12.07.2015 Views

Solenoid valves Type EVR 2 → 40 NC/ NO

Solenoid valves Type EVR 2 → 40 NC/ NO

Solenoid valves Type EVR 2 → 40 NC/ NO

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Technical leaflet<strong>Solenoid</strong> <strong>valves</strong> type <strong>EVR</strong> 2 <strong>→</strong> <strong>40</strong> − <strong>NC</strong> / <strong>NO</strong>ContentsPageIntroduction....................................................................................... 4Features........................................................................................... 4Approvals ......................................................................................... 4Technical data ................................................................................... 4-5Ordering ........................................................................................ 6-8Liquid capacity Q o kW, R22/ R134a/R<strong>40</strong>4A/R507. .................................................... 9Liquid capacity Q o kW, R<strong>40</strong>7C ..................................................................... 10Suction vapour capacity Q o kW, R22 .............................................................. 10Suction vapour capacity Q o kW, R134a/R<strong>40</strong>4A/R507. ............................................... 11Suction vapour capacity Q o kW, R<strong>40</strong>7C ............................................................ 12Hot gas capacity Q h kW, R22. ...................................................................... 13Hot gas capacity Q h kW, R134a .................................................................... 14Hot gas capacity Q h kW, R<strong>40</strong>4A/R507 .............................................................. 15Hot gas capacity Q h kW, R<strong>40</strong>7C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Hot gas capacity G h kg/s, R22/R134a. .............................................................. 17Hot gas capacity G h kg/s, R<strong>40</strong>4A/R507/R<strong>40</strong>7C ...................................................... 18Design/ Function ................................................................................. 19Material specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Dimensions and weight, <strong>EVR</strong> (<strong>NC</strong>) 2 <strong>→</strong> 15 and <strong>EVR</strong> 6 -> 15 (<strong>NO</strong>) with fl are connection .............. 21Dimensions and weight, <strong>EVR</strong> (<strong>NC</strong>) 2 <strong>→</strong> 22 and <strong>EVR</strong> 6 -> 22 (<strong>NO</strong>) with solder connection ............. 22Dimensions and weight, <strong>EVR</strong> (<strong>NC</strong>) 25, 32 og <strong>40</strong> with solder connection ............................. 23© Danfoss A/S (AC-AKC / frz, 05 - 2008 DKRCCPDBB0A302-520H1275 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!