ATySA new intelligent, modularswitching conceptA COMPACT secure transfer SYSTEM> Two load break switches with highshort circuit withstand> Safety disconnection between loadsand upstream power sources> Back-to-back assembly fromfactory garantees interlocking> Load bridging made easy by usingthe bridging bars available asaccessoriesATYS 298 aflexible UPGRADEABILITY> Plug-in optional modules• RS 485 JBUS / Modbuscommunication module(programming software can bedownloaded from the <strong>Socomec</strong>site: www.socomec.com)• Module configurable with2 Inputs / 2 Outputs (networkpriority, load shedding, remotemanual re-transfer etc.)A SIMPLE, ADAPTABLE CONTROL MODULE> Easy selection of automatic or manual control> Handle for manual operation> Padlockable facilityATYS 289 AProgramming software> Dedicated accessories• Voltage sensing and supply kitATYS 016 COptional modules• Atys D10 and D20 remoteinterfacesATYS 013 CCOMPLETE CONTROL FUNCTIONS> Voltage / frequency detection limits and verification of phaserotation> <strong>Switch</strong>ing cycles can be pre-programmed or customisedATYS 008 C<strong>Automatic</strong> mode (AUT)ATYS 011 A• Bridging bars, terminal shrouds,terminal screens, optionalpadlocking in 3 positions,special locks, additionalauxiliary contacts…ATYS 597 A ATYS 565 CATyS D10 / D20 remote interfacewith RJ45 connectionATYS 564 CSource 1 failureEnd “t” source 1 failureGenerator startGenerator shutdownEnd “t” cool down timer before generator<strong>Switch</strong> to position IEnd “t” stop to position 0Rear view> A double power supply moduleThe DPS module allows the ATyS 3s to be powered from the availablesource (Normal / Emergency).Source 2 availability<strong>Switch</strong> to position 0End “t” source 2 availability<strong>Switch</strong> to position 0End “t” stop to position 0noSemi automatic modeEnd “t” source 1 availabilityyesmanualoperation<strong>Switch</strong> to position IISource 1 availabilityATYS 028 E GBExample (generator application):Source 1 : priority power sourceSource 2 : backup power source“t” : timerATYS 596 BATyS 3sDPSdedicated CONTROL LOGIC> Genset start / stop control> Luminous mimic diagramshowing status of powersources and position ofthe switch> Screen displays programmedand controlled values> Run “permutation cycle” tests either on or off load> Electrical position control (via keypad or remote)ATYS 288 BEASY MAINTENANCE> The motorised module andthe control module can bereplaced seperately withoutdisconnecting the powerconnectionsATYS 015 C

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!