12.07.2015 Views

02/2013 - Building & Construction Authority

02/2013 - Building & Construction Authority

02/2013 - Building & Construction Authority

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

GREEN HIGHLIGHTSCredit Suisse Regional Data CentreBCA-IDA GREEN MARK FOR EXISTING DATACENTRESData centres are heavy users of energy and are expected toincrease their energy footprint further with the rapid growth ofcloud-based services, online media and transactions. Accordingto the Infocomm Development <strong>Authority</strong> (IDA), Singapore’s 10largest data centres are estimated to consume energy equivalentto 130,000 households. The Singapore commercial data centrecapacity is projected to increase by 50% from 2010 to 2015 witha corresponding increase in energy consumption.The BCA-IDA Green Mark for Existing Data Centres is a jointcollaboration scheme between BCA and IDA to benchmark theperformance and rate the greenness of data centres. Using a pointscoring system, it assesses data centres on energy efficiency, waterefficiency, sustainable construction and management, indoorenvironmental quality and other green features. The certificationis valid for three years after which the project has to apply for recertificationif it wants to maintain the Green Mark logo.• Credit Suisse Data CentreAwarded the new BCA Green Mark Platinum Rating forExisting Data Centres, this data centre was constructed asa five-storey purpose-built light industrial building. It iscapable of meeting the data centre growth projections forthe next 25 years based on reasonable growth rates anddesigned to be modular in nature to minimise initialconstruction cost.The certification recognised its use of info-communicationequipment with Energy Star rating and energy metering toprovide total facility power and energy usage and totalequipment power to determine the PUE energy efficiencynumber. It also uses bi-level lightings, with a lighting sensorcontrol for each row of server racks, and provides a facilityfor the collection and storage of recyclable wastes such asplastic, metal and paper waste.Equinix SG 2 Data Centre Hall• Equinix SG 2 Data CentreThis co-location data centre service provider received theBCA Green Mark Gold Plus Rating for Existing Data Centres aswell as the SS564 certification: Singapore Standard for GreenData Centres – Energy and environmental managementsystems. It occupies two levels, each with its own facilitysystem to provide power and cooling.It is also equipped with bi-level lightings with lighting sensorcontrol at each row of server racks and energy metering forenergy efficiency. In addition, it uses NEWater for its coolingsystem and other non-potable water requirements.• Singapore Tourism Board Data CentreThis enterprise data centre adopted some of the best practicesfor data centres in energy efficiency management. It achieved90% in power train efficiency, defined as the efficiency of theelectrical power supply system in providing the required levelof redundancy while maintaining high load factors. It alsoemploys energy metering to monitor energy efficiency levels.For its efforts, it was awarded the BCA Green Mark GoldRating for Existing Data Centres as well as the SS564certification: Singapore Standard for Green Data Centres –Energy and environmental management systems.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!