12.07.2015 Views

Thornton conductivity sensors

Thornton conductivity sensors

Thornton conductivity sensors

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Microelectr.PowerPharma WaterOrdering InformationElectrode Maximum Pressure Process Connection Insertion Cable Order#Material – Fitting – Material Length "X" Length US/Canada2-Electrode Sensors– Measuring range 0.01–3,000µS/cm (cell constant 0.1cm –1 ) aTitanium 7 bar at 95°C (100psig at 203°F) 3 ⁄4" NPTM & PVDF 29 mm (1.14") 3 m (10ft) 230-20734 bar at 25°C (500psig at 77°F) 1" NPTMTitanium 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Noryl 29 mm (1.14") 0.5 m (1.5 ft) 230-210Titanium 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 34 mm (1.35") 0.5 m (1.5 ft) 230-211316L SS 4 bar at 131°C (58psig at 268°F) Retractable SS 70 mm (2.75") 3 m (10 ft) 230-2127 bar at 95°C (100psig at 203°F) for 1000-4X17 bar at 25°C (250psig at 77°F) housingTitanium 17 bar at 93°C (250psig at 200°F) 1 ⁄2" NPTM Teflon ® /SS 29 mm (1.14") 0.5 m (1.5 ft) 230-216Monel 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 34 mm (1.35") 0.5 m (1.5 ft) 230-251Monel 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 132 mm (5.19") 0.5 m (1.5 ft) 230-261Titanium 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 132 mm (5.19") 0.5 m (1.5 ft) 230-271Titanium b 10 bar at 155°C (150psig at 311°F) 1.5" Tri-Clamp Titanium 86 mm (3.38") 0.5 m (1.5 ft) 233E22131 bar at 25°C (450psig at 77°F)316L SS b 10 bar at 155°C (150psig at 311°F) 1.5" Tri-Clamp SS 86 mm (3.38") 0.5 m (1.5 ft) 233E22331 bar at 25°C (450psig at 77°F)316L SS b 10 bar at 155°C (150psig at 311°F) 2" Tri-Clamp SS 86 mm (3.38") 0.5 m (1.5 ft) 233E22731 bar at 25°C (450psig at 77°F)316L SS b 10 bar at 155°C (150psig at 311°F) ISO-DN25 bund SS 60 mm (2.37") 0.5 m (1.5 ft) 233E32331 bar at 25°C (450psig at 77°F)316L SS b 10 bar at 155°C (150 psig at 311°F) ISO-DN25 bund SS 70 mm (2.76") 0.5 m (1.5 ft) 233E32731 bar at 25°C (450psig at 77°F)– measuring range 0.001–100µS/cm (cell constant 0.01cm –1 ) aTitanium c 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS 60 mm (2.38") 0.5 m (1.5 ft) 230-101– measuring range 10–200,000µS/cm (cell constant 10cm –1 ) aGraphite 17 bar at 93°C (250psig at 200°F) 3 ⁄4" NPTM Teflon ® /SS/Noryl 87 mm (3.41") 0.5 m (1.5 ft) 230-431– measuring range 10–1,000KµS/cm (cell constant 50cm –1 ) aGraphite 7 bar at 93°C (100psig at 200°F) 1" NPTM PVDF/Epoxy 125 mm (4.90") 0.5 m (1.5 ft) 230-5314-Electrode Sensors– measuring range 10–800,000µS/cmHastelloy C b 7 bar at 93°C (100psig at 200°F) 1" NPTM PEEK 28 mm (1.10") 3 m (10 ft) 234-63014 bar at 25°C (200psig at 77°F)316L SS b 3.5 bar at 80°C (50psig at 176°F) 1" NPTM CPVC 28 mm (1.10") 3 m (10 ft) 234-6317 bar at 25°C (100psig at 77°F)Hastelloy C b 3.5 bar at 80°C (50 psig at 176°F) 1" NPTM CPVC 28 mm (1.10") 3 m (10 ft) 234-6357 bar at 25°C (100 psig at 77°F)316L SS b 14 bar at 50°C (200 psig at 122) 1.5" Tri-Clamp PEEK 25 mm (1.00") 0.5 m (1.5 ft) 234-6334.8 bar at 140°C (70 psig at 284°F)316L SS b 14 bar at 50°C (200 psig at 122) 2" Tri-Clamp PEEK 25 mm (1.00") 0.5 m (1.5 ft) 234-6344.8 bar at 140°C (70 psig at 284°F)Hastelloy C b 14 bar at 50°C (200 psig at 122) 2" Tri-Clamp PEEK 25 mm (1.00") 0.5 m (1.5 ft) 234-6364.8 bar at 140°C (70 psig at 284°F)316L SS b 14 bar at 50°C (200 psig at 122) 1.5" Tri-Clamp PEEK 12 mm (0.50") 0.5 m (1.5 ft) 234-6384.8 bar at 140°C (70 psig at 284°F)Certification of calibration included with all 0.1 and 0.01 cell constant and 4-E <strong>sensors</strong>; may be requested at additional cost on others.a MΩcm = 1/(µS/cm) b Includes material certification to meet EN10204 3.1B & USP Class VI c Recommended for non-aqueous samples770MAXPatch CordSmart Sensor Wiring (see page 58 )Smart SensorMETTLER TOLEDO US and Canada25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!