12.07.2015 Views

Compact fans for AC and DC [PDF] - ebm-papst

Compact fans for AC and DC [PDF] - ebm-papst

Compact fans for AC and DC [PDF] - ebm-papst

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>AC</strong>maxx / i-maxxTechnical in<strong>for</strong>mationProgress made by <strong>ebm</strong>-<strong>papst</strong>The best example: The <strong>AC</strong>maxx <strong>fans</strong> from <strong>ebm</strong>-<strong>papst</strong>, which, thanks to aningenious yet simple improvement over conventional <strong>AC</strong> <strong>fans</strong>, providesubstantial benefits.The aim in developing the new <strong>AC</strong>maxx series was to raise the technologyst<strong>and</strong>ard of the conventional <strong>AC</strong> fan significantly <strong>and</strong>, in the process, facilitatethe transition to the new technology by retaining the overall mountingdimensions. In short, to ensure the <strong>fans</strong> can be replaced 1:1 withoutany peripheral changes or changes to the voltage situation.<strong>ebm</strong>-<strong>papst</strong> offers two generations of <strong>AC</strong>maxx products that meet differentneeds.<strong>AC</strong> <strong>AC</strong>maxx i-maxxWhat <strong>AC</strong>maxx <strong>and</strong> i-maxx have in common:Energy efficiencyThe drive concept is based on state-of-the-art GreenTech EC technologywith outst<strong>and</strong>ing motor efficiency. Compared to <strong>AC</strong> <strong>fans</strong> of the same size,<strong>AC</strong>maxx energy consumption is up to 77% lower–<strong>for</strong> higher cooling capacity!The energy balance alone means that the products pay <strong>for</strong> themselvesafter only a few months. The savings over the entire service life, especiallyin systems with multiple <strong>fans</strong>, is considerable.Long service lifeThe efficiency of <strong>AC</strong>maxx <strong>and</strong> i-maxx motors is up to 75% higher than thatof conventional <strong>AC</strong> fan variants. This not only saves energy, it also meansless intrinsic heating in the motor. The reduced heating has a direct, positiveeffect on the bearing system, which is why the <strong>fans</strong> have a service lifethat is up to 85% longer! This also lengthens the service <strong>and</strong> maintenanceintervals significantly. The expense of replacement <strong>fans</strong>, <strong>and</strong> even moreexpensive downtimes, are kept to a manageable minimum.[ EUR ]60h40<strong>AC</strong> 4000 N800007000070000200<strong>AC</strong> 4300<strong>AC</strong>i 440060000500004000088% increasein life time375000 12 3Years30000Independent of mains frequency <strong>and</strong> mains voltage2000010000The <strong>AC</strong>maxx <strong>and</strong> i-maxx <strong>fans</strong> are prepared <strong>for</strong> direct connection to all <strong>AC</strong>voltages <strong>and</strong> frequencies. The speed, <strong>and</strong> thus important properties of thefan such as air flow <strong>and</strong> noise, are independent of the power frequency<strong>and</strong> do not change, even within the defined voltage range. Voltage fluctuationsin the power system are automatically compensated <strong>for</strong>.ServiceLife<strong>AC</strong> St<strong>and</strong>ard<strong>AC</strong>maxx126

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!