09/2006<br />

- 1 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Table Of Content<br />

<strong>Solutions</strong> <strong>for</strong> <strong>UV</strong> <strong>Systems</strong> 2<br />

<strong>Electronic</strong> <strong>Ballasts</strong> <strong>for</strong> <strong>Low</strong> <strong>Pressure</strong> Lamps and Amalgam Lamps 2<br />

Measurement Technique - Monitors and Sensors 4<br />

Digital Operation System - a Bus System <strong>for</strong> <strong>UV</strong> Facilities 5<br />

<strong>Electronic</strong> <strong>Ballasts</strong> 6<br />

Recommended Lamp-Ballast Combinations 6<br />

Special Lamp-Ballast Combinations 8<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (4pin-type) 9<br />

EVG 11W...20W / 230V AC/ 115V AC/ 24V DC 9<br />

EVG 30...90W / 230V AC 10<br />

EVG 100...200W / 230V AC 11<br />

EVG 200...400W / 230V AC 12<br />

<strong>Electronic</strong> <strong>Ballasts</strong> as Plug-In Cards <strong>for</strong> Rack Mounting - R(S)-EVG 200...400W / 230V AC 13<br />

Microprocessor Controlled <strong>Electronic</strong> <strong>Ballasts</strong> - P-EVG 200...900W / 230V AC 15<br />

EVG 30...240W / 115V AC 16<br />

Single / Twin <strong>Electronic</strong> <strong>Ballasts</strong> <strong>for</strong> Amalgam Lamps - Special Design 18<br />

<strong>UV</strong>-Compact MC 30...200W OS - with LCD and Integrated Hour Counter 20<br />

<strong>UV</strong>-Compact MC 30...200W - with LCD, Integrated Hour Counter and <strong>UV</strong>-Monitor 21<br />

<strong>UV</strong>-Compact MCplus 200...350W - with LCD, Integrated Hour Counter and <strong>UV</strong>-Monitor 22<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (2pin-type) 23<br />

EVG 11W...20W / 230V AC/ 115V AC/ 24V DC 23<br />

EVG 20...200W / 230V AC 24<br />

EVG 30...150W / 115V AC 26<br />

Accessories <strong>for</strong> <strong>Electronic</strong> <strong>Ballasts</strong> 28<br />

Starting Component ESBS01-1/ESBS01 28<br />

Measurement Technique - Monitors and Sensors 29<br />

<strong>UV</strong>-Monitors - Overview 29<br />

Recommended Measurement Combinations of Sensors and Monitors 30<br />

<strong>UV</strong>-Monitor PRO 2 with Status Indication by LED 31<br />

<strong>UV</strong>-Monitor PRO 3 with Relay Contacts and Status Indication by LED 31<br />

<strong>UV</strong>-Monitor PRO 5/ PRO 8 with Relay Contacts and Status Indication by LED 32<br />

<strong>UV</strong>-Monitor PRO10.4 with Relay Contacts and Status Indication by LED and LCD 33<br />

Service Device and Service Software <strong>for</strong> <strong>UV</strong>-Monitor PRO10 34<br />

<strong>UV</strong>-Monitor PRO11 with Relay Contacts and Status Indication by backlighted LCD 35<br />

<strong>UV</strong>-Monitor PRO15 with Relay Contacts, Status Indication by LCD, Integrated Hour Counter 36<br />

<strong>UV</strong>-Monitor PRO16 with Relay Contacts, Status Indication by LCD, Integrated Hour Counter 37<br />

<strong>UV</strong>-Monitor PRO20 <strong>for</strong> Analog and Digital Multi-Sensoring 38<br />

<strong>UV</strong>-Sensors - Overview 39<br />

Silicon Carbide <strong>UV</strong>-Diodes 40<br />

<strong>UV</strong>-Sensors <strong>for</strong> Monitoring of Relative <strong>UV</strong>-Intensities 41<br />

<strong>UV</strong>-Sensors with Extended Flare Angle (Side-Looking Sensors) 42<br />

<strong>UV</strong>-Sensor SiC007 with various output signals 43<br />

<strong>UV</strong>-Sensor SiC021 with various output signals 44<br />

<strong>UV</strong>-Sensors adapted to Special Regulations, Calibrated 45<br />

Measurement Window MF001 <strong>for</strong> DVGW-/OENORM/SiC007-Sensors 46<br />

Interfaces IF01, IF02, IF03 <strong>for</strong> the Connection of Sensors and PLC 47<br />

Control Units SW5 and SW10 <strong>for</strong> Lamp Function Control 48<br />

<strong>UV</strong>-Radiation Meter <strong>UV</strong>M-CP 49<br />

<strong>UV</strong>-Lamps and Accessories 50<br />

Quartz Tubes / Immersion Tube Lamps 50<br />

Contacts and Lamp Sockets <strong>for</strong> <strong>Low</strong> <strong>Pressure</strong> Lamps / Amalgam Lamps 51<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


� wide variety of ballasts:<br />

• ballasts <strong>for</strong> one, two or four lamp<br />

operation<br />

• ballasts with integrated hour counter<br />

and uv-monitor<br />

• power range from 10W to 600W<br />

• lamp current from 100mA to 6A<br />

• supply voltage 115V AC, 230V AC,<br />

12V DC and 24V DC<br />

� instantaneous start without flicker <strong>for</strong><br />

long lamp life time<br />

� equipped with power factor correction -<br />

CE-con<strong>for</strong>m<br />

� lamp faults are indicated by a potential<br />

free relay contact (alarm trigger); LED´s<br />

display the current mode of operation<br />

� up to 30% energy saving compared to<br />

conventional ballasts<br />

� preheat on request<br />

� microprocessor controlled ballasts with<br />

RS485 port <strong>for</strong> PLC (Programmable Logic<br />

Controller) connection<br />

� starting component <strong>for</strong> delayed poweron<br />

of 4 (by cascading up to 16) electronic<br />

ballasts<br />

Generals<br />

Why electronic ballasts?<br />

The electronic ballast became the standard in the lighting industry. It<br />

leads to significant energy and money savings in nearly every application.<br />

The lamp operation is flicker free and the ballast produces virtually<br />

no noise or hum.<br />

The incoming 50/60 Hz power (115 or 230 volts) is converted to highfrequency<br />

AC (usually 20 to 40 kHz). This leads to a constant gas<br />

discharge compared to conventional ballasts and prevents cathode<br />

flicker.<br />

<strong>Electronic</strong> ballasts are more efficient than magnetic ballasts in converting<br />

input power to the proper lamp power. The operation of uvlamps<br />

at higher frequencies reduces end losses, resulting in an<br />

overall lamp-ballast system efficacy increase of 15% to 20%.<br />

09/2006<br />

- 2 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Solutions</strong> <strong>for</strong> <strong>UV</strong> <strong>Systems</strong><br />

<strong>Electronic</strong> <strong>Ballasts</strong> <strong>for</strong> <strong>Low</strong> <strong>Pressure</strong> Lamps and Amalgam Lamps<br />

<strong>Electronic</strong> ballasts are directly interchangeable with magnetic ballasts.<br />

They operate with most of available uv-lamps. Long term<br />

usage has demonstrated the reliability of electronic ballasts.<br />

<strong>Electronic</strong> ballasts that operate two or four lamps at once, are allowing<br />

the use of a single ballast in systems with several lamps. This<br />

reduces installation and field wiring costs. Other advantages are<br />

reduced weight, quieter operation and reduced lamp flicker.<br />

<strong>Electronic</strong> ballasts basically consist of the following functional units:<br />

• filter - EMI-filter to attenuate conducted RF noise<br />

• rectifier<br />

• PFC (power factor correction) - provides sinusoidal line<br />

current<br />

• charging capacitor<br />

• frequency controller (<strong>for</strong> high-frequency conversion)<br />

• power stage<br />

• resonant tank<br />

and also<br />

• fault logic (open-circuit / short-circuit protection)<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Instant, rapid or preheat?<br />

There are three modes of operation of the lamps:<br />

09/2006<br />

� rapid start<br />

� preheat start (-PH)<br />

� instant start (-IS)<br />

Rapid start ballasts<br />

These ballasts are used <strong>for</strong> lamps with four-pin connection.<br />

During startup a short high current pulse is sent to the lamp filament.<br />

This reduces unwanted sputtering of emissive material at the<br />

electrodes.<br />

Compared to instant start ballasts, lamps tend to live longer with<br />

rapid start ballasts, in case of many on-off cycles. So rapid start<br />

ballasts are recommended when the switching cycle <strong>for</strong> the lamps<br />

is more than three times per day.<br />

During operation current is flowing through the lamps filament. The<br />

electrodes of the lamps must fit with this ballast type.<br />

Preheat start ballasts (-PH)<br />

These ballasts are also used <strong>for</strong> lamps with four-pin connection.<br />

Preheat ballasts provide a preheat current at the filaments that<br />

allows the electrode to heat up be<strong>for</strong>e ignition. During the preheat<br />

interval, voltage across the lamp drops to a level that reduces the<br />

unwanted glow current. The ballast applies sufficient voltage to the<br />

electrodes, long enough <strong>for</strong> the electrode to reach the emission<br />

temperature to prevent lamp ignition be<strong>for</strong>e the electrodes are<br />

heated up.<br />

After the end of programmed time <strong>for</strong> preheating, the ballast applies<br />

a voltage across the lamp to ignite it with minimal loss of emissive<br />

material. This optimizes the lifetime of the lamp.<br />

These ballasts are intended <strong>for</strong> applications with many switch on<br />

cycles.<br />

We offer preheat start ballasts on request <strong>for</strong> lamps with a<br />

minimum power of 200W (see the “PH“ in the type name).<br />

Instant start ballasts (-IS)<br />

These ballasts are used <strong>for</strong> lamps with two-pin connection (see the<br />

“IS“ in the type name).<br />

Instant start ballasts ignite lamps by applying high voltage across<br />

the lamp during setup. The high voltage typically ignites the lamp<br />

immediatly. These ballasts do not heat the electrodes.<br />

Instant start ballasts should be used <strong>for</strong> continously lamp operation<br />

with less than three switches per day. The advantage is the lower<br />

wiring ef<strong>for</strong>t compared to four-pin connection.<br />

- 3 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Solutions</strong> <strong>for</strong> <strong>UV</strong> <strong>Systems</strong><br />

<strong>Electronic</strong> <strong>Ballasts</strong> <strong>for</strong> <strong>Low</strong> <strong>Pressure</strong> Lamps and Amalgam Lamps<br />

Operation Modes of <strong>Electronic</strong> <strong>Ballasts</strong><br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Monitors<br />

� wide variety of monitoring units/<br />

monitoring features:<br />

• control units <strong>for</strong> lamp current<br />

control<br />

• monitoring of relative<br />

uv-intensity<br />

• monitoring of absolute<br />

uv-intensity<br />

• display of specific irradiation by using<br />

flow rate measurement and reactor<br />

vessel volume <strong>for</strong> calculation<br />

� com<strong>for</strong>table status indication by LCD<br />

� hour counting/lamp lifetime counting<br />

� potential free relay contacts <strong>for</strong> status<br />

indication<br />

� menu-driven handling and programming<br />

by buttons or PC-Software <strong>for</strong> easy<br />

adjustment and configuration<br />

� can be integrated easily into existing uvsystems<br />

� customer specific applications on request<br />

09/2006<br />

- 4 -<br />

Sensors<br />

� wide variety of sensor -(output-) types:<br />

• fotodiode<br />

• current output<br />

• voltage output<br />

• sensors adapted to special regulations<br />

like German or Austrian rule<br />

� all <strong>UV</strong>-Sensors operate with SiC diodes<br />

� daylight blind<br />

� watertight up to 10bar possible<br />

(depending on the type of sensor)<br />

� stainless steel body<br />

(G1/4’’, G 3/4’’ outside thread<br />

or plug-in body <strong>for</strong> measurement<br />

window MF001)<br />

� side-looking sensors with enhanced<br />

angle of incidence <strong>for</strong> indication of uvradiation<br />

from side<br />

� several supply voltages available<br />

� customer specific adjustment on request<br />

� measurement window MF001 available<br />

� interfaces <strong>for</strong> the connection of sensors<br />

and PLC (programmable logic controller)<br />

available<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Solutions</strong> <strong>for</strong> <strong>UV</strong> <strong>Systems</strong><br />

Measurement Technique - Monitors and Sensors<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Functions<br />

• each component identifies itself on the bus<br />

and exchanges in<strong>for</strong>mation about component<br />

parameters<br />

• the system components communicate<br />

directly to each other<br />

• four wire bus cable connects all components<br />

of the system<br />

Digital Sensor Features<br />

• absolute value detection<br />

• sensor includes several measuring ranges,<br />

the measuring range is changed automatically<br />

depending on the current uv-intensity<br />

• no separate sensor adjustment <strong>for</strong> different<br />

uv-lamp/sensor arrangements<br />

<strong>Electronic</strong> Ballast Features<br />

• lamp/ballast control<br />

software aided by PLC or standard PC<br />

• adjustment of several lamp/ballast parameters<br />

• internal hourmeter<br />

Components<br />

09/2006<br />

- 5 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Digital Operation System<br />

Bus System <strong>for</strong> <strong>UV</strong> Facilities<br />

unique digital interface <strong>for</strong> ballasts, sensors, processors and displays<br />

<strong>Electronic</strong> <strong>Ballasts</strong> Digital Sensors Accessories <strong>UV</strong> Monitor<br />

P-EVG2x[200...350]W/2...2,1A D-SiC003(-PG)(-F) Interface IF03<br />

PRO11<br />

P-EVG800...900W/4...11A<br />

RS-EVG220...400W/2...4,8A<br />

D-SLS-SiC003(-PG)(-F)<br />

D-SLS-SiC004(-PG)(-F)<br />

<strong>for</strong> connection<br />

of uv-diode output sensors<br />

PRO16<br />

PRO20<br />

RS-EVG2x[220...320W]/2...2,2A D-SiC007(-PG)(-F)<br />

D-SiC021(-PG)(-F)<br />

D-SiCDVGW<br />

D-SiCONORM<br />

PLC<br />

Advantages<br />

• digital transmission of signals provides<br />

high noise immunity which allows larger<br />

cable length <strong>for</strong> sensors<br />

• lower costs <strong>for</strong> wiring of the system<br />

Technical Specification<br />

• interface units can be used to communicate<br />

with PLC, PC or modem based controllers<br />

and allow remote monitoring<br />

• open interface protocol allows third party’s<br />

adaptions<br />

• measurement values and commands are<br />

transmitted digitally<br />

• digital sensors <strong>for</strong> low pressure lamps: one<br />

sensor <strong>for</strong> the complete output range from<br />

0,1 up to 200W/m²<br />

• digital sensors <strong>for</strong> medium pressure lamps:<br />

one sensor <strong>for</strong> the complete output range<br />

from 1,0 up to 2000W/m²<br />

• lamp control: on/off, dimming, preheating,<br />

status, lamp power/voltage<br />

• ballast control: switch-on current=operating<br />

current, input voltage control, undervoltage<br />

switch-off<br />

• setup and service become more easy<br />

• extension of the system is possible<br />

• very complex systems can be designed<br />

mains voltage: 230V AC ± 10% CE-con<strong>for</strong>m: yes<br />

mains frequency: 45...65Hz<br />

bus system: RS485 two wire + GND + U B max. bus cable length: 500m<br />

• exchange of communication and error<br />

messages<br />

• no additional controller components<br />

needed<br />

• measuring output as plain text with numerical<br />

value and scale unit<br />

• measuring value request by simple standard<br />

terminal program (e.g. WINDOWS<br />

terminal.exe) or by com<strong>for</strong>table customer<br />

• dimming with current compensation in the<br />

lamps filaments<br />

• preheating and cable length compensation<br />

• readout of lamp/ballast status (error<br />

code), correct connection, filament status,<br />

operation hours...<br />

• multi-sensoring (mapping of sensors and<br />

corresponding <strong>UV</strong> lamps) can be<br />

programmed<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


02/2007<br />

- 6 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong><br />

Recommended Lamp-Ballast Combinations<br />

Please note: We offer the adaption of the ballast to your special lamp or we design your own ballast.<br />

G36T5<br />

G64T5<br />

GHO36T5<br />

GHO64T5<br />

GIA120<br />

GIA200<br />

GIA240<br />

GPH212T5L<br />

GPH287T5L<br />

GPH303T5L<br />

GPH356T5L<br />

GPH436T5HO<br />

GPH436T5L<br />

GPH793T5<br />

GPH846T5<br />

GPH846T5HO<br />

GPH893T5HO<br />

NNI120<br />

NNI200<br />

NNI201/107XL<br />

NNI300/147XL<br />

NNI400<br />

NNI60/25U<br />

NNI80/36U<br />

T<strong>UV</strong>11WT5<br />

T<strong>UV</strong>16<br />

T<strong>UV</strong>18PLL<br />

T<strong>UV</strong>25<br />

T<strong>UV</strong>36T5<br />

T<strong>UV</strong>36HO<br />

T<strong>UV</strong>36PLL<br />

T<strong>UV</strong>36SPT5<br />

T<strong>UV</strong>36T5<br />

T<strong>UV</strong>55<br />

T<strong>UV</strong>60PLL<br />

T<strong>UV</strong>64SPT5<br />

T<strong>UV</strong>64T5<br />

T<strong>UV</strong>64T5HO<br />

T<strong>UV</strong>75<br />

T<strong>UV</strong>95WHOPLL<br />

T<strong>UV</strong>130XPT<br />

T<strong>UV</strong>260XPT<br />

T<strong>UV</strong>270XPT<br />

T<strong>UV</strong>325XPT<br />

T<strong>UV</strong>330XPT<br />

T<strong>UV</strong>240WXPT<br />

UNI120<br />

UNI200<br />

UNI201<br />

UNI260<br />

UNI40<br />

UNI60<br />

230V, rapid start, 4-pin<br />

ST-EVG 11/20 xx x<br />

EVG11-20W/425mA x x x<br />

EVG18W/370mA x<br />

S-EVG30-50W/425mA x x x x x<br />

EVG2x[30-50W]/425mA x x x x x<br />

<strong>UV</strong> Compact MC 30-50W/425mA x x x x x<br />

S-EVG50-70W/425mA x x<br />

EVG2x[50-70W]/425mA x x<br />

<strong>UV</strong> Compact MC 50-70W/425mA x x<br />

S-EVG36W/440mA x x<br />

EVG2x[36W]/440mA x x<br />

S-EVG35-45W/610mA x<br />

EVG2x[35-45W]/610mA x<br />

<strong>UV</strong> Compact MC 35-45W/610mA x<br />

S-EVG50-70W/670mA x x<br />

EVG2x[50-70W]/670mA x x<br />

<strong>UV</strong> Compact MC 50-70W/670mA x x<br />

S-EVG50-70W/760mA x x x<br />

EVG2x[50-70W]/760mA xx x<br />

<strong>UV</strong> Compact MC 50-70W/760mA x x x<br />

S-EVG65-80W/880mA x x x<br />

EVG2x[65-80W]/880mA x x x<br />

<strong>UV</strong> Compact MC 65-80W/880mA x x x<br />

S-EVG90W/950mA x<br />

EVG2x[90W]/950mA x<br />

S-EVG40-60W/1,2A x x<br />

EVG2x[40–60W]/1,2A xx<br />

<strong>UV</strong> Compact MC 40-60W/1,2A x x<br />

EVG150-200W/1A x x<br />

EVG2x[150-200W]/1A x x<br />

<strong>UV</strong> Compact MC 150-200W/1A x x<br />

EVG100-150W/1,5A x x x x<br />

EVG2x[100-150W]/1,5A x x x x<br />

<strong>UV</strong> Compact MC 100-150W/1,5A x x x x<br />

EVG130W/2,1A x<br />

EVG2x[130W]/2,1A x<br />

EVG150-200W/1,5A x x<br />

EVG2x[150-200W]/1,5A x x<br />

<strong>UV</strong> Compact MC 150-200W/1,5A x x<br />

EVG160-200W/2A x x x<br />

EVG2x[160-200W]/2A x x<br />

<strong>UV</strong> Compact MC 160-200W/2A x x<br />

EVG2x[220W]/2A x<br />

R(S)-EVG2x[220W]/2A x<br />

<strong>UV</strong> Compact MCplus 220W/2A x<br />

EVG240W/2A x x x<br />

P-EVG240W/2A x x x<br />

R(S)-EVG240W/2A x x x<br />

<strong>UV</strong> Compact MCplus 240W/2A x x x<br />

EVG2x[240W]/2A x x x<br />

P-EVG2x[240W]/2A x x x<br />

R(S)-EVG2x[240W]/2A x x x<br />

EVG270W/3,8A xx<br />

see next page ⇒<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


R(S)-EVG270W/3,8A x x<br />

EVG2x[270W]/3,8A xx<br />

R(S)-EVG2x[270W]/3,8A x x<br />

EVG300W/2,1A x<br />

R(S)-EVG300W/2,1A x<br />

<strong>UV</strong> Compact MCplus 300W/2,1A x<br />

EVG2x[300W]/2,1A x<br />

R(S)-EVG2x[300W]/2,1A x<br />

P-EVG2x[300W]/2,1A x<br />

EVG320W/2,2A x<br />

R(S)-EVG320W/2,2A x<br />

<strong>UV</strong> Compact MCplus 320W/2,2A x<br />

EVG2x[320W]/2,2A x<br />

R(S)-EVG2x[320W]/2,2A x<br />

EVG400W/3,8A x<br />

R(S)-EVG400W/3,8A x<br />

02/2007<br />

- 7 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong><br />

Recommended Lamp-Ballast Combinations<br />

Please note: We offer the adaption of the ballast to your special lamp or we design your own ballast.<br />

G36T5<br />

G64T5<br />

GHO36T5<br />

GHO64T5<br />

GIA120<br />

GIA200<br />

GIA240<br />

GPH212T5L<br />

GPH287T5L<br />

GPH303T5L<br />

GPH356T5L<br />

GPH436T5HO<br />

GPH436T5L<br />

GPH793T5<br />

GPH846T5<br />

GPH846T5HO<br />

GPH893T5HO<br />

NNI120<br />

NNI200<br />

NNI201/107XL<br />

NNI300/147XL<br />

NNI400<br />

NNI60/25U<br />

NNI80/36U<br />

T<strong>UV</strong>11WT5<br />

T<strong>UV</strong>16<br />

T<strong>UV</strong>18PLL<br />

T<strong>UV</strong>25<br />

T<strong>UV</strong>36T5<br />

T<strong>UV</strong>36HO<br />

T<strong>UV</strong>36PLL<br />

T<strong>UV</strong>36SPT5<br />

T<strong>UV</strong>36T5<br />

T<strong>UV</strong>55<br />

T<strong>UV</strong>60PLL<br />

T<strong>UV</strong>64SPT5<br />

T<strong>UV</strong>64T5<br />

T<strong>UV</strong>64T5HO<br />

T<strong>UV</strong>75<br />

T<strong>UV</strong>95WHOPLL<br />

T<strong>UV</strong>130XPT<br />

T<strong>UV</strong>260XPT<br />

T<strong>UV</strong>270XPT<br />

T<strong>UV</strong>325XPT<br />

T<strong>UV</strong>330XPT<br />

T<strong>UV</strong>240WXPT<br />

UNI120<br />

UNI200<br />

UNI201<br />

UNI260<br />

UNI40<br />

UNI60<br />

EVG330W/4,8A x<br />

R-EVG330W/4,8A x<br />

115V, rapid start, 4-pin<br />

EVG11-20W/425mA -1 xx x<br />

S-EVG30–50W/425mA -1 x x x<br />

EVG2x[30-50W]/425mA -1 x x x<br />

EVG50–70W/425mA -1 x x<br />

EVG2x[50-70W]/425mA -1 x x<br />

EVG35–45W/610mA -1 x<br />

EVG2x[35-45W]/610mA -1 x<br />

EVG50–70W/670mA -1 x<br />

EVG2x[50-70W]/670mA -1 x<br />

EVG50–70W/760mA -1 x x<br />

EVG2x[50-70W]/760mA -1 xx<br />

EVG65–80W/880mA -1 x x x<br />

EVG2x[65-80W]/880mA -1 x x x<br />

EVG150-200W/1A -1 x<br />

EVG100-150W/1,5A -1 x x x x<br />

EVG150-200W/1,5A -1 x x<br />

EVG160-200W/2A -1 x x<br />

EVG240W/2A -1 x x x<br />

EVG300W/2,1A -1<br />

24V DC, rapid start, 4-pin<br />

x<br />

EVG11-20W/425mA -4 xx x<br />

EVG36W/425mA -4<br />

230V, instant start, 2-pin<br />

x x<br />

ST-EVG 11/20 IS x x x<br />

EVG11-20W/425mA IS xx x<br />

S-EVG30-50W/425mA IS x x x<br />

EVG2x[30-50W]/425mA IS x x x<br />

S-EVG50-70W/425mA IS x x<br />

EVG2x[50-70W]/425mA IS x x<br />

S-EVG35-45W/610mA IS x<br />

EVG2x[35-45W]/610mA IS x<br />

EVG4x[20W]/425mA IS x<br />

EVG4x[40W]/425mA IS x x x<br />

S-EVG50-70W/760mA IS x x<br />

EVG2x[50-70W]/760mA IS xx<br />

see next page ⇒<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


S-EVG65-80W/880mA IS x<br />

EVG2x[65-80W]/880mA IS x<br />

EVG4x[150W]/1A IS x x<br />

EVG150-200W/1A IS x<br />

EVG2x[150-200W]/1A IS x<br />

115V, instant start, 2-pin<br />

EVG11-20W/425mA IS x x x<br />

S-EVG30-50W/425mA IS-1 x x x<br />

EVG2x[30–50W]/425mA IS-1 x x x<br />

EVG50-70W/425mA IS-1 x x<br />

EVG2x[50–70W]/425mA IS-1 x x<br />

EVG35-45W/610mA IS-1 x<br />

EVG2x[35–45W]/610mA IS-1 x<br />

EVG50-70W/760mA IS-1 xx<br />

EVG2x[50–70W]/760mA IS-1 x x<br />

EVG65-80W/880mA IS-1 x x<br />

EVG2x[65–80W]/880mA IS-1 x x<br />

EVG150–200W/1A IS-1 x<br />

24V DC, rapid start, 4-pin<br />

EVG11-20W/425mA IS -4 xx x<br />

Special Design <strong>for</strong> LightSources Inc. / LightTech Lamp Technology Ltd.<br />

02/2007<br />

GPHA1000T5L<br />

GPHA1000T6L<br />

- 8 -<br />

GPHA1554T5L<br />

E230.101 x x x<br />

R(S)-E230.101 x<br />

E230.102 x<br />

R(S)-E230.102 x<br />

<strong>UV</strong> Compact MCplus E230.102 x<br />

E230.103 x<br />

R(S)-E230.103 x<br />

<strong>UV</strong> Compact MCplus E230.103 x<br />

S-E230.104 x<br />

S-E230.107 x<br />

E230.108 x x<br />

E230.110 x x x<br />

R(S)-E230.110 x<br />

<strong>UV</strong> Compact MCplus E230.111 x<br />

E230.201 x<br />

R(S)-E230.201 x<br />

E230.202 x<br />

R(S)-E230.202 x<br />

E230.203 x<br />

R(S)-E230.203 x<br />

E230.204 x<br />

E230.205 x x<br />

E230.207 x<br />

E230.208 x x<br />

E230.210 x x<br />

E230.211 x<br />

R(S)-E230.211 x<br />

GPHA1554T6L<br />

GPHA357T5L<br />

GPHA357T6L<br />

GPHA842T5L<br />

GPHA842T6L<br />

GPHHA1000T6L<br />

GPHHA1554T6L<br />

GPHHA357T6L<br />

GPHHA842T6L<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong><br />

Special Lamp-Ballast Combinations<br />

G36T5<br />

G64T5<br />

GHO36T5<br />

GHO64T5<br />

GIA120<br />

GIA200<br />

GIA240<br />

GPH212T5L<br />

GPH287T5L<br />

GPH303T5L<br />

GPH356T5L<br />

GPH436T5HO<br />

GPH436T5L<br />

GPH793T5<br />

GPH846T5<br />

GPH846T5HO<br />

GPH893T5HO<br />

NNI120<br />

NNI200<br />

NNI201/107XL<br />

NNI300/147XL<br />

NNI400<br />

NNI60/25U<br />

NNI80/36U<br />

T<strong>UV</strong>11WT5<br />

T<strong>UV</strong>16<br />

T<strong>UV</strong>18PLL<br />

T<strong>UV</strong>25<br />

T<strong>UV</strong>36T5<br />

T<strong>UV</strong>36HO<br />

T<strong>UV</strong>36PLL<br />

T<strong>UV</strong>36SPT5<br />

T<strong>UV</strong>36T5<br />

T<strong>UV</strong>55<br />

T<strong>UV</strong>60PLL<br />

T<strong>UV</strong>64SPT5<br />

T<strong>UV</strong>64T5<br />

T<strong>UV</strong>64T5HO<br />

T<strong>UV</strong>75<br />

T<strong>UV</strong>95WHOPLL<br />

T<strong>UV</strong>130XPT<br />

T<strong>UV</strong>260XPT<br />

T<strong>UV</strong>270XPT<br />

T<strong>UV</strong>325XPT<br />

T<strong>UV</strong>330XPT<br />

T<strong>UV</strong>240WXPT<br />

UNI120<br />

UNI200<br />

UNI201<br />

UNI260<br />

UNI40<br />

UNI60<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


allast type C<br />

Available <strong>Ballasts</strong><br />

09/2006<br />

ballast type A<br />

ballast type B<br />

ballast type O<br />

ballast name input voltage<br />

[V]<br />

*power supply requirements <strong>for</strong> 24V DC ballast: stabilised, short-circuit proof, inrush current 2A min.<br />

Technical Specification<br />

- 9 -<br />

input input power per<br />

power [W] current [A] lamp [W]<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (4pin-type)<br />

EVG 11W...36W<br />

230V AC / 115V AC / 24V DC<br />

lamp<br />

current [A]<br />

ballast<br />

type<br />

suitable lamp types<br />

(manufacturer model)<br />

ST-EVG 11/20 230V AC ± 10% up to 24 0,05 - 0,11 11-20 0,425 ± 10% C<br />

EVG11-20W/425mA<br />

EVG11-20W/425mA -1<br />

230V AC ± 10% up to 24<br />

115V AC ± 10% up to 24<br />

0,05 - 0,11<br />

0,11 - 0,23<br />

11-20<br />

11-20<br />

0,425 ± 10% A<br />

0,425 ± 10% A<br />

T<strong>UV</strong>16,<br />

GPH287T5L,<br />

GPH303T5L<br />

EVG11-20W/425mA -4 24V* DC ± 10% up to 24 0,47 - 1,1 11-20 0,425 ± 10% B<br />

EVG18W/370mA 230V AC ± 10% 20 0,08 - 0,1 17 0,370 ± 10% A T<strong>UV</strong>18PLL<br />

EVG36W/425mA -4 24V* DC ± 10% up to 24 1,7 - 1,8 36 0,425 ± 10% O G36T5, T<strong>UV</strong>36T5<br />

mains frequency: 45...65Hz tc-temperature: max. 50°C CE-con<strong>for</strong>m: yes<br />

operating frequency: 30...50kHz ambient temperature: 0...40°C efficiency: ca. 85%<br />

max. off-load voltage<br />

on terminals 1...4:<br />

type A: 1.5kVpp , type B: 600Vrms status indication: green and red LED indicate operating status,<br />

type C: buzzer sounds up if the lamp is not working<br />

photocoupler, max. current on OG: 5mA (open collector VOG1/0


Available <strong>Ballasts</strong><br />

ballast name input power<br />

[W]<br />

<strong>Ballasts</strong> <strong>for</strong> two lamps are also working if only one lamp is connected.<br />

09/2006<br />

ballast type D<br />

ballast type F<br />

- 10 -<br />

input<br />

current [A]<br />

lamps per<br />

ballast<br />

power per<br />

lamp [W]<br />

lamp<br />

current [A]<br />

ballast<br />

type<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (4pin-type)<br />

EVG 30...90W / 230V AC<br />

ballasts <strong>for</strong> one and <strong>for</strong> two lamp operation available<br />

suitable lamp types<br />

(manufacturer model)<br />

S-EVG30-50W/425mA 32 - 55 0,13 - 0,26 1 30 - 50 0,39 - 0,42 D G36T5, GPH793T5, T<strong>UV</strong>25,<br />

T<strong>UV</strong>36T5, GPH846T5<br />

EVG2x[30-50W]/425mA up to 110 0,25 - 0,53 2 30 - 50 0,39 - 0,42 F G36T5, GPH793T5, T<strong>UV</strong>25,<br />

T<strong>UV</strong>36T5, GPH846T5<br />

S-EVG50-70W/425mA 55 – 75 0,26 - 0,36 1 50 - 70 0,39 - 0,42 D G64T5, T<strong>UV</strong>64T5<br />

EVG2x[50-70W]/425mA up to 150 0,43 - 0,72 2 50 - 70 0,39 - 0,42 F G64T5, T<strong>UV</strong>64T5<br />

S-EVG36W/440mA 40 0,16 - 0,19 1 36 0,44 D T<strong>UV</strong>36, T<strong>UV</strong>36PLL<br />

EVG2x[36W]/440mA up to 80 0,32 - 0,38 2 36 0,44 F T<strong>UV</strong>36, T<strong>UV</strong>36PLL<br />

S-EVG35-45W/610mA 38 – 50 0,15 - 0,24 1 35 - 45 0,6 - 0,62 D GPH436T5HO<br />

EVG2x[35-45W]/610mA up to 100 0,3 - 0,48 2 35 - 45 0,6 - 0,62 F GPH436T5HO<br />

S-EVG50-70W/670mA 55 – 75 0,26 - 0,36 1 50 - 70 0,65 - 0,7 D NNI60/25U, T<strong>UV</strong>60PLL<br />

EVG2x[50-70W]/670mA up to 150 0,43 - 0,72 2 50 - 70 0,65 - 0,7 F NNI60/25U, T<strong>UV</strong>60PLL<br />

S-EVG50-70W/760mA 55 – 75 0,26 - 0,36 1 50 - 70 0,75 - 0,77 D GPH846T5HO,<br />

GPH893T5HO, T<strong>UV</strong>55<br />

EVG2x[50-70W]/760mA up to 150 0,43 - 0,72 2 50 - 70 0,75 - 0,77 F GPH846T5HO,<br />

GPH893T5HO, T<strong>UV</strong>55<br />

S-EVG65-80W/880mA 70 – 85 0,28 - 0,4 1 65 - 80 0,85 - 0,9 D T<strong>UV</strong>75, GHO36T5,<br />

T<strong>UV</strong>36HO<br />

EVG2x[65-80W]/880mA up to 170 0,55 - 0,8 2 65 - 80 0,85 - 0,9 F T<strong>UV</strong>75, GHO36T5,<br />

T<strong>UV</strong>36HO<br />

S-EVG90W/950mA 100 0,4 - 0,48 1 90 0,95 D T<strong>UV</strong>95WHOPLL<br />

EVG2x[90W]/950mA up to 200 0,8 - 0,97 2 90 0,95 F T<strong>UV</strong>95WHOPLL<br />

S-EVG40-60W/1,2A 44 – 65 0,17 - 0,31 1 40 - 60 1 - 1,2 D UNI40, UNI60<br />

EVG2x[40–60W]/1,2A up to 130 0,34 - 0,62 2 40 - 60 1 - 1,2 F UNI40, UNI60<br />

Technical Specification<br />

mains voltage: 230V AC ± 10% CE-con<strong>for</strong>m: yes efficiency: > 90%<br />

mains frequency: 45...65Hz tc-temperature: max. 50°C<br />

operating frequency: 30...50kHz ambient temperature: 0...40°C<br />

status indication: green and red LED indicate operating status<br />

potential free relay contact,<br />

type D load: 50...200mA at 24...230V AC; 50...500mA at 5V...60V DC<br />

type F load: 50...200mA at 24...120V AC; 50...500mA at 5V...60V DC<br />

wire gauge: type D: 0,5...1mm², type F: 0,75...1,5mm² (type F: max. 0,75mm² <strong>for</strong> potential free relay contacts)<br />

mounting restrictions: upright, mains connector at bottom side, see manual <strong>for</strong> details<br />

Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Available <strong>Ballasts</strong><br />

ballast name input power<br />

[W]<br />

<strong>Ballasts</strong> <strong>for</strong> two lamps are also working if only one lamp is connected.<br />

09/2006<br />

ballast type E<br />

ballast type G<br />

- 11 -<br />

input<br />

current [A]<br />

lamps per<br />

ballast<br />

power per<br />

lamp [W]<br />

lamp<br />

current [A]<br />

ballast<br />

type<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (4pin-type)<br />

EVG 100...200W / 230V AC<br />

ballasts <strong>for</strong> one and <strong>for</strong> two lamp operation available<br />

suitable lamp types<br />

(manufacturer model)<br />

EVG130W/2,1A 140 - 150 0,56 - 0,75 1 130 - 140 2 - 2,1 E T<strong>UV</strong>130XPT<br />

EVG2x[130W]/2,1A up to 300 1,12 - 1,5 2 130 - 140 2 - 2,1 G T<strong>UV</strong>130XPT<br />

EVG150-200W/1A 160 – 220 0,65 - 1,0 1 150 - 200 0,8 – 1 E GHO64T5, T<strong>UV</strong>64T5HO<br />

EVG2x[150-200W]/1A up to 440 1,7 - 2,1 2 150 - 200 0,8 - 1 G GHO64T5, T<strong>UV</strong>64T5HO<br />

EVG100-150W/1,5A 110 - 160 0,43 - 0,77 1 100 -150 1,4 - 1,5 E NNI80/36U, NNI120, UNI120,<br />

GIA120, T<strong>UV</strong>115<br />

EVG2x[100-150W]/1,5A up to 300 0,87 - 1,3 2 100 -150 1,4 - 1,5 G NNI80/36U, NNI120, UNI120,<br />

GIA120, T<strong>UV</strong>115<br />

EVG150-200W/1,5A 160 – 220 0,65 - 1,0 1 150 - 200 1,4 - 1,5 E GIA200, UNI201<br />

EVG2x[150-200W]/1,5A up to 440 1,7 - 2,1 2 150 - 200 1,4 - 1,5 G GIA200, UNI201<br />

EVG160-200W/2A 175 – 220 0,7 - 1,1 1 160 - 200 1,85 – 2 E NNI200, UNI200, NNI201/107XL<br />

EVG2x[160-200W]/2A up to 440 1,7 - 2,1 2 160 - 200 1,85 - 2 G NNI200, UNI200<br />

Technical Specification<br />

mains voltage: 230V AC ± 10% CE-con<strong>for</strong>m: yes<br />

mains frequency: 45...65Hz tc-temperature: max. 50°C<br />

operating frequency: 30...50kHz ambient temperature: 0...40°C<br />

efficiency: > 90%<br />

status indication: green and red LED indicate operating status<br />

potential free relay contact,<br />

load: 50...200mA at 24...120V AC; 50...500mA at 5...60V DC<br />

wire gauge: 0,75...1,5mm²<br />

mounting restrictions: upright, mains connector at bottom side, see manual <strong>for</strong> details<br />

Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Available <strong>Ballasts</strong><br />

ballast name input power<br />

[W]<br />

ballast type H: also available as PREHEAT START version on request<br />

(add -PH to ballast name),<br />

2-STEP DIMMING on request (add -SD to ballast name)<br />

ballast type I: 4-STEP DIMMING is not standard<br />

⇒ implementation on request (add -SD to ballast name)<br />

ballasts <strong>for</strong> two lamps are also working if only one lamp is connected<br />

09/2006<br />

ballast type H<br />

ballast type I<br />

- 12 -<br />

input<br />

current [A]<br />

lamps per<br />

ballast<br />

power per<br />

lamp [W]<br />

lamp<br />

current [A]<br />

ballast<br />

type<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (4pin-type)<br />

EVG 200...400W / 230V AC<br />

ballasts <strong>for</strong> one and <strong>for</strong> two lamp operation available,<br />

PREHEAT START versions available on request (only <strong>for</strong> one lamp ballast type H)<br />

suitable lamp types<br />

(manufacturer model)<br />

EVG2x[220W]/2A 440 - 480 1,74 - 2,31 2 200 - 220 1,9 - 2,2 I NNI201/107XL<br />

EVG240W/2A 250 - 280 0,99 - 1,35 1 220 - 250 1,9 - 2,2 H UNI260, GIA240, T<strong>UV</strong>240WXPT<br />

EVG2x[240W]/2A 500 - 560 1,98 - 2,7 2 220 - 250 1,9 - 2,2 I UNI260, GIA240, T<strong>UV</strong>240WXPT<br />

EVG270W/3,8A 280 - 310 1,1 – 1,5 1 250 -280 3,6 - 4,0 H T<strong>UV</strong>260XPT, T<strong>UV</strong>270XPT<br />

EVG2x[270W]/3,8A 560 - 620 2,21 - 3 2 250 -280 3,6 - 4,0 I T<strong>UV</strong>260XPT, T<strong>UV</strong>270XPT<br />

EVG300W/2,1A 350 1,38 - 1,7 1 320 2,1 - 2,4 H NNI300/147XL<br />

EVG2x[300W]/2,1A 700 2,76 - 3,38 2 320 2,1 - 2,4 I NNI300/147XL<br />

EVG320W/2,2A 350 1,38 - 1,7 1 320 2,1 - 2,4 H T<strong>UV</strong>325XPT<br />

EVG2x[320W]/2,2A 700 2,76 - 3,38 2 320 2,1 - 2,4 I T<strong>UV</strong>325XPT<br />

EVG400W/3,8A 425 1,7 - 2,1 1 400 3,8 H NNI400<br />

EVG330W/4,8A 370 1,46 - 1,79 1 330 4,8 H T<strong>UV</strong>330XPT<br />

Technical Specification<br />

mains voltage: 230V AC ± 10% CE-con<strong>for</strong>m: yes<br />

mains frequency: 45...65Hz tc-temperature: max. 50°C<br />

operating frequency: 30...50kHz ambient temperature: 0...40°C<br />

efficiency: > 90%<br />

status indication: green and red LED indicate operating status<br />

potential free relay contact,<br />

load: 50...200mA at 24...230V AC; 50...500mA at 5...60V DC<br />

mounting restrictions: upright, mains connector at bottom side, see manual <strong>for</strong> details<br />

wire gauge: 0,75...1,5mm²<br />

4-STEP DIMMING scheme<br />

lamp A/B current 100% 90% 80% 70%<br />

DM 1 A/B 0 0 12V DC 12V DC<br />

DM 0 A/B 0 12 V DC 0 12V DC<br />

current approx. 1mA @ 12V DC (voltage range: 9-25V DC)<br />

Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


allast type R<br />

ballast type S<br />

ballast type T<br />

ballast type U<br />

Features<br />

• electronic ballasts as plug-in cards <strong>for</strong> rack<br />

mounting<br />

• preheat start implemented<br />

• all connections (mains, lamp and control<br />

voltage, error control) routed through a<br />

MOLEX JUNIOR FIT connector<br />

• microprocessor controlled<br />

09/2006<br />

- 13 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (4pin-type)<br />

as plug-in cards <strong>for</strong> rack mounting, microprocessor controlled<br />

R-EVG 200...400W (with RS485: RS-EVG 200...400W) / 230V AC<br />

• type R, S (without RS485):<br />

• to be switched on and off externally by<br />

12V...24 DC control voltage<br />

• potential free relay contact <strong>for</strong> fault<br />

indication<br />

ballasts <strong>for</strong> one and two lamp operation available,<br />

PREHEAT START implemented<br />

• type T, U (with RS485):<br />

• switch-on/-off, dimming and status<br />

indication via RS485<br />

• addressable with DIP-switch<br />

up to 1023<br />

• preheat parameters programmable<br />

• dimmable on request<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Available <strong>Ballasts</strong><br />

ballast name input power<br />

[W]<br />

Technical Specification<br />

09/2006<br />

- 14 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (4pin-type)<br />

as plug-in cards <strong>for</strong> rack mounting, microprocessor controlled<br />

R-EVG 200...400W (with RS485: RS-EVG 200...400W) / 230V AC<br />

input<br />

current [A]<br />

Available <strong>Ballasts</strong> <strong>for</strong> Lightsources Inc. / LightTech Lamp Technology Ltd.<br />

ballasts <strong>for</strong> two lamps are also working if only one lamp is connected<br />

mains voltage: 230V AC ± 10% mains frequency: 45...65Hz<br />

ambient temperature: 0...40°C tc-temperature: max. 50°C<br />

operating frequency: 25...70kHz efficiency: > 90%<br />

control voltage: 12...24V DC (contacts optically isolated)<br />

ballasts <strong>for</strong> one and two lamp operation available,<br />

PREHEAT START implemented<br />

status indication: green and red LED indicate operating status<br />

type R, S: potential free relay contact, load: 50...200mA at 24...230V AC; 50...500mA at 5...60V DC<br />

type T, U: RS485 <strong>for</strong> status indication and controlling<br />

mounting restrictions: rack mounting with <strong>for</strong>ced cooling, see manual <strong>for</strong> details<br />

connections: to be used with MOLEX JUNIOR<br />

FIT connector 15-06-0241<br />

lamps per<br />

ballast<br />

power per<br />

lamp [W]<br />

lamp<br />

current [A]<br />

wire gauge: 0,75...1,5mm²<br />

ballast<br />

type<br />

suitable lamp types<br />

(manufacturer model)<br />

R-EVG2x[220W]/2A 440 - 480 1,74 - 2,31 2 200 - 220 1,9 - 2,2 S NNI201/107XL<br />

RS-EVG2x[220W]/2A 440 - 480 1,74 - 2,31 2 200 - 220 1,9 - 2,2 U NNI201/107XL<br />

R-EVG240W/2A 250 - 280 0,99 - 1,35 1 220 - 250 1,9 - 2,2 R UNI260, GIA240, T<strong>UV</strong>240WXPT<br />

RS-EVG240W/2A 250 - 280 0,99 - 1,35 1 220 - 250 1,9 - 2,2 T UNI260, GIA240, T<strong>UV</strong>240WXPT<br />

R-EVG2x[240W]/2A 500 - 560 1,98 - 2,7 2 220 - 250 1,9 - 2,2 S UNI260, GIA240, T<strong>UV</strong>240WXPT<br />

RS-EVG2x[240W]/2A 500 - 560 1,98 - 2,7 2 220 - 250 1,9 - 2,2 U UNI260, GIA240, T<strong>UV</strong>240WXPT<br />

R-EVG270W/3,8A 280 - 310 1,1 – 1,5 1 250 -280 3,6 - 4,0 R T<strong>UV</strong>260XPT, T<strong>UV</strong>270XPT<br />

RS-EVG270W/3,8A 280 - 310 1,1 – 1,5 1 250 -280 3,6 - 4,0 T T<strong>UV</strong>260XPT, T<strong>UV</strong>270XPT<br />

R-EVG2x[270W]/3,8A 560 - 620 2,21 - 3 2 250 -280 3,6 - 4,0 S T<strong>UV</strong>260XPT, T<strong>UV</strong>270XPT<br />

RS-EVG2x[270W]/3,8A 560 - 620 2,21 - 3 2 250 -280 3,6 - 4,0 U T<strong>UV</strong>260XPT, T<strong>UV</strong>270XPT<br />

R-EVG300W/2,1A 350 1,38 - 1,7 1 320 2,1 - 2,4 R NNI300/147XL<br />

RS-EVG300W/2,1A 350 1,38 - 1,7 1 320 2,1 - 2,4 T NNI300/147XL<br />

R-EVG2x[300W]/2,1A 700 2,76 - 3,38 2 320 2,1 - 2,4 S NNI300/147XL<br />

RS-EVG2x[300W]/2,1A 700 2,76 - 3,38 2 320 2,1 - 2,4 U NNI300/147XL<br />

R-EVG320W/2,2A 350 1,38 - 1,7 1 320 2,1 - 2,4 R T<strong>UV</strong>325XPT<br />

RS-EVG320W/2,2A 350 1,38 - 1,7 1 320 2,1 - 2,4 T T<strong>UV</strong>325XPT<br />

R-EVG2x[320W]/2,2A 700 2,76 - 3,38 2 320 2,1 - 2,4 S T<strong>UV</strong>325XPT<br />

RS-EVG2x[320W]/2,2A 700 2,76 - 3,38 2 320 2,1 - 2,4 U T<strong>UV</strong>325XPT<br />

R-EVG400W/3,8A 425 1,7 - 2,1 1 400 3,8 R NNI400<br />

RS-EVG400W/3,8A 425 1,7 - 2,1 1 400 3,8 T NNI400<br />

R-EVG330W/4,8A 370 1,46 - 1,79 1 330 4,8 R T<strong>UV</strong>330XPT<br />

RS-EVG330W/4,8A 370 1,46 - 1,79 1 330 4,8 T T<strong>UV</strong>330XPT<br />

lamp type lamp watts [W] lamps per<br />

ballast<br />

ballast models ballast power<br />

[W]*<br />

ballast input<br />

current [A]<br />

GPHA1554T5L 196 1 R-E230.101 216 0,95 R<br />

GPHA1554T5L 196 1 RS-E230.101 216 0,95 T<br />

GPHA1554T5L 196 2 R-E230.201 432 1,8 S<br />

GPHA1554T5L 196 2 RS-E230.201 432 1,8 U<br />

GPHA1554T6L 240 1 R-230.102 261 1,14 R<br />

GPHA1554T6L 240 1 RS-230.102 261 1,14 T<br />

GPHA1554T6L 240 2 R-230.202 520 2,38 S<br />

GPHA1554T6L 240 2 RS-230.202 520 2,38 U<br />

GPHHA1000T6L 207 1 R-E230.110 218 0,96 R<br />

GPHHA1000T6L 207 1 RS-E230.110 218 0,96 T<br />

GPHHA1000T6L 207 2 R-E230.211 440 2 S<br />

GPHHA1000T6L 207 2 RS-E230.211 440 2 U<br />

GPHHA1554T6L 320 1 R-E230.103 340 1,52 R<br />

GPHHA1554T6L 320 1 RS-E230.103 340 1,52 T<br />

GPHHA1554T6L 320 2 R-E230.203 680 3,04 S<br />

GPHHA1554T6L 320 2 RS-E230.203 680 3,04 U<br />

ballast type<br />

Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Available <strong>Ballasts</strong><br />

ballast name input power<br />

[W]<br />

09/2006<br />

ballast type K<br />

ballast type N<br />

- 15 -<br />

input<br />

current [A]<br />

lamps per<br />

ballast<br />

power per<br />

lamp [W]<br />

lamp<br />

current [A]<br />

ballast<br />

type<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (4pin-type)<br />

microprocessor controlled<br />

200...350W/1,9...2,1A up to 500...900W/4...11A / 230V AC<br />

ballasts <strong>for</strong> one and two lamp operation <strong>for</strong> use with Digital Operation System<br />

suitable lamp types<br />

(manufacturer model)<br />

P-EVG2x[240W]/2A 440 - 500 1,74 - 2,42 2 220 -250 1,9 - 2,2 K UNI260, GIA240,<br />

T<strong>UV</strong>240WXPT<br />

P-EVG2x[300W]/2,1A 700 2,56 - 3,2 2 320 2,1 - 2,4 K NNI300/147XL<br />

P-EVG800W/7A 890 3,5 - 4,3 1 800 4 - 7 N<br />

P-EVG800W/11A 890 3,5 - 4,3 1 800 7 - 11 N<br />

Functions:<br />

• preheat start<br />

• switch-on current = operating current<br />

• input voltage control<br />

• undervoltage switch-off<br />

Technical Specification<br />

serial port control features:<br />

• connection of up to 256 devices via RS485,<br />

loop through possible<br />

• switch-on/-off<br />

• dimming: 50...100% with current<br />

compensation in the lamps filaments<br />

• preheating<br />

(cable-length compensation)<br />

• internal hourmeter<br />

• adjustment of several parameters<br />

• status readout<br />

mains voltage: 230V AC ± 10% CE-con<strong>for</strong>m: yes<br />

mains frequency: 45...65Hz tc-temperature: max. 50°C<br />

operating frequency: 30...100kHz ambient temperature: 0...40°C<br />

efficiency: > 90%<br />

status indication: green, yellow and red LED indicate operating status<br />

error code<br />

bus communication<br />

wire gauge: 0,75...1,5mm²<br />

mounting restrictions: upright, mains connector at bottom side, see manual <strong>for</strong> details<br />

Readout:<br />

• status (errors)<br />

• correct connection<br />

• lamp power<br />

• lamp voltage<br />

• dimming status<br />

• filament status<br />

• operation hours<br />

Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


09/2006<br />

ballast type D<br />

ballast type E<br />

ballast type F<br />

ballast type G<br />

ballast type H<br />

- 16 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (4pin-type)<br />

EVG 30...300W / 115V AC<br />

ballasts <strong>for</strong> one and <strong>for</strong> two lamp operation available<br />

PREHEAT START versions available on request (only <strong>for</strong> one lamp ballast type H)<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Technical Specification<br />

mains voltage: 115V AC ± 10% CE-con<strong>for</strong>m: yes<br />

mains frequency: 45...65Hz tc-temperature: max. 50°C<br />

operating frequency: 30...50kHz ambient temperature: 0...40°C<br />

efficiency: > 88%<br />

Available <strong>Ballasts</strong><br />

ballast name input power<br />

[W]<br />

ballast type H: also available as PREHEAT START version on request (add -PH to ballast name),<br />

ballasts <strong>for</strong> two lamps are also working if only one lamp is connected.<br />

09/2006<br />

- 17 -<br />

input<br />

current [A]<br />

lamps per<br />

ballast<br />

power per<br />

lamp [W]<br />

lamp<br />

current [A]<br />

ballast<br />

type<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (4pin-type)<br />

EVG 30...300W / 115V AC<br />

ballasts <strong>for</strong> one and <strong>for</strong> two lamp operation available<br />

PREHEAT START versions available on request (only <strong>for</strong> one lamp ballast type H)<br />

status indication: green and red LED indicate operating status<br />

potential free relay contact,<br />

type D, H load: 50...200mA at 24...230V AC; 50...500mA at 5...60V DC<br />

type E, F, G load: 50...200mA at 24...120V AC; 50...500mA at 5...60V DC<br />

wire gauge: type D: 0,5...1mm² / type E, F, G, H: 0,75...1,5mm²<br />

(type F: max. 0,75mm² <strong>for</strong> potential free relay contacts)<br />

mounting restrictions: upright, mains connector at bottom side, see manual <strong>for</strong> details<br />

suitable lamp types<br />

(manufacturer model)<br />

S-EVG30–50W/425mA -1 32 - 55 0,25 - 0,53 1 30 - 50 0,39 - 0,42 D G36T5, GPH793T5,<br />

T<strong>UV</strong>36T5<br />

EVG2x[30-50W]/425mA -1 up to 110 0,5 - 1,05 2 30 - 50 0,39 - 0,42 F G36T5, GPH793T5,<br />

T<strong>UV</strong>36T5<br />

EVG50–70W/425mA -1 55 – 75 0,43 - 0,72 1 50 - 70 0,39 - 0,42 E G64T5, T<strong>UV</strong>64T5<br />

EVG2x[50-70W]/425mA -1 up to 150 0,86 - 1,4 2 50 - 70 0,39 - 0,42 F G64T5, T<strong>UV</strong>64T5<br />

S-EVG35–45W/610mA -1 38 – 50 0,3 - 0,48 1 35 - 45 0,6 - 0,62 D GPH436T5HO<br />

EVG2x[35-45W]/610mA -1 up to 100 0,6 - 0,96 2 35 - 45 0,6 - 0,62 F GPH436T5HO<br />

EVG50–70W/670mA -1 55 – 75 0,43 - 0,72 1 50 – 70 0,65 – 0,7 E NNI60/25U<br />

EVG2x[50-70W]/670mA -1 up to 150 0,86 - 1,4 2 50 – 70 0,65 - 0,7 F NNI60/25U<br />

EVG50–70W/760mA -1 55 – 75 0,43 - 0,72 1 50 – 70 0,75 - 0,77 E GPH846T5HO, GPH893T5HO<br />

EVG2x[50-70W]/760mA -1 up to 150 0,86 - 1,4 2 50 – 70 0,75 - 0,77 F GPH846T5HO, GPH893T5HO<br />

EVG65–80W/880mA -1 70 – 85 0,55 - 0,8 1 65 – 80 0,85 – 0,9 E T<strong>UV</strong>36HO, T<strong>UV</strong>75,<br />

GHO36T5<br />

EVG2x[65-80W]/880mA -1 up to 170 1,1 - 1,6 2 65 – 80 0,85 - 0,9 G T<strong>UV</strong>36HO, T<strong>UV</strong>75,<br />

GHO36T5<br />

EVG150-200W/1A -1 160 – 220 1,26 - 2,1 1 150 0,8 - 1 E GHO64T5<br />

EVG100-150W/1,5A -1 110 - 160 0,86 - 1,55 1 100 - 150 1,4 - 1,5 E NNI80/36U, NNI120,<br />

UNI120, GIA120, T<strong>UV</strong>115<br />

EVG150-200W/1,5A -1 160 – 220 1,26 - 2,1 1 150 - 200 1,4 - 1,5 H GIA200, UNI201<br />

EVG160-200W/2A -1 175 – 220 1,4 - 2,1 1 160 - 200 1,85 – 2 H NNI200, NNI201, UNI200<br />

EVG240W/2A -1 250 - 280 2,0 - 2,7 1 220 - 250 1,9 - 2,2 H UNI260, GIA240,<br />

T<strong>UV</strong>240XPT<br />

EVG300W/2,1A -1 350 2,76 - 3,38 1 320 2,1 - 2,4 H NNI300/147XL<br />

Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Lamp Type Selection<br />

*values are depending on the temperature conditions of the lamps<br />

ballast type H: also available as PREHEAT START version on request, two step dimming on request<br />

09/2006<br />

ballast type D<br />

ballast type E<br />

ballast type H<br />

- 18 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

lamp type lamp watts [W] ballast models ballast power [W]* ballast input current ballast type<br />

[A]<br />

GPHA357T5L 42 S-E230.104 50 0,25 D<br />

GPHA842T5L 105 E230.101 118 0,53 E<br />

GPHA1000T5L 127 E230.101 140 0,62 E<br />

GPHA1554T5L 196 E230.101 216 0,95 E<br />

GPHA357T6L 57 S-E230.107 68 0,32 D<br />

GPHA842T6L 127 E230.108 140 0,62 E<br />

GPHA1000T6L 150 E230.108 164 0,74 E<br />

GPHA1554T6L 240 E230.102 261 1,14 H<br />

GPHHA357T6L 65 E230.110 74 0,35 E<br />

GPHHA842T6L 172 E230.110 180 0,79 E<br />

GPHHA1000T6L 207 E230.110 218 0,96 E<br />

GPHHA1554T6L 320 E230.103 340 1,52 H<br />

Technical Data<br />

mains voltage: 230V AC ± 10%, min.<br />

mains voltage 192V AC<br />

CE-con<strong>for</strong>m: yes efficiency: > 90%<br />

mains frequency: 45...65Hz tc-temperature: max. 50°C<br />

operating frequency: 30...50kHz ambient temperature: 0...40°C<br />

lamp fault indicator: green and red LED indicate operating status<br />

potential free relay contact,<br />

type E load: 50...200mA at 24...120V AC; 50...500mA at 5...60V DC<br />

type D, H load: 50...200mA at 24...230V AC; 50...500mA at 5...60V DC<br />

mounting restrictions: upright, mains connector at bottom side, see manual <strong>for</strong> details<br />

wire gauge: type D: 0,5...1mm², type E,H: 0,75...1,5 mm²<br />

Single <strong>Electronic</strong> <strong>Ballasts</strong> <strong>for</strong> Amalgam Lamps<br />

Special Design E230.1**<br />

<strong>for</strong> LightSources Inc. / LightTech Lamp Technology Ltd.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


09/2006<br />

ballast type F<br />

ballast type G<br />

ballast type I<br />

*values are depending on the temperature conditions of the lamps<br />

ballasts <strong>for</strong> two lamps are also working if only one lamp is connected<br />

- 19 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Twin <strong>Electronic</strong> <strong>Ballasts</strong> <strong>for</strong> Amalgam Lamps<br />

Special Design E230.2**<br />

<strong>for</strong> LightSources Inc. / LightTech Lamp Technology Ltd.<br />

Lamp Type Selection<br />

lamp type lamp watts ballast ballast power ballast input ballast type<br />

[W]<br />

models [W]*<br />

current [A]<br />

GPHA357T5L 42 E230.204 100 0,5 F<br />

GPHA842T5L 105 E230.205 236 1,04 G<br />

GPHA1000T5L 127 E230.205 280 1,24 G<br />

GPHA1554T5L 196 E230.201 432 1,8 G<br />

GPHA357T6L 57 E230.207 136 0,66 F<br />

GPHA842T6L 127 E230.208 280 1,24 G<br />

GPHA1000T6L 150 E230.208 328 1,48 G<br />

GPHA1554T6L 240 E230.202 520 2,38 I<br />

GPHHA357T6L 65 E230.210 148 0,7 F<br />

GPHHA842T6L 172 E230.210 360 1,64 G<br />

GPHHA1000T6L 207 E230.211 440 2 I<br />

GPHHA1554T6L 320 E230.203 680 3,04 I<br />

For type I ballasts<br />

step dimming is possible:<br />

Dimming<br />

DM1A DM0A lamp<br />

current<br />

0 0 100 %<br />

0 12 V DC 90 %<br />

12 V DC 0 80 %<br />

12 V DC 12 V DC 70 %<br />

Same diagram <strong>for</strong> lamp B,<br />

current approx. 1mA @ 12V DC<br />

(voltage range: 9-25V DC)<br />

Technical Data<br />

mains voltage: 230V AC ± 10%, min.<br />

mains voltage 192V AC<br />

CE-con<strong>for</strong>m: yes efficiency: > 90%<br />

mains frequency: 45...65Hz tc-temperature: max. 50°C<br />

operating frequency: 30...50kHz ambient temperature: 0...40°C<br />

lamp fault indicator: green and red LED indicate operating status<br />

potential free relay contact,<br />

type F, G load: 50...200mA at 24...120V AC; 50...500mA at 5...60V DC<br />

type I load: 50...200mA at 24...230V AC; 50...500mA at 5...60V DC<br />

mounting restrictions: upright, mains connector at bottom side, see manual <strong>for</strong> details<br />

wire gauge: 0,75...1,5 mm² (type F: max. 0,75 mm² <strong>for</strong> terminal 4-9, type I : 0,35...0,5 mm² <strong>for</strong> terminal 4-9 and 14-19)<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


allast name input power<br />

[W]<br />

09/2006<br />

- 20 -<br />

input current<br />

[A]<br />

lamp power<br />

[W]<br />

lamp current<br />

[A]<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

lamp type<br />

<strong>UV</strong>-Compact MC 30-50W/425mA OS 35 - 55 0,13 - 0,22 30 - 50 0,39 - 0,42 G36T5, GPH793T5, T<strong>UV</strong>25,<br />

T<strong>UV</strong>36T5, GPH846T5<br />

<strong>UV</strong>-Compact MC 50-70W/425mA OS 55 - 80 0,22 - 0,3 50 - 70 0,39 - 0,42 G64T5, T<strong>UV</strong>64T5<br />

<strong>UV</strong>-Compact MC 35-45W/610mA OS 40 - 50 0,15 - 0,2 35 - 45 0,6 - 0,62 GPH436T5HO<br />

<strong>UV</strong>-Compact MC 50-70W/670mA OS 55 - 80 0,22 - 0,3 50 - 70 0,65 - 0,7 NNI60/25U, T<strong>UV</strong>60PLL<br />

<strong>UV</strong>-Compact MC 50-70W/760mA OS 55 - 80 0,22 - 0,3 50 - 70 0,75 - 0,77 GPH846T5HO, GPH893T5HO,<br />

T<strong>UV</strong>55<br />

<strong>UV</strong>-Compact MC 65-80W/880mA OS 70 - 90 0,28 - 0,35 65 - 80 0,85 - 0,9 GHO36T5, T<strong>UV</strong>36HO, T<strong>UV</strong>75<br />

<strong>UV</strong>-Compact MC 150-200W/1A OS 160 – 220 0,65 - 0,9 150 - 200 0,8 – 1 GHO64T5, T<strong>UV</strong>64T5HO<br />

<strong>UV</strong>-Compact MC 40-60W/1,2A OS 45 - 65 0,17 - 0,26 40 - 60 1 - 1,2 UNI40, UNI60<br />

<strong>UV</strong>-Compact MC 100-150W/1,5A OS 110 - 170 0,43 - 0,65 100 - 150 1,4 - 1,5 GIA120, NNI120, NNI80/36U,<br />

UNI120<br />

<strong>UV</strong>-Compact MC 150-200W/1,5A OS 160 - 220 0,65 - 0,87 150 - 200 1,4 - 1,5 GIA200, UNI201<br />

<strong>UV</strong>-Compact MC 160-200W/2A OS 180 - 220 0,7 - 0,87 160 - 200 1,85 - 2 NNI200, UNI200<br />

Features<br />

• integrated electronic ballast<br />

<strong>for</strong> uv-lamps<br />

• hour counter<br />

• temperature monitoring<br />

• synchronous readout of state,<br />

operating hours, time and date<br />

• multicolour backlighting<br />

(red, green, yellow) <strong>for</strong> additional<br />

status-indication<br />

• menu lock<br />

Technical Specification<br />

mains voltage: 230V AC ± 10% CE-con<strong>for</strong>m: yes<br />

mains frequency: 45...65Hz ambient<br />

temperature:<br />

0...40°C<br />

operating frequency: 30...50kHz efficiency: > 90%<br />

display: 4*20 digits, green, yellow or red back lighting <strong>for</strong> status indication, adjustment of contrast by menu<br />

handling: menu-driven handling and programming by 4 push-buttons<br />

language: alternatively English or German (other languages on request)<br />

dimensions (w/h/l): (190/72/180)mm weight: 1900g<br />

connections: mains: line cord, cable length 2m<br />

<strong>Electronic</strong> Ballast with Integrated Hour Counter,<br />

Multicolour Display<br />

<strong>UV</strong>-Compact MC 30...200W OS, 230V AC<br />

hour counter:<br />

• internal real time clock<br />

• global hour counter<br />

• switch cycle counter<br />

• programmable user hour counter<br />

• adjustable end of lamp lifetime alarm<br />

temperature monitoring:<br />

• measurement of internal temperature<br />

• internal temperature<br />

can be monitored via menu<br />

• message ’’internal overheating’’ and<br />

system shutdown in case of<br />

temperature above<br />

certain switching thresholds<br />

• automatic restart<br />

can be defined by customer<br />

lamp: Hirschmann cable socket CA6GD<br />

(Hirschmann cable plug CA6LS is element of delivery, see drawing <strong>for</strong> connector pin list)<br />

protective earth: cable green/yellow, length 2m<br />

protection class: IP54 if lamp is connected by appropriated plug<br />

<strong>for</strong> use in one-lamp systems<br />

Please note the technical advices and the installation and operating instructions in the <strong>UV</strong>-Compact MC - Documentation.<br />

For use in chemical and biological inactive environment only! To be installed by specialized staff.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


allast name input power<br />

[W]<br />

09/2006<br />

- 21 -<br />

input current<br />

[A]<br />

lamp power<br />

[W]<br />

lamp current<br />

[A]<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

lamp type<br />

<strong>UV</strong>-Compact MC 30-50W/425mA 35 - 55 0,13 - 0,22 30 - 50 0,39 - 0,42 G36T5, GPH793T5, T<strong>UV</strong>25,<br />

T<strong>UV</strong>36T5, GPH846T5<br />

<strong>UV</strong>-Compact MC 50-70W/425mA 55 - 80 0,22 - 0,3 50 - 70 0,39 - 0,42 G64T5, T<strong>UV</strong>64T5<br />

<strong>UV</strong>-Compact MC 35-45W/610mA 40 - 50 0,15 - 0,2 35 - 45 0,6 - 0,62 GPH436T5HO<br />

<strong>UV</strong>-Compact MC 50-70W/670mA 55 - 80 0,22 - 0,3 50 - 70 0,65 - 0,7 NNI60/25U, T<strong>UV</strong>60PLL<br />

<strong>UV</strong>-Compact MC 50-70W/760mA 55 - 80 0,22 - 0,3 50 - 70 0,75 - 0,77 GPH846T5HO, GPH893T5HO,<br />

T<strong>UV</strong>55<br />

<strong>UV</strong>-Compact MC 65-80W/880mA 70 - 90 0,28 - 0,35 65 - 80 0,85 - 0,9 GHO36T5, T<strong>UV</strong>36HO, T<strong>UV</strong>75<br />

<strong>UV</strong>-Compact MC 150-200W/1A 160 – 220 0,65 - 0,9 150 - 200 0,8 – 1 GHO64T5, T<strong>UV</strong>64T5HO<br />

<strong>UV</strong>-Compact MC 40-60W/1,2A 45 - 65 0,17 - 0,26 40 - 60 1 - 1,2 UNI40, UNI60<br />

<strong>UV</strong>-Compact MC 100-150W/1,5A 110 - 170 0,43 - 0,65 100 - 150 1,4 - 1,5 GIA120, NNI120, NNI80/36U,<br />

UNI120<br />

<strong>UV</strong>-Compact MC 150-200W/1,5A 160 - 220 0,65 - 0,87 150 - 200 1,4 - 1,5 GIA200, UNI201<br />

<strong>UV</strong>-Compact MC 160-200W/2A 180 - 220 0,7 - 0,87 160 - 200 1,85 - 2 NNI200, UNI200<br />

Features<br />

• integrated electronic ballast<br />

• hour counter<br />

• temperature monitoring<br />

• uv-value monitoring<br />

• synchronous readout of<br />

• uv-value, uv-state, operating hours,<br />

time and date<br />

• multicolour backlighting (red, green,<br />

yellow) <strong>for</strong> additional status-indication<br />

• menu lock<br />

<strong>Electronic</strong> Ballast with Integrated Hour Counter and <strong>UV</strong>-Monitor,<br />

Multicolour Display<br />

<strong>UV</strong>-Compact MC 30...200W, 230V AC<br />

hour counter:<br />

• internal real time clock<br />

• global hour/switch cycle counter<br />

• programmable user hour counter<br />

• adjustable end of lamp lifetime alarm<br />

temperature monitoring:<br />

• measurement of internal temperature<br />

• internal temperature<br />

can be monitored via menu<br />

• message ’’internal overheating’’ and<br />

system shutdown in case of<br />

Technical Specification<br />

mains voltage: 230V AC ± 10% CE-con<strong>for</strong>m: yes<br />

mains frequency: 45...65Hz ambient<br />

temperature:<br />

0...40°C<br />

operating frequency: 30...50kHz efficiency: > 90%<br />

display: 4*20 digits, green, yellow or red back lighting <strong>for</strong> status indication, adjustment of contrast by menu<br />

handling: menu-driven handling and programming by 4 push-buttons<br />

language: alternatively English or German (other languages on request)<br />

dimensions (w/h/l): (190/72/180)mm weight: 1900g<br />

connections: mains: line cord, cable length 2m<br />

<strong>for</strong> use in one-lamp systems<br />

temperature above<br />

certain switching thresholds<br />

• automatic restart<br />

can be defined by customer<br />

<strong>UV</strong>-value monitoring:<br />

• to be enabled/disabled by customer<br />

• relative uv-intensity (in %)<br />

• adjustable uv-low alarm<br />

(two steps: pre alarm - yellow /<br />

main alarm - red backlighting)<br />

• automatic adjustment of sensitivity<br />

uv-sensor: sensor cable, length 1m, with Hirschmann cable plug ELST 5012 (see drawing <strong>for</strong> connector pin list)<br />

lamp: Hirschmann cable socket CA6GD<br />

(Hirschmann cable plug CA6LS is element of delivery, see drawing <strong>for</strong> connector pin list)<br />

protective earth: cable green/yellow, length 2m<br />

protection class: IP54 if lamp and sensor are connected by appropriated plugs<br />

recommended<br />

SiC001-uv-compact, SiC003-uv-compact, SiC007-P-uv-compact with measurement window MF001<br />

sensor types:<br />

Please note the technical advices and the installation and operating instructions in the <strong>UV</strong>-Compact MC - Documentation.<br />

For use in chemical and biological inactive environment only! To be installed by specialized staff.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


allast name input power<br />

[W]<br />

09/2006<br />

- 22 -<br />

input current<br />

[A]<br />

lamp power<br />

[W]<br />

lamp current<br />

[A]<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> Ballast with Integrated Hour Counter and <strong>UV</strong>-Monitor<br />

Multicolour Display, Active Cooling<br />

<strong>UV</strong>-Compact MCplus 200...350W, 230V AC<br />

lamp type<br />

<strong>UV</strong> Compact MCplus 200W/2A 220 0,79 - 0,97 200 1,85 - 2 NNI201/107XL<br />

<strong>UV</strong> Compact MCplus 240W/2A 270 - 310 0,87 - 1,21 250 - 280 1,9 - 2,2 GIA240, UNI260<br />

<strong>UV</strong> Compact MCplus 300W/2,1A 360 1,28 - 1,6 320 2,1...2,4 NNI300/147XL<br />

<strong>UV</strong> Compact MCplus 320W/2,2A 360 1,28 - 1,6 320 2,1...2,4 T<strong>UV</strong>325XPT<br />

<strong>UV</strong> Compact MCplus E230.111 218 0,86 - 1,05 207 GPHHA1000T6L<br />

<strong>UV</strong> Compact MCplus E230.102 261 1,03 - 1,26 240 GPHA1554T6L<br />

<strong>UV</strong> Compact MCplus E230.103 340 1,34 - 1,64 320 GPHHA1554T6L<br />

Features<br />

• integrated electronic ballast<br />

<strong>for</strong> uv-lamps<br />

• hour counter<br />

• uv-value monitoring<br />

• temperature monitoring<br />

• integrated fan <strong>for</strong> active cooling<br />

• synchronous readout<br />

of uv-value, uv-state, operating<br />

hours, time and date<br />

• multicolour backlighting<br />

(red, green, yellow) <strong>for</strong> additional<br />

status-indication<br />

• menu lock<br />

hour counter:<br />

• internal real time clock<br />

• global hour counter<br />

• switch cycle counter<br />

• programmable user hour counter<br />

• adjustable end of lamp lifetime alarm<br />

<strong>UV</strong>-value monitoring:<br />

• to be enabled/disabled by customer<br />

• relative uv-intensity (in %)<br />

• adjustable uv-low alarm (two steps:<br />

pre alarm/main alarm<br />

• automatic adjustment of sensitivity<br />

<strong>for</strong> use in one-lamp systems<br />

temperature monitoring:<br />

• measurement of internal temperature<br />

(optional external temperature)<br />

• internal temperature can be monitored<br />

via menu<br />

• message ’’internal overheating’’ and<br />

system shutdown in case of temperature<br />

above certain switching thresholds<br />

• automatic restart can be defined by<br />

customer<br />

Technical Specification<br />

mains voltage: 230V AC ± 10% CE-con<strong>for</strong>m: yes<br />

mains frequency: 45...65Hz ambient<br />

temperature:<br />

0...40°C<br />

operating frequency: 30...50kHz efficiency: > 90%<br />

display: 4*20 digits, green, yellow or red back lighting <strong>for</strong> status indication, adjustment of contrast by menu<br />

handling: menu-driven handling and programming by 4 push-buttons<br />

language: alternatively English or German (other languages on request)<br />

dimensions (w/h/l): (190/72/180)mm weight: 2000g<br />

connections: mains: line cord, cable length 2m<br />

uv-sensor: BNC-socket<br />

protection class:<br />

lamp: 4wire lamp cable, length 2m provided with 4pin ceramic type lamp socket<br />

protective earth: cable green/yellow, length 2m<br />

IP00<br />

recommended<br />

SiC001-PG-BNC, SiC003-PG-BNC, SiC007-P-PG-BNC with measurement window MF001,<br />

sensor types:<br />

SLS-SiC003-PG-BNC, SLS-SiC004-PG-BNC<br />

(2wire cable with BNC-connector, shielded, length 2,0m)<br />

Please note the technical advices and the installation and operating instructions in the <strong>UV</strong>-Compact MCplus - Documentation.<br />

For use in chemical and biological inactive environment only! To be installed by specialized staff.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


09/2006<br />

ballast type A<br />

ballast type B<br />

Available <strong>Ballasts</strong><br />

Technical Specification<br />

ballast type C<br />

ballast name input voltage<br />

[V]<br />

- 23 -<br />

input input power per<br />

power [W] current [A] lamp [W]<br />

*power supply requirements <strong>for</strong> 24V DC ballast: stabilised, short-circuit proof, inrush current 1,5A min.<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (2pin-type)<br />

EVG 11W...20W<br />

230V AC / 115V AC / 24V DC<br />

lamp<br />

current [A]<br />

ST-EVG 11/20 IS 230V AC ± 10% up to 24 0,05 - 0,11 11-20 0,425 ± 10% C<br />

EVG11-20W/425mA IS 230V AC ± 10% up to 24 0,05 - 0,11 11-20 0,425 ± 10% A<br />

EVG11-20W/425mA IS -1 115V AC ± 10% up to 24 0,11 - 0,23 11-20 0,425 ± 10% A<br />

EVG11-20W/425mA IS -4 24V* DC ± 10% up to 24 0,47 - 1,1 11-20 0,425 ± 10% B<br />

ballast<br />

type<br />

suitable lamp types<br />

(manufacturer model)<br />

T<strong>UV</strong>16,<br />

GPH287T5L,<br />

GPH303T5L<br />

mains frequency: 45...65Hz tc-temperature: max. 50°C CE-con<strong>for</strong>m: yes<br />

operating frequency: 30...50kHz ambient temperature: 0...40°C efficiency: ca. 85%<br />

max. off-load voltage<br />

on terminals 1...4:<br />

type A: 1.5kVpp , type B: 600Vrms status indication: green and red LED indicate operating status,<br />

type C: buzzer sounds up if the lamp is not working<br />

photocoupler, max. current on OG: 5mA (open collector VOG1/0


02/2007<br />

ballast type D<br />

ballast type E<br />

ballast type F<br />

ballast type G<br />

ballast type J<br />

(4 lamp - ballast)<br />

- 24 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (2pin-type)<br />

EVG 20...200W / 230V AC, instant start<br />

ballasts <strong>for</strong> one, two and four lamp operation available<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Available <strong>Ballasts</strong><br />

ballast name input power<br />

[W]<br />

02/2007<br />

ballast type L<br />

- 25 -<br />

input<br />

current [A]<br />

lamps per<br />

ballast<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (2pin-type)<br />

EVG 20...200W / 230V AC, instant start<br />

ballasts <strong>for</strong> one, two and four lamp operation available<br />

power per<br />

lamp [W]<br />

lamp<br />

current [A]<br />

ballast<br />

type<br />

suitable lamp types<br />

(manufacturer model)<br />

S-EVG30-50W/425mA IS 35 - 55 0,14 - 0,26 1 30 - 50 0,39 - 0,42 D G36T5, GPH793T5,<br />

T<strong>UV</strong>36SPT5<br />

EVG2x[30-50W]/425mA IS up to 110 0,28 - 0,52 2 30 - 50 0,39 - 0,42 F G36T5, GPH793T5,<br />

T<strong>UV</strong>36SPT5<br />

S-EVG50-70W/425mA IS 55 – 75 0,22 - 0,36 1 50 - 70 0,39 - 0,42 D G64T5, T<strong>UV</strong>64SPT5<br />

EVG2x[50-70W]/425mA IS up to 160 0,44 - 0,7 2 50 - 70 0,39 - 0,42 F G64T5, T<strong>UV</strong>64SPT5<br />

S-EVG35-45W/610mA IS 38 – 50 0,15 - 0,24 1 35 - 45 0,6 - 0,62 D GPH436T5HO<br />

EVG2x[35-45W]/610mA IS up to 100 0,3 - 0,48 2 35 - 45 0,6 - 0,62 F GPH436T5HO<br />

EVG4x[20W]/425mA IS up to 85 0,33 - 0,41 4 20 0,42 J GPH436T5L<br />

EVG4x[40W]/425mA IS up to 170 0,65 - 0,8 4 35 0,42 J G36T5, GPH793T5,<br />

T<strong>UV</strong>SP36T5<br />

S-EVG50-70W/760mA IS 55 – 75 0,22 - 0,36 1 50 - 70 0,75 - 0,77 D GPH846T5HO, GPH893T5HO<br />

EVG2x[50-70W]/760mA IS up to 150 0,44 - 0,7 2 50 - 70 0,75 - 0,77 F GPH846T5HO, GPH893T5HO<br />

S-EVG65-80W/880mA IS 70 – 85 0,28 - 0,41 1 65 - 80 0,85 - 0,9 D T<strong>UV</strong>36HO, GHO36T5<br />

EVG2x[65-80W]/880mA IS up to 170 0,56 - 0,8 2 65 - 80 0,85 - 0,9 F T<strong>UV</strong>36HO, GHO36T5<br />

EVG4x[150W]/1A IS up to 650 2,6 - 3,1 4 150 0,8 - 1,0 L T<strong>UV</strong>64T5HO, GHO64T5<br />

EVG150-200W/1A IS 165 – 220 0,65 - 0,97 1 150 - 200 0,8 - 1,0 E GHO64T5<br />

EVG2x[150-200W]/1A IS up to 440 1,3 - 1,9 2 150 - 200 0,8 - 1,0 G GHO64T5<br />

<strong>Ballasts</strong> <strong>for</strong> two or four lamps are also working if not all lamps are connected.<br />

Technical Specification<br />

mains voltage: 230V AC ± 10% CE-con<strong>for</strong>m: yes efficiency: > 90%<br />

mains frequency: 45...65Hz tc-temperature: max. 50°C<br />

operating frequency: 30...50kHz ambient temperature: 0...40°C<br />

status indication: green and red LED indicate operating status<br />

potential free relay contact,<br />

type D, L load: 50...200mA at 24...230V AC; 50...500mA at 5...60V DC<br />

type E, F, G, J load: 50...200mA at 24...120V AC; 50...500mA at 5...60V DC<br />

wire gauge: type D: 0,5...1mm² / type E, F, G, J, L: 0,75...1,5mm² (max. 0,75mm² <strong>for</strong> potential free relay contacts)<br />

mounting restrictions: upright, mains connector at bottom side, see manual <strong>for</strong> details<br />

Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


09/2006<br />

ballast type D<br />

ballast type E<br />

ballast type F<br />

ballast type G<br />

Technical Specification<br />

- 26 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (2pin-type)<br />

EVG 30...150W / 115V AC, instant start<br />

ballasts <strong>for</strong> one and two lamp operation available<br />

mains voltage: 115V AC ± 10% CE-con<strong>for</strong>m: yes efficiency: > 90%<br />

mains frequency: 45...65Hz tc-temperature: max. 50°C<br />

operating frequency: 30...50kHz ambient temperature: 0...40°C<br />

status indication: green and red LED indicate operating status<br />

potential free relay contact,<br />

type D load: 50...200mA at 24...230V AC; 50...500mA at 5...60V DC<br />

type E, F, G load: 50...200mA at 24...120V AC; 50...500mA at 5...60V DC<br />

wire gauge: type D: 0,5...1mm², type E, F, G: 0,75...1,5mm² (type F: max. 0,75mm² <strong>for</strong> potential free relay contacts)<br />

mounting restrictions: upright, mains connector at bottom side, see manual <strong>for</strong> details<br />

see next page <strong>for</strong> list of ballasts ⇒<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Available <strong>Ballasts</strong><br />

ballast name input power<br />

[W]<br />

ballasts <strong>for</strong> two lamps are also working if only one lamp is connected.<br />

09/2006<br />

- 27 -<br />

input<br />

current [A]<br />

lamps per<br />

ballast<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>Electronic</strong> <strong>Ballasts</strong> (2pin-type)<br />

EVG 30...150W / 115V AC, instant start<br />

power per<br />

lamp [W]<br />

ballasts <strong>for</strong> one and two lamp operation available<br />

lamp<br />

current [A]<br />

ballast<br />

type<br />

suitable lamp types<br />

(manufacturer model)<br />

S-EVG30-50W/425mA IS-1 32 - 55 0,25 - 0,53 1 30 – 50 0,39 - 0,42 D G36T5, GPH793T5,<br />

T<strong>UV</strong>36T5<br />

EVG2x[30–50W]/425mA IS-1 up to 110 0,5 - 1,05 2 30 – 50 0,39 – 0,42 F G36T5, GPH793T5,<br />

T<strong>UV</strong>36T5<br />

EVG50-70W/425mA IS-1 55 – 75 0,43 - 0,72 1 50 – 70 0,39 - 0,42 E G64T5, T<strong>UV</strong>64T5<br />

EVG2x[50–70W]/425mA IS-1 up to 150 0,86 - 1,4 2 50 – 70 0,39 – 0,42 F G64T5, T<strong>UV</strong>64T5<br />

S-EVG35-45W/610mA IS-1 38 – 50 0,3 - 0,48 1 35 – 45 0,6 - 0,62 D GPH436T5HO<br />

EVG2x[35–45W]/610mA IS-1 up to 100 0,6 - 0,96 2 35 – 45 0,6 – 0,62 F GPH436T5HO<br />

EVG50-70W/760mA IS-1 55 – 75 0,43 - 0,72 1 50 – 70 0,75 - 0,77 E GPH846T5HO, GPH893T5HO<br />

EVG2x[50–70W]/760mA IS-1 up to 150 0,86 - 1,4 2 50 – 70 0,75 – 0,77 F GPH846T5HO, GPH893T5HO<br />

EVG65-80W/880mA IS-1 70 – 85 0,55 - 0,8 1 65 – 80 0,85 - 0,9 E T<strong>UV</strong>36HO, T<strong>UV</strong>75,<br />

GHO36T5<br />

EVG2x[65–80W]/880mA IS-1 up to 170 1,1 - 1,6 2 65 – 80 0,85 – 0,9 G T<strong>UV</strong>36HO, T<strong>UV</strong>75,<br />

GHO36T5<br />

EVG150–200W/1A IS-1 160 – 220 1,26 - 2,1 1 150 -200 0,8 – 1 E GHO64T5<br />

Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Technical Specification<br />

mains voltage: ESBS01-1: 115V AC ± 10%<br />

ESBS01: 230V AC ± 10%<br />

dimensions<br />

(w/h/l):<br />

device delay<br />

switch settings:<br />

09/2006<br />

- 28 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Accessories <strong>for</strong> <strong>Electronic</strong> <strong>Ballasts</strong><br />

Starting Component ESBS01-1/ESBS01<br />

<strong>for</strong> delayed power-on of 4 electronic ballasts (delay time selectable from 0...12s) by DIP-switch),<br />

extensible up to 4 starting components/16 electronic ballasts by cascading<br />

mains frequency: 45...65Hz max. constant<br />

input current<br />

of ballasts<br />

(complete):<br />

(97/43/96) mm weight: 400g (0,881lbs)<br />

S1 on: 0s | S3 on: 8s<br />

S2 on: 4s | S4 on: 12s<br />

Example <strong>for</strong> wiring and switching:<br />

ballast switching<br />

time:<br />

ballast 1: device delay +0s | ballast 3: device delay +2s<br />

ballast 2: device delay +1s | ballast 4: device delay +3s<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com<br />

6A


09/2006<br />

- 29 -<br />

<strong>UV</strong>-Monitor PRO 2<br />

with status indication by LED<br />

<strong>UV</strong>-Monitor PRO 3<br />

with relay contacts and status indication by LED<br />

<strong>UV</strong>-Monitor PRO 5<br />

with relay contacts and status indication by LED<br />

<strong>UV</strong>-Monitor PRO 8<br />

with relay contacts and status indication by LED<br />

<strong>UV</strong>-Monitor PRO 10.4<br />

with relay contacts, status indication by LED and LCD<br />

and integrated hour counter<br />

<strong>UV</strong>-Monitor PRO 11<br />

with relay contacts, status indication by LCD<br />

and integrated hour counter<br />

synchronous readout of uv-value and operating hours<br />

LCD with green and red back lighting <strong>for</strong> status indication<br />

<strong>UV</strong>-Monitor PRO 15<br />

with relay contacts, status indication by LCD<br />

and integrated hour counter<br />

synchronous readout of uv-value and operating hours<br />

<strong>UV</strong>-Monitor PRO 16<br />

with relay contacts, status indication by LCD<br />

and integrated hour counter<br />

synchronous readout of uv-value and operating hours<br />

LCD with green and red back lighting <strong>for</strong> status indication<br />

<strong>UV</strong>-Monitor PRO 20 / PRO 20-S<br />

<strong>for</strong> analog and digital multi-sensoring<br />

with relay contacts, status indication by LCD<br />

and integrated hour counter<br />

synchronous readout of uv-value and operating hours<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Monitors - Overview<br />

<strong>for</strong> monitoring of the relative and/or absolute uv-intensity<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


09/2006<br />

PRO2<br />

PRO3<br />

PRO5<br />

- 30 -<br />

PRO8<br />

PRO10.4<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

Recommended Measurement Combinations<br />

of Sensors and Monitors<br />

Please note: We offer the adjustment of the sensors according to your requirements.<br />

PRO10.4-U2<br />

PRO10.4-SLS<br />

PRO11PI-I<br />

PRO11PU3-I<br />

SiC-SV01 x x x x x x x x x x x x x x x x<br />

SiC001 x x x x x x x x x x x x x x x x<br />

SiC001-PG x x x x x x x x x x x x x x x x<br />

SiCT001-PG x x x x x x x x x x x x x x x x<br />

SiC003 x x x x x x x x x x x x x x x x<br />

SiC003-PG x x x x x x x x x x x x x x x x<br />

SLS-SiC003 x x<br />

SLS-SiC003-PG x x<br />

SLS-SiC004 x x<br />

SLS-SiC004-PG x x<br />

SiC007-P x x x x x x x x x x x x x x x x<br />

SiC007-P-PG x x x x x x x x x x x x x x x x<br />

SiC007-I x x x x x<br />

SiC007-I-PG x x x x x<br />

SiC007-U2 x x<br />

SiC007-U2-PG x x<br />

SiC007-U3 x x x x<br />

SiC007-U3-PG x x x x<br />

SiC007-U10 x<br />

SiC007-U10-PG x<br />

SiC021-I x x x x x<br />

SiC021-I-PG x x x x x<br />

SiC021-U2 x x<br />

SiC021-U2-PG x x<br />

SiC021-U3 x x x x<br />

SiC021-U3-PG x x x x<br />

SiC021-U10 x<br />

SiC021-U10-PG x<br />

SiCDVGW001-LP x x<br />

SiCDVGW001-MP x x<br />

SiCDVGW002-LP x x x x x<br />

SiCDVGW002-MP x x x x x<br />

SiCONORM001-LP x x<br />

SiCONORM001-MP x x<br />

SiCONORM002-LP x x x x x<br />

SiCONORM002-MP x x x x x<br />

Sensors and Monitors <strong>for</strong> the Digital Operation System<br />

Digital Sensors Accessories <strong>UV</strong>-Monitors<br />

D-SiC003(-PG)(-F) Interface IF03<br />

PRO11<br />

D-SLS-SiC003(-PG)(-F)<br />

D-SLS-SiC004(-PG)(-F)<br />

<strong>for</strong> connection of<br />

analog (uv-diode output)sensors:<br />

PRO16<br />

PRO20<br />

D-SiC007(-PG)(-F) SiC-SV01 PLC<br />

D-SiC021(-PG)(-F) SiC001(-PG)<br />

D-SiCDVGW SiCT001-PG<br />

D-SiCONORM SiC003(-PG)<br />

SiC007-P(-PG)<br />

PRO15<br />

PRO15-SLS<br />

PRO16P<br />

PRO16I(-I)<br />

PRO16U3(-I)<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com<br />

PRO16PI(-I)<br />

PRO16PU3(-I)<br />

PRO20<br />

<strong>UV</strong>-Compact<br />

IF01<br />

IF02<br />

IF03


09/2006<br />

PRO 2<br />

PRO 3<br />

Available Monitor Types<br />

monitor<br />

type<br />

Functions:<br />

• display of the relative uv-output with three<br />

LED's:<br />

� GREEN: function o.k.<br />

� YELLOW: pre-alarm<br />

� RED: main alarm<br />

Attention: Risk of electric shock!<br />

- 31 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Monitor PRO 2 with Status Indication by LED<br />

<strong>UV</strong>-Monitor PRO 3 with Relay Contacts and Status Indication by LED<br />

<strong>for</strong> monitoring of the relative uv-intensity, e.g. in uv disinfection systems<br />

sensor signal relay contact weight suitable sensor types<br />

PRO2 diode output no relay contact 120g SiC-SV01,<br />

PRO3 diode output potential free relay contact, load:<br />

5mA...1A/5V...230V AC<br />

5mA...1A/5V...60V DC<br />

relay threshold 50%<br />

Technical Specification<br />

mains voltage: 230V AC ± 10% /50/60 Hz<br />

(115V AC/60Hz or 24V DC<br />

types available on request)<br />

• PRO 3: potential free relay contact<br />

in accordance with status indication<br />

<strong>for</strong> main alarm<br />

• multi turn potentiometer <strong>for</strong> fine<br />

adjustment of sensitivity at 110%,<br />

shown through a green LED nearby the<br />

potentiometer<br />

operating<br />

temperature:<br />

measurement range: adjustable <strong>for</strong> customer purpose by manufacturer<br />

status indication: 3 LED:<br />

green: function o.k.<br />

yellow: pre-alarm<br />

red: main alarm<br />

switching<br />

thresholds:<br />

The device must be installed in a closed cabinet, otherwise lethal parts can be touched by hand.<br />

The device may be installed by authorized personnel only, to make sure all applicable safety rules are fulfilled.<br />

Please consider the safety instructions in the installation and operating manual.<br />

0...40°C storage<br />

temperature<br />

range:<br />

red: 0 - 49% (main alarm)<br />

yellow: 50 - 74% (pre-alarm)<br />

green: > 74% (function o.k.)<br />

(or customers specification)<br />

dimensions (w/h/l): (75/49/41)mm mounting: 4 mounting holes ∅ 3,8mm<br />

hole center distance: (65 x 38)mm<br />

150g<br />

SiCT001-PG,<br />

SiC001(-PG),<br />

SiC003(-PG),<br />

SiC007-P(-PG)<br />

-40°C...+70°C<br />

For use in dry environment only!<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Available Monitor Types<br />

monitor<br />

type<br />

09/2006<br />

sensor<br />

signal<br />

PRO5-PF diode<br />

output<br />

PRO5 diode<br />

output<br />

PRO8 diode<br />

output<br />

suitable<br />

sensor<br />

types<br />

SiC-SV01,<br />

SiCT001-PG,<br />

SiC001,<br />

SiC001-PG,<br />

SiC003,<br />

SiC003-PG,<br />

SiC007-P,<br />

SiC007-P-PG<br />

PRO 5-PF<br />

PRO 8<br />

switching<br />

thresholds<br />

red: 0...49%<br />

(main alarm)<br />

yellow:<br />

50...74%<br />

(pre-alarm)<br />

green: > 74%<br />

(function o.k.)<br />

(or customers<br />

specification)<br />

Functions<br />

• display of the relative uv-output with three<br />

LED's:<br />

� GREEN: function o.k.<br />

� YELLOW: pre-alarm<br />

� RED: main alarm<br />

- 32 -<br />

PRO 5<br />

Technical Specification<br />

mains voltage: 230V AC ± 10% /50/60 Hz<br />

(115V AC/60Hz or 24V DC types<br />

available on request)<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Monitor PRO 5/ PRO 8 with Relay Contacts<br />

and Status Indication by LED<br />

<strong>for</strong> monitoring of the relative uv-intensity, e.g. in uv disinfection systems<br />

relay contact load potentiometer<br />

<strong>for</strong> fine adjustment<br />

50...200mA/24V...230V AC<br />

100...500mA/24V...60V DC<br />

50...200mA/24V...230V AC<br />

100...500mA/24V...60V DC<br />

50...200mA/24V...230V AC<br />

50...500mA/24V...60V DC<br />

• potential free relay contacts in accordance<br />

with status indication:<br />

� PRO 5: main alarm<br />

� PRO 8: pre-alarm, main alarm<br />

operating<br />

temperature:<br />

measurement range: adjustable <strong>for</strong> customer purpose in wide range<br />

status indication: LED green: function o.k.<br />

LED yellow: pre-alarm<br />

LED red: main alarm<br />

relay contact<br />

<strong>for</strong> alarm:<br />

Accessories - cover <strong>for</strong> uv monitors <strong>for</strong> protection level IP65 at front<br />

cover <strong>for</strong><br />

<strong>UV</strong>-Monitor PRO5<br />

dimensions<br />

(w/h/l):<br />

at front side (72/72/77)<br />

mm<br />

at back side (72/72/77)<br />

mm<br />

at back side (96/48/80)<br />

mm<br />

mounting weight<br />

cut-out<br />

according<br />

DIN43700<br />

(68 +0,7 x 68 +0,7 )<br />

cut-out<br />

according<br />

DIN43700<br />

(68 +0,7 x 68 +0,7 )<br />

cut-out<br />

according<br />

DIN43700<br />

(92 +0,8 x 45 +0,6 )<br />

240g<br />

240g<br />

250g<br />

• multi turn potentiometer <strong>for</strong> fine adjustment<br />

of sensitivity at 110%, shown<br />

through a green LED nearby the potentiometer<br />

(available at front or back side of the<br />

monitor)<br />

0...40°C storage<br />

temperature<br />

range:<br />

potential free relay contact<br />

cover <strong>for</strong><br />

<strong>UV</strong>-Monitor PRO8<br />

-40°C...+70°C<br />

For use in dry environment only!<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Available Monitor Types<br />

09/2006<br />

- 33 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Monitor PRO10.4 with Relay Contacts<br />

and Status Indication by LED and LCD<br />

<strong>for</strong> monitoring and evaluation of relative and absolute uv-intensity (depending on sensor type)<br />

and <strong>for</strong> displaying the specific irradiation, determined from flow rate measurement and reactor vessel volume<br />

Accepted by DVGW and OENORM<br />

monitor type sensor signal suitable sensor types<br />

PRO10.4 diode output or<br />

current output<br />

PRO10.4-U2 diode output or<br />

voltage output<br />

Functions:<br />

• LCD-Display: uv-intensity in % or W/m²<br />

(in case of calibrated sensor); 3 front LED:<br />

operating status<br />

• accepts a wide variety of sensor types:<br />

photo diodes, current sensors (Austrian<br />

ÖNORM or German DVGW), voltage<br />

sensors on request<br />

• adjustment of end value in %:<br />

� coarse adjustment of<br />

sensitivity* in 8 steps,<br />

� fine adjustment in a small range<br />

by special multi turn<br />

potentiometer (if a photodiode is<br />

used),<br />

� display of 110% - value at rear<br />

panel (green LED flashes)<br />

• adjustment of end value in W/m²<br />

SiC-SV01, SiC001(-PG), SiCT001-PG, SiC003(-PG), SiC007-P(-PG), SiC007-I(-PG),<br />

SiC021-I(-PG), SiCDVGW002-LP, SiCDVGW002-MP, SiCONORM002-LP, SiCONORM002-MP<br />

SiC-SV01, SiC001(-PG), SiCT001-PG, SiC003(-PG), SiC007-P(-PG), SiCDVGW001-LP,<br />

SiCDVGW001-MP, SiCONORM001-LP, SiCONORM001-MP, SiC007-U2(-PG), SiC021-U2(-PG)<br />

PRO10.4-SLS diode output side looking sensors: SLS-SiC003(-PG), SLS-SiC004(-PG)<br />

depending on the sensor type* (using<br />

a calibrated sensor with standard<br />

current port: 4-20mA, 0-20 mA; 0-2<br />

V on request)<br />

• two potential free relay contacts indicate<br />

pre alarm and main alarm condition, switching<br />

thresholds can be programmed*<br />

• internal real time clock <strong>for</strong> counting<br />

purposes*<br />

• internal hour counter to determine the<br />

total operation time of the system<br />

• user programmable hour counter e.g. <strong>for</strong><br />

counting operation hours of the lamps<br />

• end of lamp life time display*, after<br />

reaching the programmed value the yellow<br />

LED is blinking<br />

• two display modes to display either uvintensity<br />

value or the user programmable<br />

hour counter, switched by a switch input at<br />

the rear side of the device<br />

• contact <strong>for</strong> fault of lamp alarm; by shorting<br />

this contact externally the red LED is blinking<br />

and the main alarm relay operates<br />

• input to sense operation mode "<strong>UV</strong>-off". If<br />

the unit does not work continuously this<br />

contact stops counting of operation hours<br />

and uv measuring, the last counter reading<br />

remains stored; to prevent alarm during<br />

starting up or switching on again, a delay<br />

time can be programmed*<br />

• internal operating cycle counter*<br />

• RS232 - port <strong>for</strong> service at the rear panel<br />

of the device<br />

*can be programmed by manufacturer and/<br />

or by customer by service device SER10 or<br />

by PC (software MONITOR_ORGANIZER<br />

required)<br />

Technical Specification<br />

mains voltage: 230V AC ± 10% /50/60 Hz operating<br />

0...45°C protection level: IP00<br />

(115V AC/60Hz or 24V DC temperature:<br />

(IP65 at front on<br />

types available on request)<br />

request)<br />

measurement range: adjustable <strong>for</strong> customer purpose in wide range output signal: 4-20mA<br />

status indication: LCD:<br />

3 LED (front):<br />

1 LED (back):<br />

3 digits,<br />

green: function o.k.<br />

adjustment of sensitivity<br />

9mm heigth<br />

yellow: pre-alarm<br />

red: main alarm<br />

green: >110%<br />

relay contact <strong>for</strong> potential free relay contact relay contact load: 50-500mA at 24V-230V AC<br />

alarm:<br />

100-500mA at 24V-60V DC<br />

dimensions (w/h/l): (96/48/134)mm mounting: cut-out according DIN43700 (92 +0,8 x 45 +0,6 )<br />

weight: 300g<br />

Accessories - cover <strong>for</strong> uv monitors <strong>for</strong> protection level IP65 at front<br />

cover <strong>for</strong><br />

<strong>UV</strong>-Monitor PRO10<br />

For use in dry environment only!<br />

<strong>for</strong> side looking sensors please order uv-monitor PRO10.4 SLS<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Service device SER10<br />

Functions:<br />

• automatic change to the service mode,<br />

after the connection of the service device<br />

• display and setting of the internal monitor clock<br />

• display of the total operating hour counter<br />

• display and reset of the user programmable hour counter<br />

• set of lamp operation time<br />

• display and change of the delay time after "<strong>UV</strong>-off"<br />

• display and change of the threshold <strong>for</strong> main alarm<br />

• display and change of the threshold <strong>for</strong> pre alarm<br />

• configuring of sensor input (current input or fotodiode)<br />

• coarse adjustment of input sensitivity<br />

(8 steps) if a fotodiode is used<br />

• adjustment of end value (1...1999W/m²)<br />

if a current or voltage sensor is used<br />

• display and reset of the operating cycle counter<br />

• a 9V block battery is required<br />

Technical Specification SER10<br />

power supply: 9V (battery or accumulator)<br />

operating temperature: 0...45°C<br />

storage temperature<br />

range:<br />

-40°C...+60°C<br />

weight: 200g<br />

accessories: interface cable, instructions<br />

status indication: LCD 3 digits, 9mm heigth<br />

dimensions (w/h/l): (60/125/25)mm<br />

protection level: IP00<br />

09/2006<br />

- 34 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

Service Device and Service Software <strong>for</strong> <strong>UV</strong>-Monitor PRO10<br />

<strong>for</strong> the adjustment of the uv system parameters<br />

SER10 MONITOR_ORGANIZER<br />

For use in dry environment only!<br />

Software MONITOR_ORGANIZER V2.02eng<br />

Functions:<br />

• display of all data from the <strong>UV</strong>-Monitor PRO10<br />

• setting and storage of new configurations at the Monitor PRO10<br />

• adjustment of the alarm value thresholds <strong>for</strong> operation of the<br />

potential free relay contacts<br />

• display and change of the delay time after "<strong>UV</strong>-off"<br />

• display of the operating cycle counter<br />

• setting of lamp operation time<br />

• special function to turn on and off of a pump contact (by<br />

request)<br />

• display of total hour counter<br />

• display and change of user programmable hour counter<br />

• selection of a standard current port<br />

• date/ time adjustment<br />

• selection of sensor input<br />

• special function <strong>for</strong> calculating of specific irradiation based on<br />

intensity, flow rate and reactor vessel volume on request<br />

• configuration can be saved at PC harddisk<br />

• language can be adapted<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Available Monitor Types<br />

Technical Specification<br />

09/2006<br />

- 35 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Monitor PRO11 with Relay Contacts<br />

and Status Indication by backlighted LCD<br />

<strong>for</strong> monitoring and evaluation of relative and absolute uv-intensity (depending on sensor type)<br />

and <strong>for</strong> displaying the specific irradiation, determined from flow rate measurement and reactor vessel volume<br />

monitor type sensor signal suitable sensor types<br />

PRO11PI-I diode output or<br />

current output<br />

PRO11PU3-I diode output or<br />

voltage output<br />

Functions:<br />

• LCD-Display:<br />

� synchronous readout of uvvalue<br />

(1st row of display) and<br />

operating hours (2nd row of<br />

display),<br />

� green (normal), yellow (prealarm)<br />

and red (main alarm)<br />

back lighting,<br />

� uv-intensity<br />

in %, W/m² or mW/cm²<br />

(in case of calibrated sensor)<br />

• accepts a wide variety of sensor types:<br />

photo diodes, current sensors, voltage<br />

sensors on request<br />

• automatic adjustment of end value (using<br />

a photodiode)<br />

• adjustment of end value in W/m² depending<br />

on the sensor type*<br />

mains voltage: 230V AC ± 10% /50/60 Hz<br />

(115V AC/60Hz or 24V DC types<br />

available on request)<br />

SiC-SV01, SiC001(-PG), SiCT001-PG, SiC003(-PG), SiC007-P(-PG), SiC007-I(-PG), SiC021-I(-PG),<br />

SiCDVGW002-LP, SiCDVGW002-MP, SiCONORM002-LP, SiCONORM002-MP<br />

SiC-SV01, SiC001(-PG), SiCT001-PG, SiC003(-PG), SiC007-P(-PG), SiC007-U3(-PG), SiC021-U3(-PG)<br />

operating<br />

temperature:<br />

0...45°C protection level: IP00<br />

(IP65 at front on<br />

request)<br />

measurement range: automatic adjustment output signal: 4...20mA (potential free)<br />

status indication: LCD: 2*12 digits, 14,5mm heigth backlight colour: green: function o.k., yellow: pre alarm, red: main alarm<br />

relay contact <strong>for</strong> alarm: 2 potential free relay contacts relay contact 50-500mA at 24V-230V AC<br />

load:<br />

100-500mA at 24V-60V DC<br />

dimensions (w/h/l): (96/48/114)mm mounting hole: cut-out according DIN43700 (92 +0,8 x 45 +0,6 )<br />

weight: 300g<br />

Accessories - cover <strong>for</strong> uv monitors <strong>for</strong> protection level IP65 at front<br />

cover <strong>for</strong><br />

<strong>UV</strong>-Monitor PRO11<br />

(using a calibrated sensor)<br />

• two potential free relay contacts indicate<br />

pre alarm and main alarm condition, switching<br />

thresholds can be programmed*<br />

• internal real time clock <strong>for</strong> counting<br />

purposes*<br />

• internal hour counter to determine the<br />

total operation time of the system<br />

• user programmable hour counter e.g. <strong>for</strong><br />

counting operation hours of the lamps<br />

• end of lamp life time display*, after<br />

reaching the programmed value display<br />

shows "exchange lamp"<br />

• contact <strong>for</strong> fault of lamp alarm; by shorting<br />

this contact externally the display shows<br />

"lamp error"<br />

• input to sense operation mode "<strong>UV</strong>-off";<br />

if the unit does not work continuously this<br />

contact stops counting of operation hours<br />

and uv measuring, the last counter reading<br />

remains stored; to prevent alarm during<br />

starting up or switching on again, a delay<br />

time can be programmed*<br />

• internal operating cycle counter*<br />

• RS232 - port <strong>for</strong> service at the rear panel<br />

of the device<br />

• optional RS485 - port <strong>for</strong> digital operation<br />

system<br />

• language can be adapted<br />

*can be programmed by manufacturer and/<br />

or by customer<br />

For use in dry environment only!<br />

<strong>for</strong> side looking sensors please order uv-monitor PRO11SLS<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Available Monitor Types<br />

monitor type supply suitable sensor types<br />

PRO15 /230V AC 230V AC ± 10% 50/60Hz 1,8W SiC-SV01, SiC001(-PG), SiCT001-PG,<br />

PRO15 /115V AC<br />

PRO15 / 12V DC<br />

115V AC ± 10% 50/60Hz 1,8W<br />

12V DC ± 10% 50/60Hz 1,8W<br />

SiC003(-PG), SiC007-P(-PG)<br />

on request:<br />

SLS-SiC003(-PG),<br />

PRO15 / 24V DC 24V DC ± 10% 50/60Hz 1,8W SLS-SiC004(-PG)<br />

Monitoring Features<br />

• synchronous readout<br />

of uv-value (1st row of display)<br />

and operating hours (2nd row of display)<br />

• menu operation by buttons<br />

09/2006<br />

- 36 -<br />

uv-value monitoring:<br />

• relative uv-intensity (in %)<br />

• message "<strong>UV</strong>-value low" in case of uvvalue<br />

below switching threshold<br />

• adjustment of sensitivity<br />

(automatic end adjustment)<br />

Technical Specification<br />

mains voltage: see monitor type CE-con<strong>for</strong>m: yes<br />

mains frequency: 45...65Hz ambient<br />

temperature:<br />

0...40°C<br />

display: 2*8 digits, adjustment of contrast by potentiometer<br />

handling: menu-driven handling and programming by 3 push-buttons<br />

language: alternatively English or German (other languages on request)<br />

dimensions (w/h/l): (72,5/44/72,5)mm weight: 170g<br />

relay contact <strong>for</strong> alarm: potential free relay contact load:<br />

50-200mA at 24V-120V AC<br />

50-500mA at 5V- 24V DC<br />

running time<br />

of the clock:<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Monitor PRO15 with Relay Contacts, Status Indication by LCD,<br />

Integrated Hour Counter<br />

approx. 8 years<br />

The monitor is intended <strong>for</strong> monitoring of the relative uv-intensity.<br />

Monitor Pro15 types <strong>for</strong> sidelooking<br />

sensors (SLS) available on request<br />

hour counter:<br />

• internal real time clock<br />

• total operation time<br />

• programmable lamp hour counter<br />

• programmable lamp lifetime<br />

• message "exchange lamp" in case of<br />

reached end of lamp lifetime<br />

pin assignment:<br />

pin 3: normally off contact<br />

pin 4: change-over contact<br />

pin 5: normally on contact<br />

Please consider the safety instructions in the installation and operating manual.<br />

For use in dry environment only!<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Available Monitor Types<br />

09/2006<br />

- 37 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Monitor PRO16 with Relay Contacts, Status Indication by LCD,<br />

Integrated Hour Counter<br />

PRO16P<br />

The monitor is intended <strong>for</strong> monitoring of absolute/relative uv-intensity.<br />

PRO16I<br />

PRO16U3<br />

PRO16I-I<br />

PRO16U3-I<br />

Features<br />

• various input types<br />

• uv intensity<br />

- absolute measurement<br />

by using a calibrated sensor<br />

- relative measurement<br />

by using a photodiode<br />

• automatic sensitivity<br />

adjustment (photodiode)<br />

• 2*12 digit display<br />

(red/green backlight)<br />

• internal clock<br />

• global and user hour counter<br />

• adjustable end of lamp<br />

lifetime alarm<br />

• adjustable uv-low alarm<br />

• fault relay - potential free<br />

relay contact<br />

• menu lock<br />

photodiode input x x x x x<br />

4...20mA current input x x x x<br />

0...3V voltage input x x x x<br />

4...20mA current output x x x x<br />

absolute measurement x x x x x x x x<br />

relative measurement x x x x x x x x x<br />

sensor power supply +12V DC stabilised x x x x x x x x<br />

Dimensions Block schematic<br />

Technical Specification<br />

mains voltage: 230V AC ± 10% 50/60Hz 2W CE-con<strong>for</strong>m: yes<br />

mains frequency: 45...65Hz ambient temperature: 0...40°C<br />

display: 2*12 digits, green or red back lighting <strong>for</strong> status indication,<br />

adjustment of contrast by menu<br />

handling: menu-driven handling and programming by 3 push-buttons<br />

language: alternatively English or German<br />

dimensions (w/h/l): (72,5/44/72,5)mm weight: 200g<br />

relay contact: load: 20-200mA at 24V-120V AC / 20-500mA at 5V- 24V DC<br />

running time of the clock: approx. 8 years<br />

photodiode input<br />

(PRO16Px-x)<br />

4...20mA input<br />

( PRO16xI-x)<br />

0...3V input<br />

( PRO16xU3-x)<br />

4...20mA output<br />

(PRO16xx-I)<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com<br />

PRO16PI<br />

PRO16PU3<br />

central<br />

processing<br />

unit<br />

PRO16PI-I<br />

2*12 display<br />

buttons<br />

real time clock<br />

memory<br />

relay<br />

power supply<br />

Please consider the safety instructions in the installation and operating manual.<br />

For use in dry environment only!<br />

PRO16PU3-I


Technical Specification<br />

09/2006<br />

PRO 20<br />

Functions:<br />

• LCD-Display:<br />

� different (customer specific)<br />

display modes,<br />

� green, yellow and red back<br />

lighting,<br />

� uv-intensity in % or W/m² (in<br />

case of calibrated sensor)<br />

• accepts a wide variety of sensor types:<br />

photo diodes, current sensors (Austrian<br />

OENORM or German DVGW), voltage<br />

sensors on request<br />

• automatic adjustment of end value<br />

• adjustment of end value in W/m²<br />

depending on the sensor type* (using a<br />

calibrated sensor with standard current<br />

port: 4-20mA; 0-20 mA; 0-2 V on request)<br />

mains voltage: 230V AC ± 10% /50/60 Hz<br />

(115V AC/60Hz or 24V DC types<br />

available on request)<br />

sensor ports: 4 diode-output-sensors<br />

(optional:<br />

current or voltage output)<br />

2 additional inputs <strong>for</strong> currentoutput<br />

sensors or flow meter<br />

additional ports: 4 optic isolated gate inputs<br />

3 potential free relay contacts<br />

(change-over contact)<br />

1 potential free output 4...20mA<br />

- 38 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Monitor PRO20 <strong>for</strong> Analog and Digital Multi-Sensoring<br />

<strong>for</strong> monitoring and evaluation of relative and absolute uv-intensity<br />

(depending on sensor type)<br />

and <strong>for</strong> displaying the specific irradiation,<br />

determined from flow rate measurement and reactor vessel volume<br />

PRO 20-S<br />

operating<br />

temperature:<br />

suitable sensor<br />

types:<br />

relay contact load: 50-500mA at 24V-230V AC<br />

100-500mA at 24V-60V DC<br />

measurement range: adjustable <strong>for</strong> customer purpose in wide range<br />

status indication: LCD 4*20 digits<br />

with green, yellow and red<br />

back lighting<br />

<strong>for</strong> status indication<br />

dimensions (w/h/l): with housing (PRO 20):<br />

(143/143/67)mm<br />

• input <strong>for</strong> temperature sensor<br />

• three potential free relay contacts indicate<br />

pre alarm and main alarm condition, switching<br />

thresholds can be programmed<br />

• four optic isolated gate inputs <strong>for</strong> switching<br />

purposes<br />

• internal buzzer (disengageable) <strong>for</strong> status<br />

indication<br />

• internal real time clock <strong>for</strong> counting<br />

purposes<br />

• internal hour counter to determine the<br />

total operation time of the system<br />

• user programmable hour counter e.g. <strong>for</strong><br />

counting operation hours of the lamps<br />

1 RS485 interface <strong>for</strong> digital sensor bus<br />

(digital operation system)<br />

1 measurement input <strong>for</strong> temperature<br />

1 RS232-port <strong>for</strong> service<br />

internal buzzer<br />

(disengageable)<br />

without housing (PRO 20-S):<br />

(134/134/45)mm<br />

• end of lamp life time display, after reaching<br />

the programmed value display shows<br />

"exchange lamp"<br />

• contact <strong>for</strong> fault of lamp alarm; by shorting<br />

this contact externally the display shows<br />

"error lamp"<br />

• calculation of the specific irradiation by<br />

Ee and flow<br />

• language can be adapted<br />

• extensive customer specific menu system<br />

editable (different languages)<br />

0...45°C protection level: IP00<br />

(IP65 at front<br />

on request)<br />

P-SiC003, P-SiC003-PG, P-SiC007, P-SiC021,<br />

P-SLS-SiC003, P-SLS-SiC004<br />

P-SiCDVGW, P-ONORM<br />

with Interface IF03:<br />

SiC-SV01, SiC001, SiC001-PG, SiCT001-PG<br />

weight: 300g mounting: cut-out according DIN43700 (138 +1,0 x 138 +1,0 )<br />

For use in dry environment only!<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


09/2006<br />

- 39 -<br />

Silicon Carbide <strong>UV</strong> Diode SiC-0,1/SiC-0,1-F/SiC-0,25<br />

<strong>for</strong> ZED <strong>UV</strong> sensors<br />

<strong>UV</strong>-Sensor SiC-SV01<br />

with diode output<br />

<strong>UV</strong>-Sensor SiC001/SiC001-PG<br />

with diode output<br />

<strong>UV</strong>-Sensor SiC001T-PG<br />

teflon sensor with diode output<br />

<strong>UV</strong>-Sensor SiC003/SiC003-PG<br />

with diode output<br />

<strong>UV</strong>-Sensor SLS-SiC003/SLS-SiC003-PG<br />

side-looking sensor with amplified diode output<br />

<strong>UV</strong>-Sensor SLS-SiC004/SLS-SiC004-PG<br />

side-looking sensor with amplified diode output<br />

<strong>UV</strong>-Sensor SiC007-x / SiC007-x-PG<br />

with diode, current or voltage output<br />

<strong>UV</strong>-Sensor SiC021-x / SiC021-x-PG<br />

with current or voltage output<br />

<strong>UV</strong>-Sensor SiCDVGWx/SiCONORMx<br />

according to German rule W294 / Austrian rule OENORM<br />

with voltage or current output<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Sensors - Overview<br />

<strong>for</strong> measurement in uv-units<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Technical Specification<br />

diode name spectral<br />

range [nm]<br />

09/2006<br />

SiC-0,1<br />

SiC-0,1-F<br />

(with uvc-filter)<br />

SiC-0,25<br />

uv sensitive<br />

area [mm²]<br />

- 40 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Silicon Carbide <strong>UV</strong> Diodes<br />

<strong>for</strong> ZED <strong>UV</strong> Sensors<br />

exclusively <strong>for</strong> uv measurement, e.g. monitoring of sterilistaion lamps or flame monitoring<br />

body: TO 18 (SiC-0,1, SiC-0,25: diode is electrically isolated from housing)<br />

operation temperature: -25°C...70°C storage temperature: 0°C...100°C<br />

soldering temperature: 260°C (3s max.)<br />

max. uv<br />

sensitivity<br />

on λ max =<br />

275nm<br />

max. uv<br />

sensitivity<br />

on λ max =<br />

254nm<br />

dark current<br />

[fA]<br />

on V R =1V<br />

short-circuit<br />

current [nA]<br />

on bright<br />

sun/cloudy<br />

sky<br />

reverse<br />

voltage [V]<br />

SiC-0,1 210...380 0,0625 0,13 A/W 0,11 A/W 1 50/20 20 21<br />

SiC-0,1-F 210...280 0,0625 1 - 20 21<br />

SiC-0,25 210...380 0,25 1 50/20 20 21<br />

capacity<br />

[pF]<br />

Shielding connection must not be used as earth connection <strong>for</strong> safety reasons.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


SiC001<br />

Available Sensor Types<br />

09/2006<br />

SiC-SV01 SiC003<br />

- 41 -<br />

PG versions without plug connection between sensor and cable.<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Sensors <strong>for</strong> Monitoring of Relative <strong>UV</strong>-Intensities<br />

to be used <strong>for</strong> measurement in <strong>UV</strong>-units<br />

SiC003-PG SiCT001-PG<br />

SiC001-<strong>for</strong> <strong>UV</strong>-Compact SiC001-PG SiC001-PG-BNC<br />

type thread/length wrench diameter length [mm] weight [g] suitable monitor types<br />

<strong>for</strong> mounting size [mm] [mm]<br />

SiC-SV01 - - 17,5 38,5 140 (including 1m cable)<br />

SiC001<br />

SiC001-PG<br />

G 1/4’’ / 14mm<br />

G 1/4’’ / 14mm<br />

19<br />

19<br />

21,7<br />

21,7<br />

49 (with plug: 84) 55 (+115g cable and plug)<br />

61 125 (including 1m cable)<br />

PRO2, PRO3, PRO5,<br />

PRO8, PRO10.4, PRO11<br />

PRO15, PRO16,<br />

SiCT001-PG G 1/4’’ / 14mm 17 20 57 85 (including 1m cable) IF01, IF02, IF03<br />

SiC003 G 3/4’’ / 11mm 32 37 52 (with plug: 87) 195 (+115g cable and plug)<br />

SiC003-PG G 3/4’’ / 11mm 32 37 63 270 (including 1m cable)<br />

SiC001 <strong>for</strong> <strong>UV</strong>-<br />

Compact1<br />

G 1/4’’ / 14mm 19 21,7 49 55 (no additional cable) <strong>UV</strong> Compact MC<br />

SiC001-PG-BNC G 1/4’’ / 14mm 19 21,7 61 180 (including 2m cable) <strong>UV</strong> Compact MCplus<br />

Technical Specification<br />

diode type: silicon carbide (SiC) 0,0625mm²<br />

(SiCT001-PG: 0,25mm²)<br />

spectral range: 210...380nm<br />

(with uvc-filter: 210...280nm)<br />

max. pressure: SiC001(-PG)/SiCT001-PG/SiC003(-PG):10bar<br />

SiC-SV01: diode is sealed with quartz window-protection<br />

against humidity only<br />

body: stainless steel 1.4305<br />

(SiCT001-PG: Teflon)<br />

flare angle: 26°<br />

operating temperature: 0...40°C<br />

connection: 2wire cable, shielded:<br />

SiC001/SiC003: mounting cable with straight connector M12, length 2.90m<br />

(IP65 if inserted and screwed with straight M12 connector)<br />

SiC-SV01, SiC001-PG, SiCT001-PG, SiC003-PG: mounted cable, length 1m (up to 2,90m on request)<br />

SiC001 <strong>for</strong> <strong>UV</strong>-Compact: no additional cable (cable with straight connector M12 already mounted on <strong>UV</strong> Compact MC)<br />

SiC001-PG-BNC: mounted cable with BNC-Plug <strong>for</strong> connection to <strong>UV</strong> Compact MCplus<br />

mounting<br />

restrictions:<br />

cover thread with teflon tape or ceramo paste be<strong>for</strong>e mounting<br />

Sensor SiC003(-PG) is also available as digital sensor <strong>for</strong> digital operation system,<br />

please order D-SiC003(-PG).<br />

SiC-SV01, SiC001(-PG), SiC003(-PG), SiCT001-PG require interface IF03 <strong>for</strong><br />

interconnection with digital operation system.<br />

The sensors are daylight blind (see diagramm) and standard without uvc-filter.<br />

Limitation of spectral sensitivity with uvc-filter is available on request <strong>for</strong> use with<br />

medium pressure lamps. Add “-F“ <strong>for</strong> sensor with uvc filter.<br />

Shielding connection must not be used as earth connection <strong>for</strong> safety reasons.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


type thread/length<br />

<strong>for</strong> mounting<br />

Add “-F“ <strong>for</strong> sensor with uvc filter.<br />

Side-Looking sensors are also available as digital sensors <strong>for</strong> digital operation system.<br />

Please order D-SLS-SiC003(-PG)/D-SLS-SiC004(-PG).<br />

09/2006<br />

extended flare angle<br />

of side looking sensors<br />

Available Sensor Types<br />

- 42 -<br />

wrench<br />

size [mm]<br />

diameter<br />

[mm]<br />

SLS-SiC003 SLS-SiC003-PG<br />

SLS-SiC004 SLS-SiC004-PG<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Sensors with Extended Flare Angle (Side-Looking Sensors)<br />

<strong>for</strong> Monitoring of Relative <strong>UV</strong>-Intensities<br />

length [mm] weight [g] suitable monitor types<br />

SLS-SiC003 G 3/4“ / 11mm 32 37 70 (with plug: 120) 190 (+115g cable and plug)<br />

SLS-SiC003-PG G 3/4“ / 11mm 32 37 81 270 (including cable)<br />

SLS-SiC004 - - 21,5 75 (with plug: 127) 85 (+115g cable and plug)<br />

SLS-SiC004-PG - - 21,5 86 171 (including cable)<br />

Technical Specification<br />

diode type: silicon carbide (SiC) 0,25mm² body: stainless steel 1.4305<br />

spectral range: 210...400nm<br />

(with uvc-filter: 210...280nm)<br />

flare angle: see diagram above<br />

max. pressure: 10bar operating temperature: 0...40°C<br />

to be used <strong>for</strong> measurement in <strong>UV</strong>-units<br />

• daylight blind<br />

(see diagramm below)<br />

• standard without uvc-filter<br />

• limitation of spectral sensitivity<br />

with uvc-filter on<br />

request<br />

• PG versions without<br />

plug connection between<br />

sensor and cable<br />

• integrated amplifier ±5V<br />

(DC supply necessary)<br />

PRO10.4 SLS,<br />

PRO15 SLS<br />

connection: SLS-SiC003 / SLS-SiC004: connector M12, mounting cable with plug included, length: 2.90m<br />

SLS-SiC003-PG / SLS-SiC004-PG: cable length 1m (up to 2,90m on request)<br />

supply voltage: ±5V<br />

mounting restrictions: cover thread with teflon tape or ceramo paste be<strong>for</strong>e mounting<br />

Limitation of spectral sensitivity with uvc-filter available<br />

on request <strong>for</strong> use with medium pressure lamps.<br />

Shielding connection must not be used as earth connection <strong>for</strong> safety reasons.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Technical Specification<br />

09/2006<br />

SiC007-P-PG<br />

• adjusted versions with current or voltage output<br />

• photodiode output versions also available<br />

• PG versions without plug connection<br />

between sensor and cable<br />

Available Sensor Types<br />

- 43 -<br />

SiC007-I-PG<br />

SiC007-Ux-PG<br />

SiC007-P<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Sensor SiC007 <strong>for</strong> MF001 with various output signals<br />

<strong>for</strong> the measuring / monitoring of <strong>UV</strong> irradiation<br />

SiC007-I<br />

SiC007-Ux<br />

• suitable as plug-in sensor in measurement window MF001<br />

• daylight blind (see diagramm below)<br />

• standard without uvc-filter<br />

• limitation of spectral sensitivity with uvc-filter on request<br />

sensor type signal output value adjusted value* min. load<br />

resistance R min<br />

* other values on request. Add “-F“ <strong>for</strong> sensor with uvc filter.<br />

SiC007(-PG) is also available as digital sensor <strong>for</strong> digital operation system. Please order D-SiC007(-PG).<br />

max. load<br />

resistance R max<br />

SiC007-P photodiode output diode current - - -<br />

SiC007-P-PG photodiode output diode current - - -<br />

SiC007-I current output 4 - 20mA 20mA - 9V⇒330Ω / 24V⇒1kΩ<br />

SiC007-I-PG current output 4 - 20mA 20mA - 9V⇒330Ω / 24V⇒1kΩ<br />

SiC007-U2 voltage output 0 - 2V 2V 220Ω -<br />

SiC007-U2-PG voltage output 0 - 2V 2V 220Ω -<br />

SiC007-U3 voltage output 0 - 3V 3V 270Ω -<br />

SiC007-U3-PG voltage output 0 - 3V 3V 270Ω -<br />

SiC007-U10 voltage output 0 - 10V 10V 660Ω -<br />

SiC007-U10-PG voltage output 0 - 10V 10V 660Ω -<br />

diode type: silicon carbide (SiC) 0,0625mm² body: stainless steel 1.4305<br />

spectral range: 210...400nm<br />

(with uvc-filter: 210...280nm)<br />

flare angle: 26°<br />

supply voltage UB :<br />

9… 24V stabilised, I ≤ 25mA linearity within the initial 2%<br />

(current/voltage output) (min. 12V <strong>for</strong> SiC007-U10) voltage range:<br />

temperature drift: 0,03 W/m²/K max. pressure: diode is sealed with quartz windowprotection<br />

against humidity only<br />

operating temperature: 0...40°C<br />

dimensions: body-diameter: 20mm<br />

length:<br />

weight:<br />

outer ring: 27mm<br />

86mm (SiC007)<br />

120g (SiC007)<br />

95mm (SiC007-PG, without cable) 155g (SiC007-PG with 1m cable)<br />

connection: SiC007: connector M12 (Hirschmann cable plug ELST 5012),<br />

mounting cable with plug included, length: 2.90m<br />

SiC007-PG: cable length 1m<br />

(other cable lengths on request)<br />

Limitation of spectral sensitivity with uvc-filter available<br />

on request <strong>for</strong> use with medium pressure lamps.<br />

Mounting Restrictions<br />

Attention! The sensor is not suitable <strong>for</strong> directly use in water! The diode is<br />

sealed with quartz window-protection against humidity only. Please do not<br />

touch the surface of the sensor window.<br />

We recommend the use of a sealing ring (O-ring, 20x1,5) in the outer ring.<br />

Shielding connection must not be used as earth connection <strong>for</strong> safety reasons.<br />

Do not connect or disconnect sensor-plug while supply voltage is switched on.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


09/2006<br />

SiC021-x-PG<br />

Available Sensor Types<br />

Technical Specification<br />

- 44 -<br />

SiC021-x<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Sensor SiC021 with various output signals<br />

sensor type signal output value adjusted value* min. load<br />

resistance R min<br />

<strong>for</strong> the measuring / monitoring of <strong>UV</strong> irradiation<br />

* other values on request<br />

Add “-F“ <strong>for</strong> sensor with uvc filter.<br />

SiC021-PG is also available as digital sensor <strong>for</strong> digital operation system. Please order D-SiC021(-PG).<br />

• adjusted versions with<br />

current or voltage output<br />

• daylight blind<br />

(see diagramm below)<br />

• standard without uvc-filter<br />

• limitation of spectral sensitivity<br />

with uvc-filter on request<br />

• PG versions without plug<br />

connection between sensor<br />

and cable<br />

max. load<br />

resistance R max<br />

SiC021-I current output 4 - 20mA 20mA - 9V⇒330Ω / 24V⇒1kΩ<br />

SiC021-I-PG current output 4 - 20mA 20mA - 9V⇒330Ω / 24V⇒1kΩ<br />

SiC021-U2 voltage output 0 - 2V 2V 220Ω -<br />

SiC021-U2-PG voltage output 0 - 2V 2V 220Ω -<br />

SiC021-U3 voltage output 0 - 3V 3V 270Ω -<br />

SiC021-U3-PG voltage output 0 - 3V 3V 270Ω -<br />

SiC021-U10 voltage output 0 - 10V 10V 660Ω -<br />

SiC021-U10-PG voltage output 0 - 10V 10V 660Ω -<br />

diode type: silicon carbide (SiC) 0,0625mm² body: stainless steel 1.4305<br />

spectral range: 210...400nm<br />

(with uvc-filter: 210...280nm)<br />

flare angle: 26°<br />

supply voltage UB : 9… 24V stabilised, I ≤ 25mA linearity within the initial 2%<br />

(min. 12V <strong>for</strong> SiC021-U10) voltage range:<br />

temperature drift: 0,03 W/m²/K max. pressure: 10bar<br />

operating temperature: 0...40°C<br />

dimensions: thread: G1/4’’<br />

length:<br />

weight:<br />

wrench size:19<br />

67mm (SiC021)<br />

77g (SiC021)<br />

body-diameter: 22mm<br />

78mm (SiC021-PG without cable) 105g (SiC021-PG with 1m cable)<br />

connection: SiC021: connector M12 (Hirschmann cable plug ELST 5012),<br />

mounting cable with plug included, length: 2.90m<br />

SiC021-PG: cable length 1m<br />

(other cable lengths on request)<br />

mounting restrictions: cover thread with teflon tape or ceramo paste be<strong>for</strong>e mounting<br />

Limitation of spectral sensitivity with uvc-filter available<br />

on request <strong>for</strong> use with medium pressure lamps.<br />

Shielding connection must not be used as earth connection <strong>for</strong> safety reasons.<br />

Do not connect or disconnect sensor-plug while supply voltage is switched on.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


SiCDVGW SiCONORM<br />

Available Sensor Types<br />

* output value 0...10V on request<br />

09/2006<br />

- 45 -<br />

• suitable as plug-in sensor<br />

in measurement window<br />

MF001<br />

• several supply voltages<br />

available<br />

• several output signals<br />

available<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Sensors adapted to Special Regulations, Calibrated<br />

according to German rule W294, resp. Austrian rule OENORM<br />

sensor type signal output value* suitable monitor types lamp types<br />

SiCDVGW001-LP voltage output 0...2V<br />

low pressure lamps<br />

SiCDVGW001-MP<br />

SiCONORM001-LP<br />

voltage output<br />

voltage output<br />

0...2V<br />

0...2V<br />

PRO10.4 (0-2V)<br />

medium pressure lamps<br />

low pressure lamps<br />

SiCONORM001-MP voltage output 0...2V medium pressure lamps<br />

SiCDVGW002-LP current output 4...20mA PRO10.4,<br />

low pressure lamps<br />

SiCDVGW002-MP<br />

SiCONORM002-LP<br />

current output<br />

current output<br />

4...20mA<br />

4...20mA<br />

PRO11PI-I,<br />

PRO16I (-I)<br />

PRO16PI (-I)<br />

medium pressure lamps<br />

low pressure lamps<br />

SiCONORM002-MP current output 4...20mA medium pressure lamps<br />

Technical Specification<br />

uv-sensor: silicon carbide-(SiC) diode<br />

0,25*0,25mm²<br />

dimensions: diameter of the body: 20mm<br />

diameter of the outer ring: 27mm<br />

length: 91mm<br />

insert length: 59mm<br />

body: stainless steel 1.4307<br />

weight: 83g (without cable)<br />

supply voltage UB: 9… 15V stabilised linearity within the<br />

initial voltage range:<br />

2%<br />

operation current: SiCxxx001:


Spectral Sensitivity <strong>for</strong> <strong>Low</strong> and Medium <strong>Pressure</strong> Lamps<br />

relative sensitivity [%]<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

190<br />

Measurement window MF001 <strong>for</strong> DVGW-sensors and ONORM-sensors<br />

The uv-measurement window according to rule W294,<br />

suitable <strong>for</strong> input of DVGW Sensor SICDVGW***,<br />

the uv-measurement window according to rule OENORM,<br />

suitable <strong>for</strong> input of ONORM Sensor SICONORM***,<br />

watertight up to 10bar,<br />

consists of:<br />

• stainless steel (1.4305) body:<br />

length: 65mm / wrench size: 32 / thread: G1’’, 20mm long<br />

weight: 365g<br />

• hole <strong>for</strong> sensor input<br />

∅20 x 60mm with cap nut M30 x 2 to connect the sensor<br />

• window made from quartz glass<br />

∅24,5 x 5mm<br />

09/2006<br />

low pressure lamps: spectral sensitivity<br />

Characteristics<br />

240<br />

290<br />

wavelength [nm]<br />

340<br />

390<br />

- 46 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Sensors adapted to Special Regulations, Calibrated<br />

relative sensitivity [%]<br />

according to German rule W294, resp. Austrian rule OENORM<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

200<br />

medium pressure lamps: spectral sensitivity<br />

actual value of the sensor<br />

desired value according to DVGW<br />

220 240 260 280 300 320 340<br />

wavelength [nm]<br />

MF001<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


Functions:<br />

1. amplification of the signal output of fotodiode current sensors to voltage<br />

output 0...5V (IF01) resp. current output 4...20mA (IF02)<br />

2. adjustment of the sensor output signal according to the requirements<br />

of the PLC (IF01, IF02) or of the digital operation system (IF03)<br />

3. 2 input/output channels<br />

4. fine adjustment of amplification by multi turn potentiometer<br />

Available Interface Types<br />

type output<br />

IF01 2x 0...5V<br />

(2x 0...2V on request)<br />

IF02 2x 4...20mA<br />

IF03 digital sensor signal<br />

Technical Specification<br />

mains voltage: 230V AC ± 10%, 50Hz<br />

max. 2,5W<br />

115V-types available on request<br />

input: up to 2 fotodiodes<br />

(adjustment necessary)<br />

09/2006<br />

- 47 -<br />

protection level: IP00<br />

weight: 200g<br />

dimensions (w/h/l): (97/48/43)mm mounting: DIN rail<br />

Examples <strong>for</strong> wiring<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

Interfaces IF01, IF02, IF03<br />

<strong>for</strong> the Connection of Sensors and PLC<br />

For use in dry environment only!<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


SW 5<br />

Available Lamp Control Types<br />

type switching<br />

threshold<br />

09/2006<br />

- 48 -<br />

operation<br />

current range<br />

switch on<br />

delay time<br />

SW 10<br />

switch off<br />

delay time<br />

SW 5.60 60 mA 60 - 200 mA ca. 0,5s ca. 0,5s<br />

SW 5.200 200 mA 200 - 800 mA ca. 0,5s ca. 0,5s<br />

SW 5.800 800 mA 800 - 1000 mA ca. 0,5s ca. 0,5s<br />

SW 10.60 60 mA 60 - 200 mA ca. 6s ca. 2s<br />

SW 10.200 200 mA 200 - 800 mA ca. 6s ca. 2s<br />

SW 10.800 800 mA 800 - 1500 mA ca. 6s ca. 2s<br />

SW 10.1500 1500 mA 1500 - 2500 mA ca. 6s ca. 2s<br />

SW 10.2500 2500 mA 2500 - 4000 mA ca. 6s ca. 2s<br />

Technical Specification<br />

mains voltage: 230V AC ± 10%<br />

mains frequency: 45...65Hz<br />

using with<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

Control Units SW5 and SW10 <strong>for</strong> Lamp Function Control<br />

status indication: SW5:<br />

two potential free relay contacts (closed at correct operation),<br />

load: 50 - 500mA at 24V - 230V AC; 100 - 500mA at 24V - 60V DC<br />

SW10:<br />

green and red LED indicate operating status,<br />

two potential free change over contacts,<br />

load: 50 - 500mA at 24V - 230V AC; 100 - 500mA at 24V - 60V DC<br />

weight: SW5: 70g<br />

SW10: 200g<br />

wire gauge: 0,75...1,5mm²<br />

mounting: DIN rail (DIN EN 50 022-35)<br />

electronic ballasts, monitoring fan,<br />

other control functions<br />

dimensions: (w/h/l) SW5: (97/27/43)mm<br />

SW10: (97/48/43)mm<br />

starter and choke,<br />

other conventional circuit,<br />

electronic ballasts, other control functions<br />

Control units <strong>for</strong> other applications are also available.<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


09/2006<br />

- 49 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

Measurement Technique<br />

<strong>UV</strong>-Radiation Meter <strong>UV</strong>M-CP<br />

<strong>for</strong> measurement of radiation intensity<br />

The <strong>UV</strong> radiation meter is available <strong>for</strong> <strong>UV</strong>-A, <strong>UV</strong>-B, <strong>UV</strong>-C and <strong>UV</strong>/vis.<br />

The gauge is equipped as standard with a cos-correction, which permits<br />

exact measurement at short distance.<br />

The housing of the hand unit is made of polystyrene, the housing of the<br />

probe of aluminium.<br />

Technical Specification<br />

power supply: 9V (battery or accumulator) operating temperature: 15...40°C<br />

status indication: LCD 3 digits, 9mm heigth protection level: IP00<br />

measurement range: 2/20/200/2.000 mW/cm² measurement resolution: 1/10/100/1.000 µW/cm²<br />

spectral range: <strong>UV</strong>-A: 310...420nm<br />

<strong>UV</strong>-B: 250...370nm<br />

<strong>UV</strong>-C: 200...300nm<br />

<strong>UV</strong>/vis: 370...440nm<br />

reproduction: 3/30/300/3.000 µW/cm²<br />

dimensions (w/h/l): (80/150/28)mm weight: 250g<br />

For use in dry environment only!<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


09/2006<br />

- 50 -<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>UV</strong>-Lamps and Accessories<br />

Quartz Tubes<br />

Immersion Tube Lamps<br />

Our product range includes low pressure lamps and<br />

amalgam lamps of leading manufacturers.<br />

Beside standard and special uv lamps we offer accessories<br />

like quartz tubes in different lengths and diameters and<br />

also special lamp sockets.<br />

Furthermore we offer the production of uv immersion<br />

lamps <strong>for</strong> water disinfection and other applications.<br />

quartz tubes<br />

uv immersion tube lamps<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com


09/2006<br />

- 51 -<br />

Lamp Socket: 4pin plastic type<br />

article code F4P<br />

dimensions (l/w/h) (16/13/26,4)mm<br />

wire gauge 0,5...0,8mm²<br />

max. ambient temperature 60°C<br />

max. current 1A<br />

max. voltage 600V<br />

ZED - ZIEGLER ELECTRONIC DEVICES GMBH<br />

<strong>UV</strong>-Lamps and Accessories<br />

Lamp Sockets <strong>for</strong> <strong>Low</strong> <strong>Pressure</strong> Lamps<br />

Ceramic Lamp Sockets especially <strong>for</strong> Amalgam Lamps<br />

The socket is allowed up to 100W/1A.Wire must be solid or top coated stranded<br />

copper wire. Solder dipped is not recommended. Strip length: 1,1...1,25cm.<br />

Wire leads to be fully inserted into wiring port, ensuring uninsulated end of wire is<br />

not exposed. Use wire end ferrules with a length of 12mm.<br />

We recommend crimping pliers with square crimping e.g. KNIPEX KN975304.<br />

Lamp Socket: 2pin plastic type<br />

article code F2P<br />

dimensions (diam./h) (18/13)mm<br />

max. ambient temperature 100°C<br />

max. current 1,5A<br />

max. voltage 600V<br />

Connection by supplied mounting cable.<br />

Lamp Socket: 4pin ceramic type<br />

article code KF4P<br />

dimensions (l/w/h) (17,5/14/23,3)mm<br />

wire gauge 0,5...2mm²<br />

max. ambient temperature 150°C<br />

max. current 6A<br />

max. voltage 600V<br />

Wire must be crimped with included crimp contact, strip length: 3,5mm. We recommend<br />

AMP PRO-CRIMPER II Hand Tool Assembly 90871-1 with Die Assembly<br />

90871-2 <strong>for</strong> crimping contacts.<br />

Lamp Socket: 2G11 ceramic type<br />

article code KF2G11<br />

dimensions (l/w/h) (43/33/23)mm (without spring)<br />

wire gauge 0,5...2mm²<br />

max. ambient temperature 150°C<br />

max. current 6A<br />

max. voltage 600V<br />

Wire must be crimped with included crimp contact, strip length: 3,5mm. We recommend<br />

AMP PRO-CRIMPER II Hand Tool Assembly 90871-1 with Die Assembly<br />

90871-2 <strong>for</strong> crimping contacts.<br />

Crimp Contacts <strong>for</strong> Lamp Sockets<br />

article code single pins <strong>for</strong> KF4P or KF2G11<br />

dimensions inner diameter: 2,26mm, length: 19,8mm<br />

wire gauge 0,5...2mm²<br />

max. ambient temperature 150°C<br />

max. current 6A<br />

max. voltage 600V<br />

strip length: 3,5mm<br />

We recommend AMP PRO-CRIMPER II Hand Tool Assembly 90871-1 with Die<br />

Assembly 90871-2 <strong>for</strong> crimping contacts.<br />

Do not use the sockets in chemical aggressive and/or humid environment!<br />

ZED - Ziegler <strong>Electronic</strong> Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/Germany<br />

Phone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: info@z-e-d.com