12.07.2015 Views

testo 350xl - IE Monitoring Instruments Inc

testo 350xl - IE Monitoring Instruments Inc

testo 350xl - IE Monitoring Instruments Inc

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>testo</strong> 350 Technical DataO2 CO COLOW NO NOLOW NO2 SO2 H2S CXHYRange 0 to 25% vol. 0 to 10,000ppm H2 comp.0 to 500 ppmH2 comp.0 to 3,000ppm0 to 300ppm0 to 500ppm0 to 5,000ppm0 to 300ppm0.01 to 4%Accuracy < 0.2% of m.v. < 5 ppm0 to 99 ppm< 5% of m.v.100 to2,000 ppm< 10% of m.v.2,001 to10,000 ppm< 2 ppm0 to 39.9 ppm< 5% of m.v.40 to500 ppm< 5 ppm0 to 99 ppm< 5% of m.v.100 to2,000 ppm< 10% of m.v.2,001 to3,000 ppm< 2 ppm0 to 39.9 ppm< 5% of m.v.300 ppm< 5 ppm0 to 99 ppm< 5% of m.v.500 ppm< 5 ppm0 to 99 ppm< 5% of m.v.100 to2,000 ppm< 10% of m.v.2,001 to5,000 ppm< 2 ppm0 to 39.9 ppm< 5% of m.v.40 to300 ppm< 400 ppm100 to 4,000ppm< 10% of m.v.> 4,000 ppmResolution 0.1 vol. % 1 ppm 0.1 ppm 1 ppm 0.1 ppm 0.1 ppm 1 ppm 0.1 ppm0.001 vol. %=10 ppmResp. Time 20 s (t95) 40 s (t90) 40 s (t90) 30 s (t90) 30 s (t90) 40 s (t90) 30 s (t90) 35 s (t90) 40 s (t90)CO2CO2CalculatedDifferentialPressure 1DifferentialPressure 2EfficiencyFlowVelocityCurrentVoltageRPMTemperatureRange 0 to 50% vol. 0 - CO2 maxvol. %±80” H2O ±16” H2O 0 to 100% 0 to 7900ft/min0 to 20 mA0 to 10 V20 to 20,000rpm-40 to 2192°FAccuracy±0.3% vol.+1% of m.v.(0 to 25% vol.)±0.5% vol.+1.5% of m.v.(> 25 to 50%vol.)Calculatedfrom O2< 1% m.v.-20” to -80”H2O< 1% m.v.+20” to+80” H2O< 0.5%-19” to+19” H2O< 1% m.v.-16” to 1.2”H2O< 1% m.v.+16” to+1.2” H2O< 0.5%-1.2” to+1.2” H2O±0.04 mA±0.01 V< 33°F-40 to +212°F< 0.5% m.v.+212 to+2192°FResolution0.01% vol.(0 to 25% vol.)0.01% vol.(> 25% vol.)0.01 vol. % 0.01” H2O 0.01” H2O 0.1% 10 ft/min ±0.01 mA±0.01 V1 ppmDimensions: 16” x 11” x 4”Weight: 9 lbs.Storage temperature: -40 to +120 °FOperating temperature: 23 to +113 °FHousing material: ABSMemory: 250,000 readingsPower supply: Via built-in power supply(90 V to 260 V, 47 to 63 Hz) or exchangeablerechargeable batteries or external 12 V cablesElectrical power consumption:0.5 A (110 V AC), 0.3 A (230 V AC)Dewpoint calculation: 32 to 210 °F tdMaximum positive pressure/Flue gas:20” H2OMaximum negative pressure:80” H2OPump flow: acceptable range 0.5 - 1.2 l/min(depending upon application)Max. dust load: 20 g/m³ dust in flue gasMax. humidity load:+158 °F Dewpoint temperature at samplegas inlet of analyzer boxTrigger input:Voltage 5 to 12 Volt (rising or falling edge)Pulse width: > 1 sLoad: 5 V/max, 5 mA, 12 V/max. 40 mAWarranty: Analyzers 2 years (excludingworking parts, e.g. measurement cells...);CO/NO/NO2/SO2/H2S/HC 1 year;O2 measurement cell 1 1/2 years;CO2 IR measurement module 2 years10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!