12.07.2015 Views

IEC 60870-5-104 Server to DNP 3.0 over Ethernet Gateway

IEC 60870-5-104 Server to DNP 3.0 over Ethernet Gateway

IEC 60870-5-104 Server to DNP 3.0 over Ethernet Gateway

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>IEC</strong> <strong>60870</strong>-5-<strong>104</strong> <strong>Server</strong> <strong>to</strong><strong>DNP</strong> <strong>3.0</strong> <strong>over</strong> <strong>Ethernet</strong> <strong>Gateway</strong>5201-<strong>104</strong>S-<strong>DNP</strong>SNETThe <strong>104</strong>S-<strong>DNP</strong>SNET modules are the ideal solution forthe many applications where <strong>IEC</strong> <strong>104</strong> <strong>Server</strong>connectivity can be used <strong>to</strong> integrate <strong>DNP</strong> <strong>3.0</strong> DF1Master or Slave devices in<strong>to</strong> a system. The <strong>IEC</strong><strong>60870</strong>-5-<strong>104</strong> <strong>Server</strong> gateway is a powerful module designed with<strong>Server</strong> support, enabling easy connection <strong>to</strong> an <strong>IEC</strong> <strong>104</strong>master device. In combination with the <strong>DNP</strong> <strong>over</strong><strong>Ethernet</strong> device support, the module provides a verypowerful interface <strong>to</strong> the many <strong>DNP</strong> <strong>3.0</strong> devices whichare in use in the industrial marketplace <strong>to</strong>day.Applications for the module are found in most industries,especially Manufacturing, Oil and Gas, Electrical Powerand Food Processing.How <strong>to</strong> Contact Us: Sales and SupportAll ProSoft Technology® products are backed withunlimited technical support. Contact our worldwideTechnical Support team directly by phone or email:Asia Pacific+603.7724.2080, asiapc@prosoft-technology.comLanguages spoken include: Chinese, Japanese, EnglishEurope – Middle East – Africa+33 (0) 5.34.36.87.20, support.EMEA@prosofttechnology.comLanguages spoken include: French, EnglishNorth America+1.661.716.5100, support@prosoft-technology.comLanguages spoken include: English, SpanishLatin America (Sales only)+1.281.298.9109, latinam@prosoft-technology.comLanguages spoken include: Spanish, EnglishBrasil+55-11.5084.5178, eduardo@prosoft-technology.comLanguages spoken include: Portuguese, English<strong>IEC</strong> <strong>60870</strong>-5-<strong>104</strong> <strong>Server</strong> <strong>to</strong><strong>DNP</strong> <strong>3.0</strong> <strong>over</strong> <strong>Ethernet</strong> <strong>Gateway</strong>5201-<strong>104</strong>S-<strong>DNP</strong>SNETThe ProLinx <strong>IEC</strong><strong>60870</strong>-5-<strong>104</strong> <strong>Server</strong> <strong>to</strong> <strong>DNP</strong> <strong>3.0</strong> <strong>over</strong> <strong>Ethernet</strong>creates a powerful connection between devices on an <strong>IEC</strong> <strong>104</strong><strong>Server</strong> network and a <strong>DNP</strong> device. The module is a stand-alone DINrail-mounted pro<strong>to</strong>col gateway that provides one <strong>Ethernet</strong> port.The <strong>104</strong>S module accepts commands from an attached master uni<strong>to</strong>n the network and generates unsolicited messages.The ProLinx module supports the <strong>DNP</strong> <strong>3.0</strong> pro<strong>to</strong>col as a server usingthe TCP and UDP pro<strong>to</strong>cols using service port 20000. This port isfully configurable.<strong>IEC</strong> <strong>60870</strong>-5-<strong>104</strong> <strong>Server</strong>Operating in the <strong>Server</strong> mode, the pro<strong>to</strong>col driver accepts commandsfrom an <strong>IEC</strong>-<strong>60870</strong>-5-<strong>104</strong> Client <strong>to</strong> read/write data s<strong>to</strong>red in the module'sinternal registers.The <strong>104</strong>S module acts as an input/output module between the<strong>IEC</strong> <strong>60870</strong>-5-<strong>104</strong> <strong>Ethernet</strong> network and many of the other serial andnetwork pro<strong>to</strong>cols, as well as several proprietary interfaces.General specifications include:• User-definable module memory usage• Pro<strong>to</strong>col implementation conforms <strong>to</strong> the <strong>IEC</strong> <strong>60870</strong>-5-<strong>104</strong>specification with fully configurable parameters• SNTP (Simple Network Time Pro<strong>to</strong>col) timestamping for detailedlogging of data transactions.The <strong>104</strong>S module accepts commands from an attached master uni<strong>to</strong>n the network and generates unsolicited messages. These last setsof messages are either spontaneous or cyclic. Data transferred <strong>to</strong> thehost is derived from the module's internal database. The remotemaster device can control data in the database and hence thedevices connected using the other pro<strong>to</strong>col in the module usingstandard control messages supported in the pro<strong>to</strong>col. The remotemaster device uses the fully-configured databases in the module <strong>to</strong>control outputs and moni<strong>to</strong>r inputs.<strong>IEC</strong> <strong>60870</strong>-5-<strong>104</strong> <strong>Server</strong>Configurable ParametersOverride StartDTClear queue on closet1 timeout set valuet2 timeout set valuet3 timeout set valuek (maximum queue)w (latest ack threshold)Time DB Offset


<strong>DNP</strong> <strong>3.0</strong> TCP/IP <strong>Server</strong>The <strong>DNP</strong>SNET pro<strong>to</strong>col driver exists as a single service port(<strong>DNP</strong>SNET port 20000) implementation that supports a single TCPport connection and multiple UDP ports on a TCP/IP <strong>Ethernet</strong>network. The <strong>DNP</strong>SNET port operates as a server, supporting the<strong>DNP</strong> <strong>3.0</strong> pro<strong>to</strong>col in a Level 2 implementation using the <strong>DNP</strong> UserGroup recommended extension for use on LAN/WAN.General ParametersInternal DatabaseBinary Inputs: 8000 points (500 words)Analog Inputs: 500 pointsCounters: 250 (500 words)Binary Outputs: 2000 points (125 words)Analog Outputs: 500 points<strong>DNP</strong> Mode <strong>DNP</strong> <strong>3.0</strong> Slave – Level 2Specification<strong>Ethernet</strong> Port (<strong>Ethernet</strong>modules only)Application Serial PortsSerial Port IsolationShipped with Each UnitDescriptionRJ45 Connec<strong>to</strong>rLink and Activity LED indica<strong>to</strong>rsRS-232/422/485RS-232 handshaking configurableRS-422/485 screw termination included2500V RMS port signal isolation per UL15773000V DC min. port <strong>to</strong> ground and port <strong>to</strong>logic power isolationMini-DIN <strong>to</strong> DB-9M serial cables4 ft RS-232 configuration cable2.5mm screwdriverCD (docs and Configuration utility)RS-422/485 DB-9 <strong>to</strong> Screw TerminalAdap<strong>to</strong>r (1 or 4, depending on ports)<strong>DNP</strong> <strong>Server</strong>Service Port 20000Pro<strong>to</strong>colsTCP (1 connection) and UDPNode address0 <strong>to</strong> 65534 (software selectable)The <strong>DNP</strong>SNET module accepts <strong>DNP</strong> commands <strong>to</strong> control andmoni<strong>to</strong>r the data s<strong>to</strong>red in the <strong>DNP</strong> databases. These data arepassed between the module and the other pro<strong>to</strong>col on the ProLinxmodule.General SpecificationsThe ProLinx Communication Modules provide connectivity for two ormore dissimilar network types. The modules, encased in sturdyextruded aluminum, are stand-alone DIN-rail mounted pro<strong>to</strong>colgateways, providing communication between many of the mostwidely used pro<strong>to</strong>cols in industrial au<strong>to</strong>mation <strong>to</strong>day.Hardware SpecificationsSpecificationPower SupplyCurrent LoadOperating TemperatureS<strong>to</strong>rage TemperatureRelative HumidityDimensionsLED Indica<strong>to</strong>rsConfiguration Serial PortDescription24 VDC nominal18 <strong>to</strong> 36 VDC allowedPositive, Negative, GND Terminals2.5 mm screwdriver blade500 mA max@ 24 VDC–20 <strong>to</strong> 50°C (–4 <strong>to</strong> 122°F)–40 <strong>to</strong> 85°C (–40 <strong>to</strong> 185°F)5 <strong>to</strong> 95% (non-condensing)Standard: 5.20H x 2.07W x 4.52D in.(13.2cmH x 5.25cmW x 11.48cmD)Extended: 5.20H x 2.73W x 4.52D in.(13.2cmH x 6.934cmW x 11.48cmD)Power and Module StatusApplication StatusSerial Port Activity LEDSerial Activity and Error LED StatusDB-9M RS-232 onlyNo hardware handshakingProSoft Configuration BuilderProSoft Configuration Builder (PCB) provides a quick and easy way<strong>to</strong> manage module configuration files cus<strong>to</strong>mized <strong>to</strong> meet yourapplication needs. PCB is not only a powerful solution for newconfiguration files, but also allows you <strong>to</strong> import information frompreviously installed (known working) configurations <strong>to</strong> new projects.Additional ProductsProSoft Technology offers a full complement of hardware andsoftware solutions for a wide variety of industrial communicationplatforms.Visit our web site at http://www.prosoft-technology.com for acomplete list of products.Ordering InformationTo order this product, please use the following:5201-<strong>104</strong>S-<strong>DNP</strong>SNET <strong>IEC</strong> <strong>60870</strong>-5-<strong>104</strong> <strong>Server</strong> <strong>to</strong><strong>DNP</strong> <strong>3.0</strong> <strong>over</strong> <strong>Ethernet</strong> <strong>Gateway</strong>To place an order, please contact your local ProSoft Technologydistribu<strong>to</strong>r. For a list of ProSoft distribu<strong>to</strong>rs near you, go <strong>to</strong>http://www.prosoft-technology.comDistribu<strong>to</strong>rs:Place your order by email or fax <strong>to</strong>:North American / Latin American / Asia Pacificorders@prosoft-technology.com,fax <strong>to</strong> +1 661.716.5101Europeeurope@prosoft-technology.com,fax <strong>to</strong> +33 (0) 5.61.78.40.52Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved.May 03, 2007

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!