Thornton conductivity sensors
Thornton conductivity sensors
Thornton conductivity sensors
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Microelectr.PowerPharma WaterOrdering InformationElectrode Maximum Pressure Process Connection Insertion Cable Order#Material – Fitting – Material Length "X" Length US/Canada2-Electrode Sensors– Measuring range 0.01–3,000µS/cm (cell constant 0.1cm –1 ) aTitanium 7 bar at 95°C (100psig at 203°F) 3 ⁄4" NPTM & PVDF 29 mm (1.14") 3 m (10ft) 230-20734 bar at 25°C (500psig at 77°F) 1" NPTMTitanium 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Noryl 29 mm (1.14") 0.5 m (1.5 ft) 230-210Titanium 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 34 mm (1.35") 0.5 m (1.5 ft) 230-211316L SS 4 bar at 131°C (58psig at 268°F) Retractable SS 70 mm (2.75") 3 m (10 ft) 230-2127 bar at 95°C (100psig at 203°F) for 1000-4X17 bar at 25°C (250psig at 77°F) housingTitanium 17 bar at 93°C (250psig at 200°F) 1 ⁄2" NPTM Teflon ® /SS 29 mm (1.14") 0.5 m (1.5 ft) 230-216Monel 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 34 mm (1.35") 0.5 m (1.5 ft) 230-251Monel 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 132 mm (5.19") 0.5 m (1.5 ft) 230-261Titanium 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 132 mm (5.19") 0.5 m (1.5 ft) 230-271Titanium b 10 bar at 155°C (150psig at 311°F) 1.5" Tri-Clamp Titanium 86 mm (3.38") 0.5 m (1.5 ft) 233E22131 bar at 25°C (450psig at 77°F)316L SS b 10 bar at 155°C (150psig at 311°F) 1.5" Tri-Clamp SS 86 mm (3.38") 0.5 m (1.5 ft) 233E22331 bar at 25°C (450psig at 77°F)316L SS b 10 bar at 155°C (150psig at 311°F) 2" Tri-Clamp SS 86 mm (3.38") 0.5 m (1.5 ft) 233E22731 bar at 25°C (450psig at 77°F)316L SS b 10 bar at 155°C (150psig at 311°F) ISO-DN25 bund SS 60 mm (2.37") 0.5 m (1.5 ft) 233E32331 bar at 25°C (450psig at 77°F)316L SS b 10 bar at 155°C (150 psig at 311°F) ISO-DN25 bund SS 70 mm (2.76") 0.5 m (1.5 ft) 233E32731 bar at 25°C (450psig at 77°F)– measuring range 0.001–100µS/cm (cell constant 0.01cm –1 ) aTitanium c 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 60 mm (2.38") 0.5 m (1.5 ft) 230-101– measuring range 10–200,000µS/cm (cell constant 10cm –1 ) aGraphite 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS/Noryl 87 mm (3.41") 0.5 m (1.5 ft) 230-431– measuring range 10–1,000KµS/cm (cell constant 50cm –1 ) aGraphite 7 bar at 93°C (100psig at 200°F) 1" NPTM PVDF/Epoxy 125 mm (4.90") 0.5 m (1.5 ft) 230-5314-Electrode Sensors– measuring range 10–800,000µS/cmHastelloy C b 7 bar at 93°C (100psig at 200°F) 1" NPTM PEEK 28 mm (1.10") 3 m (10 ft) 234-63014 bar at 25°C (200psig at 77°F)316L SS b 3.5 bar at 80°C (50psig at 176°F) 1" NPTM CPVC 28 mm (1.10") 3 m (10 ft) 234-6317 bar at 25°C (100psig at 77°F)Hastelloy C b 3.5 bar at 80°C (50 psig at 176°F) 1" NPTM CPVC 28 mm (1.10") 3 m (10 ft) 234-6357 bar at 25°C (100 psig at 77°F)316L SS b 14 bar at 50°C (200 psig at 122) 1.5" Tri-Clamp PEEK 25 mm (1.00") 0.5 m (1.5 ft) 234-6334.8 bar at 140°C (70 psig at 284°F)316L SS b 14 bar at 50°C (200 psig at 122) 2" Tri-Clamp PEEK 25 mm (1.00") 0.5 m (1.5 ft) 234-6344.8 bar at 140°C (70 psig at 284°F)Hastelloy C b 14 bar at 50°C (200 psig at 122) 2" Tri-Clamp PEEK 25 mm (1.00") 0.5 m (1.5 ft) 234-6364.8 bar at 140°C (70 psig at 284°F)316L SS b 14 bar at 50°C (200 psig at 122) 1.5" Tri-Clamp PEEK 12 mm (0.50") 0.5 m (1.5 ft) 234-6384.8 bar at 140°C (70 psig at 284°F)Certification of calibration included with all 0.1 and 0.01 cell constant and 4-E <strong>sensors</strong>; may be requested at additional cost on others.a MΩcm = 1/(µS/cm) b Includes material certification to meet EN10204 3.1B & USP Class VI c Recommended for non-aqueous samples770MAXPatch CordSmart Sensor Wiring (see page 58 )Smart SensorMETTLER TOLEDO US and Canada25