12.07.2015 Views

Compact fans for AC and DC [PDF] - ebm-papst

Compact fans for AC and DC [PDF] - ebm-papst

Compact fans for AC and DC [PDF] - ebm-papst

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

max. 220 m 3 /h<strong>DC</strong> centrifugal <strong>fans</strong>Series RET 97 TD 97 Ø x 41 mmHighlights:– 3-phase fan drive with high degree of running smoothness.– Very high pressure build-up.– Forward curved impeller.– Available as st<strong>and</strong>ard with PWM control input <strong>and</strong> speed signal.Additional inputs <strong>and</strong> outputs on request.General characteristics:– Impeller of galvanised steel plate.– Fully integrated electronic commutation.– Direction of rotation: CW seen on rotor.– Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet.– Connection via single str<strong>and</strong>s AWG 22, TR 64. Bared <strong>and</strong> tin-plated.– Mass: 430 g.Nominal dataAir flowAir flowNominal voltageVoltage rangeSound power levelSintec sleeve bearingsBall bearingsPower inputNominal speedTemperature rangeService life L 10 (40 °C)<strong>ebm</strong>-<strong>papst</strong> St<strong>and</strong>ardService life L 10 (T max )<strong>ebm</strong>-<strong>papst</strong> St<strong>and</strong>ardLife expectancy L 10 ∆(40 °C) see P. 15CurveSpecialsType m 3 /h CFM V<strong>DC</strong> V<strong>DC</strong> Bel(A) / Watts RPM °C Hours HoursNEWNEWRET 97-25/14/2TDP* 220 129 24 16...36 8,1 72 6 000 -20...+60 80 000 / 50 000 160 000 1RET 97-25/18/2TDP 220 129 48 36...60 8,1 72 6 000 -20...+60 80 000 / 50 000 160 000 1* PreliminarySpeed control range from 800 rpm at 7 % PWM up to nominal speed at > 90 % PWM. St<strong>and</strong>still at 0 % PWM,maximum speed at sensor break.To attain the specified service life, an external capacitor must be wired between the plus <strong>and</strong> minus str<strong>and</strong>s.Please note the wiring suggestion on page.R16Air flowThe air flow <strong>and</strong> noise level of <strong>fans</strong> without externalhousing depends on the installation conditions. The statedair flow <strong>and</strong> noise levels have been measured under thefollowing conditions:Centrifugal fan mounted on a base plate 116 x 116 mm.Cover plate 116 x 116 mm with an air inlet of Ø 80 mm,concentric to the impeller.Air flow310Pa2 mm+106+1800700600500[in H 2O]2,41ø 47,1ø58,3974001,63002000,824,4M4 (4x)10040,5+ 17,95+ 1025 50 75 100 125CFM50 100 150 200m³/h92N GTIPWMAHP

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!