12.07.2015 Views

SUCOFORM The handformable alternative to SEMI-RIGID - Nkt-rf.ru

SUCOFORM The handformable alternative to SEMI-RIGID - Nkt-rf.ru

SUCOFORM The handformable alternative to SEMI-RIGID - Nkt-rf.ru

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>SUCOFORM</strong><strong>The</strong> <strong>handformable</strong> <strong>alternative</strong> <strong>to</strong> <strong>SEMI</strong>-<strong>RIGID</strong>ContentProduct description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Features and benefits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Overview of common <strong>SUCOFORM</strong> cable types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Product specification of<strong>SUCOFORM</strong>_47_CU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46<strong>SUCOFORM</strong>_86 / _86_PE / _86_FEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<strong>SUCOFORM</strong>_141 / _141_PE / _141_FEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50<strong>SUCOFORM</strong>_141_CU / _141_CU_PE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52<strong>SUCOFORM</strong>_141_CU_FEP / _141_CU_LSFH-01. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54<strong>SUCOFORM</strong>_250-01 / _250-01_FEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Further available <strong>SUCOFORM</strong> products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58<strong>SUCOFORM</strong>Suitable connec<strong>to</strong>rs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59HUBER+SUHNER microwave cables and assemblies 43


44 HUBER+SUHNER microwave Microwave Cables cables and and Assembliesassemblies


<strong>SUCOFORM</strong><strong>The</strong> <strong>handformable</strong> <strong>alternative</strong> <strong>to</strong> <strong>SEMI</strong>-<strong>RIGID</strong>Product description<strong>SUCOFORM</strong> microwave coaxial cables offer distinctmechanical advantages over semi-rigid cables. <strong>The</strong>yare based on the same design as the standard PTFEinsulatedsemi-rigid cables, but have a tin-soakedcopper braid for the outer conduc<strong>to</strong>r, giving them outstandinghand-formability. <strong>The</strong>se cables combine theexcellent characteristics of semi-rigid cables with thoseof flexible coaxial cables.Thanks <strong>to</strong> their small bending radii, they allow spacesavingrouting and packaging.Features and benefits<strong>SUCOFORM</strong>• Excellent properties: low loss, high screening effectiveness, high operating frequency, high temperature range• Due <strong>to</strong> the high phase stability over every production <strong>ru</strong>n, <strong>SUCOFORM</strong> is especially suitable for delay lines• Good flexibility: easy hand forming without <strong>to</strong>oling; fits in<strong>to</strong> the smallest systems• Comprehensive connec<strong>to</strong>r range; use of standard semi-rigid connec<strong>to</strong>rs• Quick and easy assembly• Available in long lengths and various versionsHUBER+SUHNERcable typeOperatingfrequency(GHz)Temperature rangeminimum(°C)maximum(°C)Outerdia. (mm)Nominal attenuation18 GHz,25°C (dB/m)Bending radiistatic(mm)repeat.(mm)Moreinformationsee page<strong>SUCOFORM</strong>_47_CU 40 –65 +165 1.20 5.4 3.18 – 46<strong>SUCOFORM</strong>_86 40 –65 +165 2.10 3.4 6 20 48<strong>SUCOFORM</strong>_141 33 –65 +165 3.58 2.2 8 40 50<strong>SUCOFORM</strong>_141_CU 33 –65 +165 3.58 2.2 8 40 52<strong>SUCOFORM</strong>_250-01 18 –65 +165 6.35 1.4 30 120 56HUBER+SUHNER microwave cables and assemblies 45


<strong>SUCOFORM</strong>_47_CU / _47_CU_LSFHCable design1 2 3Fig. 1: <strong>SUCOFORM</strong>_47_CU1 2 3Fig. 2: <strong>SUCOFORM</strong>_47_CU_LSFHDescriptionDiameter1. Centre conduc<strong>to</strong>r Solid silver-plated copper wire 0.31 mm2. Dielectric Solid PTFE 0.94 mm3. Outer conduc<strong>to</strong>r Tin soaked copper braid 1.20 mmElectrical cable dataImpedance50 OhmOperating frequency40 GHzCapacitance95 pF/mVelocity of propagation 71 %Time delay4.7 ns/mNom. attenuation* coefficient a 1.117 coefficient b 0.03891Max. attenuation* coefficient a 1.2287 coefficient b 0.0438Max. operating voltage1.0 kVrmsMin. screening effectiveness up <strong>to</strong> 18 GHz100 dB*Attenuation calculation(dB/m)General cable data<strong>SUCOFORM</strong>_47_CU<strong>SUCOFORM</strong>_47_CU_LSFHItem number 23033515 23035506Additional jacket — LSFH (Low Smoke, Free of Halogen)Colour — blackDiameter 1.20 mm 1.70 mmWeight 0.6 kg/100 m 0.75 kg/100 mTemperature range – 65 ... + 165 °C – 40 ... + 85 °CFlammability, passed — —Min. bending radius, static 3.18 mm 3.18 mmMin. bending radius, repeated — —Suitable connec<strong>to</strong>rs, cable group Y2 Y2Drawing see Fig. 1 see Fig. 2Suitable connec<strong>to</strong>rs see cable group Y2 (please refer <strong>to</strong> page 59)46 HUBER+SUHNER microwave cables and assemblies


<strong>SUCOFORM</strong>_47_CU / _47_CU_LSFHCable attenuationNominal values @ +25 °C ambient temperature8.06.0Attenuation (dB/m)4.02.0<strong>SUCOFORM</strong>_47_CU<strong>SUCOFORM</strong>_47_CU_LSFH<strong>SUCOFORM</strong>0.00 5 10 15 20 25 30 35 40Frequency (GHz)Power handlingMaximum values @ +40 °C ambient temperature and sea level4030C.W.Power (Watts)20<strong>SUCOFORM</strong>_47_CU100<strong>SUCOFORM</strong>_47_CU_LSFH0 5 10 15 20 25 30 35 40Frequency (GHz)HUBER+SUHNER microwave cables and assemblies 47


<strong>SUCOFORM</strong>_86 / _86_PE / _86_FEPCable design1 2 3Fig. 1: <strong>SUCOFORM</strong>_861 2 3Fig. 2: <strong>SUCOFORM</strong>_86_PE / _86_FEPDescriptionDiameter1. Centre conduc<strong>to</strong>r Solid silver-plated copper clad-steel wire 0.53 mm2. Dielectric Solid PTFE 1.65 mm3. Outer conduc<strong>to</strong>r Tin soaked copper braid 2.10 mmElectrical cable dataImpedance50 OhmOperating frequency40 GHzCapacitance95 pF/mVelocity of propagation 71 %Time delay4.7 ns/mNom. attenuation* coefficient a 0.6283 coefficient b 0.0400Max. attenuation* coefficient a 0.6912 coefficient b 0.0440Max. operating voltage1.5 kVrmsMin. screening effectiveness up <strong>to</strong> 18 GHz100 dB*Attenuation calculation(dB/m)General cable data<strong>SUCOFORM</strong>_86 <strong>SUCOFORM</strong>_86_PE <strong>SUCOFORM</strong>_86_FEPItem number 22511613 22511631 22511942Additional jacket — PE FEPColour — red redDiameter 2.10 mm 3.20 mm 2.50 mmWeight 1.5 kg/100 m 1.7 kg/100 m 1.8 kg/100 mTemperature range – 65 ... + 165 °C – 40 ... + 85 °C – 65 ... + 165 °CFlammability, passed IEC 60332-1,UL 1581-§1080 (VW-1)48 HUBER+SUHNER microwave cables and assemblies— IEC 60332-1,UL 1581-§1080 (VW-1)Min. bending radius, static 6 mm 6 mm 6 mmMin. bending radius, repeated 20 mm 20 mm 20 mmSuitable connec<strong>to</strong>rs, cable group Y11 Y11 Y11Drawing see Fig. 1 see Fig. 2 see Fig. 2Suitable connec<strong>to</strong>rs see cable group Y11 (please refer <strong>to</strong> page 59 ff)


<strong>SUCOFORM</strong>_141 / _141_PE / 141_FEPCable design1 2 3Fig. 1: <strong>SUCOFORM</strong>_1411 2 3Fig. 2: <strong>SUCOFORM</strong>_141_PE / _141_FEPDescriptionDiameter1. Centre conduc<strong>to</strong>r Solid silver-plated copper clad-steel wire 0.95 mm2. Dielectric Solid PTFE 2.95 mm3. Outer conduc<strong>to</strong>r Tin soaked copper braid 3.58 mmElectrical cable dataImpedance50 OhmOperating frequency33 GHzCapacitance92 pF/mVelocity of propagation 71 %Time delay4.7 ns/mNom. attenuation* coefficient a 0.3631 coefficient b 0.0377Max. attenuation* coefficient a 0.3995 coefficient b 0.0415Max. operating voltage1.9 kVrmsMin. screening effectiveness up <strong>to</strong> 18 GHz100 dB*Attenuation calculation(dB/m)General cable data<strong>SUCOFORM</strong>_141 <strong>SUCOFORM</strong>_141_PE <strong>SUCOFORM</strong>_141_FEPItem number 22511925 22511632 22511944Additional jacket — PE FEPColour — red redDiameter 3.58 mm 4.60 mm 4.10 mmWeight 3.8 kg/100 m 4.7 kg/100 m 4.7 kg/100 mTemperature range – 65 ... + 165 °C – 40 ... + 85 °C – 65 ... + 165 °CFlammability, passed IEC 60332-1,UL 1581-§1080 (VW-1)— IEC 60332-1,UL 1581-§1080 (VW-1)Min. bending radius, static 8 mm 8 mm 8 mmMin. bending radius, repeated 40 mm 40 mm 40 mmSuitable connec<strong>to</strong>rs, cable group Y12 Y12 Y12Drawing see Fig. 1 see Fig. 2 see Fig. 2Suitable connec<strong>to</strong>rs see cable group Y12 (please refer <strong>to</strong> page 61 ff)50 HUBER+SUHNER microwave cables and assemblies


<strong>SUCOFORM</strong>_141 / _141_PE / _141_FEPCable attenuationNominal values @ +25 °C ambient temperature3.53.02.5Attenuation (dB/m)2.01.51.00.5<strong>SUCOFORM</strong>_141<strong>SUCOFORM</strong>_141_PE<strong>SUCOFORM</strong>_141_FEP<strong>SUCOFORM</strong>0.00 3 6 9 12 15 18 21 24 27 30 33Frequency (GHz)Power HandlingMaximum values @ +40 °C ambient temperature and sea level800600C.W.Power (Watts)400<strong>SUCOFORM</strong>_141_FEP<strong>SUCOFORM</strong>_141200<strong>SUCOFORM</strong>_141_PE00 3 6 9 12 15 18 21 24 27 30 33Frequency (GHz)HUBER+SUHNER microwave cables and assemblies 51


Atividades produtivasO pe<strong>rf</strong>il da posse de escravos verificada reflete as atividades econômicasdesempenhadas pelos araxaenses. Dessa forma, longe de se destacar por grandes plantéis, aposse de cativos em Araxá foi f<strong>ru</strong><strong>to</strong> da produção de subsistência desenvolvida que teve, comonão poderia ser diferente, importante papel na economia local, sendo responsável pelaabsorção de cativos (principalmente em pequenos plantéis), empregados quer em atividadesde au<strong>to</strong>-subsistência, quer em propriedades com capacidade de produzir excedentes parasuprir o núcleo urbano da própria localidade ou outros mais distantes.A lista nominativa de 1831-32 e o recenseamen<strong>to</strong> de 1873 (Tabela 7) evidenciam paraAraxá o grande contingente populacional ligado a atividades dos se<strong>to</strong>res de agricultura emanufatura <strong>ru</strong>ral e artesana<strong>to</strong>. Pouco mais de 40% dos indivíduos livres com ocupaçãodescrita em 1831-1832 foram declarados lavradores; apenas 15 pessoas (1,5%) apareceramem atividades ligadas ao ramo da pecuária, embora, como apontado anteriormente, a pecuáriatenha se firmado como a principal atividade econômica realizada. Tal constatação levou-nosa acreditar que, em geral, cultura e criação deveriam caminhar juntas. Algumas décadasdepois, em 1873, o percentual de lavradores registrado no censo foi de 46,3%; eram mais de3300 pessoas livres mantendo a ocupação predominante em Araxá desde o início dopovoamen<strong>to</strong> do seu território.Mostraram-se importantes também, no <strong>to</strong>tal de pessoas livres cujas ocupações foramidentificadas, as atividades ligadas ao artesana<strong>to</strong>. Fiadeiras, tecedeiras e rendeiras eram maisde 250 (quase 25%) em 1831-1832, chegando a quase 1000 em 1873, embora nesse anorespondessem por 13,4% da população livre com ocupação especificada no censo,representando, dentro do se<strong>to</strong>r artesana<strong>to</strong>, um percentual menor apenas que as costureiras,14,7%. Sendo essas atividades tipicamente femininas, observamos a importante participaçãodas mulheres nas atividades produtivas araxaenses.Além desses 2 se<strong>to</strong>res principais, encontramos na Araxá de 1831-32 e 1873importante participação na população dos jornaleiros, assalariados sem profissão definida,que provavelmente não conseguiam prover sua subsistência através de atividadesindependentes, seja no campo ou na cidade.Apesar de empregarem reduzida parcela dos araxaenses, as atividades diretamentevinculadas à vida urbana eram diversificadas: pessoas relacionadas ao clero (necessárias parao funcionamen<strong>to</strong> da localidade enquan<strong>to</strong> paróquia e presentes desde a década de 1790,quando foi nomeado o primeiro vigário e const<strong>ru</strong>ída a primeira igreja Matriz de SãoDomingos), aquelas empregadas na magistratura, como juizes e oficiais de justiça, e osprofissionais liberais (ligados ao ramo de advocacia, medicina e afins, ensino e até mesmomúsicos).Ocupadas no se<strong>to</strong>r de comércio foram recenseadas 63 pessoas (6,1%) em 1831-32 eapenas 0,7% dos araxaenses em 1873. Pouco sabemos de específico sobre o comércioaraxaense até 1830, mas encontramos nas listas de contribuintes que pagavam pela licença deseus negócios, uma relação de 21 indivíduos ligados a alguma atividade comercial no ano de1834 (cf. Lista de um relatório para correição. 20/03/1834 – Arquivo FCCB). Mais de meioséculo depois, em 1895, os registros de contribuintes indicavam a existência em Araxá decerca de 40 estabelecimen<strong>to</strong>s comerciais de gêneros do país, fazendas, ferragens, secos emolhados, armarinhos “e <strong>to</strong>dos os demais gêneros”, além de 2 farmácias, 2 botequins, 2“mascates turcos”, 1 padaria, 1 bilhar e 1 tipografia (cf. Lançamen<strong>to</strong> do impos<strong>to</strong> de Industriase Profissões do Município do Araxá no ano de 1895 – Arquivo FCCB).10


<strong>SUCOFORM</strong>_141_CU / _141_CU_PECable attenuationNominal values @ +25 °C ambient temperature3.53.0Attenuation (dB/m)2.52.01.51.00.5<strong>SUCOFORM</strong>_141_CU<strong>SUCOFORM</strong>_141_CU_PE<strong>SUCOFORM</strong>0.00 3 6 9 12 15 18 21 24 27 30 33Frequency (GHz)Power HandlingMaximum values @ +40 °C ambient temperature and sea level600500C.W.Power (Watts)400300200<strong>SUCOFORM</strong>_141_CU100<strong>SUCOFORM</strong>_141_CU_PE00 3 6 9 12 15 18 21 24 27 30 33Frequency (GHz)HUBER+SUHNER microwave cables and assemblies 53


<strong>SUCOFORM</strong>_141_CU_FEP / _141_CU_LSFH-01Cable design1 2 3Fig. 2: <strong>SUCOFORM</strong>_141_CU_FEP1 2 3Fig. 2: <strong>SUCOFORM</strong>_141_CU_LSFH-01DescriptionDiameter1. Centre conduc<strong>to</strong>r Solid silver-plated copper wire 0.95 mm2. Dielectric Solid PTFE 2.95 mm3. Outer conduc<strong>to</strong>r Tin soaked copper braid 3.58 mmElectrical cable dataImpedance50 OhmOperating frequency33 GHzCapacitance92 pF/mVelocity of propagation 71 %Time delay4.7 ns/mNom. attenuation* coefficient a 0.3631 coefficient b 0.0377Max. attenuation* coefficient a 0.3995 coefficient b 0.0415Max. operating voltage1.9 kVrmsMin. screening effectiveness up <strong>to</strong> 18 GHz100 dB*Attenuation calculation(dB/m)General cable data<strong>SUCOFORM</strong>_141_CU_FEPItem number 22512256 84003502<strong>SUCOFORM</strong>_141_CU_LSFH-01Additional jacket FEP LSFH (Low Smoke, Free of Halogen)Colour red orangeDiameter 4.10 mm 4.60 mmWeight 4.7 kg/100m 5.5 kg/100mTemperature range – 65 ... + 165 °C – 40 ... + 85 °CFlammability, passed IEC 60332-1,UL 1581-§1080 (VW-1)IEC 60332-2UL 1581-§ 1100Min. bending radius, static 8 mm 8 mmMin. bending radius, repeated 40 mm 40 mmSuitable connec<strong>to</strong>rs, cable group Y12 Y12Drawing see Fig. 1 see Fig. 2Suitable connec<strong>to</strong>rs see cable group Y12 (please refer <strong>to</strong> page 61 ff)54 HUBER+SUHNER microwave cables and assemblies


<strong>SUCOFORM</strong>_141_CU_FEP / _141_CU_LSFH-01Cable attenuationNominal values @ +25 °C ambient temperature3.53.0Attenuation (dB/m)2.52.01.51.00.5<strong>SUCOFORM</strong>_141_CU_FEP<strong>SUCOFORM</strong>_141_CU_LSFH-01<strong>SUCOFORM</strong>0.00 3 6 9 12 15 18 21 24 27 30 33Frequency (GHz)Power HandlingMaximum values @ +40 °C ambient temperature and sea level800600C.W.Power (Watts)400<strong>SUCOFORM</strong>_141_CU_FEP200<strong>SUCOFORM</strong>_141_CU_LSFH-0100 3 6 9 12 15 18 21 24 27 30 33Frequency (GHz)HUBER+SUHNER microwave cables and assemblies 55


<strong>SUCOFORM</strong>_250-01 / _250-01_FEPCable design1 2 3Fig. 1: <strong>SUCOFORM</strong>_250-011 2 3Fig. 2: <strong>SUCOFORM</strong>_250-01_FEPDescriptionDiameter1. Centre conduc<strong>to</strong>r Solid silver-plated copper wire 1.67 mm2. Dielectric Solid PTFE 5.24 mm3. Outer conduc<strong>to</strong>r Tin soaked copper braid 6.35 mmElectrical cable dataImpedance50 OhmOperating frequency18 GHzCapacitance95 pF/mVelocity of Propagation 71 %Time Delay4.7 ns/mNom. attenuation* coefficient a 0.2100 coefficient b 0.0310Max. attenuation* coefficient a 0.2310 coefficient b 0.0340Max. operating voltage3.5 kVrmsMin. screening effectiveness up <strong>to</strong> 18 GHz100 dB*Attenuation calculation(dB/m)General cable data<strong>SUCOFORM</strong>_250-01Item number 84007938 84007941Additional jacket — FEPColour — redDiameter 6.35 mm 6.80 mm<strong>SUCOFORM</strong>_250-01_FEPWeight 13 kg/100 m 14 kg/100 mTemperature range – 65 ... + 165 °C – 65 ... + 165 °CFlammability, passed IEC 60332-1,UL 1581-§1080 (VW-1)Min. bending radius, static 30 mm 30 mmMin. bending radius, repeated 120 mm 120 mmSuitable connec<strong>to</strong>rs, cable group Y7 Y7Drawing see Fig. 1 see Fig. 2Suitable connec<strong>to</strong>rs see cable group Y7 (please refer <strong>to</strong> page 62)IEC 60332-1,UL 1581-§1080 (VW-1)56 HUBER+SUHNER microwave cables and assemblies


<strong>SUCOFORM</strong> 250-01 / _250-01_FEPCable attenuationNominal values @ +25 °C ambient temperature1.51.2Attenuation (dB/m)0.90.60.3<strong>SUCOFORM</strong>_250-01<strong>SUCOFORM</strong>_250-01_FEP<strong>SUCOFORM</strong>0.00 2 4 6 8 10 12 14 16 18Frequency (GHz)Power handlingMaximum values @ +40 °C ambient temperature and sea level15001200C.W.Power (Watts)900600<strong>SUCOFORM</strong>_250-01<strong>SUCOFORM</strong>_250-01_FEP30000 2 4 6 8 10 12 14 16 18Frequency (GHz)HUBER+SUHNER microwave cables and assemblies 57


<strong>SUCOFORM</strong>Further available <strong>SUCOFORM</strong> products75 OhmHUBER+SUHNERcable typeItem no.Centreconduc<strong>to</strong>rOuterconduc<strong>to</strong>rJacketmaterialOuter diameter(mm)Nom. attenuationdB/m @ 1 GHz<strong>SUCOFORM</strong>_86_75 22511720 StCuAg CuSn n/a 2.10 0.8<strong>SUCOFORM</strong>_86_75_FEP 22511970 StCuAg CuSn FEP 2.50 0.8<strong>SUCOFORM</strong>_141_75 22511721 StCuAg CuSn n/a 3.58 0.5<strong>SUCOFORM</strong>_141_75_FEP 22512290 StCuAg CuSn FEP 4.10 0.5Other impedancesHUBER+SUHNERcable typeItem no.Impedance(Ohm)Centreconduc<strong>to</strong>rOuterconduc<strong>to</strong>rJacketmaterialOuterdiameter(mm)Nom. attenuationdB/m@ 1 GHz<strong>SUCOFORM</strong>_141_35 22512104 35 CuAg CuSn n/a 3.58 0.5<strong>SUCOFORM</strong>_141_35 FEP 22512291 35 CuAg CuSn FEP 4.10 0.5<strong>SUCOFORM</strong>_141_60 22512161 60 StCuAg CuSn n/a 3.58 0.4<strong>SUCOFORM</strong>_141_60 FEP 22512288 60 StCuAg CuSn FEP 4.10 0.4<strong>SUCOFORM</strong>_141_100 22512081 100 StCuAg CuSn n/a 3.58 0.6<strong>SUCOFORM</strong>_141_100 FEP 22512289 100 StCuAg CuSn FEP 4.10 0.6CuAgSilver plated copperPTFEPolytetrafluothyleneStCuAGSilver plated copper clad steelLSFHLow Smoke Free of Halogen polyethyleneCuSnTin soaked copper braidFEPFluoroethylenepropylene copolymerPEPolyethylene58 HUBER+SUHNER microwave cables and assemblies


<strong>SUCOFORM</strong>A wide range of standard connec<strong>to</strong>rs is available for <strong>SUCOFORM</strong> microwave cables. In addition,HUBER+SUHNER offers a fast delivery service for RF tested ready-<strong>to</strong>-use cable assemblies.Suitable connec<strong>to</strong>rsHUBER+SUHNERcable type<strong>SUCOFORM</strong>_47_CUCable group Y2Series, patternHUBER+SUHNERconnec<strong>to</strong>r typeItem no.Operatingfrequency(GHz)MCXStraight cable plug 11_MCX-50-1-14/111_NE 23032081 6Right angle cable plug 16_MCX-50-1-12/111_NE 23024694 6Right angle cable plug 16_MCX-50-1-11/111_NH 23032063 6MMCXStraight cable plug 11_MMCX-50-1-3/111_OE 22648893 6Right angle cable plug 16_MMCX-50-1-4/111_OH 23003641 6Right angle cable plug 16_MMCX-50-1-4/111_OE 22649182 6SKStraight cable plug 11_SK-50-1-2/119_NE 84013232 40<strong>SUCOFORM</strong>SMAStraight cable plug 11_SMA-50-1-53/119_NH 23013327 18Straight cable jack 16_SMA-50-1-97/19-_NE 23024708 18Straight cable jack 21_SMA-50-1-2/111_NE 22642386 18<strong>SUCOFORM</strong>_86Cable group Y11MCXStraight cable plug 11_MCX-50-2-19/111_NE 23024699 6Straight cable plug 11_MCX-50-2-19/111_NH 23032147 6Right angle cable plug 16_MCX-50-2-104/111_NH-1 23032067 6Right angle cable plug 16_MCX-50-2-104/111_NH 22658277 6Straight panel bulkhead cable jack 24_MCX-50-2-3/111_NE 22543580 6MMBXStraight cable plug 11_MMBX-50-2-4/111_NH 23033280 12.4Right angle cable plug 16_MMBX-50-2-4/111_NH 23033281 12.4Straight panel bulkhead cable jack 24_MMBX-50-2-2/111_NH 23037876 12.4HUBER+SUHNER microwave cables and assemblies 59


<strong>SUCOFORM</strong>Suitable connec<strong>to</strong>rsHUBER+SUHNERcable typeSeries, patternHUBER+SUHNERconnec<strong>to</strong>r typeItem no.Operatingfrequency(GHz)MMCXStraight cable plug 11_MMCX-50-2-1/111_OH 22649039 6Straight cable plug 11_MMCX-50-2-1/111_OE 22645297 6Right angle cable plug 16_MMCX-50-2-1/111_OH 22649044 6Right angle cable plug 16_MMCX-50-2-1/111_OE 22645957 6Straight cable jack 21_MMCX-50-2-1/111_OE 22645290 6Straight panel bulkhead cable jack 24_MMCX-50-2-1/111_OE 22645954 6NStraight cable plug 11_N-50-2-15/113_UE 22660315 18Right angle cable plug 16_N-50-2-9/13-_UH 23013729 11Straight cable jack 21_N-50-2-14/133_NE 22642666 18Straight panel bulkhead cable jack 24_N-50-2-14/133_NE 22544637 18Straight panel cable jack, flange mount 25_N-50-2-14/133_NE 22641303 18<strong>SUCOFORM</strong>_86Cable group Y11PC3.5Straight cable plug 11_PC35-50-2-4/199_UE 84009440 33Straight cable jack 21_PC35-50-2-4/199_UE 84009419 33Straight panel bulkhead cable jack 24_PC35-50-2-2/199_UE 84009405 33QMAStraight cable plug 11_QMA-50-2-3/133_NE 23017704 6Straight cable plug 11_QMA-50-2-3/133_NH 23017705 6Right angle cable plug 16_QMA-50-2-3/133_NE 23017666 6Right angle cable plug 16_QMA-50-2-3/133_NH 23017667 6Straight panel bulkhead cable jack 24_QMA-50-2-1/111_NE 23017742 6Straight panel bulkhead cable jack 24_QMA-50-2-1/111_NH 23017743 6SKStraight cable plug 11_SK-50-2-57/119_NE 84013239 40SMAStraight cable plug 11_SMA-50-2-29/119_NH 22660366 18Straight cable jack 21_SMA-50-2-15/111_NE 22544549 18Straight cable jack 21_SMA-50-2-15/111_NH 22652141 18Straight panel bulkhead cable jack 24_SMA-50-2-15/111_NE 22544532 18Straight panel bulkhead cable jack 24_SMA-50-2-15/111_NH 22645490 1860 HUBER+SUHNER microwave cables and assemblies


<strong>SUCOFORM</strong>Suitable connec<strong>to</strong>rsHUBER+SUHNERcable typeSeries, patternHUBER+SUHNERconnec<strong>to</strong>r typeItem no.Operatingfrequency(GHz)SMBStraight cable plug 11_SMB-50-2-13/111_NE 22543362 4Straight cable plug 11_SMB-50-2-13/111_NH 22658765 4Right angle cable plug 16_SMB-50-2-23/111_NE 22644079 4Straight cable jack 21_SMB-50-2-13/111_NE 22543425 4Straight panel bulkhead cable jack 24_SMB-50-2-13/111_NE 22640822 4<strong>SUCOFORM</strong>_86Cable group Y11SMCStraight cable plug 11_SMC-50-2-13/111_NE 22543363 10Straight cable plug 11_SMC-50-2-13/111_NH 22650675 10Right angle cable plug 16_SMC-50-2-25/111_NE 22644126 10Right angle cable plug 16_SMC-50-2-25/111_NH 23003713 10Straight panel bulkhead cable jack 24_SMC-50-2-13/111_NE 22640297 10Straight panel bulkhead cable jack 24_SMC-50-2-13/111_NH 22650209 10<strong>SUCOFORM</strong>SMPXStraight cable plug 11_SMPX-50-2-1/111_NE 23021825 40Right angle cable plug 16_SMPX-50-2-1/111_NE 23022715 40Right angle cable plug 16_SMPX-50-2-2/111_NE 23022716 40Straight panel cable jack, flange mount 25_SMPX-50-2-1/111_NE 23025359 40TNCStraight cable plug 11_TNC-50-2-20/103_NE 22642519 11Straight panel bulkhead cable jack 24_TNC-50-2-31/133_NE 23001721 11<strong>SUCOFORM</strong>_141<strong>SUCOFORM</strong>_141_CUCable group Y12NStraight cable plug 11_N-50-3-13/113_NE 22542083 11Straight cable plug 11_N-50-3-51/133_NE 22543919 18Right angle cable plug 16_N-50-3-15/133_NE 22648832 11Straight cable jack 21_N-50-3-11/133_NE 22543921 18Straight cable jack 21_N-50-3-51/19-_NE 22543922 18Straight panel bulkhead cable jack 24_N-50-3-14/133_NE 22542300 18Straight panel bulkhead cable jack 24_N-50-3-51/19-_NE 22642344 18Straight panel cable jack, flange mount 25_N-50-3-9/133_NE 22543952 11PC3.5Straight cable plug 11_PC35-50-3-4/199_UE 84009380 33Straight cable jack 21_PC35-50-3-3/199_UE 84009382 33Straight panel bulkhead cable jack 24_PC35-50-3-2/199_UE 84009383 33HUBER+SUHNER microwave cables and assemblies 61


<strong>SUCOFORM</strong>Suitable connec<strong>to</strong>rsHUBER+SUHNERcable typeSeries, patternHUBER+SUHNERconnec<strong>to</strong>r typeItem no.Operatingfrequency(GHz)QMAStraight cable plug 11_QMA-50-3-3/133_NE 23017695 6Straight cable plug 11_QMA-50-3-3/133_NH 23017696 6Right angle cable plug 16_QMA-50-3-3/133_NE 23017693 6Right angle cable plug 16_QMA-50-3-3/133_NH 23017694 6Straight panel bulkhead cable jack 24_QMA-50-3-3/111_NE 23017683 6Straight panel bulkhead cable jack 24_QMA-50-3-3/111_NH 23017684 6<strong>SUCOFORM</strong>_141<strong>SUCOFORM</strong>_141_CUCable group Y12QNStraight cable plug 11_QN-50-3-3/113_NE 23033393 11Right angle cable plug 16_QN-50-3-3/13-_NE 23033268 11Straight panel bulkhead cable jack 24_QN-50-3-3/13-_NE 23033423 11SMAStraight cable plug 11_SMA-50-3-77/119_NH 84005524 18Right angle cable plug 16_SMA-50-3-3/111_NE 22640073 18Right angle cable plug 16_SMA-50-3-3/111_NH 22646569 18Straight panel bulkhead cable jack 24_SMA-50-3-15/111_NE 22641153 18Straight panel bulkhead cable jack 24_SMA-50-3-15/111_NH 22645259 18TNCStraight cable plug 11_TNC-50-3-29/103_NE 22641997 11Straight panel bulkhead cable jack 24_TNC-50-3-30/133_NH 23001723 11<strong>SUCOFORM</strong>_250-01Cable group Y7716Straight cable plug 11_716-50-5-6/003_Y 84008435 7.5Straight panel cable jack, flange mount 25_716-50-5-17/000_Y 84008881 7.5NStraight cable plug 11_N-50-5-18/103_NH 84008445 11Straight cable plug 11_N-50-5-39/133_NE 22642481 18Straight cable jack 21_N-50-5-52/193_NE 22641531 18Connec<strong>to</strong>r dimensions and additional informationFor connec<strong>to</strong>r dimensions and additional information please refer <strong>to</strong> the corresponding connec<strong>to</strong>r type in theHUBER+SUHNER Coaxial Connec<strong>to</strong>rs General Catalogue or contact your local HUBER+SUHNER partner.62 HUBER+SUHNER microwave cables and assemblies