12.07.2015 Views

SPORTident BSF7 control stations Software version 5.25 and higher ...

SPORTident BSF7 control stations Software version 5.25 and higher ...

SPORTident BSF7 control stations Software version 5.25 and higher ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>SPORTident</strong> <strong>BSF7</strong> <strong>control</strong> <strong>stations</strong><strong>Software</strong> <strong>version</strong> <strong>5.25</strong> <strong>and</strong> <strong>higher</strong>Release notesDear customer,Thank you for using our <strong>SPORTident</strong> <strong>BSF7</strong> <strong>control</strong> station. This letter describes features to beconsidered using the system parts.New product featuresThe <strong>SPORTident</strong> station BSx7 is based on a newly developed hardware core. The new designoffers a number of significant improvements <strong>and</strong> new features compared to the older series of<strong>SPORTident</strong> <strong>stations</strong>. The new BSx7 station is still compatible with the already existing<strong>SPORTident</strong> system parts <strong>and</strong> can be used mixed with older equipment.• The BSx7 station is “always on” <strong>and</strong> works in a low power St<strong>and</strong>by mode. There is noneed to switch on the station or to make any special preparations before the unit can beused. Also in st<strong>and</strong>by mode the station is fully qualified to proceed <strong>SPORTident</strong> cards. Themaximal wake up time is 1 sec but can be adjusted by the user. A faster wake up willincrease station’s power consumption. The station is switched from St<strong>and</strong>by mode toActive mode when the first <strong>SPORTident</strong> card is inserted.• Once the station is in Active Mode the reaction time to the insertion of subsequent<strong>SPORTident</strong> cards is very quick. After an adjustable period without a <strong>SPORTident</strong> cardbeing inserted, the station drops back to st<strong>and</strong>by mode. As with earlier <strong>stations</strong>, ActiveMode can also be entered by setting a predefined switch on time using PC software(Competition mode).• The <strong>BSF7</strong> station features with an on-board service display visible from the back side. Thedisplay shows quickly main <strong>stations</strong> settings like real time <strong>and</strong> code number. After a cardhas punched the card number is displayed too.•• From St<strong>and</strong>by Mode the station can also be switched to Servicemode. This is done by switching on the station with the “lilac offstick”. In Service Mode the station’s LCD display offers additionalinformation like station’s origin, battery consumption <strong>and</strong>firmware <strong>version</strong>. Information about station’s battery is given bothby measuring the battery voltage <strong>and</strong> by computing the station’sbattery consumption in relation to the battery performance. ServiceMode is automatically terminated after 10 minutes or earlier if the“off stick” is used.


<strong>SPORTident</strong> <strong>BSF7</strong> <strong>control</strong> <strong>stations</strong>, sw <strong>version</strong> 5.x• It was a special goal to develop a device which best meets the growing requirement toprotect our environment. The <strong>SPORTident</strong> Station BSx7 features with a very low powerconsumption. In typical application cycles a battery will serve for several years. Thisenables the use of a smaller battery. The battery is soldered to the printed circuit board <strong>and</strong>this enables the <strong>SPORTident</strong> organisation to guarantee <strong>and</strong> <strong>control</strong> a fully certified disposalof empty batteries. For the first time an environmentally compatible lithium battery is used.This battery type does neither contain cadmium nor mercury. Other points of importanceare decreased use of plastic material as a result of the smaller volume <strong>and</strong> weight.• The station’s real time clock system is calibrated <strong>and</strong> temperature compensated. This offers<strong>higher</strong> accuracy also at very high <strong>and</strong> very low temperatures 1 . The internal time resolutionis approximately 4 ms.• The station’s backup memory is increased <strong>and</strong> is typically 8 times bigger than that of theBSF6 station.H<strong>and</strong>ling <strong>and</strong> service• The <strong>BSF7</strong> station only needs minimal services. In typical application cycles only the<strong>stations</strong> real time has to be <strong>control</strong>led.• The station’s settings can be changed by using SIMAN 9.8. In the inductive couplingprocess between a <strong>SPORTident</strong> master station <strong>and</strong> a slaved station a coupling stick has tobe used.• To achieve highest synchronism in the <strong>stations</strong> real time clock it is recommended to adjust<strong>stations</strong> real time by using the TimeMaster (coupling stick needed). If SIMAN is usedinstead <strong>stations</strong> time has to be <strong>control</strong>led using the on-board display.• The battery has a capacity of 2000 mAh. This value should not be changed.• The <strong>SPORTident</strong> <strong>stations</strong> 7 <strong>and</strong> 8 feature with an easy firmware upgrade mechanism. The<strong>stations</strong> firmware can be uploaded by the user via simple inductive coupling. This featurekeeps the station up to date <strong>and</strong> enables the implementation of additional functionality. Toupgrade the firmware a master station BSM7 must be used. Information about firmware<strong>version</strong>s <strong>and</strong> features are available on the <strong>SPORTident</strong> website.Limitations• In the station firmware the mode “clear without start number” is not supported any more.• SIMAN9.8 indicates a wrong power consumption value for the station. Please use theinformation shown at the <strong>stations</strong> display (service mode).• 1 The temperature compensation for the <strong>stations</strong> real time clock does not have fullperformance in SW <strong>5.25</strong>. Improvements will come with later firmware <strong>version</strong>s.• After a change of the <strong>stations</strong> settings the first active mode is terminated after 10 minutes.Make a test punch after a station is reprogrammed <strong>and</strong> turn it off with the Off-stick.• Inductive coupling in the configuration SIMAN9.8, master station BSM3/4/6 <strong>and</strong> the <strong>BSF7</strong>is sensitive regarding the coupling distance. In case of difficulties modify the couplingconditions.Good luck with <strong>SPORTident</strong> !AES GmbHArnstadt, 2004-05-26- 2 -www.sportident.comsupport@sportident.comAES GmbH, Markt 14D-99310 Arnstadt, Germanyphone: +49-3628-78300fax: +49-3628-78303

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!