ICu<br />
ACu<br />
mCu<br />
AR<br />
is the mean copper path length<br />
is the effective copper cross section, calculated with a copper filling factor of 50 %<br />
is the copper mass. mCu (g) = lCu (cm) x ACu (cm²) x δCu (g/cm³).<br />
δCu = 8,92 g/cm³<br />
is the so-called resistance factor. AR = ρCu * lCu/ACu. The ratio AL/AR is the dc time<br />
constant. The dc time constant is the time to reach 63,2 % of the final value after<br />
switching on a dc current.<br />
Table 6: Stacking factors and specific weight, correction factors for core mass mFe<br />
Stacking factors for core packages Correction factors for core mass<br />
Strip thickness (mm) 0,35 0,2 0,1 0,35 0,2 0,1<br />
MUMETALL ® , VACOPERM ® 100 94 % 94 % 92 % 1,05 1,05 1,03<br />
PERMENORM ® 5000 H2 94 % 94 % 92 % 1,00 1,00 0,98<br />
TRAFOPERM ® N2 92 % 92 % 90 % 0,91 0,91 0,89<br />
S<strong>EK</strong>ELS <strong>GmbH</strong>, Dieselstr. 6, 61239 Ober-Mörlen; www.sekels.com Page 6 of 8