12.07.2015 Views

HM-3000 - Humboldt Mfg. Co.

HM-3000 - Humboldt Mfg. Co.

HM-3000 - Humboldt Mfg. Co.

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Data Acquisition & Software<strong>HM</strong>-2330MIniLogger<strong>HM</strong>-2325MIniLoggerInstrumentation<strong>Humboldt</strong> provides a complete range of instrumentationsolutions for all your testing needs.Make data collection from your existing load frame,consolidometer or other lab equipment simple andinexpensive with one of <strong>Humboldt</strong>’s MiniLoggers.The <strong>HM</strong>-2325A and <strong>HM</strong>-2330D MiniLoggers aresimple-to-use, four-channel, stand-alone, digital dataloggers specifically designed for use in Soil Testing(Triaxial, <strong>Co</strong>nsolidation, Direct Shear, CBR/LBRUnconfined <strong>Co</strong>mpression); Asphalt Testing (TSR,Hveem, Flow/Stability), and Cement Testing (Soil/Cement and Cement Cubes).<strong>Humboldt</strong> MiniLoggers increase lab productivity andcost effectiveness by freeing up technicians while testdata is recorded automatically. Both units are fullyconfigurable for automated start, stop and log-rateconditions; and can hold up to 1000 readings per test.Both units also include <strong>Humboldt</strong> Materials TestingSoftware (<strong>HM</strong>TS), which provides expanded controland reporting capabilities from a computer.Load RingsAvailable for use with mechanical dialgauges or digital indicators from110 lbf (.5kN) to 22,0000 lbf (100kN)S-type Load CellsAvailable in sizes from 500 lbf (2.5kN)to 10,0000 lbf (50kN) and comecomplete with calibration certificateand a 6.5 ft. (2m) cable.Strain TransducersAvailable in sizes 0.4" (10mm), 1.0"(25mm) and 2.0" (50mm) and areextremely accurate and reliable.Digital IndicatorsAvailable in sizes 0.6" (15mm), 1.0"(25 mm) and 2.0" (50mm) and areextremely accurate and reliable.Pressure TransducerDesigned specifically for geotechnicaltesting labs. Handles 200 psi (1400 kPa)and supplied with a 6.5 ft (2m) cable.Volume MeasurementTwo-part assembly provides measurementcontrol and limitless capacity forautomated systems.<strong>HM</strong>TS SoftwareData <strong>Co</strong>llection Software ModulesThe <strong>HM</strong>-<strong>3000</strong> MasterLoader, MiniLoggers and DirectShear machines come with <strong>Humboldt</strong>’s <strong>HM</strong>TS datacollection software. This software can be used to collectdata from tests by creating user-defined test parameters(start/stop). The resulting data collected can then betransferred to a computer and opened and viewed inMicrosoft Excel, as well as create a simple table and graph.Optional pre-defined reporting software modules andtemplates are available for specific tests, such as CBR,Triaxial, etc. These modules provide more control overstart and stop conditions for specific tests, as wellas provide extended reporting capabilities. <strong>Co</strong>ntact<strong>Humboldt</strong> for more information.


Test <strong>Co</strong>nfigurations<strong>Co</strong>nsolidation (Pneumatic)Typical Setups:PART # QTY DESCRIPTIONPneumatic <strong>Co</strong>nsolidation1 <strong>HM</strong>-2432 1 <strong>Co</strong>nmatic 32 TSF, 110/50-602 <strong>HM</strong>-1220.XX 1 Fixed Ring <strong>Co</strong>nsolidation Cell3 H-4471CC 1 Dial Indicator, 0.5" X .0001" CCPneumatic <strong>Co</strong>nsolidation w/ Analog Transducer Data Acquisition1 <strong>HM</strong>-2432 1 <strong>Co</strong>nmatic 32 TSF, 110/50-602 <strong>HM</strong>-1220.XX 1 Fixed Ring <strong>Co</strong>nsolidation Cell3 <strong>HM</strong>-2310.04 1 Strain Transducer 0.4" (10mm)4 <strong>HM</strong>-2310BR 1 Strain Transducer Bracket5 <strong>HM</strong>-2325A.3F 1 MiniLogger 4 CH Digital Data Acquisition6 <strong>HM</strong>-1100SW 1 <strong>Co</strong>nsolidation Reporting SoftwarePneumatic <strong>Co</strong>nsolidation w/ Digital Indicator Data Acquisition1 <strong>HM</strong>-2432 1 <strong>Co</strong>nmatic 32 TSF, 110/50-602 <strong>HM</strong>-1220.XX 1 Fixed Ring <strong>Co</strong>nsolidation Cell3 <strong>HM</strong>-4469.10 1 Digital Indicator 1" X .0001"4 <strong>HM</strong>-4469C 1 Data Cable for Indicator5 <strong>HM</strong>-2330D.3F 1 MiniLogger 4 CH Digital Data Acquisition6 <strong>HM</strong>-1100SW 1 <strong>Co</strong>nsolidation Reporting Software<strong>Co</strong>nsolidation (Dead Weight)Typical Setups:PART # QTY DESCRIPTIONDead Weight <strong>Co</strong>nsolidation1 <strong>HM</strong>-1100 1 Dead Weight <strong>Co</strong>nsol Frame-Front Load2 <strong>HM</strong>-1120* 1 Weight Set, 16 TSF3 <strong>HM</strong>-1220.XX 1 Fixed Ring <strong>Co</strong>nsolidation Cell4 H-4471CC 1 Dial Indicator, 0.5" X .0001" CCDead Weight <strong>Co</strong>nsolidation w/ Analog Data Acquisition1 <strong>HM</strong>-1100 1 Dead Weight <strong>Co</strong>nsol Frame-Front Load2 <strong>HM</strong>-1120* 1 Weight Set, 16 TSF3 <strong>HM</strong>-1220.XX 1 Fixed Ring <strong>Co</strong>nsolidation Cell4 <strong>HM</strong>-2310.04 1 Strain Transducer 0.4" (10mm)5 <strong>HM</strong>-2310BR 1 Strain Transducer Bracket6 <strong>HM</strong>-2325A.3F 1 MiniLogger 4 CH Analog Data Acquisition7 <strong>HM</strong>-1100SW 1 <strong>Co</strong>nsolidation Reporting SoftwareDead Weight <strong>Co</strong>nsolidation w/ Digital Data Acquisition1 <strong>HM</strong>-1100 1 Dead Weight <strong>Co</strong>nsol Frame-Front Load2 <strong>HM</strong>-1120* 1 Weight Set, 16 TSF3 <strong>HM</strong>-1220.XX 1 Fixed Ring <strong>Co</strong>nsolidation Cell4 <strong>HM</strong>-4469.10 1 Digital Dial Indicator 1" x .0001"5 <strong>HM</strong>-4469C 1 Data Cable for Indicator6 <strong>HM</strong>-2330D.3F 1 MiniLogger 4 CH Digital Data Acquisition7 <strong>HM</strong>-1100SW 1 <strong>Co</strong>nsolidation Reporting SoftwarePart Numbers ending in .XX require a size code to be enteredreferring to the sample size to be tested.*For Metric applications, use <strong>HM</strong>-1122, Weight Set, 32kg.For <strong>Co</strong>nsolidation samples, sizes are: .20 = 2.0"; .24 = 2.42";.25 = 2.5"; .30 = 3.0"; .40 = 4.0"; .50 = 50mm; .70 = 70mm;.75 = 75mm, and .100 = 100mm.Direct/Residual Shear (Pneumatic)Typical Setups:PART # QTY DESCRIPTIONPneumatic with Manual <strong>Co</strong>ntrol1 <strong>HM</strong>-2550 1 Pneumatic Direct Shear Set 110V2 <strong>HM</strong>-2701.XX(S/D) 1 Shearbox Assembly4 <strong>HM</strong>-2702.XX(S/D) 1 Shearbox Cutter5 <strong>HM</strong>-2703.XX(S/D) 1 Dolly/TamperPneumatic, <strong>Co</strong>mputer <strong>Co</strong>ntrol with Analog Transducer1 <strong>HM</strong>-2560A.3F 1 ShearScan 10, w/ Analog Inputs2 <strong>HM</strong>-2701.XX(S/D) 1 Shearbox Assembly3 <strong>HM</strong>-2702.XX(S/D) 1 Shearbox Cutter4 <strong>HM</strong>-2703.XX(S/D) 1 Dolly/Tamper5 <strong>HM</strong>-2300.020 1 S-Type Load Cell 2,000#6 <strong>HM</strong>-2310.10 1 Strain Transducer 1" (25mm)7 <strong>HM</strong>-2310.04 1 Strain Transducer 0.4" (10mm)8 <strong>HM</strong>-2310BR 2 Strain Transducer Bracket9 <strong>HM</strong>-2700SW 1 DS Reporting SoftwareDirect/Residual Shear (Dead Weight)Typical Setups:PART # QTY DESCRIPTIONDead Weight with Manual <strong>Co</strong>ntrol1 <strong>HM</strong>-2700.3F 1 Direct Residual Shear Apparatus 10:12 <strong>HM</strong>-2701.XX(S/D) 1 Shearbox Assembly3 <strong>HM</strong>-2702.XX(S/D) 1 Shearbox Cutter4 <strong>HM</strong>-2703.XX(S/D) 1 Dolly/Tamper5 H-4454.020 1 Load Ring, 2,200 lbf S/N6 H-4158.1 1 Dial Indicator, 1.000"7 H-4471CC 1 Dial Indicator, 0.5" X .0001"8 <strong>HM</strong>-1120* 1 Weight Set, 16 TSFDead Weight, w/ Analog Transducer Data Acquisition1 <strong>HM</strong>-2700A.3F 1 Direct Shear w/ Analog Inputs2 <strong>HM</strong>-2701.XX(S/D) 1 Shearbox Assembly3 <strong>HM</strong>-2702.XX(S/D) 1 Shearbox Cutter4 <strong>HM</strong>-2703.XX(S/D) 1 Dolly/Tamper5 <strong>HM</strong>-2300.020 1 S-Type Load Cell 2,000#6 <strong>HM</strong>-2310.10 1 Strain Transducer 1" (25mm)7 <strong>HM</strong>-2310.04 1 Strain Transducer 0.4" (10mm)8 <strong>HM</strong>-2310BR 2 Strain Transducer Bracket9 <strong>HM</strong>-1120* 1 Weight Set, 16 TSF10 <strong>HM</strong>-2700SW 1 Direct Shear Reporting SoftwareDead Weight, w/ Digital Dial Gauge Data Acquisition1 <strong>HM</strong>-2700D.3F 1 Direct Shear w/ Digital Inputs2 <strong>HM</strong>-2701.XX(S/D) 1 Shearbox Assembly3 <strong>HM</strong>-2702.XX(S/D) 1 Shearbox Cutter4 <strong>HM</strong>-2703.XX(S/D) 1 Dolly/Tamper5 H-4454.020D 1 Load Ring, Digital 2200LBF6 <strong>HM</strong>-4469.10 2 Digital Indicator 1" X .0001"7 <strong>HM</strong>-4469C 3 Data Cable for Indicator8 <strong>HM</strong>-1120* 1 Weight Set, 16 TSF9 <strong>HM</strong>-2700SW 1 Direct Shear Reporting SoftwareFor Direct/Residual Shear samples, sizes are: .20 = 2.0"; .24 = 2.42";.25 = 2.5"; .40 = 4.0"; .50 = 50mm; .60 = 60mm, and .100 = 100mm.NOTE: For Direct/Residual Shear, also, use "S" for square and"D" for round samples.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!