1 60 Hz 5 Wall Disconnect 20 AmpG 72 KW Steam Generator 208/480 3 60 Hz 200/87 600/200 Amp Disconnect 250/110AmpH Steam Generator Control 120 1 60 Hz 5 Wall Disconnect 15 AmpI EnviroVac® System 208/480 3 60 Hz 7.8/3.4 30/30 Amp Disconnect 10/5 AmpJ Air Compressor 120 1 60 Hz 12 Duplex Outlet 15 AmpNOTE: Utility “letter” key in (BOLD), indicates standard equipment utility requirements.R-V <strong>Industries</strong>, Inc. Honey Brook, PA • website: www.rvii.com


Equipment Configuration Worksheet<strong>Radial</strong> <strong>Arm</strong> <strong>Door</strong> SeriesCustomer InformationCompany:____________________________________Contact:______________________________________Address:_____________________________________Building:______________________________________City:_____________________ State:____ Zip:_______Phone:_______________________________________Email:_______________________________________Project:______________________________________Select your equipment configuration, features and optionsby using the check boxes below.* Required SelectionsModel Size*24x36x36 = 18 ft 324x36x48 = 24 ft 324x36x60 = 30 ft 3<strong>Door</strong>(s)*Single <strong>Door</strong>Double <strong>Door</strong><strong>Door</strong> Swing*Left SwingRight SwingMounting*Recessed One WallRecessed Two WallsFree Standing (Cabinet)Cabinet Fascia Panels*No Side Panels (Recessed)Two Side PanelsLeft Side PanelRight Side PanelTop PanelBack PanelService Side and Control Side*Left Side ServiceRight Side ServiceControl Options*Model LS PLC (Standard)Allen Bradley Compact LogixPartial Remote (For Double <strong>Door</strong>)Full Remote (For Double <strong>Door</strong>)Additional Printer (One Standard)Nema 4X EnclosureFoot Pedal for <strong>Door</strong>Dual RTD with RecorderPiping*Copper and Brass (Standard)316L Threaded and Swagelock316L SanitaryCompressed Air*House AirIntegral Air CompressorVacuum System Type*Water Ejector VacuumEnviroVac® Water Conservation Vacuum System(Included on model 243660)Steam Source*House SteamHouse Clean SteamIntegral Electric Boiler 208 VoltIntegral Electric Boiler 480 VoltStainless Electric Boiler 208 VoltStainless Electric Boiler 480 VoltSteam to Steam Generator (Single Tube)Steam to Steam Generator (Double Tube)Loading Equipment OptionsBottom Shelf Only (Standard)Rack with One ShelfAdditional Shelf for RackCart & Carriage OptionsLoading Cart with Two ShelvesCart Drip PanTransfer CarriageAdditional Transfer CarriageVessel & Jacket OptionsAdditional 1.5” Threaded Side PortAdditional 1.5” Sanitary Side PortPolished 20 Ra. (25 Ra. Standard)Polished 10 Ra. (25 Ra. Standard)Internal Chamber Passivation316L Steam Jacket (304 Standard)Seismic RestraintsSanitary Thermocouple FittingProcess Feature OptionsLoad Probe for F 0Air Inlet, Insitu FilterStainless Air Inlet HousingAir Over PressureContainment OptionsEffluent Decontamination Package<strong>Door</strong> 1 Bioseal<strong>Door</strong> 2 BiosealDual BiosealQuality and Documentation OptionsIQ/OQ Documentation OnlyIQ/OQ Documentation and ExecutionGMP Documentation PackageFAT (Factory Acceptance Test)FAT Documentation Only PackageSAT (Site Acceptance Test)FRS (Functional Requirement Specification)Chamber Temperature MappingInstallation Scope*Delivery and InstallationRemoval of Existing EquipmentInstallation Supervision OnlyUser TrainingMaintenance TrainingValidation SupportRiggingR-V <strong>Industries</strong>, Inc. Honey Brook, PA • website: www.rvii.comBeta Star <strong>Radial</strong> <strong>Arm</strong> <strong>Door</strong> <strong>Sterilizer</strong> • June 24, 2010