<strong>Linear</strong> <strong>Actuators</strong>Electrical Wiring DiagramsAC-actuatorsElectrak 205ActuatorDPDT SwitchRetractOffExtendPotentiometerOutputL1Capacitor*LSR**InputVoltageLSE**L2GroundBrake**** Capacitor required to run the actuator. 115 Vac = 35 µF, p/n 9200-448-002,230 Vac = 10 µF, p/n 9200-448-003.** LSR = end of stroke limit switch in retracted position,LSE = end of stroke limit switch in extended position.*** Electrical brake.The terminal strip is accessed by opening the rearcover of the actuator housing. Connect terminal 8 to L1and terminal 2 to L2 to extend the actuator. Change L1from terminal 8 to 13 to retract the actuator. Releasethe anti coast brake by connecting terminal 1 to L1. Thepotentiometer output is connected to terminals 14, 15 and16.www.thomsonlinear.com41