THORNTON Conductivity/Resistivity SensorsAccurate and ReliableConductivity/ResistivityConductivity Sensors for M300 & 770MAXA Comprehensive Series to Meet Industry Requirements243E233240-201244-630240-202iSensor Selection CriteriaTHORNTON offers a widevariety of <strong>conductivity</strong>/resistivity<strong>sensors</strong> to accomodate mostapplications. Use the following criteriato select the appropriate sensor for yourinstallation:– Conductivity or resistivity range– Transmitter– Mounting type: insertion, retractableor submersion– Pipe connection and size– Chemical compatibility, includingcleaning and disinfection processes– Temperature requirements, includingsteam and/or hot chemical cleaningTHORNTON provides a full complement of <strong>conductivity</strong>/resistivity <strong>sensors</strong> for M300or 770MAX with NPT or sanitary fittings. They include various lengths, cell constantsand materials to match the application: titanium concentric electrodes forhigh purity water; monel electrodes for rinse waters containing HF; highly polished316L stainless steel (SS) electrodes for pharmaceutical waters; CPVC and PEEK<strong>sensors</strong> with four flush electrodes for solutions with higher <strong>conductivity</strong> and/orsuspended material; and an epoxy sensor which can also measure chemical concentration.SpecificationsCell constant accuracy ± 1%, except ± 5% system accuracy for 4-electrode& 10 constantCell constant repeatability ± 0.25%, except ± 2% for 4-electrode & 10 constantTemperature sensor Pt1000 RTD, IEC 746, Class A, except 50 constantTemperature accuracy ± 0.1°C (± 0.2°F), except 4-electrode <strong>sensors</strong>at 25°C (77°F)Cable jacket materialNPT: PVC, 80°C (176 °F) ratingSanitary: Teflon ® , 200°C (392°F) ratingM300. sensor 60 m (200 ft), except 15 m (50 ft) for 244-Seriesdistance770MAX. sensor 91m (300 ft), except 15m (50 ft) for 234 seriesdistanceFinishN4 (Ra
Microelectr.PowerPharma WaterCalibration of Conductivity SensorsTHORNTON Auto-loop Factory Calibration SystemTHORNTON <strong>conductivity</strong> <strong>sensors</strong> are industry standards for determining waterpurity and solution concentration. THORNTON ISO 9001 factory calibration andcertification are NIST and ASTM traceable using THORNTON’s unique ultrapureauto-loop calibration system. Certification includes test and accuracy, plus materialsas noted in sensor specifications.USP pharmaceutical water monitoring requirements are met with sanitary <strong>sensors</strong>which provide accurate <strong>conductivity</strong> and temperature measurement. 316L stainlesssteel Tri-Clamp mounting <strong>sensors</strong> have an electropolished finish with roughnessaverage (Ra)
THORNTON Conductivity/Resistivity SensorsAccurate and ReliableConductivity/ResistivityConductivity Sensors for M300DrawingsNPT 0.01 and 0.1 Constant3 ⁄ 4 " NPTSanitary, Standard25.4 mm1.00"Sanitary, VP42 mm1.65"X < 3"1 ⁄ 2 " or 3 ⁄ 4 " NPT42 mm1.65"X > 3" 25.4 mm 1.00"64.5 mm2.54"VP connector"X"316SS Flow Housing (1000-30) 12.7 mm 0.50" 15.7 mm 0.62"Sanitary fitting, see table6.35 mm/0.25""X" see table1 ⁄ 8 " NPT outflow port 15.7 mm 0.62" 15.9 mm 0.625"Tri-Clamp fitting, see table10 Constant3 ⁄ 4 " NPTSubmersion 0.1 Constant1" NPT 33.4 mm 1.32"41 mm1.62"NPT 4-Electrode, CVPC151.4 mm/5.96"VP connectorNPT 4-Electrode, PEEK86.6 mm3.41"12.7 mm0.50"3 ⁄ 4 " NPT111.5 mm4.39"82.3 mm/3.24"1" NPT29 mm1.15"27.9 mm1.10"126.7 mm/4.99"57.4 mm 27.9 mm2.26" 1.10" 19.1 mm/0.75" 12.7 mm 0.50" 25.4 mm/1.00"1" NPT26.9 mm/1.06" wrench flats 25.4 mm/1.00" 31.8 mm 1.25"82.6 mm3.25"3 ⁄ 4 " NPT sensor portPVDF Flow Housing (1000-31)1 ⁄ 4 " NPT outflow port25.4 mm/1.00"1 ⁄ 8 " NPT inflow portVP connectorSanitary 4-Electrode105.2 mm/4.14"38.1 mm1.50"26.9 mm/1.06" wrench flats"X"1" NPT 25.4 mm/ 1.00" 38.1 mm 1.50"82.6 mm3.25"3 ⁄ 4 " NPT sensor port28.6 mm/1.13"1 ⁄ 4 " NPT inflow portVP connectorTri-Clamp fitting, see tablewww.mt.com/THORNTON-Cond22METTLER TOLEDO US and Canada
Microelectr.PowerPharma WaterOrdering InformationElectrode Maximum Pressure Process Connection Insertion CableMaterial – Fitting – Material Length "x" Length Connector Order Number2-Electrode Sensors– Measuring range 0.02–2,000 µS/cm (cell constant 0.1 cm –1 ) aTitanium 17 bar at 93°C (250 psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 34 mm (1.35") 0.5 m (1.5 ft) S 240-201Titanium 17 bar at 93°C (250 psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 132 mm (5.19") 0.5 m (1.5 ft) S 240-202Monel 17 bar at 93°C (250 psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 34 mm (1.35") 0.5 m (1.5 ft) S 240-203Monel 17 bar at 93°C (250 psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 132 mm (5.19") 0.5 m (1.5 ft) S 240-204Titanium 7 bar at 95°C (100 psig at 203°F) 3 ⁄4" NPTM PVDF 29 mm (1.15") – S 240-20734 bar at 25°C (500 psig at 77°F)316L SS 4 bar at 131°C (58 psig at 268°F) For SS 70 mm (2.75") – VP 240-2227 bar at 95°C (100 psig at 203°F) Retractable17 bar at 25°C (250 psig at 77°F) housing bTitanium 17 bar at 93°C (250 psig at 200°F) 1 ⁄2" NPTM Noryl 29 mm (1.14") 0.5 m (1.5 ft) S 240-213Titanium 17 bar at 93°C (250 psig at 200°F) 3 ⁄4" NPTM Noryl 29 mm (1.14") 0.5 m (1.5 ft) S 240-214Titanium 17 bar at 93°C (250 psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 34 mm (1.35") 3 m (10 ft) S 240-215Titanium 17 bar at 93°C (250 psig at 200°F) 1 ⁄2" NPTM Teflon ® /SS 29 mm (1.14") 0.5 m (1.5 ft) S 240-216Titanium 17 bar at 93°C (250 psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 34 mm (1.35") 6.1 m (20 ft) c 240-217Titanium 17 bar at 93°C (250 psig at 200°F) 1 ⁄2" NPTM Teflon ® /SS 29 mm (1.14") 3 m (10 ft) c 240-218Titanium 17 bar at 93°C (250 psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 34 mm (1.35") 9 m (30 ft) c 240-220Titanium 10 bar at 155°C (150 psig at 311°F) 1.5" Tri-Clamp Titanium 86 mm (3.38") 0.5 m (1.5 ft) S 243E221 d31 bar at 25°C (450 psig at 77°F)316L SS 10 bar at 155°C (150 psig at 311°F) 1.5" Tri-Clamp 316L SS 86 mm (3.38") 0.5 m (1.5 ft) S 243E223 d31 bar at 25°C (450 psig at 77°F)316L SS 10 bar at 155°C (150 psig at 311°F) 2" Tri-Clamp 316L SS 105 mm (4.13") 0.5 m (1.5 ft) S 243E227 d31 bar at 25°C (450 psig at 77°F)Titanium 17 bar at 93°C (250 psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 34 mm (1.35") 0.5 m (1.5 ft) VP 240-231Titanium 17 bar at 93°C (250 psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 132 mm (5.19") 0.5 m (1.5 ft) VP 240-236316L SS 10 bar at 155°C (150 psig at 311°F) 1.5" Tri-Clamp 316L SS 85 mm (3.35") – VP 243E233 d31 bar at 25°C (450 psig at 77°F)316L SS 10 bar at 155°C (150 psig at 311°F) 2" Tri-Clamp 316L SS 104 mm (4.10") – VP 243E237 d31 bar at 25°C (450 psig at 77°F)– Measuring range 0.002–200 µS/cm (cell constant 0.01 cm –1 ) aTitanium 17 bar at 93°C (250 psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 60 mm (2.38") 0.5 m (1.5 ft) S 240-101– Measuring range 50–40,000 µS/cm (cell constant 10 cm –1 ) aGraphite 17 bar at 93°C (250 psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 86 mm (3.38") 0.5 m (1.5 ft) S 240-4014-Electrode Sensors e– Measuring range 10–650,000 µS/cm316L SS d 5 bar at 150°C (70 psig at 302°F) 1.5" Tri-Clamp PEEK 25 mm (1.00") – VP 244-63314 bar at 50°C (200 psig at 122°F)316L SS d 5 bar at 150°C (70 psig at 302°F) 2" Tri-Clamp PEEK 25 mm (1.00") – VP 244-63414 bar at 50°C (200 psig at 122°F)Hastelloy C d 5 bar at 150°C (70 psig at 302°F) 1.5" Tri-Clamp PEEK 25 mm (1.00") – VP 244-63614 bar at 50°C (200 psig at 122°F)316L SS d 5 bar at 150°C (70 psig at 302°F) 1.5" Tri-Clamp PEEK 12 mm (0.50") – VP 244-63814 bar at 50°C (200 psig at 122°F)Hastelloy C d 7 bar at 93°C (100 psig at 200°F) 1" NPTM PEEK 28 mm (1.10") – VP 244-63014 bar at 25°C (200 psig at 77°F)316L SS d 3.5 bar at 80°C (50 psig at 176°F) 1" NPTM CPVC 28 mm (1.10") – VP 244-6317 bar at 25°C (100 psig at 77°F)Hastelloy C d 3.5 bar at 80°C (50 psig at 176°F) 1" NPTM CPVC 28 mm (1.10") – VP 244-6357 bar at 25°C (100 psig at 77°F)a MΩcm = 1/(µS/cm) S = Standard connector used with 1XXX-67 patch cords only.b See pages 32-33 for retractable housing (also used for pH and ORP) See page 54.c Tinned leads – no patch cord required VP = VarioPin sealed connector used with 58 080 20X patch cords onlyd Includes material certification to meet EN10204 3.1B & USP ClassVI (58 080 101 3-ft adapter cable can connect an existing 1XXX-67e 4-electrode sensor, maximum patch cord length 15m (50 ft) patch cord to a VP sensor). See page 54.METTLER TOLEDO US and Canada23
THORNTON Conductivity/Resistivity SensorsAccurate and ReliableConductivity/ResistivitySmart Conductivity Sensors for 770MAXDrawingsSee sensor table next page for "X" dimensions.www.mt.com/THORNTON-Cond24METTLER TOLEDO US and Canada
Microelectr.PowerPharma WaterOrdering InformationElectrode Maximum Pressure Process Connection Insertion Cable Order#Material – Fitting – Material Length "X" Length US/Canada2-Electrode Sensors– Measuring range 0.01–3,000µS/cm (cell constant 0.1cm –1 ) aTitanium 7 bar at 95°C (100psig at 203°F) 3 ⁄4" NPTM & PVDF 29 mm (1.14") 3 m (10ft) 230-20734 bar at 25°C (500psig at 77°F) 1" NPTMTitanium 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Noryl 29 mm (1.14") 0.5 m (1.5 ft) 230-210Titanium 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 34 mm (1.35") 0.5 m (1.5 ft) 230-211316L SS 4 bar at 131°C (58psig at 268°F) Retractable SS 70 mm (2.75") 3 m (10 ft) 230-2127 bar at 95°C (100psig at 203°F) for 1000-4X17 bar at 25°C (250psig at 77°F) housingTitanium 17 bar at 93°C (250psig at 200°F) 1 ⁄2" NPTM Teflon ® /SS 29 mm (1.14") 0.5 m (1.5 ft) 230-216Monel 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 34 mm (1.35") 0.5 m (1.5 ft) 230-251Monel 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 132 mm (5.19") 0.5 m (1.5 ft) 230-261Titanium 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 132 mm (5.19") 0.5 m (1.5 ft) 230-271Titanium b 10 bar at 155°C (150psig at 311°F) 1.5" Tri-Clamp Titanium 86 mm (3.38") 0.5 m (1.5 ft) 233E22131 bar at 25°C (450psig at 77°F)316L SS b 10 bar at 155°C (150psig at 311°F) 1.5" Tri-Clamp SS 86 mm (3.38") 0.5 m (1.5 ft) 233E22331 bar at 25°C (450psig at 77°F)316L SS b 10 bar at 155°C (150psig at 311°F) 2" Tri-Clamp SS 86 mm (3.38") 0.5 m (1.5 ft) 233E22731 bar at 25°C (450psig at 77°F)316L SS b 10 bar at 155°C (150psig at 311°F) ISO-DN25 bund SS 60 mm (2.37") 0.5 m (1.5 ft) 233E32331 bar at 25°C (450psig at 77°F)316L SS b 10 bar at 155°C (150 psig at 311°F) ISO-DN25 bund SS 70 mm (2.76") 0.5 m (1.5 ft) 233E32731 bar at 25°C (450psig at 77°F)– measuring range 0.001–100µS/cm (cell constant 0.01cm –1 ) aTitanium c 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 60 mm (2.38") 0.5 m (1.5 ft) 230-101– measuring range 10–200,000µS/cm (cell constant 10cm –1 ) aGraphite 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS/Noryl 87 mm (3.41") 0.5 m (1.5 ft) 230-431– measuring range 10–1,000KµS/cm (cell constant 50cm –1 ) aGraphite 7 bar at 93°C (100psig at 200°F) 1" NPTM PVDF/Epoxy 125 mm (4.90") 0.5 m (1.5 ft) 230-5314-Electrode Sensors– measuring range 10–800,000µS/cmHastelloy C b 7 bar at 93°C (100psig at 200°F) 1" NPTM PEEK 28 mm (1.10") 3 m (10 ft) 234-63014 bar at 25°C (200psig at 77°F)316L SS b 3.5 bar at 80°C (50psig at 176°F) 1" NPTM CPVC 28 mm (1.10") 3 m (10 ft) 234-6317 bar at 25°C (100psig at 77°F)Hastelloy C b 3.5 bar at 80°C (50 psig at 176°F) 1" NPTM CPVC 28 mm (1.10") 3 m (10 ft) 234-6357 bar at 25°C (100 psig at 77°F)316L SS b 14 bar at 50°C (200 psig at 122) 1.5" Tri-Clamp PEEK 25 mm (1.00") 0.5 m (1.5 ft) 234-6334.8 bar at 140°C (70 psig at 284°F)316L SS b 14 bar at 50°C (200 psig at 122) 2" Tri-Clamp PEEK 25 mm (1.00") 0.5 m (1.5 ft) 234-6344.8 bar at 140°C (70 psig at 284°F)Hastelloy C b 14 bar at 50°C (200 psig at 122) 2" Tri-Clamp PEEK 25 mm (1.00") 0.5 m (1.5 ft) 234-6364.8 bar at 140°C (70 psig at 284°F)316L SS b 14 bar at 50°C (200 psig at 122) 1.5" Tri-Clamp PEEK 12 mm (0.50") 0.5 m (1.5 ft) 234-6384.8 bar at 140°C (70 psig at 284°F)Certification of calibration included with all 0.1 and 0.01 cell constant and 4-E <strong>sensors</strong>; may be requested at additional cost on others.a MΩcm = 1/(µS/cm) b Includes material certification to meet EN10204 3.1B & USP Class VI c Recommended for non-aqueous samples770MAXPatch CordSmart Sensor Wiring (see page 58 )Smart SensorMETTLER TOLEDO US and Canada25