12.07.2015 Views

HVDC PLUS and SVC PLUS: Reliable and Cost-effective ... - Siemens

HVDC PLUS and SVC PLUS: Reliable and Cost-effective ... - Siemens

HVDC PLUS and SVC PLUS: Reliable and Cost-effective ... - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MMC Power ModulesFull H-Bridgeu acTopology of cascadedH-Bridge converterspatented 1975U dcU dcU acU acU dc0-U dcHalf H-BridgeTopology of cascadedHalf H-Bridge converterspatented 2002u acU dc0"on" "off"© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


MMC for <strong>HVDC</strong> <strong>PLUS</strong>Utilizing Half Bridge Power ModulesConverterReactorPower ModuleConverter Arm© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


<strong>HVDC</strong> <strong>PLUS</strong>Generating Perfect Output Voltages+U dAC <strong>and</strong> DC Voltages controlledby Converter Module Voltages:+U d/2U ACU AC0Phase Unit-U d/2© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


<strong>PLUS</strong> TechnologiesFeatures <strong>and</strong> Benefits of MMC Topology Virtually Harmonic Free Output Voltages• typically no filters• st<strong>and</strong>ard components (e.g. transformers) Low Switching Frequency• low converter losses Compact Station Design• minimum number of primary componentsin the converter station High Modularity in Hardware <strong>and</strong> Software• various topologies possibleHalf-Bridge, Full Bridge,Single Phase, Cyclo-Converter• maintenance friendly• application of "mainstream" module IGBTs Easy to scale to various Output Voltages© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


Trans Bay Cable 2010The First Project© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


<strong>HVDC</strong> <strong>PLUS</strong>Extended Features Transmission Systems Full Active <strong>and</strong> Reactive Power Control Capability System Black Start Operating under unbalanced system conditions AC Fault ride-through No Commutation Failures Compact Design perfectly suited especially for Offshore PlatformsQ capacitive(over excited)PRectifierPInverterQ inductive(under excited)© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


<strong>HVDC</strong> <strong>PLUS</strong>Advantages for <strong>HVDC</strong> TransmissionUnipolar DC VoltagePower reversal by reversing of the DC current fast power reversal possible (not limited by cable dv/dt capability) parallel connection of converters on the DC sideto build Multiterminal Systems <strong>and</strong> DC GridsIncreased Energy StorageDistributed storage capacitance Operation under unbalanced AC system voltages• Voltage balancing• Operating through unbalanced AC system faults Providing fault currents to the AC system© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


<strong>HVDC</strong> <strong>PLUS</strong> - Thoroughly Tested (I)Power Block-Deblock -- Extended Simulator TestTrans Bay Cable150 ms© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


<strong>HVDC</strong> <strong>PLUS</strong> - Thoroughly Tested (II)Commissioning TestsTrans Bay Cable© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


<strong>HVDC</strong> <strong>PLUS</strong>About 5.000 MW under Contract after Trans Bay CableProject MW Location In Service YearTrans Bay Cable 400 USA 2010Borwin2 800 Germany 2013Helwin1 576 Germany 2013INELFE 2*1000 France-Spain 2013Sylwin1 864 Germany 2014Helwin2 690 Germany 2015Page 11Oct-11E T PS EN12© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


Full Bridge Power Modules for <strong>SVC</strong> <strong>PLUS</strong>Page 12Oct-11E T PS EN12© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


<strong>SVC</strong> <strong>PLUS</strong> PortfolioPre-fabricated solutions:<strong>SVC</strong> <strong>PLUS</strong> S: +/- 25 Mvar<strong>SVC</strong> <strong>PLUS</strong> M: +/- 35 Mvar<strong>SVC</strong> <strong>PLUS</strong> L: +/- 50 Mvar8 kV – 15 kVHVLVOpen rack solution (building)<strong>SVC</strong> <strong>PLUS</strong> C: +/-100 Mvar<strong>and</strong> above<strong>SVC</strong> <strong>PLUS</strong> Hybrid with• MSR• MSC<strong>SVC</strong> <strong>PLUS</strong>+/-25 ..+/-50 MvarMSRMSC© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


<strong>SVC</strong> <strong>PLUS</strong>All-in-One ContainerizedCooling System Converter Control&Protection© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


<strong>SVC</strong> <strong>PLUS</strong>Modular Multilevel Converter (MMC)ConverterPower ModuleIGBT Module© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


<strong>SVC</strong> <strong>PLUS</strong> Thanet with MSC <strong>and</strong> MSR, UKMSCMV GISAux.supply<strong>SVC</strong> <strong>PLUS</strong>TransformerMSR132 kV HIS© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


<strong>SVC</strong> <strong>PLUS</strong>Summary Contract awardsProject No of units / Type Customer In Service YearPenrose & Marsden 2x2 <strong>SVC</strong> <strong>PLUS</strong> M Transpower (New Zeal<strong>and</strong>) 2013West of Dusson S<strong>and</strong>s 2x <strong>SVC</strong> <strong>PLUS</strong> L Dong Energy (UK) 2014CMC Seguin 2x <strong>SVC</strong> <strong>PLUS</strong> C CMC Steel (USA) 2013TVSZ / Tikhvinski 1x <strong>SVC</strong> <strong>PLUS</strong> C TVSZ (Russia) 2012Goliat Hyggevatn 2x <strong>SVC</strong> <strong>PLUS</strong> M ENI Norge 2013Qasco 1x <strong>SVC</strong> <strong>PLUS</strong> C Qatar Steel Company (Qatar) 2012Wycarbah, Duringa, Bluff3x <strong>SVC</strong> <strong>PLUS</strong> CPowerlink (Australia)2012Rio Branco1x <strong>SVC</strong> <strong>PLUS</strong> LElectronorte (Brazil)2011Gwynt y Mor2x <strong>SVC</strong> <strong>PLUS</strong> LRWE npower2012Lincs2x <strong>SVC</strong> <strong>PLUS</strong> LLincs Windfarm Ltd. (UK)2011Haywards1x <strong>SVC</strong> <strong>PLUS</strong> CTranspower (New Zeal<strong>and</strong>)2013London Array4x <strong>SVC</strong> <strong>PLUS</strong> LLondon Array (UK)2011Mocuba1x <strong>SVC</strong> <strong>PLUS</strong> MEdM (Mozambique)2011Thyssen Krupp1x <strong>SVC</strong> <strong>PLUS</strong> CThyssen Krupp (USA)2012Greater Gabbard3x <strong>SVC</strong> <strong>PLUS</strong> LGreater Gabbard Offshore Ltd (UK)2010Kikiwa2x<strong>SVC</strong> <strong>PLUS</strong> MTranspower (New Zeal<strong>and</strong>)2010Thanet2x<strong>SVC</strong> <strong>PLUS</strong> MThanet Offshore Ltd. (UK)200934 units under project execution / commercial operation© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions


<strong>HVDC</strong> <strong>PLUS</strong> <strong>and</strong> <strong>SVC</strong> <strong>PLUS</strong>: <strong>Reliable</strong> <strong>and</strong><strong>Cost</strong>-<strong>effective</strong> Power Transmission Solutionswith Modular Multilevel ConvertersC. Bartzsch, Dr. H. Huang, T. Westerweller - <strong>Siemens</strong>, GermanyDr. M. Davies - High Electrical Power, Australia© <strong>Siemens</strong> AG 2011Energy Sector / Power Transmission Solutions

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!