12.07.2015 Views

SEQ Non-Drinking Water Drawings 2300 Series (PDF)

SEQ Non-Drinking Water Drawings 2300 Series (PDF)

SEQ Non-Drinking Water Drawings 2300 Series (PDF)

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

100R.P.BOUNDARYR.P.BOUNDARYR.P.BOUNDARY100300300100DW NDW DW NDWDN25 PIPEREFER NOTE 3DN20 PROPERTYSERVICE MAIN TAPBALL VALVE OPENBRASS/PEDN25 TEEDRINKINGDN25 PIPEREFER NOTE 3DW NDW DW NDWBRASS/PEDN25 TEEDN25 PIPEREFER NOTE 3MINIMUM RADIUSFOR DN25 PIPE IS 500DN25 FUSIONFITTINGSREFERNOTE 5NON-DRINKING WATER NON-DRINKING WATERALL PROPERTYBRASS/PEDN32 PIPEBRASS/PE SERVICE PIPEWORKDN25 TEEREFER NOTE 3DN25 TEESHALL BESAND BEDDEDWATER(PIPE SHOWNDRINKINGROAD CROSSING CONDUITBENT FOR CLARITY)WATERDN20 PROPERTYSERVICE WATERMETER BALL VALVE,CLOSEDREFER TO NOTE 5NOTES:COMBINED SHORT SERVICES1. FOR SINGLE PROPERTY SERVICE ANDGENERAL PROPERTY SERVICEINSTALLATION DETAILS REFER TO STD DRG<strong>SEQ</strong>-WAT-1106-SET.2. FOR TWIN DRINKING WATER AND TWINNON-DRINKING WATER SERVICE TYPICALINSTALLATION DETAILS REFER STD DRG<strong>SEQ</strong>-NDW-2303-1.3. FOR PROPERTY SERVICE PIPE DETAILSREFER TO NOTES AND THE GENERALDETAILS ONSTD DRG <strong>SEQ</strong>-NDW-2303-1.4. FOR DRINKING WATER AND NON-DRINKINGWATER PROPERTY SERVICE PRESSURE PIPECOLOURS AND MARKING DETAILS REFERTO STD DRG <strong>SEQ</strong>-NDW-2303-1.5. FOR MINIMUM TAPPING DISTANCES REFERTO NOTES ON STD DRG <strong>SEQ</strong>-NDW-2303-1.6. METER BOX INSTALLED BY CIVILCONTRACTOR. WATER METERS INSTALLEDBY WATER AGENCY FOLLOWING METERAPPLICATION, SEE NOTES ON STD. DRG.<strong>SEQ</strong>-NDW-2303-1.7. DRINKING WATER = DW ANDNON-DRINKING WATER = NDW8. DIMENSIONS ARE IN MILLIMETRESUNLESS SHOWN OTHERWISE.MINIMUM RADIUSFOR DN25 PIPE IS 500PROPERTY SERVICECONDUIT DETAILSREFER <strong>SEQ</strong>-NDW-2303-1COMBINED LONG SERVICESEND ELEVATIONDRINKING WATERMAINPLANPRETAPPED TWIN CONNECTOR (DI)(FOR DN200+ DI PIPES SINGLE PORT)150 MIN 150 MINDWREFERNOTE 4TYPICAL SERVICE CROSSOVERS(FOR DN100 - DN300 PE & DI PIPES)NDWNON-DRINKINGWATER MAINCOMBINED SHORT SERVICESDN25 PROPERTY SERVICEPIPE 75 SAND BEDDED ALL AROUND100 MAX50 MINR.P. BOUNDARYREV. No.DATEDESCRIPTIONAUTH.<strong>SEQ</strong> WATERWORK PRACTICES MUST COMPLY WITH ALL APPLICABLEOCCUPATIONAL HEALTH & SAFETY LEGISLATIONWATER SUPPLY STANDARD DRAWINGTYPICAL PROPERTY SERVICESGCCCDRAWING No.SERVICE PROVIDERS DUAL WATER SYSTEMS<strong>SEQ</strong>-NDW-2304-1 ASERVICE CONNECTION MAIN TO METERLCCNOT TO SCALERCCQUUUWVERSIONORG DATE:1/1/2013


WREFER NOTE 3150 MIN. FORSAND BACKFILL.300 FOR OTHERTHAN SANDBACKFILL.150 MIN. FORROCK TRENCH.100 MIN FOROTHER THANROCK TRENCH.d100MIN.300 MIN.500 MAX.DWNDW100MIN.BACKFILLMATERIALREFER NOTE 3REFER NOTE 2OVERLAYPROVIDE ADDITIONALSIDE SUPPORTMATERIAL TO LAY MAINSOBVERT TO OBVERTSIDE SUPPORTBEDDINGTYPE O CONSTRUCTION - 850 TRENCH(NON-DRINKING WATER MAIN CLOSEST TO PROPERTY)COMMON TRENCHINGTRENCHWIDTHW850DWNOM. DIAdNDW63 x 6363 x 10063 x 150110 x 100110 x 150150 x 150150 x 200COMMON TRENCHING FORLARGER MAIN SIZES SHALL BEDETERMINED BY SERVICEPROVIDER. ADDITIONAL VERGEWIDTH AND 500 BETWEENMAINS SHALL BE PROVIDED.TYPE8ABCDEFGNOTES:1. FOR EXCAVATION, BEDDING AND BACKFILL REQUIREMENTS REFER CODE.2. A GEOTEXTILE BARRIER SHALL BE PROVIDED AT THE INTERFACE OFOVERLAY AND BACKFILL.3. THE ALIGNMENT OF ALL PIPES SHALL BE DEFINED BY A MARKER TAPEBURIED AT A DEPTH OF 300mm MINIMUM. THE TAPE SHALL CONTAIN ACONTINUOUS METAL STRIP.4. NON-DRINKING WATER MAIN = NDW & DRINKING WATER MAIN = DW.5. DIMENSIONS ARE IN MILLIMETRES UNLESS SHOWN OTHERWISE.REV. No.DATEDESCRIPTIONAUTH.<strong>SEQ</strong> WATERWORK PRACTICES MUST COMPLY WITH ALL APPLICABLEOCCUPATIONAL HEALTH & SAFETY LEGISLATIONWATER SUPPLY STANDARD DRAWINGTYPICAL WATER MAINGCCCDRAWING No.SERVICE PROVIDERS TRENCH & BEDDING DETAILS<strong>SEQ</strong>-NDW-2307-1 ADUAL WATER SYSTEMSLCCNOT TO SCALERCCQUUUWVERSIONORG DATE:1/1/2013

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!