12.07.2015 Views

DME 3000-2 Distance measuring devices 105 138 54 s Excellent ...

DME 3000-2 Distance measuring devices 105 138 54 s Excellent ...

DME 3000-2 Distance measuring devices 105 138 54 s Excellent ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>DME</strong> <strong>3000</strong>-2 <strong>Distance</strong> <strong>measuring</strong> <strong>devices</strong>Measurement rangeup to 10 m<strong>Distance</strong> <strong>measuring</strong> <strong>devices</strong>Dimensional drawing235 12■ <strong>Excellent</strong> measurement accuracy andreproducibility thanks to time-of-flightmeasurement■ Simple adjustment using visible redlight■ Easy handling due to programmableparameters-- 2 switching outputs-- pre-failure signalling output-- plausibility control■ RS 422 serial interface andSSI interface■ Profibus■ Gateway to Interbus, DeviceNet<strong>54</strong>28.57812856935 59<strong>138</strong>127.53M4669.5 4076 9M625.2946<strong>105</strong>45Adjustments possible<strong>DME</strong> <strong>3000</strong>-211 <strong>DME</strong> <strong>3000</strong>-232<strong>DME</strong> <strong>3000</strong>-212 <strong>DME</strong> <strong>3000</strong>-211P4123456Centre of optical axisM6 threaded mounting hole, 10 mm deepM4 threaded mounting hole, 14 mm deep(this side only)8-digit alphanumeric indicatorProgramming switchesM4 threaded mounting hole, 6 mm deep45Connection types<strong>DME</strong> <strong>3000</strong>-211<strong>DME</strong> <strong>3000</strong>-212<strong>DME</strong> <strong>3000</strong>-232<strong>DME</strong> <strong>3000</strong>-211PCC VLaser class 2, 3 BAccessoriespageCable receptacles 496Mounting brackets 510Link mountings 510Special accessories 556Dust coversCooling platesRemote positioning tubes12-pin, M 16 4-pin, M 12 5-pin, M 12 5-pin, M 12whtbrngrngrapnkredblkgra/pnkred/blubluABCDEFGHIKLMTX+Q 1RX+NCQ SQ PL+RX—NCTX—Q 2MSend data( SSI: data + )Receive data( SSI: Clock + )Receive data( SSI: Clock – )Send data( SSI: data – )A1 L+234Q 2MQ 1B5 Vcable AMcable BShieldAAdapter not incuded in deliveryBC1 NC2cable A3NC4cable B5Shield456 SENSICK CATALOGUE


<strong>DME</strong> <strong>3000</strong>-2Technical Data <strong>DME</strong> <strong>3000</strong>- 211 212 232 211PMeasurement range100...8,000 mm100...10,000 mmLight spot diameter 5 mm (measurement distance 8 m)Resolution0.125 mmLight source 2) , light typeDiode laser, red lightLaser category 2 (IEC 825-1/EN 60825-1)Laser category 3 B (IEC 825-1/EN 60825-1)Service life (at 25 °C)MTTF 50,000 hNIR blocking filterSupply voltage V S 18...30 V DC 3)Ripple < 5 V4) SSPower consumption ≤ 6 W 5)Switching outputsPNP/NPNQ 1 , Q 2 , Q P , Q SHIGH = V S – < 2 V/LOW = < 2 VOutput current I A max.100 mAQ 1 and Q 2 switching outputs Reversible Q/Q –Switching limit/switching hysteresis AdjustableQ P plausibility outputHIGH: measurement correct/LOW: measurement errorQ S service outputHIGH: OK/ LOW: pre-failure signallingoutputConnection typeVDE protection class 6)Circuit protection 7)PlugVA, B, CEnclosure rating IP 65Ambient temperature T A Operation – 10 °C...+45 °CStorage – 25 °C...+75 °CWeightApprox. 980 gInterfacesSSI: GRIS/BINARY adjust., 24 or 25 bitsSerial interfaceRS 422: 4.8/9.6/19.2/38.4 kBaudProfibusMax. 12 MBaudTemperature driftTypical 0.4 mm/K(compensation on request)Measured value outputSSI/Profibus21 msRS 422, 38.4 kBaud21 msInitialisation period6 s1) Relative to front edge of object2) Average service life 50,000 hat T A = + 25 °C3) Limit values4) May not exceed or fall short ofV S tolerances5) Without load6) Reference voltage 50 V DC7) A = V S connections reverse-polarityprotectedB = Output Q short-circuit protectedC = Interference pulse suppression18) Environmental conditions constant,min. switching period 30 min.19) 23 °C air temp, 977 hPA,min. switching period 30 min.10) Re-calibration recommended after25,000 h.Reproducibility and accuracy as a function of measurement distance<strong>DME</strong> <strong>3000</strong>-21.. 232 21.. 232 21.. 232Measurement distance 1 m2 m 4 mReproducibility 8)White, 90 % remissionGrey, 18 % remissionBlack, 6 % remissionAccuracy 9)10)White, 90 % remissionGrey, 18 % remissionBlack, 6 % remission1 mm2 mm0.5 mm1 mm2 mm5 mm1 mm2.5 mm5 mm25 mm2 mm5 mm5 mm 2 mm 25 mm 8 mm – 25 mm±5mm ±5mm ±5mm ±5mm ±10mm ±5mm±5mm ±5mm ±10mm ±5mm ±30mm ±10mm±10mm ±5mm ±20mm ±10mm – ±10mm21.. 232 21..6 m 8 m10 mm––5 mm 25 mm25 mm –– –23210 m20 mm––±20mm ±5mm ±30mm ±20mm– ±25mm – –– – – –Order informationType<strong>DME</strong> <strong>3000</strong>-211<strong>DME</strong> <strong>3000</strong>-212<strong>DME</strong> <strong>3000</strong>-232<strong>DME</strong> <strong>3000</strong>-211PPart no.1 013 7821 015 9061 015 7941 018 064SENSICK CATALOGUE457

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!