<strong>Humidity</strong> - CalibrationModules <strong>for</strong> measuring relative air humidityOur humidity data loggers are supplied with a precisely calibrated humidity sensor. It is recommended thathumidity sensors used in normal environments are checked every 6 - 12 months <strong>and</strong> recalibrated ifnecessary. In particularly contaminating environments, it may be necessary to clean the sensor verycarefully using water or a max. 40% alcohol solution.Method of humidity verification:Using our SCS calibrated calibration solutions <strong>for</strong>the operating points with relative humidity valuesof 0%, 10 %, 20%, 35%. 50%, 65%, 80% <strong>and</strong>90%.Verification is more important than calibration!Making use of the calibration solutions, it ispossible to simulate a variety of humidity levels atthe sensors. The module should then beevaluated <strong>and</strong> the results checked. There is noreal point in carrying out recalibration unless adeviation of more than ±2% is determined.RecalibrationThe PC software provides support <strong>for</strong> automaticrecalibration of the modules. The followingequipment <strong>and</strong> materials are required:- a calibration unit- calibration solutions <strong>for</strong> 0% .. 95%- a calibration box or thermally insulated box- evaluation software elproLOG WIN- a PC interface (only <strong>for</strong> Hamster <strong>and</strong><strong>HOTDOG</strong>)Recalibration of the modules is carried out byselecting “Extended Setup” from the programmenu. For most applications, calibration with the80% solution will be suitable. After the procedureis started, an automatic program runs in themodule <strong>for</strong> a period of 3 hours, after whichcalibration is complete. The logger status shows,if the calibration has been successful or not.sensor part of the module. The sealing ring can thenbe pulled on.The actual calibration process begins automaticallyafter 2.5 hours. It is necessary to keep the ambienttemperature constant during calibration. The module,with calibration unit fitted, must there<strong>for</strong>e be kept inan insulated box <strong>for</strong> a period of at least 3 hours afterthe start of the process. It can be evaluated at theend of this time. The module’s temperature <strong>and</strong> timeranges can, if necessary, be reprogrammed be<strong>for</strong>e itis put back into use.Clean well <strong>and</strong> dry in acurrent of airSelect a short timeinterval.Start “calibration”only if you wish torecalibrate.Empty calibration solution overfabric discClose the unit, push onto sensor<strong>and</strong> pull on sealing ringLeave in insulated containerthen evaluateIMPORTANT:The calibration unit must be absolutely clean <strong>and</strong>dry be<strong>for</strong>e it is used. The unit should, there<strong>for</strong>e,be disassembled, washed <strong>and</strong> then driedthoroughly in a current of air. The fabric discsupplied (except <strong>for</strong> 0%) is then inserted in thebaseplate of the unit. The ampoule containing thecalibration solution is broken open <strong>and</strong> the liquidpoured over the fabric disc. The unit, with thebaseplate underneath, is then pushed onto theIMPORTANT:<strong>Humidity</strong> probe <strong>and</strong> module are <strong>for</strong>ming a pair.Calibration values must be entered be<strong>for</strong>e the first use.D-DZ-6001E9.1999

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!