12.07.2015 Views

PAS 5308 Part 1/Type 2 Hypron® IOS Fire retardant - Nexans

PAS 5308 Part 1/Type 2 Hypron® IOS Fire retardant - Nexans

PAS 5308 Part 1/Type 2 Hypron® IOS Fire retardant - Nexans

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ContactProduits Mehunfabienne.damilo@nexans.com<strong>PAS</strong> <strong>5308</strong> <strong>Part</strong> 1/<strong>Type</strong> 2 Hypron® <strong>IOS</strong> <strong>Fire</strong> <strong>retardant</strong>- Instrumentation cables 300/500 V- XLPE insulation (<strong>Part</strong> 1)- Armoured (<strong>Type</strong> 2)- Individual & Overall Screen (<strong>IOS</strong>)- Lead free- Aliphatic and aromatic hydrocarbons resistantDescriptionApplicationsThese instrumentation and communication cable are used to transmit analogueor digital signals in measurement and process control in moist areas andwhere aliphatic and aromatic hydrocarbons may be present. They are welladapted to underground use in industrial applications where chemical andmechanical protections are needed (refinery areas, chemical plant...). Theindividual screening of each pair limits the consequence of crosstalk.Hypron® offers an alternative to conventional lead sheathed cable and is anenvironmental friendly solution.DesignConductor:Solid, stranded or flexible bare copperInsulation:Cross-linked polyethylene (XLPE)Individual screen:Binder tapeTinned copper drain wireAluminium/polyester tapeBinder tapeBinder tape:Bedding:Inner sheath:Polyvinyl chloride (PVC)Colour: black.Overall screen/sealing barrier:Tinned copper drain wireAluminium/polyethylene tapeBedding:High density polyethylene (PE)StandardsInternational IEC 60332-3-22 Cat.ALead freeYesRated VoltageUo/U (Um)300 / 500 VMechanicalresistance toimpactsGood<strong>Fire</strong><strong>retardant</strong>IEC60332-3-22Chemical resistanceAliphatic andaromatichydrocarbonsresistantElectro magneticinterferenceresistanceYesOperatingtemp. range-20 .. 60 °CMax.conductortemp.in service90 °CVersion fd3 Generated 3/9/14 - http://www.nexans.fr Page 1 / 4All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of<strong>Nexans</strong> is indicative only and shall not be binding on <strong>Nexans</strong> or be treated as constituting a representation on the part of <strong>Nexans</strong>.


ContactProduits Mehunfabienne.damilo@nexans.comColour: blackSpecial sheath (intermediate sheath):PolyamideArmour:Galvanized steel wires (SWA)Outer sheath:Polyvinyl chloride (PVC)Colour: blackOther colour on request.<strong>PAS</strong> <strong>5308</strong> <strong>Part</strong> 1/<strong>Type</strong> 2 Hypron® <strong>IOS</strong> <strong>Fire</strong> <strong>retardant</strong>Core identificationPair: black - whiteWhite core printed with pair numberOn request: according to <strong>PAS</strong> <strong>5308</strong> part 1MarkingNEXANS 279 XLPE/IND.SCR/AL/HDPE/NC/SWA/PVC 300/500V Nber of pairs &cross-section Cu IEC 60332-3-22(A) MM YYYY Manufacturing number + metricmarkingStandards<strong>PAS</strong> <strong>5308</strong> <strong>Part</strong> 1/type 2 (Design guide-lines)BS EN 60228-2005BS EN 50290-2-29CharacteristicsConstruction characteristicsConductor materialInsulationIndividual screenInner sheathOverall screenMaterial of beddingIntermediate sheathBare copperXLPE (Cross-linked Polyethylene)Tinned copper drain wire + aluminium/polyestertapePVCTinned copper drain wire + aluminium/polyethylenetapeHigh-density polyethylene (PE)PolyamideLead freeYesRated VoltageUo/U (Um)300 / 500 VMechanicalresistance toimpactsGood<strong>Fire</strong><strong>retardant</strong>IEC60332-3-22Chemical resistanceAliphatic andaromatichydrocarbonsresistantElectro magneticinterferenceresistanceYesOperatingtemp. range-20 .. 60 °CMax.conductortemp.in service90 °CVersion fd3 Generated 3/9/14 - http://www.nexans.fr Page 2 / 4All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of<strong>Nexans</strong> is indicative only and shall not be binding on <strong>Nexans</strong> or be treated as constituting a representation on the part of <strong>Nexans</strong>.


ContactProduits Mehunfabienne.damilo@nexans.com<strong>PAS</strong> <strong>5308</strong> <strong>Part</strong> 1/<strong>Type</strong> 2 Hypron® <strong>IOS</strong> <strong>Fire</strong> <strong>retardant</strong>Construction characteristicsArmour typeGalvanized steel wiresOuter sheathPVCLead freeYesProtectionYesElectrical characteristicsRated Voltage Uo/U (Um)300 / 500 VMechanical characteristicsMechanical resistance to impactsGoodUsage characteristics<strong>Fire</strong> <strong>retardant</strong> IEC 60332-3-22Chemical resistanceAliphatic and aromatic hydrocarbons resistantElectro magnetic interference resistanceYesOperating temperature, range -20 .. 60 °CMax. conductor temperature in service 90 °CStandard<strong>PAS</strong>Class 1 0.5<strong>Nexans</strong>ref.nbpairsConductordiam.[mm]Diam. overinsulation[mm]Diam. overinnersheath[mm]Diam.intermediatesheath[mm]Diam.overarmour[mm]Min.outerdiam.[mm]Max.outerdiam.[mm]Approx.weight[kg/km]2 0.8 1.8 9.5 12.9 14.7 20.1 22.1 6015 0.8 1.8 12.2 15.6 18.1 23.4 25.8 89110 0.8 1.8 16 19.6 22.1 27.3 30.1 119320 0.8 1.8 20.9 24.7 27.9 32.9 36.3 182430 0.8 1.8 25 28.8 32.0 36.9 40.7 2293Class 5 0.5<strong>Nexans</strong>ref.nbpairsConductordiam.[mm]Diam. overinsulation[mm]Diam. overinnersheath[mm]Diam.intermediatesheath[mm]Diam.overarmour[mm]Min.outerdiam.[mm]Max.outerdiam.[mm]Approx.weight[kg/km]2 0.9 2.1 10.6 14 15.8 21.1 23.3 6515 0.9 2.1 13.7 17.1 19.6 24.8 27.4 97210 0.9 2.1 18.1 21.7 24.9 30.0 33.1 147820 0.9 2.1 23.7 27.5 30.7 35.6 39.3 201130 0.9 2.1 28.5 32.3 36.3 41.0 45.3 2801Lead freeYesRated VoltageUo/U (Um)300 / 500 VMechanicalresistance toimpactsGood<strong>Fire</strong><strong>retardant</strong>IEC60332-3-22Chemical resistanceAliphatic andaromatichydrocarbonsresistantElectro magneticinterferenceresistanceYesOperatingtemp. range-20 .. 60 °CMax.conductortemp.in service90 °CVersion fd3 Generated 3/9/14 - http://www.nexans.fr Page 3 / 4All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of<strong>Nexans</strong> is indicative only and shall not be binding on <strong>Nexans</strong> or be treated as constituting a representation on the part of <strong>Nexans</strong>.


ContactProduits Mehunfabienne.damilo@nexans.com<strong>PAS</strong> <strong>5308</strong> <strong>Part</strong> 1/<strong>Type</strong> 2 Hypron® <strong>IOS</strong> <strong>Fire</strong> <strong>retardant</strong>Class 2 0.75<strong>Nexans</strong>ref.nbpairsConductordiam.[mm]Diam.overinsulation[mm]Diam. overinnersheath[mm]Diam.intermediatesheath[mm]Diam.overarmour[mm]Min.outerdiam.[mm]Max.outerdiam.[mm]Approx.weight[kg/km]10167991 2 1.1 2.3 11.4 14.8 16.6 21.9 24.2 70010167992 5 1.1 2.3 15 18.4 20.9 26.1 28.8 1074Selling informationOther fire performances IEC 60332-1 or IEC 60332-3-24(C) on request.Minimum bending radius:15 x outer diameterTo be doubled during laying operationsTinned copper conductors available on requestLead freeYesRated VoltageUo/U (Um)300 / 500 VMechanicalresistance toimpactsGood<strong>Fire</strong><strong>retardant</strong>IEC60332-3-22Chemical resistanceAliphatic andaromatichydrocarbonsresistantElectro magneticinterferenceresistanceYesOperatingtemp. range-20 .. 60 °CMax.conductortemp.in service90 °CVersion fd3 Generated 3/9/14 - http://www.nexans.fr Page 4 / 4All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of<strong>Nexans</strong> is indicative only and shall not be binding on <strong>Nexans</strong> or be treated as constituting a representation on the part of <strong>Nexans</strong>.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!