12.07.2015 Views

Ivium Product Brochure - LabSolutions

Ivium Product Brochure - LabSolutions

Ivium Product Brochure - LabSolutions

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

discover:our complete range of instrumentsinnovative solutions for electrochemical research


Where high power meetshigh performanceFor applications requiring a wide dynamic range.<strong>Ivium</strong>StatmHigh power general purpose potentiostat/galvanostat/ZRAwith integrated impedance analyserThe <strong>Ivium</strong>Stat is a well suited for applications requiring a wide dynamic range.The high current capability combined with its complete range of options enables application in i.e. research,corrosion, battery/fuel cell testing, analysis, bio- and nano-electrochemistry.The <strong>Ivium</strong>Stat is available in 2 power configurations• ±5A / ±10V• ±2A / ±50V• current- and voltage boosters availableExpandability The <strong>Ivium</strong>Stat is fully compatible with all options andmodules, including: integrated Bipotentiostat and True Linear Scan,the MultiWE32, ModuLight, multiplexer, FastScan and all current- andvoltage boosters.Automation Multiple analog and digital input & output ports areavailable that can be used to monitor & control peripheral equipment.The software integrates this functionality.Safety The compliance (maximum current or potential) of theinstrument can be defined by the operator. In this way valuable samplesmay be protected, and unsafe situations prevented.Complete solution The <strong>Ivium</strong>Stat offers a completepackage. The hardware includes a build-in high-performance FrequencyResponse Analyser, and all the standard Electrochemical techniques.Complete measurement and dataprocessing software is includedSystem Performance: <strong>Ivium</strong>Stat <strong>Ivium</strong>Stat.XReCurrent compliance ± 5A ± 2AMaximum output Voltage ± 10V below 1A ± 50V @ ± 2Aand ± 8V up to 5A4 Electrodes WE, CE, RE, SPotentiostat Bandwidth8 MHz for small signals, 300kHz forlarge signalsStability settingsHigh Speed, Standard, and High StabilityProgrammable response filter 1MHz , 100kHz , 10kHz , 1kHz , 10HzSignal acquisitiondual channel 16 bit ADC, 100.000 samples/secPotentiostat:Applied potential range ±10 V, Additional: ±50Vwith 0.33mV resolutionwith 1.65mV res.Applied potential accuracy 0.2%, or 2mVCurrent ranges±10nA to ±10A in 10 stepsHigh sensitivity current ranges ±1pA, ±10pA, ±100pA, ±1nAMeasured current resolution 0.015% of current range, minimum 0.15fAGalvanostat:Applied current resolution 0.033% of applied current rangeApplied current accuracy 0.2%Potential ranges±1mV, ±10mV, ±100mV, ±1V, ±10V, (±50V for XRe)Measured potential resolution 0.003% of potential range, minimum 40nVImpedance Analyser:Frequency rangeAmplitudeDC offsetDynamic range10µHz to 8MHz0.015mV to 1.0V, or 0.03% to 100% of current range16 bit dc offset subtraction, 2 dc-decoupling filters12nV to 10V, and 0.05fA to 5AElectrometer:Input impedanceInput bias currentBandwidthSpecial functions:Ohmic drop compensation>1000 Gohm //1000 Gohm //


Why Electrochemistsprefer <strong>Ivium</strong> instrumentsFree software• <strong>Ivium</strong> instruments come with a complete software package, including all Electrochemical techniques.• <strong>Ivium</strong>Soft can be installed on an unlimited number of PC’s: no dongles, no codes, no hassle.Integrated design is better than modular• In an integrated instrument, shorter and more optimized signal paths can be created, it will therefore perform better.• An integrated design needs less components and uses less space, it therefore provides better value for money.• An integrated instrument is more reliable, because the statistical probability of failure is less due lower component and connector count.• The calibration of an integrated instrument is easier and more stable, therefore data accuracy is better over time.• Due to system integration it is easy to combine various techniques, such as DC and EIS.Versatile hardware and software• All standard techniques are ready to go, also for novice users.• Advanced users can create new techniques within a few minutes, without doing any programming or scripting.• Full integration of peripheral port functions. External equipment can be connected directly to the equipment and controlled from the <strong>Ivium</strong> software.Compliancerange of<strong>Ivium</strong>instrumentsPocketSTAT CompactStat Vertex <strong>Ivium</strong>Stat <strong>Ivium</strong>-n-StatDefault: 10mA/5V 30mA/10V 1A/10V 5A/10V 2.5A/10VOptions:10V/800mA20V/250mA50V/2A*Optional•100V/100mA • • • 5A/10V10A/10V 40A/10V • • •EIS 100kHz 3MHz 1 MHz* 8MHz 250kHz1MHz*THE Netherlands:<strong>Ivium</strong> Technologies B.V.De Zaale 115612 AJ EindhovenThe Netherlandstel. +31 40 2390600fax. +31 40 2390601e-mail info@ivium.euU.S.A. & Canada:<strong>Ivium</strong> Technologies USA961687 Gateway Blvd., Suite 201DFernandina Beach, FL 32034phone: 800-303-3885 (toll free) /904-310-9060 (office)fax: 904-310-9068e-mail pete@ivium.uscontact: Dr. Pete Peterson2012© Specifications subject to changeinnovative solutions for electrochemical research

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!