Validation of Cryopreservation Bags - CBMTG

Validation of Cryopreservation Bags - CBMTG

Validation of Cryopreservation Bags - CBMTG

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Origen 500 ml5 participantsMaco 60 - 100ml5 participantsMiltenyi 500 ml5 participants<strong>CBMTG</strong> Laboratory Committee-Laboratory GuidanceSummary <strong>of</strong> <strong>Validation</strong> <strong>of</strong> <strong>Cryopreservation</strong> <strong>Bags</strong>DeviationsThe Mfg instructions require cuttingsealed tubing so that the end <strong>of</strong> thestub is below the spike port tops.This helps prevent damage fromabrasion by the cassettes. Currentfacility procedure requires 2 seals onthe tubing after aliquoting whichresulted in a stub which extendedbeyond the spike ports.Mfg instructions state that labelsshould not be applied directly to thebag. Current facility labelling includesapplying regulated labels to the bagsurface.Mfg instructions require use <strong>of</strong> overwrap bags during freezing andstorage. Current facility proceduresdo not include the use <strong>of</strong> over wrapbags (2).Mfg instructions require transfer toLN2 vapour for at least 4 hours afterstorage in liquid phase LN2. Facilityprocesses do not include this step.CommentsNeedle free injection port.No over wrap provided.Tubing closest to the bag (approx. 15mm) isthicker than the remainder <strong>of</strong> the tubing andcould not be sealed effectively. Sealing afterthis section leaves tails that are snug to thecassette (X2).Spike protectors cause tight fit in cassettes(X2).Difficult to remove all bubbles due to longspiking guards (x2).Full lot number is not imprinted on the bag asit appears on the wrapper.Close proximity <strong>of</strong> infusion ports makesaccessing awkward.Infusion port tabs are difficult to remove.Drained well.Difficult to drain completely due to large spikeprotectors.Incompatible with current sampling sitecouplers used for infusion by syringe.Certificate <strong>of</strong> analysis and instructions for usemust be obtained from mfg.No over wrap provided (x2).Sterile packaging.Label pocket fits labels without folding.Label pocket too large.Label pocket is at the bottom <strong>of</strong> the bagtherefore does not show when product is inmetal presses.Fits current metal presses and cassettes.Tight fit in cassettes.Seams on all sides <strong>of</strong> bag: breakage risk?Injection port is situated perpendicular to thetubing limiting needle access (X2)4 transfer lines all with different connectortypes not be compatible facility processes(X2).Difficult to degas.Tubing by bag takes longer to seal (X3).Bag dimension results in a thicker aliquotwhich was quite noticeable during thawing.Incompatible with current sampling sitecouplers used for infusion by syringe.Easy to spike.Long spike guards with splits to allow cells todrain.Good drainage.Individual packaging.Comes with over wrap.Lot number is imprinted on bag but not expirydate.Packaging difficult to open.Injection/sampling port may be restrictive forsome needle sizes (X2).Mfg requirement to transfer liquids containingDMSO only through the injection port may notbe compatible with some facility processes.Difficult to degas.Spike ports are tight (x2).Good drainage.Incompatible with current sampling sitecouplers used for infusion by syringe.Product was not licensed as a Medical Devicewith Health Canada as <strong>of</strong> 2010-05-05 (x3).May 2010 Page 2 <strong>of</strong> 5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!