ICu<br />

ACu<br />

mCu<br />

AR<br />

is the mean copper path length<br />

is the effective copper cross section, calculated with a copper filling factor of 50 %<br />

is the copper mass. mCu (g) = lCu (cm) x ACu (cm²) x δCu (g/cm³).<br />

δCu = 8,92 g/cm³<br />

is the so-called resistance factor. AR = ρCu * lCu/ACu. The ratio AL/AR is the dc time<br />

constant. The dc time constant is the time to reach 63,2 % of the final value after<br />

switching on a dc current.<br />

Table 6: Stacking factors and specific weight, correction factors for core mass mFe<br />

Stacking factors for core packages Correction factors for core mass<br />

Strip thickness (mm) 0,35 0,2 0,1 0,35 0,2 0,1<br />

MUMETALL ® , VACOPERM ® 100 94 % 94 % 92 % 1,05 1,05 1,03<br />

PERMENORM ® 5000 H2 94 % 94 % 92 % 1,00 1,00 0,98<br />

TRAFOPERM ® N2 92 % 92 % 90 % 0,91 0,91 0,89<br />

S<strong>EK</strong>ELS <strong>GmbH</strong>, Dieselstr. 6, 61239 Ober-Mörlen; www.sekels.com Page 6 of 8