<strong>Diagnostic</strong><strong>Test</strong> <strong>Equipment</strong><strong>for</strong> <strong>Hydraulics</strong>Catalogue 4054-1/UK


<strong>Diagnostic</strong> <strong>Test</strong> <strong>Equipment</strong> <strong>for</strong> <strong>Hydraulics</strong>All the instruments meet the guidelines of the European Community (EU).It is confirmed that these products are approved acc. to following standards.DIN/ EN 61000-6-2DIN/ EN 61000-6-3Note!This document and other in<strong>for</strong>mation from Parker Hannifin GmbH & Co. KG, provideproduct or system options <strong>for</strong> further investigation by users having technical expertise.Be<strong>for</strong>e you select or use any product or system it is important that you analyse allaspects of your application and review the in<strong>for</strong>mation concerning the product orsystem in the current product catalogue. Due to the variety of operating conditions andapplications <strong>for</strong> these products or systems, the user, through his own analysis andtesting, is solely responsible <strong>for</strong> making the final selection of the products andsystems and assuring that all per<strong>for</strong>mance and safety requirements of the applicationare met. The products are subject to change by Parker Hannifin GmbH & Co. KG atany time without notice.Technical subject to change. September 2005.© Copyright 2005, Parker Hannifin Corporation. All Rights Reserved.Catalogue 4054-1/UK


ContentsPage1 ServiceJunior/ServiceJunior wireless 6-91.1 Product Specifications 61.2 Function Specifications 71.3 Technical Data 8-92 Serviceman 10-152.1 Product Specifications 102.2 Function Specifications 112.3 Technical Data 122.4 Pressure Measurement 132.5 Flow and RPM Measurement 142.6 Software 153. Service Master 16-243.1 Product Specifications 163.2 Technical Data 173.3 Function Specifications 18-203.4 Pressure Measurement 213.5 Flow and RPM Measurement 223.6 Electrical Signal Measurement 233.7 Software SensoWin ® 244 Pressure Measurement 25-284.1 Pressure Sensors 254.2 Technical Data 264.3 <strong>Diagnostic</strong> Adaptor 27-285 Temperature Measurement 29-325.1 Serviceman 305.2 Service Master 315.3 Technical Data 326 Flow Measurement 33-486.1 Flow Meter 34-376.2 Flow Turbine/Hydraulic <strong>Test</strong>er 38-436.3 Gear Flow Meter 44-487 Speed Measurement 49-507.1 Technical Data 508 Kits Serviceman/Service Master 51-529 Calibration Service 5310 Index 543 Catalogue 4054-1/UK


SensoControl ®• Long-term stability• Rugged design• Easy operation• Flexible use on site• Documentation of measured valuesSensoControl ® handmeters and complete measuringsystems are perfectly suitable measuring tools <strong>for</strong> everyapplication. Whether they are used in the industrial area,in mobile hydraulics, <strong>for</strong> service or repair: measuring andprocessing of hydraulic values is the basis of safe troubleshooting. The systematic search <strong>for</strong> errors with modernaids is something the service engineer simply cannot dowithout.High-speed processes, such as switching valves,cylinder strokes, pressure peaks, differential pressuresand flow changes must be measured and evaluatedsimultaneously.The SensoControl ® handmeters have been speciallydeveloped <strong>for</strong> the following applications:• Measurement and display of all hydraulic values,such as pressure, differential pressure, pressurepeaks, temperature and flow, as well as speed.• They are perfectly suitable <strong>for</strong> the mobile recordingof measured values and feature high precisioncombined with easy operation.All measuring devices as well as their accessories aremanufactured and tested in our own plants. Our everincreasinginsistence on quality and flexibility makeParker a reliable partner.4Catalogue 4054-1/UK


Choosing the Right ProductChoice/features ServiceJunior Serviceman Service MasterMeasuring and read outRead outACT - MIN/MAX(Peak-Hold)ACT - MIN/MAXACT - MIN/MAX2 inputs — • •3 inputs — — •4 inputs — — ◦6 inputs — — ◦Pressure peaks 10 ms 2 ms 1 msPressure • • •Differential Pressure (P1-P2) — • •Connection sensorsSocket 4 pin — • —Socket 5 pin — ◦ •Temperature/RPM/Flow — • •Electrical signals48VDC/1,5ADCExternal sensors(0/4... 20 mA)/(0...10 VDC)— — •— — •FunctionsRechargeable battery battery • •Interface — ◦ •OnLine-Function ◦ ◦ •Data recording — — •Print out graphs — — •External power supply — • •— not available◦ optional• standard5 Catalogue 4054-1/UK


1.1 ServiceJunior/ServiceJunior wireless Product Specifications• Digital pressure measurementand display• Accuracy ± 0,5 % FS• Display with bar graph(trailing indicator)with peak & hold function• Pressure peaks captured –10 ms scanning rate• Easy operation• Long-term stability• Back-lit measured value display• Pressure ports stainless steel1/4 BSPPServiceJunior Digital Pressure GaugeThe ServiceJunior makes possible the measurementand display of pressures with one instrument. Measuredvalues are shown with high precision on a 4-digit display.Pressure peaks are securely captured at a scanning rateof 10 ms.The ServiceJunior is distinctive through its very simpleoperation. With its convincing price to power ratio, theinstrument offers all the advantages of digital pressuremeasurement.With immediate effect, measurement data acquisition isentering a new dimension!Utilising the ServiceJunior wireless from Parker’sSensoControl family of products allows you tocom<strong>for</strong>tably record the pressure values taken from oneor several measurement points on your machine orinstallation. Stored measurement data is transmitted to aPC across distances of up to 50 meters.The PC software ‘JuniorWin’ allows you to set the limitvalue and the configuration to suit your needs.Thus ServiceJunior wireless allows you to save timeand costs <strong>for</strong> monitoring machines and installations– com<strong>for</strong>tably from your plant office.At the same time you can evaluate and archive the dataas well as per<strong>for</strong>m other control functions from the samePC.The device is ideal <strong>for</strong> monitoring, maintaining andservicing machines and installations in industrial andmobile hydraulic systems.6Catalogue 4054-1/UK


2.1 Serviceman Product Specifications• Easy operation• Prevention of measuring errors due toautomatic sensor recognition• Printer and PC connection• Two-line display• Rugged designThe Serviceman has 2 inputs <strong>for</strong> sensors. This enablesa differential pressure measurement by pressing only onekey. Fast comparisons of actual and set values are donevery easily.The Serviceman is extremely robust and insensitiveto dirt, so that it can be used in even the toughestconditions. The digital display avoids reading errors.The Serviceman is small and light:perfect <strong>for</strong> mobile applications.Serviceman incl. external power supply2 Inputs (5 pin) incl. PC InterfaceThe data output can be used to connect a PC.Data printout is valid under the documentationobligatory under ISO 9001.The Min/Max memory permits the reading of peakvalues. Pressure peaks which could lead to damage areavoided.Like all other SensoControl ® measuring devices, theServiceman is provided with sensor recognition. Themeasuring ranges are automatically scaled and unitsshown on the display. This avoids measuring errors andtime-consuming adjustment work.10Catalogue 4054-1/UK


2.2 Serviceman Function SpecificationsDisplayDisplay (two line)INP1 and INP2; ∆P displayBattery level displayMIN: Minumum valueOn/off switchSelect button <strong>for</strong> inputDifferential value displaye.g. P1 - P2 = ∆PData transfer to PCDelete MIN/MAX-readingsINP1 = INP2:Equalisation of ∆P-measuringMaximum value (pressure peaks)Minimum valueZero point equalisationINP1/INP224VDCRS232Sensor inputs5-pin = push pullPower supply orautomotive cable adaptorSCK-318-05-21PC interfaceSCM-152-2-02Type SCM-152-1-02 SCM-152-2-02PC interface — •Standard delivery includes SCSN-450(power supply 110/220 VAC)Accessories• •Automotive cable adaptor (24 VDC) SCK-318-05-21 • •PC-Software Kit SCSW-KIT-152 — •Spare battery SC-811 • •Charging Unit (220 VAC) <strong>for</strong> SC-811 • •— not available • serial11 Catalogue 4054-1/UK


2.4 Serviceman Pressure MeasurementINP11-2barbarPressureDifferential pressurePressurePressurePressureFlowSCK-102-03-02ServicemanSCM-152-x-02SCPT-xxx-02-02EMA3SCA-EMA-3/3SMA3-xxxPressure SensorsThere is a selection of various measuring ranges <strong>for</strong>pressure measurement. Sensors are available <strong>for</strong>pneumatic applications and also <strong>for</strong> measuring pressurepeaks up to 1000 bar.<strong>Diagnostic</strong> adaptorsAll pressure sensors in a measurement case (kit) areprovided with a factory-assembled SCA-1/2-EMA-3diagnostic adaptor. The pressure sensors can beadapted to all standard measuring connections with thehelp of diagnostic couplings supplied.They are perfectly suitable <strong>for</strong> a quick and flexiblediagnoses in hydraulic applications.13 Catalogue 4054-1/UK


2.5 Serviceman Flow and RPM MeasurementSCK102-03-02ServicemanSCM-152-x-02FLOWSCFTSCRPM-220SCFT-xxx-02-0214Catalogue 4054-1/UK


2.6 Serviceman SoftwarePC Software KitSCSW-KIT-152ServicemanSCM-152-2-02SCSN-450• Easy operation• Self running installation• On-line data recording• Storage of readings in MS Excel <strong>for</strong>mate• Analysis of data with standard software• Print out readings on siteData transfer from Serviceman to PC or laptop ispossible with the PC Software Kit.The software included is compatible withMS Windows 98/2000/XP.Recorded data can be further processed and analysedwith standard software (e.g. MS Excel).15 Catalogue 4054-1/UK


3.1 Service Master Product Specifications• Instruments with 3-channel, 4-channeland 6-channel technology• Easy operation due toautomatic sensor recognition• PC connection• Powered by rechargeable battery• Rugged designThe Service Master is a multi-channel hand meter<strong>for</strong> the simultaneous measuring of important hydraulicvalues:All hydraulic parameters such as pressure, differentialpressure, flow and hydraulic power can be measured,displayed, stored and processed.To meet the requirements of both modern industrialhydraulics and complex mobile hydraulics, we offer arange of different models:Service Master SCM-250 (3 inputs/channels)Memory capacity = 60,000 MIN and MAX pointsMax. 60 single graphs storable(1-channel operation)Max. 20 different measurements storable(3-channel operation)Service Master SCM-360 (4 inputs/channels)Frequency measurement (I3)Memory capacity = 125,000 MIN and MAX pointsMax. 120 single graphs storable(1-channel operation)Max. 30 different measurements storable(3-channel operation)Service Master SCM-400 (6 inputs/channels)Frequency measurement (I3)Memory capacity = 125,000 MIN and MAX pointsMax. 120 single graphs storable(1-channel operation)Max. 20 different measurements storable(6-channel operation)Service Master SCM-450 (6 inputs/channels)Frequency measurement (I3)Memory capacity = 250,000 MIN and MAX pointsMax. 240 single graphs storable(1-channel operation)Max. 40 different measurements storable(6-channel operation)16Catalogue 4054-1/UK


3.2 Service Master Technical SpecificationsSCM 250 360 400 450Input Sensor inputs 3 4 6 6With sensor recognition (p/T/Q/n)• • • •Adaptor <strong>for</strong> external sensors with SCMA-VADCPlug-in connection: 5-pin, push-pullSample rate: ≥ 1 ms = 1,00 measurement values/sec.Resolution: 12 bit + sign = 4,096 stepsFrequency input via input socket I3• • •<strong>for</strong> flow turbine or tachometerFrequency range: 0.5 Hz … 30 kHzSignal input: depends on frequency 5 V PP(max)DisplayGraphic LC• • • •Resolution: 128 x 64 pixelsVisible area: 72 x 40 mmAutomatic adjustment of digit sizeDigit size: 4.2 mm (<strong>for</strong> 8 line display)Accuracy of display: < 0,25 % of Full Scale RangeGraphic curve representation • • • •OperationVia 11-key membrane keyboard• • • •With mechanical tactile touch and embossed edgesInterfaceRS232C (4-pin, push-pull)• • • •optional with a standard RS232/USB PC adaptorBaud rate: 1,200 … 38,400.8 data bits, 1 stop bitOnline data transmission to the PCTransferring recorded data to PC with SensoWin ®FunctionsI1-I2 indication of differential valuesIndication of MIN/MAX/ACTUAL valuesIndication of TEMP values (SCPT/SCT)Auto power off/battery level controlHydraulic power/outflow volume• • • •Measuredvalue memoryMemory capacity (60,000 MIN and MAX points) •Memory capacity (125,000 MIN and MAX points) • •Memory capacity (250,000 MIN and MAX points)•Variable storage interval (e.g. = 10 ms)Number of points per channel (e. g. 4,000 Min-Max)Variable recording time (2 s … 100 h)Trigger: slope/manual/external/timePre triggerExternal trigger with additional device SCMA-TR• • • •• • • •Ambient conditions Temperature range: 0 … +50 °CStorage temperature: -25 … +60 °CTemperature error: < 0.02 %/ °CRel. humidity: < 80 %Protection according to DIN 40050:IP 54 (water spray/ oil)Power supplyHousingInternal: NiCd-battery 7.2 V/700 mAhBattery charging circuitBattey service capacity: 5 h approx.External: with SCSN-450 (220/100 VDC)Automotive cable adaptor as equipment (12/24 VDC)Material: glass ball-rein<strong>for</strong>ced polyamideDimensions: 235 x 106 x 53 mm (L/W/H)Weight: approx. 530 g• • • •• • • •17 Catalogue 4054-1/UK


3.3 Service Master Function Specifications•I1I2I3I4I5I6P• •-IST-223.6212.577.520042044853.4-MIN-10270•2410300barbarU/minU/minl/minbarkW••I1 – I6 Sensor inputs with automatic sensorrecognition (p/T/Q/n).External sensors with SCMA-VADC-250V/A Measuring voltage/current withSCMA-VADC-400I3/ - п - Frequency inputGraphic LC Display: shows measuredvalues, operation menus and graphsAdditional line:Indication of hydraulic power oroutflow volumeStatus line: shows the actual, min and maxvalues and menu settingsExternal power supply via power unitSCSN-450 or automotive cable adaptorPC interface: RS232External trigger module with SCMA-TR-250ON/OFFDATAOUTPUTSETUPOPTIONRECORDON/OFFSwitches the instrument on and offSTOPESCSTARTENTERSETUPOPTIONSystem settings, date/ time,storage operationI1-I2TEMPMenuMIN/MAXACTUALSTARTENTERSTOPESCI1-I2I1=I2Start measurementsStop measurementsDifferential function I1-I2Zero point equalisation (Tara-Function) I1=I2TEMPDATAOUTPUTRECORDSCPT temperature measuring sensorsData output to PC or graphic displayOn-line test (200 ms)Recording and saving of measurements(program or start/Stop)MIN/MAXACTUALRESETACT-, MIN- und MAX-displayRESET deletes MIN/MAX-valuesOrder codeService Master(Delivery includesSCSN-450 power unit)Number ofmeasuring channelsFrequencymeasuringMIN and MAXvalue memory3 — 60.000 points4 • 125.000 points6 • 125.000 points6 • 250.000 points250360400450SCM-XXX-1-01Automotive cable adaptor 12/24 VDCSensoWin ® PC Software-KitSCK-318-05-21SCSW-KIT-40018Catalogue 4054-1/UK


3.3 Service Master Function SpecificationsThe Service Master can be used as a measuring instrument in three different versions:1. Measuring and readout2. Data logging and recordingThrough automatic sensor recognition all measuredvalues are shown immediately on the display. Eachinput can be used as required. The display switchesautomatically to the appropriate line size.3.Peak pressure measurement (MIN/ MAX display)The scanning rate of 1,000 measurement values/scaptures rapidly occurring pressure peaks withinthe space of a millisecond.Differential pressure measurementExact Δp measurement is achieved by means ofthe Δp adjustment. Under operating pressure thedeviation of the pressure sensors relative to eachother is corrected. For load sensing control theexact Δp setting is a prerequisite <strong>for</strong> trouble-freefunctioning of the hydraulics. A combination ofΔp (bar) and flow Q (I/ min) is displayed ashydraulic power P (kW).External sensorsAnalogue signals such as those from a <strong>for</strong>ce orstroke sensor (external sensor) can also be measuredand evaluated with the Service Master. Themeasurement of electrical currents or voltages(<strong>for</strong> example proportional valves) up to 1.5 ADCor 48 VDC. External modules make the Service-Master a multifunctional measuring instrument.SCMA-VADC-250SCMA-VADC-400SCMA-TR-250Online OperationSignals(0...20 mA or 0...10 VDC)V/A measurement(1,5 ADC or 48 VDC)external trigger signalIn On-line operation all measurement values are transferreddirectly from the Service Master to a PC andsubsequently stored. The current graphic display inSensoWin ® allows the hydraulics to be set (valve positionor pressure load) whilst the test is running.With the SCMA-AO-400 the measurement values aredocumented as analogue signals (0…20 mA) on anexternal device (<strong>for</strong> example, graphic recorder or oscilloscope).The sensor signals can be processed directlyby an external A/D converter or PLC control unit.The recording (storage) of measurements providesdocumentation of settings and the actual condition ofthe hydraulics.Measurements can be printed or further processed on aPC with SensoWin ® software. This is ideal <strong>for</strong> customercare or service since the measurements can be calledup at any time.With the special storage technology of the Service-Master, all pressure peaks in the hydraulic system canbe captured independently of the set measurementtime (storage time). The storage interval (time intervalbetween storage points) is automatically adapted withinthe base setting of the Service Master. Within each storageinterval one min. and one max. value is stored. Theuser has only to pre-select the measuring time (storagetime = 100 h. max.).Individual setting of the storage interval is likewise available(<strong>for</strong> example, 10 ms).Start-stop functionThe start and finish of measurementsare controlled by the start/stop key onlyProgram-controlled recordingFour programs may be selected:■ Flank triggerRecording starts by pressure increase(60 bar, increasing slope)■ ManualStart by pressing enter key■ External triggerStarts recording by external signal(e.g. rely contact)■ Clock timeStart at e.g. 14.25 hIn each programme the recording time (2s…100 h)and the corresponding start function are selected.All the connected channels (sensors) are measuredand stored. Program-controlled storage is particularlyadvantageous during the search <strong>for</strong> faultsin hydraulic machinery. The point when the causeof damage occurs (<strong>for</strong> example, pressure peak orpressure drop) is not as a rule <strong>for</strong>eseeable.With the help of SensoWin ® the recording can besubsequently analysed exactly.19 Catalogue 4054-1/UK


3.3 Service Master Function Specifications250 barMAXMAX120 bar50 barMINMIN1 2[min]With the Service Master up to 6 sensors can bemeasured, displayed and recorded simultaneously. Eachsensor (channel) enables up to 4,000 memory intervalsto be created. Each memory interval will save a pair ofdata points. The pair consists of one MIN and one MAXreading.In a recording session of 10 min and 4,000 intervals,the length of each storage interval is 150 ms.Running a constant scanning rate of 1,000 readings/sthis will correspond to 150 readings (interval).The highest (max) and lowest (min) will be carried to themeasurements memory. The connection of these datapoints creates a measured graph and guarantees thecapture of pressure peaks.250 barMAXMAX120 bar50 barMINMIN1 2[min]20Catalogue 4054-1/UK


START3.4 Service Master Pressure MeasurementSCK-102-03-02In12ON/OFFACT285.9595.7SETUPOPTIONbarbarDATAOUTPUTRECORDSTOPESCENTERI1-I2TEMPSCPT-xxx-02-02MIN/MAXACTUALService MasterSCA-EMA-3/3SMA3-xxxEMA3Pressure/Temperature measurement SCPTThere is a selection of various measuring ranges <strong>for</strong>the measuring of pressures. Sensors can be used <strong>for</strong>pneumatic applications and also <strong>for</strong> measuring pressurepeaks up to 1000 bar. The pressure/temperaturesensors of the SCPT series have a temperature channelwhich is retrieved via the TEMP key.<strong>Diagnostic</strong> adaptorsAll pressure sensors in a measurement case (kit) areprovided with a factory-assembled SCA-1/2-EMA-3diagnostic adaptor. The pressure sensors can beadapted to all standard measuring connections with thehelp of diagnostic couplings supplied.They are perfectly suitable <strong>for</strong> a quick and flexiblediagnoses in hydraulic applications.21 Catalogue 4054-1/UK


3.5 Service Master Flow Volume and RPM MeasurementSCK-102-03-02In12ON/OFFACT85.82250SETUPOPTIONlpmRPMDATAOUTPUTRECORDSTOPESCSTARTENTERI1-I2TEMPMIN/MAXACTUALService MasterSCRPM-220FLOWSCFTSCFT-xxx-02-0222Catalogue 4054-1/UK


3.6 Service Master Electrical Signal MeasurementI118.5 VON/OFFSETUPOPTIONDATAOUTPUTRECORDServiceMasterSTOPESCSTARTENTERSCMA-VADCADC0...1.5Amax.COM0...48Vmax.+VDCSensoControlI1-I2TEMPMIN/MAXACTUALService MasterSCMA-TR-250Measurement of electrical signalswith Service Master SCM-xxx-1-01SCK-313-02-31External triggering ofstorage measurements• Measurement of external signalsSCMA-VADC-250Signals such as 0/4…20 mA or 0…10 V from externalsensors, <strong>for</strong> example, <strong>for</strong> torque, power or stroke, areconnected to the Service Master.Typical applications:• Power/stroke graphs• Torque/flow volume nominal lines• Current/voltage measurementSCMA-VADC-400Electric currents up to 1,5 ADC and voltages up to48 VDC can be measured with this module.Applications:• Current consumption of a proportional valve• Measurement of switch status in motors/pumps• SCMA-TR-250External signals such as relay contacts, <strong>for</strong> example, canbe used as starting signals <strong>for</strong> measurement recording(storage). The measurement recording begins with theopening of a valve or the start-up of a pump. In orderthat during on-line measurement the external relaytriggering is working, the SCMA-TR-250 is connecteddirectly to the PC.• Analogue Output 0...20mAWith the SCMA-AO-400 (not shown) the measurementsignals are emitted as analogue signals to external devices.The measurement value is graphically registered on agraphic recorder. The analogue signal can be processed inthe hydraulic control as an actual value signal.23 Catalogue 4054-1/UK


4.1 Pressure Measurement Pressure Sensors• Robust stainless steel design• Response times of 1 ms• Capturing of pressure peaks• Accuracy ± 0,25 % typ.• Flexible operation• SCPT sensors with 5 pin socket<strong>for</strong> Serviceman/Service MasterFast response times guarantee the safe capture ofpressure peaks in hydraulic systems. The robuststainless steel construction allows a variety ofapplications, <strong>for</strong> example cooling water or pneumatics.All pressure sensors are delivered with a diagnosisadaptor (M16x2) installed. Connection to the hydraulicsystem takes place quickly and safely. Times <strong>for</strong>installation are reduced.Pressure RangeApplications-1...015 bar Pneumatics/ low pressure0...060 bar Medium pressure0...150 bar Medium pressure0...400 bar Operating pressure hydraulics0...600 bar High pressure0 ... 1000 bar High pressure peaksTemperature Range-25...+105°COil temperature25 Catalogue 4054-1/UK


4.2 Pressure Measurement Technical DataServiceman/Service MasterSCPT-xxx-02-02ø27SCPTPressure/TemperatureSensorwith push-pull connector(5 pin)+ SCA-1/2-EMA-3-1...015 bar0...060 bar0...150 bar0...400 bar0...600 bar015060150400600SW27hex.2792+ SCA-1/2-EMA-3-HP0...1000 bar1000SW30hex.30Connection cable #Serviceman (4 pin) 2 mSCK-102-02-08SW22hex.22Serviceman/Service Master (5 pin) 3 mSCK-102-03-02M16x2Extension 5 m SCK-102-05-12 SCPT-xxx-02-02# SCPT-015 SCPT-060 SCPT-150 SCPT-400 SCPT-600 SCPT-1000Pressure Measuring Range (bar) -1…015 0…060 0...150 0...400 0...600 0...1.000Accuracy (± %) FS typ. 0,25 0,25 0,25 0,25 0,25 0,25max. 0,5 0,5 0,5 0,5 0,5 0,5Overload Pressure P max(bar) 30 120 300 800 1.200 1.200Burst Pressure (bar) 150 500 900 1.200 1.800 2.500Temperature Measuring Range (°C)Accuracy (± 1,5 %) FS-25…+105 -25…+105 -25…+105 -25…+105 -25…+105 -25…+105FS = Full Scale RangeResponse Time (ms) 1 Ambient Temperature Range (°C) -25…+80Pressure Port 1/2“ BSPP Storage Temperature Range (°C) -20...+80Housing Stainless Steel 1.4301 T maxFluid (°C) +105Weight (g) 200 Reliability Cycles (10 6 ) 100Seal Viton ® (FKM) Shock Load IEC 68-2-29Parts in Contact with MediaStainless Steel 1.4301Viton ® (FKM)Vibration ResistanceIEC 68-2-610...500 Hz26Catalogue 4054-1/UK


4.3 Pressure Measurement <strong>Diagnostic</strong> AdaptorsT2S2S1T1<strong>Diagnostic</strong> adaptor# PN T1 T2 L1 S1 S2SCA-1/4-EMA-3 1000 bar 1/4 BSPP M16x2 32 27 22SCA-1/2-EMA-3 630 bar 1/2 BSPP M16x2 36 30 22SCA-1/2-EMA-3-HP 1000 bar 1/2 BSPP M16x2 36 32 22L1S1L1T1SCA-EMA-3/1<strong>Diagnostic</strong> couplings# PN T1 T2 L1 S1 S2SCA-EMA-3/1 630 bar M16x2 -- 37 17 --SCA-EMA-3/2 630 bar M16x2 S12x1.65 31 17 17SCA-EMA-3/3 630 bar M16x2 M16x2 43 17 --SCA-EMA-3/4 630 bar M16x2 M16x1.5 31 17 17S2S1S1S2S1T2T1T1T1T2T1L1SCA-EMA-3/2L1SCA-EMA-3/3L1SCA-EMA-3/4T190° <strong>Diagnostic</strong> adaptor with couplingL1S2# PN T1 T2 L1 L2 S1 S2SCA-90-EMA-3 630 bar M16x2 M16x2 49 26 19 22T2S1L2Please pay attention to pressure range27 Catalogue 4054-1/UK


4.3 Pressure Measurement <strong>Diagnostic</strong> AdaptorsT190º Twin connector, ventable SMA3L1S1T2# PN T1 T2 L1 S1 S2SCA-1/4-EMA-3-EL 630 bar 1/4 BSPP M16x2 39 30 22SCA-1/2-EMA-3-EL 630 bar 1/2 BSPP M16x2 42 36 22S2T2• 90° elbow connector with VSTI (see catalogue 4100)• ∆p-adjustment <strong>for</strong> exact differential pressure measurement• Venting of hydraulics with SMA3 (see catalogue 4100)L1Sensor connections <strong>for</strong> hoseT2S1T1# PN T1 T2 L1 S1 S2SCA-1/4-EMA-3-S 630 bar 1/4 BSPP M16x2 54 24 --SCA-1/2-EMA-3-S 630 bar 1/2 BSPP M16x2 60 30 --• SMA-3 diagnostic hose (see catalogue 4100)S1Parker <strong>Diagnostic</strong> quick couplingsL1SCA-1/2-PQCT1# PN T1 T2 L1 S1 S2SCA-1/4-PQC 400 bar 1/4 BSPP -- -- -- --SCA-1/2-PQC 400 bar 1/2 BSPP -- 64 30 --SCA-EMA-3/PD 630 bar M16x2 -- 78 21 17S1S2T1L1SCA-EMA-3/PDPlease pay attention to pressure rangePN (bar) 630 PN (bar) 1.000P max(bar) 800 P max(bar) 1.200Burst pressure (bar) 1.200 Burst pressure (bar) 2.00028Catalogue 4054-1/UK


5 Temperature Measurement• High pressure-prooftemperature sensor• Measurement of oil temperaturesup to 125 °C• Flexible operation• Screw-in or manual sensor• Screw-in sensor with socket<strong>for</strong> Serviceman and Service MasterIn hydraulics, temperature measurements serve to locatefaults and avoid the kind of damage caused by excessiveoil temperatures in critical parts such as pumps andproportional valves.To get the exact temperature, the measurement is donedirectly in the tube or hose line.The screw-in sensors SCT-150 are compatible with flowmeasurement turbines SCFT-xxx-02-02.29 Catalogue 4054-1/UK


5.1 Temperature Measurement ServicemanSCK-102-03-02Serviceman SCM-152-x-02SCK-102-03-02 SCT-150-0-02SCT-150-0-02SCT-150-04-02SCA-GMA3/20S/T30Catalogue 4054-1/UK


5.2 Temperature Measurement Service Master ServiceMasterIn123ACT65.958.7285.7°C°C°CSCK-102-03-02SCK-102-03-02ON/OFFSETUPOPTIONSCTA-400-02DATARECORDOUTPUTSTOPSTARTESCENTERI1-I2TEMPI1=I2MIN/MAXACTUALRESETService MasterSCT-150-04-02 SCT-150-0-02SCT-400-K-01SCT-150-0-02SCT-400-K-01 withsignal converter SCTA-400-02High temperature-proof thermocouple-sensorsare used <strong>for</strong> the measurement of exhaust-gastemperatures up to 1,000 °C in diesel engines.The converter SCTA-400 is compatible with allthermocouple-sensors of the model K.SCT-150 (-25°C...+125°C)Oil temperatures in tanks and containers aremeasured with the help of hand probeSCT-150-0-02The temperature sensor SCT-150-04-02 can beadapted to the hydraulic system up to a systempressure of 630 bar. The male stud is compatiblewith the test points of the GMA3/20 series andwith flow turbine SCFT-xxx.31 Catalogue 4054-1/UK


5.3 Temperature Measurement Technical Data SCT-150-0-02IN-LINE SensorSCT-150-04-02with IN-LINE adaptorSignal converterSCTA-400-02SCT IN-LINE Sensor M10x1 #SCT-150 with female connector (5 pin)IN-LINE adaptor with M10 portSCT-150 IN-LINE Adaptor Tube assembly(5 pin)SCT-150-04-02SCA-GMA3/20S/TSCT-150-0-02Connection cables SCT-150-04-02/SCT-150-0-02 #Serviceman (4 pin) 2 mServiceman/Service Master (5 pin) 3 mExtension 5 mSCK-102-02-08SCK-102-03-02SCK-102-05-12HandprobeSCT-150-0-02SCT-400-K-01SCT-150-04-02 SCT-150-0-02 SCT-400-K-01 SCTA-400-02Measuring Range (°C) -25...+125 -25...+125 0…+1.000 0…+1.000Accuracy ± 1,5°C ± 1,5°C ± 1,5°C ± 1,0%FSResponse Time T 0,9(sec.) 13,5 9,1 ≤ 5 -Ambient Temperature (°C) -25...+70 -25...+70 -20...+150 0...+50Storage Temperature (°C) -25...+80 -25...+80 -20...+80 -25...+60T max(°C) +125 +125 - -Operating Pressure (bar) 630 - - -P max(bar) 630 - - -Burst Pressure (bar) 1.200 - - -HousingSteel C15KgalvanizedProbe: Stainless Steel1.4304Grip: Delrin32Stainless SteelSeal Viton ® (FKM ) - - -Weight (g) 100 120 150 -Parts in Contact with MediaFS = FullScaleSteel C15KgalvanizedViton ® (FKM )Stainless Steel1.4304ABSStainless Steel -Catalogue 4054-1/UK


6 Determination of Flow VolumeDepending on the measurement job to be done,various measuring instruments are availableto the hydraulic technician:1 Flow meter type SCQ• Flow measurement with direction indication• Very fast reaction time < 2 ms• Wide viscosity range• Screw-in cartridge in connector block SCAQ2 Turbine flow meter type SCFT• Very low flow resistance• Built-in measurement points <strong>for</strong> pressureand temperature• Very simple installation into a hydraulic system• 6 different measuring ranges up to 750 l/min.• Recording of a p/Q characteristic curve with a loadvalve to determine hydraulic per<strong>for</strong>mance3 Gear flow meter type SCVF• High precision flow measurement overa wide range of viscosity• 4 measuring ranges up to 300 l/min.• flexible use with various fluidsIn addition to pressure measurement, the precisedetermination of flow volume in hydraulic equipmentgives important evidence of the condition of thehydraulics. The efficiency of hydraulic drives such ashydrostatic units or variable pumps depends on theamount of flow. Hydraulic per<strong>for</strong>mance is determinedby pressure and flow. The degree of wear in a hydraulicdrive can be ascertained by comparing nominal andactual values. The resulting measurements can be used,<strong>for</strong> example, in preventive maintenance <strong>for</strong> systematicservicing and cost reductions. In mobile hydraulics, theefficiency of the machine is continually checked anddocumented. The diagnosis of pressure and flow therebygives a total analysis.33 Catalogue 4054-1/UK


6.1 Determination of Flow Volume Flow Meters• Measurement principle:spring/piston system• Flow measurement withdirection indication• Response time < 2 ms• Compact design• Withstands pressures up to 420 bar• Wide range of viscosity• p/T/Q measurement possiblewith connection blockFlow measurement with direction indication<strong>for</strong> mobile and stationary measurement jobsFunctionWhen there is a flow from A to B or B to A, thepiston (K) is moved. When at rest, the spring (F) andpiston (K) are in equilibrium. The stroke change (S) isproportional to the flow volume and is converted by thebuilt-in electronics to a measured value. By the changein direction of the piston (B to A) flow directions canbe shown (e.g. –45.8 l/min.). The response time of thepiston movement is less than 0.002 s.SCQ measurementprincipleApplicationIn the field of high pressure hydraulics, the rapidcapture of the amount of flow is of great significance.The reaction times of the SCQ’s enable the dynamicbehaviour of hydraulic systems to be measured. Theindication of direction is helpful when searching <strong>for</strong>faults in hydraulic systems. Rapid load changes, whichcan cause damage <strong>for</strong> example in valves and pumps,can be determined. Installation with a connection blockpermits the combined measurement of p, T and Q.Rapid assembly of the SCQ’s is achieved with an in-lineadaptor <strong>for</strong> tube or hose installation.Robust design makes possible extreme conditionapplications, such as, <strong>for</strong> example, high load changesor rates of pressure increase.34Catalogue 4054-1/UK


6.1 Determination of Flow Volume Flow Meters# SCQ-060 SCQ-150Flow Range QN (l/min) -60...+60 -150...+150Accuracy (± %) FS @ 46cSt. 2,0 2,0Operating Pressure PN (bar) 315 315Ports M24 (NG10) M42 (NG16)Pressure Drop P max(bar) @ (FS)GraphsWeight (g) 670 1050FS = FullScaleResponse Time (ms) 2 Ambient Temperature (°C) +10...+60Q max(l/min) QN x 1,1 Storage Temperature (°C) -20...+80Overload Pressure P max(bar) 420HousingSteelT maxFluid (°C) +80Sealing NBR Filtration (µm) 25Parts in Contact with Media Steel, NBR Viscosity Range (cSt.) 15...100# SCAQ-GI-R-1/2 SCAQ-060 SCAQ-150Ports (SCQ) M24 (NG10) M24 (NG10) M42 (NG16)Ports (A - B) 1/2“ BSPP 1/2“ BSPP 3/4“ BSPP8060307558 10301012068 42ø6.58.5AB40604460ABY1980XM6 838 208 tief44M820 tief42.5 5515 102.10.5G1/2ø28.52.11.3SCAQ-060SCAQ-150G3/4ø34G1/4ø1636Catalogue 4054-1/UK


6.1 Determination of Flow Volume Flow Meters50(30 breit)Tightening torque 20 Nm77SW27ca. 68C-RingO-Ring 21.95x1.78O-Ring 20.29x2.62O-Ring 15.54x2.62M24x1.5Port dimensions and pressure drop graph SCQ-060Tightening torque 30 NmwithPort dimensions and pressure drop graph SCQ-15037 Catalogue 4054-1/UK


6.2 Determination of Flow Volume Turbine Flow Meter• Measurement principle:flow turbine• 6 flow ranges up to 750 l/min• Simple installation• Resistant to high pressureup to 480 bar• Low flow resistance• Built-in pressure and temperaturemeasurement points• Suitable <strong>for</strong> reverse operationFlow measurement with low flow resistancecombined p/T/Q measurementFunctionA turbine wheel is driven by the oil flow. The frequenciesthus produced are processed by digital electronics. Theinfluence of turbulent flow effects is compensated <strong>for</strong>.Because of the low flow resistance Q Rthe hydrauliccircuit operates with very low losses. For pressuremeasurement the turbine is equipped with an EMA-3test point.Oil temperatures are measured direct in the oil flow.Consequently all the important measurement parametersare available at one measuring location.Applications• mobile diagnosis (SCFT with SCM)p-Q measurement in construction andagricultural machineshydraulic tests with load valvesautomatic scaling38Catalogue 4054-1/UK


6.2 Determination of Flow Volume Turbine Flow MeterSCK-102-03-02SCK-102-03-02ServicemanSCM-152-x-02Service MasterFLOWSCFTSCFT-xxx-02-02SCFT Serviceman/Service Master #Connection Cables #1 ... 015 l/min4 ... 060 l/min6 ... 150 l/min10 ... 300 l/min20 ... 600 l/min25 ... 750 l/minSCFT-015-02-02SCFT-060-02-02SCFT-150-02-02SCFT-300-02-02SCFT-600-02-02SCFT-750-02-02Serviceman (4 pin) 2 mServiceman/Service Master (5 pin) 3 mExtension 5 mSCK-102-02-08SCK-102-03-02SCK-102-05-1239 Catalogue 4054-1/UK


6.2 Determination of Flow Volume Turbine Flow Meter# SCFT-015 SCFT-060 SCFT-150 SCFT-300 SCFT-600 SCFT-750Flow Range QN (l/min) 1…015 4…060 6...150 10...300 20...600 25...750Accuracy (± %) FS/IR@ 21cSt.Operating PressurePN (bar)1,0 FS 1,0 IR 1,0 IR 1,0 IR 1,0 IR 1,0 IR420 420 420 420 350 480Ports (A - B) 1/2“ BSPP 3/4“ BSPP 3/4“ BSPP 1“ BSPP 1-1/4“ BSPP 1-7/8“ UNFPressure DropΔP max(bar) @ (FS)1,5 1,5 1,5 4 4 5Weight (g) 650 750 750 1200 1800 2100FS = FullScaleIR = Indicated ReadingResponse Time (ms) 50Q max(l/min) QN x 1,1Ambient Temperature (°C) +10...+60Overload Pressure P max(bar) PN x 1,2 Storage Temperature (°C) -20...+80Ports:Temperature Port (SCT-150)Pressure Port (EMA3 Fitting)Pressure Port (VSTI)M10x1 ORM16x21/4“ BSPPT maxFluid (°C) +80Housing Aluminium Filtration (µm) 25SealingParts in Contact with MediaViton ® (FKM)Aluminium, Steel,Viton ® (FKM)Viscosity Range (cSt.) 15...10040Catalogue 4054-1/UK


6.2 Determination of Flow Volume Turbine Flow MeterFLOWECABPQRNMS# SCFT-015 SCFT-060 SCFT-150 SCFT-300 SCFT-600 SCFT-750A 37 62 62 62 62 100B 136 190 190 190 212 212C 37 50 50 50 75 75E 117 130 130 134 150 154M 70 103 103 103 127 126N 0 5 5 7 9 10P 25 50 50 52 62 60Q N/A 92 92 90 106 104R 0 5 5 9 11 10S 115 157 157 150 168 18141 Catalogue 4054-1/UK


6.2 Determination of Flow Volume Hydraulic <strong>Test</strong>erIn123ACT65.9120.859.7barlpm°CON/OFFSETUPOPTIONDATAOUTPUTRECORDSTOPESCSTARTENTERI1-I2TEMPMIN/MAXACTUALMeasurement of pressure, flow andtemperature using Service Master andhydraulic-tester SCLV-PTQFLOWThe p-Q diagram (to the right) shows the powerdetermined. Especially in hydraulic pump (load sensing)systems the speed-dependent load is important toanalyze. The evaluation in SensoWin ® will be donequickly and simply.The hydraulic power of a system can be analyzed by acombined measurement of pressure and flow (to the left).The diagram shows an application with a hydraulic-testerSCLV-PTQ. Pressure in the system is generated by theintegrated loading valve.In the evaluation power will be calculated from the flowvolume and pressure of the pump.42Catalogue 4054-1/UK


6.2 Determination of Flow Volume Hydraulic <strong>Test</strong>er# SCFT-150-DRV SCLV-PTQ-300 SCLV-PTQ-600 SCLV-PTQ-750Flow Range QN (l/min) 6…150 10…300 20…600 25…750Accuracy (± %) IR @ 21cSt. 1,0 1,0 1,0 1,0Operating Pressure PN (bar) 420 420 420 480Ports (A - B) 3/4“ BSPP 1“ BSPP 1-7/8“ UNF 1-7/8“ UNFPressure Drop P max(bar) @ (FS) 15 4 5 5Weight (kg) 4,2 5,5 8,9 8,9FS = FullScaleIR = Indicated ReadingResponse Time (ms) 50Q max(l/min) QN x 1,1Ambient Temperature (°C) +10...+50Overload Pressure P max(bar) PN x 1,2 Storage Temperature (°C) -20...+80Ports:Temperature Port (SCT-150)Pressure Port (EMA3 Fitting)Pressure Port (VSTI)M10x1 ORM16x21/4“ BSPPT maxFluid (°C) +110Housing Aluminium Filtration (µm) 25SealingParts in Contact with MediaViton ® (FKM)Aluminium, Steel,Viton ® (FKM)Viscosity Range (cSt.) 10...90SCLV-PTQ-xxxSCFT-150-DRVEEFLOWFLOWSERIAL No. XXXXXRANGE 10-300 LPM / 3-80 US GPMCCBBA# SCLV-PTQ-300SCLV-PTQ-600SCLV-PTQ-750SCFT-150-DRVA 98 117 62B 222 235 370C 50 75 50E 135 150 13043 Catalogue 4054-1/UK


6.3 Determination of Flow Volume Gear Flow Meter• Measurement principle:volume counter/positive displacement• 4 flow ranges up to 300 l/min• Measurement accuracy ± 0.5% FS• Withstands pressures up to 400 bar• High viscosity range• Low noise emissionGear flow <strong>for</strong> the precision measurement offlow in hydraulic equipmentFunctionThe SCVF gear flow meter operates as a flow volumecounter. A very precisely machined pair of gears is drivenby the fluid flow.The SCVF accommodates a wide range of viscosity.Various seals* permit a large number of applications.ApplicationsBecause of the wide viscosity range, all fluids which canbe pumped and have a certain lubricating capability canbe measured.- brake fluids (EPDM Sealing)- Skydrol- mineral oils- hydraulic oils- fats• mobile diagnosis (SCVF with SCM)exact Q measurement (oil leakage)automatic scaling (sensor recognition)44Catalogue 4054-1/UK


6.3 Determination of Flow Volume Gear Flow MeterSCK-102-03-02SCK-102-03-02ServicemanSCM-152-x-02Service MasterSCVFSCVF Gear Flow Meterwith base plateSCVF Serviceman/Service Master #Connection Cables #0,1 ... 015 l/min0,4 ... 060 l/minSCVF-015-00-02SCVF-060-00-02Serviceman (4 pin) 2 mSCK-102-02-080,4 ... 150 l/minSCVF-150-00-02Serviceman/Service Master (5 pin) 3 mSCK-102-03-021,0 ... 300 l/minSCVF-300-00-02Extension 5 mSCK-102-05-1245 Catalogue 4054-1/UK


6.3 Determination of Flow Volume Gear Flow MeterTyp SCVF-015 SCVF-060 SCVF-150 SCVF-300Flow Range QN (l/min) 1…015 0,4…060 0,6...150 1...300Accuracy (± %) FS @ 21cSt. 0,5 0,5 0,5 0,5Operating Pressure PN (bar) 400 400 315 315Ports (A - B) 3/8“ BSPP 1/2“ BSPP 1“ BSPP 1“ BSPPPressure Drop ΔP max(bar) @ (FS)GraphWeight (kg) 3,8 8,1 23 27FS = FullScale) IR = Indicated ReadingResponse Time (ms) 400 Ambient Temperature (°C) +10...+50Q max(l/min) QN x 1,1 Storage Temperature (°C) -20...+80Overload Pressure P max(bar) PN x 1,2 T maxFluid (°C) +110Housing GGG 40 Filtration (µm) 25SealingParts in contact with mediaViton ® (FKM)Viton ® (FKM), Steel,GGG 40Viscosity Range (cSt.)GraphSCVF-015 Δp − ViscositySCVF-060 Δp − ViscosityQ R[bar]Q R[bar]Q [l/min]SCVF-150 Δp − ViscosityQ [l/min]SCVF-300 Δp − ViscosityQ R[bar]Q R[bar]Q [l/min]Q [l/min]46Catalogue 4054-1/UK


6.3 Determination of Flow Volume Gear Flow Meter41JDGC FM12x1O-RingPøNM58AnzugsdrehmomentRecommended torqueP64LMLKAøNKTypeall measurements in mmWeight (kg)Torque(Nm)A C D F G J K L M ØN PSCVF-015 2 14 85 13 60 57 94 – 70 40 20 9 M6SCVF-060 5,2 35 120 13 95 72 109 10,5 84 72 35 16 M8SCVF-150 9 120 170 18 120 89 140 46,5 46 95 50 25 M12SCVF-300 13 120 170 22 120 105 142 40 46 95 50 25 M1247 Catalogue 4054-1/UK


6.3 Determination of Flow Volume Gear Flow MeterAEKøHPJøNRBFLMCøGfView Ansicht X XøecødXType (kg) A B C E F ØG ØH J K L M ØN P R c ØdØeBSPPSCVF-015 1,8 85 90 35 65 76 7 11 7 70 40 20 6,5 M6/t=14 17 0,7 25 3/8" 13SCVF-060 2,9 100 120 37 80 106 7 11 7 84 72 35 12 M8/t=18 17,5 0,7 29 1/2" 15fSCVF-150SCVF-30014 160 165 80 140 145 9 15 9 46 95 50 25 M12/t=24 28 1 42 1" 19all measurements in mm48Catalogue 4054-1/UK


7 Speed Measurement• Contact less measurement ofrotational speed• Measurement of rotational speedup to 10,000 rpm• Tachometer with fixed cable (2 m)<strong>for</strong> Serviceman or Service MasterRotational speed-depending data, such as delivery froma variable pump, are determined ideally in combinationwith the pressure and flow-test of a hydraulic drive.Contact-less measurement (opto-electronic principal)can be done quickly and easily.Rotational speed is detected, <strong>for</strong> example, at a maindrive shaft (e. g. power take-off shaft of a tractor),and displayed on the hand-held device. Installation oradjustment is not necessary.For accurate acquisition ofthe opto-electronic signal,please use the suppliedreflecting strips.Rotating shaft -non-contact measurementof rotational speed.Cintact measurement ofrotational speed with thecontact adaptorFront face measurementof rotational speed withcontact adaptor.For a shaft or belt,the rotational speed ismeasured directly with thecontact adaptor.49 Catalogue 4054-1/UK


7. 1 Speed Measurement Technical SpecificationsTechnical DataInputMeasuring distance25...500 mmMeasuring angle ± 45°Type of measuringoptical, red LEDOutputMeasuring rangeAccuracyResolution20...10.000 RPM< 0,5% FS± 5 RPMElectrical connectionFixed cable 3 m5-pin push-pull/4-pinAmbient temperature 0...70 °CGeneralMaterialDimensionsWeightFS = Full ScaleABS∅ 34 mm/L = 130 mm230 gTachometer SCPRMContact Adaptor SCRPMA-001Focusing Adaptor SCRPMA-002Order referencesTachometer <strong>for</strong> connection to #Serviceman (4 pin)Connection Cable 3 mServiceman/Service Master (5 pin)Connection Cable 5 mSCRPM-210SCK-108-03-18SCRPM-220SCK-102-05-12SCRPMA-XXXContact AdaptorFocusing AdaptorReflecting strip 0,5 m00100201050Catalogue 4054-1/UK


8 Kits Serviceman/Service Master• Easy operation• Automatic sensor recognition• PC connection• Not dependent on main power supplyService Master-KitServiceman/Service Master-Kits meet therequirements of modern industrial hydraulic systems aswell as those of complex mobile hydraulics.All hydraulic parameters, such as differential pressure,flow and hydraulic power can be measured, displayedand processed.Serviceman-KitsThis allows fitters in mobile hydraulics as well as inconstruction and agricultural machinery to make exactdiagnoses. Furthermore, comparisons between set andactual values can be made and documented.Serviceman/Service Master-Kits are an ideal tool <strong>for</strong>all fitters in maintenance departments who need simplehydraulic test equipment <strong>for</strong> mobile as well as industrialhydraulics. Fast diagnosis in the fields of hydraulicmachinery can be done very easily.With the SensoWin ® software, the data can beprocessed on a PC.The models described on page 52are available ex stock51 Catalogue 4054-1/UK


8 Kits Serviceman/Service MasterServiceman-Kits# SCKIT-152-600 SCKIT-152-1-00 SCKIT-152-2-00SCC SCC-150 SCC-560 SCC-560Serviceman SCM-152-1-02 SCM-152-1-02 SCM-152-2-02SCSW-KIT-152 -- -- 1SCPT-600-02-02 1Please order accessories(SCPT/SCT/SCFT/SCRPM) separate!SCK-102-03-02 1 1 2SCA-EMA-3/3 1 1 2SMA3-1500 1 1 2Service Master-Kits# SCKIT-250-00 SCKIT-360-00 SCKIT-400-00 SCKIT-450-00SCC-750 1 1 1 1Service Master SCM-250-1-01 SCM-360-1-01 SCM-400-1-01 SCM-450-1-01SCSW-KIT-400 1 1 1 1SCK-102-03-02 2 2 2 2SCA-EMA-3/3 2 2 2 2SMA3-1500 2 2 2 2Please order accessories (SCPT/SCT/SCFT/SCRPM) separate!Serviceman/Service Master-p-Q-Kits# SCKIT-152-PQ SCKIT-360-PTQSCC-560 1 1Serviceman SCM-152-2-02 --Service Master -- SCM-360-1-01SCSW-KIT-152 1 --SCSW-KIT-400 -- 1SCPT-600-02-02 1 2SCT-150-04-02 -- 1SCFT-150-DRV 1 1SCK-102-03-02 2 4SCA-EMA-3/3 1 2SMA3-1500 1 252Catalogue 4054-1/UK


9 Calibration Services<strong>Diagnostic</strong> Products with Calibration Certificate acc. to ISO 9001New instruments can be supplied on request with a calibration certificate to ISO 9001.Typ #ServiceJuniorServiceJunior wirelessServicemanService MasterPressure SensorsTemperature SensorFlow SensorsK-SCJN-xxx-01K-SCJNP-xxx-01-RCK-SCM-152-x-02K-SCM-xxx-1-01K-SCPT-xxx-02-02K-SCT-150-04-02K-SCFT-xxx-02-02K-SCQ-xxx-0-02K-SCVF-xxx-00-02Kit #ServiceJuniorServiceJunior wirelessServicemanService MasterK-SCJN-KIT-xxxK-SCJNP-KIT-xxx-RCK-SCKIT-152-x-00K-SCKIT-152-600K-SCKIT-152-PQK-SCKIT-xxx-00K-SCKIT-360-PTQCertificate No. 3143Description: Pressure SensorOperating Range: 0...600 barModel: SCPT-600-02-02 Accuracy: ± 0,5% FSS/N: B1253SReference1: Budenberg S/N 15404 Cal. No. NO94 DKD-KO5801Reference2: HP 3497A Data Logger Cal. No. 8370831402P [bar]2,001,501,000,500,00-0,50 0 10 100 200 300 400 600-1,00-1,50-2,00P [bar]Nominal(bar)Actual(bar)Deviation(bar)0 0 0,0010 9,1 -0,90100 99 -1,00200 199,2 -0,80300 299,5 -0,50400 400 0,00600 600,6 0,600 0,1 0,1053 Catalogue 4054-1/UK


10 IndexSCA-1/2-EMA-3 27/28 SCJN-KIT-xxx 52 SCQ-xxx-0-02 34-37SCA-1/2-EMA-3-EL 27/28 SCJN-xxx-01 6-9SCA-1/2-EMA-3-S 27/28 SCRPM-220 49-50SCA-1/2-PQC 27/28 SCJNP-KIT-xxx-RC 7SCA-1/4-EMA-3 27/28 SCJNP-xxx-01-RC 6-9 SCRPMA-001 49-50SCA-1/4-EMA-3-S 27/28 SCRPMA-002 49-50SCK-102-03-02 13/21/22SCA-EMA-3/1 27/28 SCK-102-05-12 26 SCSN-450 11/18SCA-EMA-3/2 27/28SCA-EMA-3/3 27/28 SCK-318-05-21 11/18 SCSW-KIT-152 11/15SCA-EMA-3/4 27/28 SCSW-KIT-400 24SCA-EMA-3/PD 27/28 SCKIT-152 51-52SCKIT-360-PTQ 51-52 SCT-150-0-02 29-32SCA-GMA3/20S/T 29/32 SCKIT-xxx-00 51-52 SCT-150-04-02 29-32SCAQ-060 35 SCLV-PTQ 42-43 SCT-400-K-01 29-32SCAQ-150 35 SCTA-400-02 29-32SCAQ-GIR1/2A4CX 35 SCM-152-x-02 10-15SCMA 23 SCVF-xxx-00-02 44-48SCFT-150-DRV 43 SCM-xxx-1-01 16-24SCFT-xxx-02-02 38-41SCPT-xxx-02-02 25-2654Catalogue 4054-1/UK


Parker Hannifin CorporationAbout Parker Hannifin CorporationParker Hannifin is a leading global motion-controlcompany dedicated to delivering premier customerservice.A Fortune 500 corporation listed on the New York StockExchange (PH), our components and systems comprise over1,400 product lines that control motion in some 1,000 industrialand aerospace markets.Parker is the only manufacturer to offer its customers a choiceof hydraulic, pneumatic, and electromechanical motion-controlsolutions. Our Company has the largest distribution network inits field, with over 7,500 distributors serving nearly400,000 customers worldwide.Parker’s CharterTo be a leading worldwide manufacturer of components andsystems <strong>for</strong> the builders and users of durable goods.More specifically, we will design, market and manufactureproducts controlling motion, flow and pressure. We will achieveprofitable growth through premier customer service.Product In<strong>for</strong>mationCustomers seeking product in<strong>for</strong>mation, the location of a nearbydistributor, or repair services will receive prompt attentionby calling the Parker Product In<strong>for</strong>mation Centre.The Centre can be called toll free from France, Germany,Austria, Switzerland or the United Kingdom. You will beanswered by a Parker employee in your own language.Call Freephone: 00800-2727-5374 (00800 C PARKER H).The Aerospace Groupis a leader in the development,design, manufacture and servicingof control systems and components<strong>for</strong> aerospace and related hightechnologymarkets, while achievinggrowth through premier customerservice.The Climate & IndustrialControls Group designs,manufactures and markets systemcontroland fluid-handlingcomponents and systems torefrigeration, air-conditioning andindustrial customers worldwide.The FluidConnectorsGroup designs, manufacturesand markets rigid and flexibleconnectors, and associated productsused in pneumatic and fluidsystems.The Seal Group designs,manufactures and distributesindustrial and commercial sealingdevices and related products byproviding superior quality and totalcustomer satisfaction.The <strong>Hydraulics</strong> Groupdesigns, produces and marketsa full spectrum of hydrauliccomponents and systems tobuilders and users of industrial andmobile machinery and equipment.The Filtration Groupdesigns, manufactures and marketsquality filtration and clarificationproducts, providing customers withthe best value, quality, technicalsupport, and global availability.The Automation Groupis a leading supplier of pneumaticand electromechanical componentsand systems to automationcustomers worldwide.The InstrumentationGroup is a global leader in thedesign, manufacture and distributionof high-quality critical flowcomponents <strong>for</strong> worldwide processinstrumentation, ultra-high-purity,medical and analytical applications.


Parker EuropeSales OfficesParker Hannifin Ges.mbHA-2700 Wiener NeustadtTel: +43 2622 23501Fax: +43 2622 66212Parker Hannifin CorporationAE-Abu DhabiTel: +971 2 6788587Fax: +971 2 6793812Parker Hannifin CorporationAZPARAZ-370 000 BakuTel: +994 12983966Fax: +994 12983966Parker Hannifin S.A.-N.V.B-1400 NivellesTel: +32 67280900Fax: +32 67280999Parker Hannifin s.r.o.CZ-184 00 Prague 8Tel: +420 2 83085224Fax: +420 2 83085360Parker Hannifin GmbH & Co. KGD-41564 KaarstTel: +49 2131 513-0Fax: +49 2131 513-230Parker Hannifin Danmark A/SDK-2750 BallerupTel: +45 43560400Fax: +45 43733107Parker Hannifin España S.AE-28850 Torrejón de Ardoz (Madrid)Tel: +34 91 6757300Fax: +34 91 6757711Parker Hannifin CorporationEG-CairoTel: +20 2 5194018Fax: +20 2 5190605Internet: http://www.parker.com/euro_tfdParker Hannifin France SASF-74130 Contamine-sur-ArveTel: +33 450258025Fax: +33 450978660Parker Hannifin OyFIN-01510 VantaaTel: +358 9 476731Fax: +358 9 47673200Parker Hannifin plcGB-Warwick CV34 6TUTel: +44 1926 833700Fax: +44 1926 889172Parker Hannifin CorporationGR-171 21 AthensTel: +30 21 0933-6450Fax: +30 21 0933-6451Parker Hannifin CorporationHU-1149 BudapestTel: +36 1 220-4155Fax: +36 1 422-1525Parker Hannifin S.p.A.I-20094 Corsico (MI)Tel: +39 02 451921Fax: +39 02 4479340Parker Sales Ireland LtdIE-Blackrock, Co. DublinTel: +353 1 293 9999Fax: +353 1 293 9900Parker Hannifin CorporationGateway Ventures Ca Ltd.KZ-480100 AlmatyTel: +7 327 2 543 081Fax: +7 327 2 541 100Parker Hannifin A/SN-1402 SkiTel: +47 64 91 10 00Fax: +47 64 91 10 90Parker Hannifin B.V.NL-7570 AT OldenzaalTel: +31 541 585000Fax: +31 541 585459Parker Hannifin Sp.z.o.o.PL-02-235 WarszawaTel: +48 22 8634942Fax: +48 22 8634944Parker Hannifin Portugal LdaPT-4450-625 Leça da PalmeiraTel: +351 22 9997360Fax: +351 22 9961527Parker Hannifin CorporationHidro Consulting Impex SrlRO-00001 BucharestTel: +40 21 252-1382Fax: +40 21 252-3381Parker Hannifin CorporationRU-123001 MoscowTel: +7 095 2340054Fax: +7 095 2340528Parker Hannifin CorporationRU-693000 Yuzhno-SakhalinskTel: +7 4242 727242Fax: +7 4242 727242Parker Hannifin ABS-16308 SpångaTel: +46 8 59795000Fax: +46 8 59795110Parker Hannifin CorporationSI-8000 Novo MestoTel: +386 7 337-6650Fax: +386 7 337-6651Parker Hannifin CorporationTR-34067 Merter/IstanbulTel: +90 212 48291-06/07Fax: +90 212 48291-10Parker Hannifin CorporationUA-01004 KievTel: +380 44 2207432Fax: +380 44 2206534Parker Hannifin AfricaZA-Kempton ParkTel: +27 11 961-0700Fax: +27 11 392-7213For further in<strong>for</strong>mation on other Parker Products, call the European Product In<strong>for</strong>mation Centrefree of charge on 00800 2727 5374.CAT/4054-1/UK© 2005 Parker Hannifin/1105Bentrup 1105