<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong>CABINETswww.lande.com.tr1


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong>FAMILYW=600mm <strong>NETbox</strong> <strong>Series</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong><strong>NETbox</strong> series Networking Enclosures/<strong>Cabinets</strong>, provide maximum optimizationresulted to an optimum performance inbetween quality and added value.While product gives maximum performanceon cabling and networking infrastructure, inparallel provides a very respective economycompared to its quality which is based onhigh technologic fully automated industry.The 600x450, 600x600 and D:150mm RearSection Modules possible to integrate tod:450mm preferably and either to d:600mm.<strong>NETbox</strong> <strong>Wall</strong> Cabinet series is available in 5heights from 7U through to 20U, Eachcabinet is supplied as standard with a glassfront door, mechanically screwed steel rearpanel and lift off steel side panels, all ofwhich are lockable.The wide product height portfolio meets anyU requirement in infrastructure needs.<strong>NETbox</strong> series have a professional technicalbut aesthetic look with decorativeAluminium Extruded Housing on the frontdoor; the product range attracts the attentionwith the mostly environmentally fit andselected color of RAL 9005 Black, and RAL7035 Light Grey, with fine wrinkle softtouch paint. Anthracite Grey DecorativeABS (Acrylonitrile Butadiene Styrene)material header Unit with art design on PVCprovides an aesthetic visuality.The product range allows with 150mmextention module integration where 4 wayaccess is the question for wall applications.Completely standard and stocked productportfolio, being delivered a single pieceassembled product, as shipping configurationthe one set: 2pieces 19’’ adjustableequipment mounting rails included.<strong>NETbox</strong> <strong>Series</strong> product range with optimalpanel mounting size, and a variety range ofaccessories enclose the whole expectation ofusers.www.lande.com.tr2


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong>FAMILYCONSTRUCTION DETAILS:Main Profile- Framework- Top/Bottom Cases, ABS FanHousing:Multi Folded Automated Bending technology applied cornerprofile system, provides a heavy duty structure results to highload capacity of: 80 kgs on wall.Monoblock multi folded top and bottom cases 20 timesbended resulted to a very heavy construction, tightly fixed tothe framework with fixing hardware , fully modular systemgenerated.Top case has a ready Forced Ventilation (Fan Module)integration ABS housing. Fan Module installation can beoperated either from roof or from internal side of cabinet.The advantage of this system is, once the Fan Unit needsmaintenance or replacement and while the cabinet is carryingintegrated active and passive networking devices, than subjectto remove some of them to replace the Fan Module Unit.Lande Cabinet Fan Module Unit access is from roof where nointerference with the already installed components insidecabinets. Decorative Anthracite Grey ABS Fan Moduleintegration housing replacement is toolless. Where the FanModule to be inserted to the ABS Fan Module Housingwithout any tool.Top case integrated with a cable entry point with rubber edgedsliding mechanism with w:145mmxd:70mm allows propercabling insertion. The rubber edged mechanism worksbetween 0 to 50mm slide out.After inserting the cables, the rubber edged mechanism holdsand fixes the cables in parallel preventing the cabinet fromdust entry.Top Case, has ventilation slots at sides which provides passiveair ventilation via convention. Once the cabinet is notequipped with forced ventilation ( Fan Units ), this ABS FanHousing also provides passive ventilation via convection.Top Case and Main Frame junctions are closed withAnthracite Grey PVC application for aesthetical appearance.www.lande.com.tr3


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong>FAMILYCONSTRUCTION DETAILS:Access to enclosure:Front door is integrated with decorative 2,5mm thicknessaluminium extruded frames, full length smoked , shatterproof,antistatic, 4,0mm thickness glass with single point locking barrellock.Front door Aluminium extruded frame allows , decorative PVCStripes charming the attraction, Anthracite Grey for RAL 7035Light Grey <strong>Cabinets</strong> and Light Grey for RAL 9005 BlackcabinetsFront door openning direction is set right to left, but reversibleto left to right at site with removing the hinge system. HingeSystem is spring loaded easy operating version, which allowsyou to remove the whole front door from cabinet in seconds.Alternative doors ( Curved Glass and Solid Metal) are availablefor customer selection. *** Please see door options at the end ofeach product size.Side Panels are lockable and removable with barrel style lock,Multifolded bending technology with 8 fold bending providesthe rigidity. Easy mechanical locking of panel to main framewith snap capture sytem allows easy attachment of panels andeasy removal in seconds while installation in process.Rear Panels are mechanically screwed to main module, which isMultifolded bending technology with 5 fold bending providedthe rigidity.Rear Panel can be used for wall fixing and drilling pattern.Bottom case and Rear Panel integrated with PVC gland plate.Once needed gland plate and rubber edged sliding mechanismcould be replaced on site19’’ rails of Lande <strong>NETbox</strong> <strong>Series</strong> <strong>Wall</strong> cabinet are withautomated silk-screen U numbering, depends on size 1U to 20U,same from top to bottom or bottom to top results to same Uheight selection. No matter where you have started countingfrom. 19’’ rails are 4 fold bending surfaces, 1,5mm thicknessprovides the high load capacities. The 19’’ rails are made ofsteel with 8-12 micron zinc plating for corrosion resistance. 19’’rails are adjustable in depth. For easy adjustment purpose, noneed to detach the screws, just ease the screws and slide them inthe channels on the top/bottom chasis bends.All design features provide 3 way access to your enclosure andequipments, easy to reach to enclosure and equipments for allinfrastucture installations and maintenance needs.www.lande.com.tr4


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong>FAMILYADDITIONAL FEATURES:<strong>NETbox</strong> <strong>Wall</strong> cabinets has an ABS Decorative header unit,where has a placement for the Digital Thermometer with 1meter cable probe, integrated with 2 lithium battery with 2year life, measurement once for every minute as accessory tobe ordered.<strong>NETbox</strong> <strong>Wall</strong> cabinets has sticky colour changing thermometer,range 20 to 40 C; as an accessory.<strong>NETbox</strong> <strong>Wall</strong> <strong>Cabinets</strong> has a decorative ABS header unit. Forvolume orders or projects, please coordinate with salesdepartment to select any other color application than AnthraciteGrey standard offer by Lande.Your company corporate colors are applicable!<strong>NETbox</strong> <strong>Wall</strong> <strong>Cabinets</strong> have mechanically screwed rearpanel. The panel can be used as wall fixing pattern on wall.This feature provides cost efficieny at site applications wherea heavy enclosure to be fixed to wall. At least 2 techniciansneeded in standard. Lande <strong>NETbox</strong> cabinets are applicablewith one technician at site only.First the rear panel to be placed on wall for marking purposes,than drilling to be operated, finally the rear panel to be fixedon wall without the main cabinet unit.Finally the cabinet to be hanged over the rear panel. For safetyreasons the screwing must be completed. Without screws evencabinet safely should stay on wall.<strong>NETbox</strong> wall cabinets offers one more advantage for siteapplication, the internal active and passive components can beassembled to cabinet on the workshop. Afterwards wallfixation can be the process follows. Only the connection of thecables and power to be operated. This would be a big advantagefor technicians while the <strong>Wall</strong> cabinet to be assembled tovery high placements and locations especially in factory orwarehouse conditions, where distribution infrastructure incabinet to be completed at 4 to 8 meter highRear Panels are mechanically screwed to main module, whichis Multifolded bending technology with 5 fold bendingprovided the rigidity.Rear Panel can be used for wall fixing and drilling pattern.www.lande.com.tr5


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong>FAMILYADDITIONAL FEATURES:All Lande <strong>NETbox</strong> <strong>Wall</strong> <strong>Cabinets</strong> are proper to integrate withcaster group or Adjustable leveling feet group. This featureprovides a possibility of using wall cabinets as for free standingpurposes, especially where the narrow places are the case. Aswell integration with caster group or PVC adjustable levelingfeet group provides a possibility to use the cabinet for underdeskapplications.Please see detailed description in accesorry section.Part numbers to order:*** LN-ZMN-TKR-5020-XX for Caster Group SetLN-ZMN-PNY-1040-XX for PVC Leveling Feet Group SetOnce using the Lande <strong>NETbox</strong> wall cabinets for Free standingpurposes, and access from rear of the enclosure is mandatoryrequest of integration, than please find the hinged rear dooroption instead of screwed panel option at the end of eachproduct size.Lande <strong>NETbox</strong> wall cabinets are being delivered with 1set: 2pcs19’’ Rails.Once a 4 point fixing shelf or any other 4 point fixing equipmentto be installed, an additional set of 19’’ rails to be ordered. Withthis application it is possible to locate some deeper networkingdevices as well some heavy equipments like UPS’s etc.Part numbers to order:***LN-PRF-CMD-xx UD-ZNDefine xx as the U height of intended <strong>NETbox</strong> wall cabinet tobe usedExample Part Nr: LN-PRF-CMD-07UD-ZNPlease see detailed description in accesorry section.Lande <strong>NETbox</strong> wall cabinets are in RAL 7035 Light Grey colorfrom stock.Black RAL 9005 Color application is possible. Pleaseco-ordinate with sales department of Lande for Black requestespecially for projects and concrete requests of customers.www.lande.com.tr6


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> Width: 600 mm.Depth: 450 mm.Width=600mmDepth=450mmStandard Heights:5 different U heights:Load Capacity: 80 kgs.07U, 09U, 12U, 16U, 20UStandards, and Compliances:ISO 9001:2008Quality Management SystemEN 61587 -1:2012Mechanical Structures forElectronic EquipmentIEC 297-1, 19’’ mountingIEC 297-2 Overall cabinet dimentionsCE conform toEN 60950-1:2006Information TechnologyEquipment – Safety – Part-1-General Requirements100% RECYCLABLEEnvironment Friendly;*Environmental awareness*RoHS compliancy*% 100 RecyclableMaterial<strong>NETbox</strong> series <strong>Wall</strong> <strong>Mounting</strong>Networking Enclosures, with19’’ w:600mm and d:450mmphysical sizes, with max internalusable depth, and 5 differentheight, gives a wide selectionchart for users.All Lande <strong>NETbox</strong> <strong>Wall</strong>cabinets are being delivered as asingle piece pre-assembledenclosure, with standard factorysettings.For Decoratively fitting toenvironment of your livingareas, the cabinet has beenintegrated with highly modern,art fragrant parts and accessories.For door and panel variations fordifferent purpose of usage,*** Please see door options atthe end of each product size.Standard Color:RAL 7035 Light Grey(Stock Delivery)Optional Color:RAL 9005 Blackwww.lande.com.tr7


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> Width: 600 mm.Depth: 450 mm.CONSTRUCTIONDRAWINGCONSTRUCTIONDRAWINGEXPLODED VIEW6000-5070145Max 385 / Min 325 / Std 345145 709,545044,45(1U)hHMax 115 / Min 55 / Std 954510 -228FRONT DOOROPENING ANGLEMAX/STD/MIN EQUIPMENTMOUNTING DISTANCEDIMENSIONS INWIDTH AND HEIGHTROOT ProductNumber ***Product DescriptionLN-WM07U6045-LG-111LN-WM09U6045-LG-111LN-WM12U6045-LG-111LN-WM16U6045-LG-1117U 19'' <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=450mm9U 19'' <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=450mm12U 19'' <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=450mm16U 19'' <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=450mm600x450x423600x450x512600x450x646600x450x824LN-WM20U6045-LG-111 20U 19'' <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=450mm 600x450x1001<strong>NETbox</strong> <strong>Series</strong> <strong>Wall</strong> <strong>Mounting</strong> 19'' <strong>Cabinets</strong> W=600mm D=450mm* Please add 30mm to H mm once used with leveling feet, add 60mm to H mm once used with castor set.** See min and max Adjustable depth variations on drawings***CC= LG for Light Grey RAL 7035 & BL for Black RAL 9005 for customers to define while ordering, for ''111'' selection please see the door optionsSize WXDXHmmh size in U7U9U12U16U20Uh in mm311400533711889*H mm, overallwithout feet and/orcastor4235126468241001Width Overallmm600600600600600Ah <strong>Wall</strong> <strong>Mounting</strong>h mm260349482660838Width Rail toRailDepth Overallmm**Depth Shipping Conf.Rail to Rear Panel mm19” 45019” 45019” 45019” 45019” 450345345345345345QTY INPACKAGE11111PACKINGDIMENTIONSWXDXH mm620x470x450620x470x540620x470x670620x470x850620x470x1030Standard NETWeight of product kgsGross Weight ofProduct kgs13162124301417222632QTY INPALETTE201612108PALETTEDIMENTIONSWXDXH mmPalette Weight kgs1100x1300x2400 3021100x1300x2280 2941100x1300x2150 2861100x1300x2450 2821100x1300x2250 278www.lande.com.tr9


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> Width: 600 mm.Depth: 450 mm.DOOROPTIONS12321<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=450mmAll Heights FRONT DOOR Options1 Single Openning, Flat Shape, Side Framed Glass Front Door,Single Point Barrel Locking.2 Single Openning, Flat Shape, Complete Solid Metal Front Door,Single Point Barrel Locking3 Single Openning, Curved Shape, Side Framed Glass Front Door,Single Point Barrel Locking.<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=450mmAll Heights REAR DOOR Options1 Factory Configurated Screwed and Mechanically Locked RearPanel included2 Hinged and barrel single point locking rear door<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> CabinetW=600mm D=450mmAll Heights SIDE PANEL Options1 NO Option, FactoryConfigurated Side Panels areincludedLN-AA XXU WW DD CC 000LN Corporate codification beginning lettersmentioning Lande in Short Format as LNAA Family Group of Enclosure; FS for FreeStanding cabinets, WM for <strong>Wall</strong> <strong>Mounting</strong><strong>Cabinets</strong>, SH for Small office Home office Range,SR for Server enclosure Range, SL for Slim series,RS for Home series wall cabinetsXX Numeric Character defining the height ofenclosures, depending on model differencesbetween 12 to 45 to be selected from price list,website or catalogueU U Height Alfanumeric Notation, concrete ( noneditable- fixed character)WW The First 2 digits of the width info, 60 forW=600mm, 80 for W=800mm, 54 forW=540mm, 30 for W=300mm Soho 10''enclosureDD The First 2 digits of the depth info, 45 forD=450mm, 40 for D=400mm, 60 for D=600mm,80 for D=800mm, 10 for D=1000mm cabinetsCC Color Code, LG for Light Grey RAL 7035,BL for Black RAL 90050 Front Door Variation number, numeric character 1 to 9 / 0 means no front door,standard front door defined in Lande System as option 1., Please select othervariations if needed from above door selection drawing. Unless defined option 1should be delivered0 Rear Door Variation number, numeric character 1 to 9 / 0 means no rear door,standard rear door defined in Lande System as option 1., Please select othervariations if needed from above door selection drawing. Unless defined option 1should be delivered0 Side Panel/Door Variation number,numeric character 1 to 9 / 0 means no sidepanel on product, standard side panel/door defined in Lande System as option 1.Unless defined option 1 should be deliveredwww.lande.com.tr10


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> Width: 600 mm.Depth: 600 mm.Width=600mmDepth=600mmStandard Heights:Load Capacity: 80 kgs.5 different U heights:07U, 09U, 12U, 16U, 20UStandards, and Compliances:ISO 9001:2008Quality Management SystemEN 61587 -1:2012Mechanical Structures forElectronic EquipmentIEC 297-1, 19’’ mountingIEC 297-2 Overall cabinet dimentionsCE conform toEN 60950-1:2006Information TechnologyEquipment – Safety – Part-1-General Requirements100% RECYCLABLEEnvironment Friendly;*Environmental awareness*RoHS compliancy*% 100 RecyclableMaterial<strong>NETbox</strong> series <strong>Wall</strong> <strong>Mounting</strong>Networking Enclosures, with19’’ w:600mm and d:600mmphysical sizes, with max internalusable depth, and 5 differentheight, gives a wide selectionchart for users.All Lande <strong>NETbox</strong> <strong>Wall</strong>cabinets are being delivered as asingle piece pre-assembledenclosure, with standard factorysettings.For Decoratively fitting toenvironment of your livingareas, the cabinet has beenintegrated with highly modern,art fragrant parts and accessories.For door and panel variations fordifferent purpose of usage,*** Please see door options atthe end of each product size.Standard Color:RAL 7035 Light Grey(Stock Delivery)Optional Color:RAL 9005 Blackwww.lande.com.tr11


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> Width: 600 mm.Depth: 600 mm.DETAILS ONEXPLODED VIEWBOTTOM VIEWISOMETRIC VIEW440AhFRONT VIEW SIDE VIEW REAR VIEWTOP VIEWEXPLODED VIEWwww.lande.com.tr12


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> Width: 600 mm.Depth: 600 mm.DOOROPTIONS12321<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=600mmAll Heights FRONT DOOR Options1 Single Openning, Flat Shape, Side Framed Glass Front Door,Single Point Barrel Locking.2 Single Openning, Flat Shape, Complete Solid Metal Front Door,Single Point Barrel Locking3 Single Openning, Curved Shape, Side Framed Glass Front Door,Single Point Barrel Locking.<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=600mmAll Heights REAR DOOR Options1 Factory Configurated Screwed and Mechanically Locked RearPanel included2 Hinged and barrel single point locking rear door<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> CabinetW=600mm D=600mmAll Heights SIDE PANEL Options1 NO Option, FactoryConfigurated Side Panels areincludedLN-AA XXU WW DD CC 000LN Corporate codification beginning lettersmentioning Lande in Short Format as LNAA Family Group of Enclosure; FS for FreeStanding cabinets, WM for <strong>Wall</strong> <strong>Mounting</strong><strong>Cabinets</strong>, SH for Small office Home office Range,SR for Server enclosure Range, SL for Slim series,RS for Home series wall cabinetsXX Numeric Character defining the height ofenclosures, depending on model differencesbetween 12 to 45 to be selected from price list,website or catalogueU U Height Alfanumeric Notation, concrete ( noneditable- fixed character)WW The First 2 digits of the width info, 60 forW=600mm, 80 for W=800mm, 54 forW=540mm, 30 for W=300mm Soho 10''enclosureDD The First 2 digits of the depth info, 45 forD=450mm, 40 for D=400mm, 60 for D=600mm,80 for D=800mm, 10 for D=1000mm cabinetsCC Color Code, LG for Light Grey RAL 7035,BL for Black RAL 90050 Front Door Variation number, numeric character 1 to 9 / 0 means no front door,standard front door defined in Lande System as option 1., Please select othervariations if needed from above door selection drawing. Unless defined option 1should be delivered0 Rear Door Variation number, numeric character 1 to 9 / 0 means no rear door,standard rear door defined in Lande System as option 1., Please select othervariations if needed from above door selection drawing. Unless defined option 1should be delivered0 Side Panel/Door Variation number,numeric character 1 to 9 / 0 means no sidepanel on product, standard side panel/door defined in Lande System as option 1.Unless defined option 1 should be deliveredwww.lande.com.tr14


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> offered asFree Standing purpose CASE STUDYWidth: 600 mm.Depth: 600 mm.Width=600mmDepth=600mmStandard Heights:2 different U heights:22U, 26ULoad Capacity: 80 kgs.Standards, and Compliances:ISO 9001:2008Quality Management SystemEN 61587-1 –Mechanical Structures, cabinetsfor electronic equipmentsIEC 297-1, 19’’ mountingIEC 297-2 Overall cabinet dimentionsCE conform toEN 60950-1:2006Information TechnologyEquipment-Safety-Part-1-General Requirements100% RECYCLABLEEnvironment Friendly;*Environmental awareness*RoHS compliancy*% 100 RecyclableMaterialStandard Colors:RAL 9005 BlackRAL 7035 Light GreyFor Project case applications, Lande <strong>NETbox</strong> <strong>Wall</strong> cabinets are beingproduced at 22U and 26U 600x600 mm sizes. These product sizes arenot kept in stock. With hinged rear door application, as well castergroup and leveling feet set added configuration should perform 80 kgon wall with a wall support kit, and up to 300 kgs on the floor.*** Please see door options at the end of each product size.www.lande.com.tr15


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> offered asFree Standing purpose CASE STUDYWidth: 600 mm.Depth: 600 mm.CASE STUDYDRAWINGS525550M10BOTTOM VIEW440Ah600FRONT VIEW SIDE VIEW REAR VIEW600600600TOP VIEWwww.lande.com.tr16


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> offered asFree Standing purpose CASE STUDYWidth: 600 mm.Depth: 600 mm.70145ISOMETRIC VIEWEXPLODED VIEW9,56000-5070Max 100 / Min 40 / Std 10044,45(1U)hH145600Max 495 / Min 375 / Std 375451Max 115 / Min 55 / Std 1150 -235FRONT DOOROPENING ANGLEMAX/MIN/STDEQUIPMENTMOUNTING DISTANCEDIMENSIONS INWIDTH AND HEIGHT<strong>NETbox</strong> <strong>Series</strong> <strong>Wall</strong> <strong>Mounting</strong> 19'' <strong>Cabinets</strong> W=600mm D=600mm / 22U & 26UROOT ProductNumber ***LN-WM22U6060-CC-111LN-WM26U6060-CC-111LN-WM22U6060-CC-121LN-WM26U6060-CC-121LN-RAF-RAY-WM-CCProduct Description22U 19'' <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=600mmWith Rear Panel, 4 pcs equipment mounting rails26U 19'' <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=600mmWith Rear Panel, 4 pcs equipment mounting rails22U 19'' <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=600mmWith Hınged and barrel locking Rear Door, 4 pcsequipment mounting rails26U 19'' <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=600mmWith Hınged and barrel locking Rear Door, 4 pcsequipment mounting rails<strong>Wall</strong> Support Kit for 22U and 26U Size W= 600mmD= 600mm, Recommended to Use on <strong>Wall</strong> 1 Set 2 pcs* Please add 30mm to H mm once used with leveling feet, add 60mm to H mm once used with castor set.** See min and max Adjustable depth variations on drawings.***CC= LG for Light Grey RAL 7035 & BL for Black RAL 9005 for customers to define while ordering, for ''111'' selection please see the door options.Size WXDXHmm600x600x1090600x600x1268600x600x1090600x600x1268250x250x50h size in U22U26U22U26U-h in mm1004118110041181-*H mm, overallwithout feet and/orcastor1090126810901268-Width Overallmm600600600600-Ah <strong>Wall</strong> <strong>Mounting</strong>h mm9271105---Width Rail toRailDepth Overallmm19”19”19”19”-600600600600-**Depth Shipping Conf.Rail to Rail mm375375375375-QTY INPACKAGEPACKINGDIMENTIONSWXDXH mmCONSTRUCTIONDRAWING11111 setStandard NETWeight of product kgs620x620x1120 34,5620x620x1300 39,5620x620x1120620x620x1300260x260x11036401,8Gross Weight ofProduct kgs364137422QTY INPALETTE8686-PALETTEDIMENTIONSWXDXH mm1300x1300x23801300x1300x20501300x1300x23801300x1300x2050-Palette Weight kgs314275310269-www.lande.com.tr17


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> offered asFree Standing purpose CASE STUDYWidth: 600 mm.Depth: 600 mm.CASE STUDYDRAWINGSISOMETRIC VIEWWITHLEVELING FEETISOMETRIC VIEWWITHCASTER SETISOMETRIC VIEW WITH WALL SUPPORT BRACKETSISOMETRIC REAR VIEWWITH LEVELING FEET WITHHINGED REAR DOORISOMETRIC REAR VIEWWITH CASTER SET WITHHINGED REAR DOOR<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=600mmFRONT DOOR Options<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> Cabinet W=600mm D=600mmREAR DOOR Options<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> CabinetW=600mm D=600mmSIDE PANEL Options1 Single Openning, Flat Shape, Side Framed Glass Front Door, Single PointBarrel Locking.2 Single Openning, Flat Shape, Complete Solid Metal Front Door, SinglePoint Barrel Locking3 Single Openning, Curved Shape, Side Framed Glass Front Door, SinglePoint Barrel Locking.1 Factory Configurated Screwed and Mechanically LockedRear Panel included2 Hinged and barrel single point locking rear door1 NO Option, FactoryConfigurated Side Panels areincludedLN-AA XXU WW DD CC 000LN Corporate codification beginning lettersmentioning Lande in Short Format as LNAA Family Group of Enclosure; FS for FreeStanding cabinets, WM for <strong>Wall</strong> <strong>Mounting</strong><strong>Cabinets</strong>, SH for Small office Home office Range,SR for Server enclosure Range, SL for Slim series,RS for Home series wall cabinetsXX Numeric Character defining the height ofenclosures, depending on model differencesbetween 12 to 45 to be selected from price list,website or catalogueU U Height Alfanumeric Notation, concrete ( noneditable- fixed character)WW The First 2 digits of the width info, 60 forW=600mm, 80 for W=800mm, 54 forW=540mm, 30 for W=300mm Soho 10''enclosureDD The First 2 digits of the depth info, 45 forD=450mm, 40 for D=400mm, 60 for D=600mm,80 for D=800mm, 10 for D=1000mm cabinetsCC Color Code, LG for Light Grey RAL 7035,BL for Black RAL 90050 Front Door Variation number, numeric character 1 to 9 / 0 means no front door,standard front door defined in Lande System as option 1., Please select othervariations if needed from above door selection drawing. Unless defined option 1should be delivered0 Rear Door Variation number, numeric character 1 to 9 / 0 means no rear door,standard rear door defined in Lande System as option 1., Please select othervariations if needed from above door selection drawing. Unless defined option 1should be delivered0 Side Panel/Door Variation number,numeric character 1 to 9 / 0 means no sidepanel on product, standard side panel/door defined in Lande System as option 1.Unless defined option 1 should be deliveredwww.lande.com.tr18


19” <strong>NETbox</strong> Double Section forWALL MOUNTING CABINETSFEATURES of Rear <strong>Wall</strong> Section:All Lande <strong>NETbox</strong> <strong>Wall</strong> <strong>Cabinets</strong> are proper for Rear SectionUnit.Rear Section is Heavy Duty Welded framed construction. 2,0mmthickness material welded as multi layer system creates at wallfixing provision a thickness of 4,0mm.A PVC cable entry gland plate is available at the wall sidewelcomes if any cable comes up from wall, and back section tobe align directly to the provision of cable run through.19’’ provision located at rear section module, which allows if anypassive less depth cabling component needs to be housed, whilethe cable bundles could be housed inside the 100mm depth emptyhousing box.Triangular, positioning brackets buried into the 100mm rearhousing box for allignment and raising a heavy load capability.Spanner style special locking mechanism captures the rear100mm box, in the welded 50mm depth frame, which integratesthe rear section to the main <strong>NETbox</strong> wall cabinet.Top and Bottom of the rear section module has cable entrycut-outs closed with Brushed cable entry provisions.A spesific flange system designed for heavy duty structure,where 50kgs of front <strong>NETbox</strong> wall cabinet total load is beingcarried without any problem. The 50 kgs of load capacity existsand performs while cabinet is in swinging position.*** 50 kgs load capacity measured at integrated frontal wallcabinet of d:450mm<strong>NETbox</strong> Rear Section Module, can be integrated to d:450mmversion wall mounting cabinet, which overall cabinet dimentionto be 450+150=600mm, the load capacity is 50kgsOnce a deeper equipment to be fitted for the same purposes,<strong>NETbox</strong> Rear Section can be integrated to d:600mm version wallmounting cabinet, which overall cabinet dimention to be600+150=750mm, the load capacity is loosing at a rate of % 30,than 35 kgs of load could be operated at swinging position.*** At 600 + 150mm configuration, recommended to use for freestanding purposes.<strong>NETbox</strong> Rear Section Units are being sold as a seperate Unit,later to be integrated to any of available <strong>NETbox</strong> wall mountingcabinet. This feature simply offers a flexibility and availabilitysince if there is stocked wall mounting cabinet available inwarehouses, customer should need to order only the Rear SectionUnit. After removing the rear panel of existing <strong>Wall</strong> mountingcabinet, only 4 screws to be tighten again for integration of RearSection Unit.<strong>NETbox</strong> Rear section swinging direction could be managedeasily, due to assemly placement availability, openning left toright or right to left is not a problem.Lande <strong>NETbox</strong> Rear Sections are in RAL 7016 AnthraciteGrey color from stock.www.lande.com.tr19


19” <strong>NETbox</strong> Double Section forWALL MOUNTING CABINETSADDITIONAL FEATURES of Rear Section integrated<strong>NETbox</strong> DOUBLE SECTION WALL MOUNTINGCABINETS:The Feature of integration with Caster group or PVC adjustableleveling feet group is applicable for double section wall mountingcabinet if intended to use as free standing cabinet purposes.Please see detailed description in accesorry section.Part numbers to order:*** LN-ZMN-TKR-5020-XX for Caster Group SetLN-ZMN-PNY-1040-XX for PVC Leveling Feet Group SetOnce using the Lande <strong>NETbox</strong> double section wall cabinets forFree standing purposes, and access from rear of the enclosurecould be managed by swinging capability of rear section.Lande <strong>NETbox</strong> wall cabinets are being delivered with 1set: 2pcs19’’ Rails.Once a 4 point fixing shelf or any other 4 point fixing equipmentto be installed in double section wall mounting cabinets, anadditional set of 19’’ rails to be ordered. With this application it ispossible to locate some deeper networking devices as well someheavy equipments like UPS’s etc.Part numbers to order:***LN-PRF-CMD-xx UD-ZNDefine xx as the U height of intended <strong>NETbox</strong> wall cabinet to beusedExample Part Nr: LN-PRF-CMD-07UD-ZNPlease see detailed description in accesorry section.<strong>NETbox</strong> Double Section cabinets has the same front doorvariations like d:450 or d:600mm<strong>NETbox</strong> Rear Section Module, can be swinging up to 102 degreeopenning angle because of the wall to stop swinging capability,which is the best performance in its segment. If cabinet is used asfree standing cabinet than 180 degree swinging is possible.While cabinet is on wall a straight access could be managed toenclosure in fully swing out position.** Of course if the cabinet is assembled to a column or end ofwall , which the swinging capability has not been stopped by wallor any other stopper, than can swing up to 180 degree.0 -102DOUBLE SECTION OPENING ANGLEwww.lande.com.tr20


19” Netbox <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> Width: 600 mm.Depth: 150 mm.DOUBLE SECTIONCONSTRUCTIONDRAWINGCONSTRUCTIONDRAWINGTOP VIEWISOMETRIC VIEWAh440FRONT VIEW SIDE VIEW REAR VIEWBOTTOM VIEWEXPLODED VIEWwww.lande.com.tr21


19” Netbox <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> Width: 600 mm.Depth: 150 mm.DOUBLE SECTIONCONSTRUCTIONDRAWING0 -102600DOUBLE SECTION OPENING ANGLE1457075150450Max 460 / Std Min 400 / Std 42044,45(1U)145709,5hH451Max 115 / Min 55 / Std 95MAX/STD/MIN EQUIPMENTMOUNTING DISTANCEDIMENSIONS INWIDTH AND HEIGHT<strong>NETbox</strong> <strong>Series</strong> <strong>Wall</strong> <strong>Mounting</strong> 19'' <strong>Cabinets</strong> REAR SECTION MODULE W=600mm D=150mmROOT ProductNumber ***Product DescriptionSize WXDXHmmh size in Uh in mmH mm, overallWidth OverallmmAh <strong>Wall</strong> <strong>Mounting</strong>h mmWidth Rail toRailDepth OverallmmQTY INPACKAGEPACKINGDIMENTIONSWXDXH mmStandard NETWeight of product kgsGross Weight ofProduct kgsLN-WM07U6015-AGLN-WM09U6015-AGLN-WM12U6015-AGLN-WM16U6015-AGLN-WM20U6015-AG<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> Cabinet 7U Rear Section 600x150x423<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> Cabinet 9U Rear Section 600x150x512<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> Cabinet 12U Rear Section 600x150x646<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> Cabinet 16U Rear Section 600x150X824<strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> Cabinet 20U Rear Section 600x150X10017U9U12U16U20U311400533711889423512646824100160060060060060030038952270087819”19”19”19”19”15015015015015011111655x175x420655x175x510655x175x645655x175x625655x175x10108,210,413,31821,38,811,3152025***AG= Anthracite Grey RAL 7016.www.lande.com.tr22


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong>Frequent Used Accesorry Selection ChartFrequent Used Accesorries 19'' <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> w:width mm d:depth mm<strong>NETbox</strong> <strong>Wall</strong> w:600xd:450<strong>NETbox</strong> <strong>Wall</strong> w:600xd:600<strong>NETbox</strong> <strong>Wall</strong> w:600xd:150 integrateddouble section d:450+150 or d:600+150Rack Mount ShelvesLN-RAF-RMO-1U25-CCLN-RAF-RMO-2U35-CCLN-RAF-RMO-1U25-CCLN-RAF-RMO-2U35-CCLN-RAF-RMO-1U25-CCLN-RAF-RMO-2U35-CC**CC is color code: please insert BL for Black and LG for Light Grey on the part numbers while creating orderFrequent Used Accesorries 19'' <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> w:width mm d:depth mm<strong>NETbox</strong> <strong>Wall</strong> w:600xd:450<strong>NETbox</strong><strong>Wall</strong> w:600xd:600<strong>NETbox</strong> <strong>Wall</strong> w:600xd:150 integrateddouble section d:450+150 or d:600+150Sliding Shelves - ***LN-RAF-HRK-D600-CC ***LN-RAF-HRK-D600-CC**CC is color code: please insert BL for Black and LG for Light Grey on the part numbers while creating order*** Can be used once additional set of 19'' rails to be ordered for rear side of the cabinetFrequent Used Accesorries 19'' <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> w:width mm d:depth mm<strong>NETbox</strong> <strong>Wall</strong> w:600xd:450<strong>NETbox</strong><strong>Wall</strong> w:600xd:600<strong>NETbox</strong> <strong>Wall</strong> w:600xd:150 integrateddouble section d:450+150 or d:600+1501 fan Units on/off switchedLN-FAN-ONF-1FWM-CCLN-FAN-ONF-1FWM-CCLN-FAN-ONF-1FWM-CC1 fan Units with Thermostatic control UnitLN-FAN-THM-1FWM-CCLN-FAN-THM-1FWM-CCLN-FAN-THM-1FWM-CC2 fan Units on/off switchedLN-FAN-ONF-2FWM-CCLN-FAN-ONF-2FWM-CCLN-FAN-ONF-2FWM-CC2 fan Units with Thermostatic control UnitLN-FAN-THM-2FWM-CCLN-FAN-THM-2FWM-CCLN-FAN-THM-2FWM-CC**CC is color code: please insert BL for Black and LG for Light Grey on the part numbers while creating orderwww.lande.com.tr23


19” <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong>Frequent Used Accesorry Selection ChartFrequent Used Accesorries 19'' <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> w:width mm d:depth mm<strong>NETbox</strong> <strong>Wall</strong> w:600xd:450<strong>NETbox</strong> <strong>Wall</strong> w:600xd:600<strong>NETbox</strong> <strong>Wall</strong> w:600xd:150 integrateddouble section d:450+150 or d:600+150Horizontal Cable Management Panel 19'' 1U 5 rings LN-KDG-YKD-1UKN-CC LN-KDG-YKD-1UKN-CC LN-KDG-YKD-1UKN-CC**CC is color code: please insert BL for Black and LG for Light Grey on the part numbers while creating orderFrequent Used Accesorries 19'' <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> w:width mm d:depth mm<strong>NETbox</strong> <strong>Wall</strong> w:600xd:450<strong>NETbox</strong> <strong>Wall</strong> w:600xd:600<strong>NETbox</strong> <strong>Wall</strong> w:600xd:150 integrateddouble section d:450+150 or d:600+150Caster Group 2 w/breakes 2 wo/breakes LN-ZMN-TKR-5020-XX LN-ZMN-TKR-5020-XX LN-ZMN-TKR-5020-XXFrequent Used Accesorries 19'' <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> w:width mm d:depth mm<strong>NETbox</strong> <strong>Wall</strong> w:600xd:450<strong>NETbox</strong> <strong>Wall</strong> w:600xd:600<strong>NETbox</strong> <strong>Wall</strong> w:600xd:150 integrateddouble section d:450+150 or d:600+150PDU 6 way Schuko with 1x16A cct breaker LN-PRZ-SGT-1U6P-SC LN-PRZ-SGT-1U6P-SC LN-PRZ-SGT-1U6P-SCFrequent Used Accesorries 19'' <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> w:width mm d:depth mm<strong>NETbox</strong> <strong>Wall</strong> w:600xd:450<strong>NETbox</strong> <strong>Wall</strong> w:600xd:600<strong>NETbox</strong> <strong>Wall</strong> w:600xd:150 integrateddouble section d:450+150 or d:600+150PDU Economic 6 way Schuko on/off switch LN-PRZ-EKO-1U6P-SC LN-PRZ-EKO-1U6P-SC LN-PRZ-EKO-1U6P-SCFrequent Used Accesorries 19'' <strong>NETbox</strong> <strong>Wall</strong> <strong>Mounting</strong> <strong>Cabinets</strong> w:width mm d:depth mm<strong>NETbox</strong> <strong>Wall</strong> w:600xd:450<strong>NETbox</strong> <strong>Wall</strong> w:600xd:600<strong>NETbox</strong> <strong>Wall</strong> w:600xd:150 integrateddouble section d:450+150 or d:600+150<strong>Mounting</strong> Hardware, Fixing M6 Cage nut set of 20 LN-DGR-KFS-M620-XX LN-DGR-KFS-M620-XX LN-DGR-KFS-M620-XXwww.lande.com.tr24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!