12.07.2015 Views

Centrifugal Power Roof Ventilators - American Coolair

Centrifugal Power Roof Ventilators - American Coolair

Centrifugal Power Roof Ventilators - American Coolair

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CRBCA16 / CRBA16 Performance DataCFM at Static PressureRPM Range0.00 .125 .250 .375 .500 .750 1.00 1.25 1.50 2.00 Motor HPBHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone BHP Sone 1/4 1/3 1/2 3/4 1 1 ½2,170 2,034 1,862 1,683 1,4270.15 7.3 0.17 6.4 0.19 5.9 0.20 5.4 0.20 4.82,279 2,152 1,992 1,823 1,6200.18 7.8 0.20 7.0 0.21 6.6 0.23 6.1 0.23 5.62,385 2,265 2,116 1,954 1,7800.20 8.5 0.22 7.8 0.24 7.3 0.26 6.8 0.27 6.42,495 2,381 2,242 2,086 1,9300.23 9.2 0.26 8.6 0.28 8.1 0.29 7.7 0.30 7.22,604 2,496 2,367 2,217 2,070 1,6340.26 10.0 0.29 9.5 0.31 8.9 0.33 8.5 0.34 8.1 0.33 7.02,713 2,610 2,489 2,347 2,206 1,8530.30 10.8 0.32 10.4 0.35 9.7 0.37 9.5 0.38 8.9 0.39 7.92,820 2,721 2,607 2,473 2,336 2,0290.34 11.8 0.36 11.3 0.39 10.6 0.41 10.4 0.42 9.8 0.44 9.02,929 2,834 2,727 2,601 2,467 2,191 1,6590.38 12.7 0.40 12.3 0.43 11.6 0.45 11.3 0.47 10.9 0.49 10.1 0.45 9.03,039 2,947 2,845 2,727 2,598 2,341 1,9580.42 13.6 0.45 13.4 0.47 12.5 0.50 12.2 0.52 11.9 0.54 11.1 0.54 10.03,145 3,057 2,960 2,848 2,725 2,480 2,1610.47 14.7 0.50 14.5 0.52 13.6 0.55 13.2 0.57 13.0 0.60 12.1 0.61 11.13,254 3,170 3,077 2,972 2,854 2,617 2,3400.52 15.7 0.55 15.6 0.58 14.8 0.60 14.2 0.62 14.1 0.66 13.1 0.68 12.43,364 3,282 3,193 3,093 2,982 2,751 2,503 2,1140.57 16.8 0.60 16.7 0.63 16.0 0.66 15.3 0.68 15.2 0.72 14.2 0.75 13.7 0.72 12.53,470 3,391 3,306 3,211 3,105 2,880 2,651 2,3330.63 17.9 0.66 17.9 0.69 17.2 0.72 16.3 0.74 16.2 0.79 15.3 0.81 14.8 0.81 13.73,579 3,503 3,421 3,331 3,230 3,012 2,796 2,5220.69 18.9 0.72 19.0 0.75 18.3 0.78 17.4 0.81 17.2 0.85 16.4 0.89 15.8 0.90 14.93,689 3,615 3,536 3,449 3,354 3,143 2,936 2,693 2,3250.75 19.7 0.79 19.8 0.82 19.2 0.85 18.3 0.88 17.9 0.93 17.4 0.96 16.5 0.98 16.0 0.95 14.83,798 3,727 3,650 3,567 3,476 3,273 3,072 2,852 2,5500.82 21 0.86 21 0.89 20 0.92 19.2 0.95 18.7 1.01 18.4 1.04 17.3 1.07 17.0 1.06 15.73,905 3,835 3,761 3,681 3,595 3,399 3,202 2,998 2,7360.89 21 0.93 21 0.96 21 1.00 20 1.03 19.5 1.08 19.3 1.13 18.1 1.16 17.8 1.17 16.94,073 4,007 3,936 3,861 3,780 3,597 3,406 3,218 2,9981.01 23 1.05 23 1.09 22 1.12 22 1.16 21 1.22 21 1.26 19.6 1.30 19.0 1.33 18.54,182 4,118 4,050 3,977 3,899 3,725 3,537 3,355 3,154 2,4841.10 23 1.14 24 1.17 23 1.21 23 1.24 22 1.31 21 1.36 21 1.40 19.8 1.43 19.5 1.35 17.74,292 4,229 4,163 4,093 4,018 3,851 3,668 3,490 3,303 2,7571.19 24 1.23 24 1.26 24 1.30 23 1.34 23 1.40 22 1.46 22 1.50 21 1.54 21 1.51 18.64,401 4,340 4,276 4,208 4,136 3,975 3,798 3,623 3,447 2,9731.28 25 1.32 25 1.36 25 1.40 24 1.43 24 1.50 23 1.56 23 1.61 22 1.65 21 1.66 19.6RPM7347718078448819189549911028106411011138117412111248128513211378141514521489Performance shown is for Type A: free inlet, free outlet. Performance ratings do not include the effects of appurtenances (accessories).<strong>Power</strong> rating (BHP) does not include transmission losses. Bearing losses are included.The sound ratings shown are loudness values in hemispherical sones at 1.5 m (5 ft) in a hemispherical free field calculated per AMCA Standard 301.Values shown are for Installation Type A: free inlet hemispherical sone levels.ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!