<strong>GIACOMINI</strong> U.K, U.K. LTDUNDERFLOOR UNDERFLOOR HEATING & COOLING HEATINGGUARANTEESGuaranteedunderfloor HEATINGGiacomini UK is the only provider of underfloorheating offering a complete package frommanufacture and design through to installationand commissioning, with the added reassuranceof our unique 10 year system guarantee.Our project specific 10-year system guaranteepromises that our pipework, manifolds andinstallation will be free of defects for the guaranteeperiod. Excluding electrical controls and pumps,which are guaranteed for two years.With so many elements being taken care of inhouseby our team of project managers, engineers,designers and installers, all our <strong>UFH</strong> systemguarantees are given with great confidence.We are also proud to be able to offer all ourcustomers the most comprehensive range ofcomponent guarantees, covering:• Pipework (50 years)• Brass (10 years)• Electronic controls & pumps (2 years)As Giacomini is in the unique position to beable to manufacture all of its underfloor heatingcomponents, we are able to guarantee you apermanent supply of spare parts. This guaranteesthe end user the ability to update or amend their<strong>UFH</strong> system if ever required.DovecotE Meadow RETIREMENT VILLAGESUNDERLAND SYSTEM: SCREEDED SIZE: 17,615 m 2Dovecote Meadow Retirement Village, is a multi-occupancyextra care scheme that offers shops and other amenities to itsolder residents. Giacomini has provided underfloor heating toits 176 apartments and a number of the communal areas.Giacomini were responsible for the installation of all pipeworkand manifolds. This is the largest single <strong>UFH</strong> project Giacominihas undertaken at a total of 17,615 m 2 ; using 182 distributionmanifolds and more than 34,000 metres of piping for theproject.The entire project is covered by our 10 year system guaranteewhich is a great reassurance to the developers and those whopurchase apartments once the works are complete.PROJECTT: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345PAGE: 03


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR HEATING & COOLINGCOMPATIBLE ENERGY SOURCESBIOMASSSOLARAIR SOURCEGROUNDSOURCEWith increased support from government initiatives such as Green Deal and Renewable Heat Incentive (RHI)encouraging home and business owners to use more green technology, underfloor heating is swiftly becomingthe heating partner of choice for many renewable energy systems.When linked with technologies such as ground and air source heat pumps, biomass boilers or solar thermalsystems, underfloor heating can offer its users a sustainable solution to cutting energy costs and reducing theircarbon footprint.Underfloor heating compliments these renewable energy sources because it uses less energy for distributionthan a traditional radiator system. This is due to its low flow and return temperatures.The choice doesn’t end there. Giacomini are proud to introduce you to H2YDROGEM®, our innovative catalyticburner that allows the production of thermal energy totally free from fossil-fuels.The H2YDROGEM® was developed after an extensive programme of research and development that aimed tofind a zero emissions heating cycle. The H2YDROGEM® produces heat by combining hydrogen and air inside acatalyser, uniquely this method of heat production does not combust the gasses, which means no bi-productsof combustion or greenhouse gasses. By mixing the two elements together it produces steam, which thencondenses and in turn produces heat energy. Heat produced by the reaction is removed by a heat exchangerembedded in the burner. The water temperature is between 35 and 40°C, ideal to feed low temperature heatingsystems such as underfloor heating.HYDROGENPAGE: 06T: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.uk


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR UNDERFLOOR HEATING & COOLING HEATINGRENEWABLE ENERGY SYSTEMMODULAR UNDERFLOOR HEATINGSYSTEM: modular SIZE: 8M x 4M MODULESSchools across the UK are enjoying the benefits of modularunderfloor heating, designed and installed by Giacomini UKduring the summer holidays.Giacomini modular systems consist of pre-built moduleswhich are installed in 8 metre x 4 metre sections. Thesections are created in a controlled factory environment andare then delivered to site and craned into position to simplybe connected together.Our modular underfloor heating is extremely cost efficientand helps keep the project comfortably within budget andeffortlessly within the school holiday timetable.PROJECTSeveral schools selected for their modular underfloorheating system to work in conjunction with an air sourceheat pump, this is ideal for <strong>UFH</strong> as it operates at much lowertemperatures.T: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.ukPAGE: 07


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR RESIDENTIAL UNDERFLOOR HEATING HEATINGPROJECTPROJECTCONVECTIONHAMMAM A traditional BATHS radiator system transfers energy into aLONDON room or SYSTEM: space largely Solid by and convection. PLATED SIZE: 1,273 m 2A convection current is formed when a radiatorIn 2012, begins Giacomini to heat developed the air in contact a bespoke with underfloor it. By heating heatingsystem the for air a it luxury becomes London less house. dense, Two and different rises above systems the wereused cooler (1: solid air floor surrounding 2: plated it. system) to cover the nine levels ofthe property, stretching from the sub-basement to the fifthfloor. These In addition thermally to induced the underfloor air movements heating cause within a the mass mainhouse, of warm Giacomini air to were collect also at asked ceiling to level. supply As and the install air-cools a solidfloor rapidly system it within sinks quickly the property’s to the floor, Hammam meaning Room at (similar allto a times Turkish the bath). floor This remains was coolest a unique part request, of the room. requiring This theunderfloor cool air heating is then re-cycled system to towards be install the vertically radiator within where thewalls it of starts the it room. cycle The again. use of underfloor heating within thespace allowed our client to replicate the traditional warmingroom, • Warm often ceiling found in • Cold traditional feet • Heat Hammam loss through spas. roof• Constant movement of air - causing the transferof dust particles across the roomCONVECTIONBalhousie A traditional MONKBARNS radiator system transfers Care Home energy into aArbroath room or space SYSTEM: largely Solid by convection.and PLATED SIZE: 2,920 m 2Giacomini A convection UK was proud current to is be formed selected when to assist a radiator BalhousieCare begins Group with to heat the development the air in contact of their with state-of-the-art it. By heating carehome the in Arbroath. air it becomes less dense, and rises above thecooler air surrounding it.Underfloor heating is a popular method of heating within thecare These and nursing thermally sector induced due to air its movements excellent health cause and a mass safetycredentials of warm (no air dangers to collect such at as ceiling protruding level. or As hot the surfaces) air-cools andthe flexibility rapidly it it sinks offers quickly in terms to of room the floor, layout meaning (with no at intrusive allradiators).times the floor remains coolest part of the room. ThisMonkbarns cool air Care is then House re-cycled was constructed towards the using radiator a solid where floorsystem it starts throughout it cycle again. the ground floor, and plated floor systemat first floor level. Each bedroom was designed using separateheating• Warmzones,ceilingallowing• Cold feetresidents• Heat lossindependentthrough roofcontrol oftemperature • Constant and movement timing. of air - causing the transferof dust particles across the roomOur underfloor heating systems continue to be a popular choice within residential properties, suiting both new build andrefurbishment projects.Its compatibility with both mainstream and renewable technologies offers both homeowners and developers the ability to designtheir properties to suit all budgets and lifestyle choices.Underfloor heating can be adapted to suit rooms of varying size, with installation available in singular rooms or across a wholedevelopment.• Comfort (No cold spots and no cold feet).• Cost Effective (Significant cost savings through lower operating temperatures).• Flexibility In Design (Allows you to design and furnish your room without compromise).PAGE: 08T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345


<strong>GIACOMINI</strong> U.K. LTDCOMMERCIAL UNDERFLOOR HEATINGRadiant ENERGYNational An underfloor Rail system, however, heats almost entirelyMILTON by radiation. KEYNES By SYSTEM: circulating solid warm FLOOR water SIZE: in pipes 2,644 m 2installed within the floor construction, it producesThe radiant vast energy, 2,644 square which metre is emitted atrium evenly at Milton from the Keynes floor railwaystation surface. will The offer large rail surface users a warm area of welcome the floor with means Giacomini’sunderfloor the system heating. does not have to be heated to the sameGiacominihigh temperatureinstalled aassolida radiator,floor system,generallycompleterunningwithat75mmFibrescreed around 45 and degrees 18 mm as opposed PE-X pipework. to 80 degrees used inradiator systems.Fifteen heating manifolds provide the floor’s warmth and areall Heating completely from hidden the floor from upwards, view. the radiant energytransfers to surrounding surfaces, which in turnGiacominibecome secondaryUK designed,heatinstalledemitters.andThiscommissionedresults in atheheating system in four separate stages.more consistent temperature across the room.• Natural form of heating, like the sun • Even heating• Comfortable temperatures • No cold spots• Minimal draughts • Low running temperaturesRadiant ENERGYTHE An underfloor SHARDsystem, however, heats almost entirelySYSTEM: by radiation. Solid By FLOOR circulating with warm sand water & cement in pipes screedinstalled within the floor construction, it producesradiant energy,SIZE:which is emitted evenly from the floorGiacomini UK ‘s solid floor underfloor heating system has beensurface. The large surface area of the floor meansinstalled into London’s prestigious Shard development.the system does not have to be heated to the sameThe high installation temperature took as place a radiator, on the generally building’s running ground at floorwithin around the 45 entrance degrees lobby, as opposed and on to the 8069th degrees floor, used which in housesthe radiator spectacular systems. viewing gallery.The Heating public from will the be able floor to upwards, head up the to radiant the viewing energy level ofEurope’stransferstallestto surroundingbuilding, to takesurfaces,in breathtakingwhich inviewsturnof up to40 miles across the city.become secondary heat emitters. This results in aGiacomini more consistent UK are temperature honoured to across have been the room. involved in one ofthe most exciting building developments London has seen fora•longNaturaltime.form of heating, like the sun • Even heating• Comfortable temperatures • No cold spots• Minimal draughts • Low running temperaturesPROJECTPROJECTGiacomini has extensive experience in designing, supplying and installing underfloor heating for a wide range of commercialprojects; including schools, hospitals, offices, prisons, train stations, garden and leisure centres.As energy prices continue to rise, underfloor heating can provide major savings on heating for your commercial property. It isestimated that in commercial properties underfloor heating can reduce heating costs by up to 40% when compared to the energycosts of conventional radiator or hot air heating systems.An area heated with a low temperature radiant system, especially in commercial properties where height and surface areas areoften significant, will have low air movement. This avoids the air stratification and the notable upward dispersion of heat thatoccurs with a traditional heating system.• Reduced Vandalism (Lower risk of site thefts due to its limited scrap value).• Improved Health & Safety (No risk from high surface temperatures & sharp edges).• Healthier Environment (Increased staff well-being & productivity, reduced illnesses).T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345PAGE: 09


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR SCREEDED UNDERFLOOR HEATING HEATINGTYPICAL SCREEDED UNDERFLOOR HEATINGALTERNATIVE SCREEDED STRUCTURES AVAILABLEPIPEWORKU - CLIPINSULATION (Min 25mm )SUBFLOORFLOOR COVERING(Min: 75mm Fibrescreed50mm Flowing Screed)SCREEDBORDERINSULATION(8mm)VAPOURBARRIER(500 Gauge)DAMP PROOFMEMBRANE(1200 Gauge)SCREEDED FLOOR SYSTEM.Solid floor underfloor heating systems include all floor constructions that have underfloor heating pipework embedded inconcrete or screed. They include concrete structural floors and concrete screed floors, as well as block and beam floors witha screed finish.The type of solid floor selected will depend upon the structural requirements of the floor. A typical screeded floor sectionis shown above, pointing out the different elements of the floor structure and showing the Giacomini underfloor heatingpipework within the structure.The sub-base will usually be made up of two layers, the first being a compact or consolidated hard-core, which will havea sand binding layer on top. A damp proof membrane (DPM), typically 1200 Gauge, is usually included at this level; this isessential to stop moisture transfer into the concrete base.Insulation is then laid. This is necessary to meet current building ‘U’ values and to comply with current building regulations.As well as to reduce downward heat loss.Giacomini PE-X pipework is then laid, held in place with poly-propylene U-Clips and the screed. The makeup and thicknessof the screed will be determined by the structural requirements of the floor. Screed used for this type of underfloor heatingshould not include any insulating materials. The heating pipework is positioned giving a minimum screed cover of 30mm(25mm + 5mm deflection for clips).Screed floors will be laid onto a sub-base, which can be a concrete base or a block and beam sub floor.PAGE: 10T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345


<strong>GIACOMINI</strong> U.K. LTDJOISTED/ BATTEN UNDERFLOOR HEATINGTYPICAL JOISTED UNDERFLOOR HEATINGPIPEWORKFLOOR COVERINGQUILT INSULATIONALUMINIUM HEAT DIFFUSION PLATE (0.7 Gauge)RIGID INSULATION (Min 25mm )SUPPORT BATTENSJOISTSJOISTED/BATTEN FLOOR SYSTEM.Underfloor heating systems may be successfully installed within suspended floors providing the floor is constructed to suitthe application. Therefore it is essential that planning begins at an early stage in the project and the building contractor isinformed of the construction required for the radiant panel. The underfloor heating plated system can be easily adapted toaccommodate a number of special floor details, including sprung floors and cross battens.Suspended floor systems include both joisted floors with conventional joists, as well as solid floors with battens fixed tothe floor. The underfloor heating system consists of aluminium diffusion plates spanning between the joists or battens. Thediffusion plates are grooved to accept the heating pipework.Sprung floor: With battens loose laid onto blocks supported on a solid base, the underfloor heating is fitted in the normalmanner, but using double sided tape to hold the plates in position. The use of tape avoids dislodging the battens whenfixing the plates.Cross battens: If joist centres are not suitable for installing the diffusion plate, the floor can be cross battened with thebattens fixed at 400mm centres (this work must be completed prior to Giacomini installers arriving on site). The underfloorheating system can be installed on the cross battens. Outputs from the plated system are limited to around70W/m 2 but will depend upon the floor finishes.T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345PAGE: 11


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR FLOATING UNDERFLOOR HEATING HEATINGTYPICAL FLOATING UNDERFLOOR HEATINGPIPEWORKALUMINIUM HEATDIFFUSION PLATE(0.7 Gauge)FLOORCOVERFLOOR DECKPOLYSTYRENE INSULATIONPANELS (Min 30mm)OVERSITE SLABFLOATING FLOOR SYSTEM.Floating floors reduce the overall loading within a building, reducing the weight of the floor compared to other floor systems.Insulation panels are pre-grooved at 200mm centres with a bell shaped groove at one end of the panel to allow the pipe toturn at the end of its run.The grooves are made so an aluminium plate can be installed to help dissipate the heat from the pipe to the underside of thefloor. The panels are produced in a range of thicknesses from 30mm–100mm. The installation of this system is very simple.Panels are laid with the bell at each end of the room, with panels butt jointed and cut to size.Once the panels are in place, the aluminium plates are pressed into the grooves, leaving a gap at each end for the pipe turns.PAGE: 12T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345


<strong>GIACOMINI</strong> U.K. LTDSUSPENDED UNDERFLOOR HEATINGTYPICAL SUSPENDED UNDERFLOOR HEATINGPIPEWORK& U - CLIPCHIPBOARD/PLY DECKRIGID INSULATION (Min 25mm )SUPPORT BATTENSCHIPBOARD/PLYJOISTSAIR GAP(Max 20mm)SUSPENDED FLOOR SYSTEM.This underfloor heating structure is created by fixing supporting battens between each joist. These battens support achipboard/ply base with rigid insulation cut to fit between the joists. A minimum insulation thickness of 25mm is required.The pipe is then clipped on top of the rigid insulation using poly-propylene U-Clips and the flooring is finally fitted above thejoists.Please note: The voids above the pipework should not exceed 20mm in order to retain efficiency.ADDITIONAL INFORMATIONMaximum floor temperatures.We design our systems based on CIBSE guidelines which state 29 o C maximum floor temperature for occupied areas, 33 o C towet rooms, and up to 35 o C for exposed/perimeter areas. It’s also often necessary to limit the floor to 27 o C where timber floor /vinyl adhesive manufacturers state it as a requirement.T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345PAGE: 13


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR HEATING & COOLINGSCREEDGiacomini’s Guide To ScreedWith many years of experience within the underfloor heating sector, Giacomini has built up several strong relationships withquality UK screed providers. We are proud to be able to offer their services within our underfloor heating package, giving you asingle point of responsibility.When considering a screeded floor system there are two main types of screed to consider.Flowing Screed (Liquid)Flowing screeds are generally made from a mixture ofcalcium sulphate, sand and various other chemicals toproduce a ‘Liquid’ screed. These are pre-mixed whendelivered to site and ‘poured’ then levelled. This meansthat larger areas can be installed faster. Wire mesh can beused to enhance the strength of these screeds. In addition,several manufacturers are now replacing calcium sulphatewith cement to produce a ‘Liquid-Cementitious’ screedwhich is stronger and faster drying, although this is still notcommon.Advantages:• Quicker to install in larger areas.• Requires fewer expansion joints.• Better thermal conductivity.• Lower screed thickness required.Sand & Cement Based Screed(Semi-DRY)Sand and cement screeds are generally a 4:1 mixture of sandand cement, which are usually reinforced with PP fibres.These screeds are normally mixed on site but can comeready mixed. Various additives can be added to enhancethe drying times or strength of these screeds.Advantages:• Can be used for wet areas.• Can be laid to falls.• Can be mixed on site.• Less preparation required.• Generally quicker drying times.If you are interested in including one of our approved screeding services within your quotation, please advise your localGiacomini representative.PAGE: 14T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR UNDERFLOOR HEATING & COOLING HEATINGScreed Types & ASSOCIATED DRYING Times * .PRODUCT Name1:4 FibrescreedMinimum Thickness75mm commercial /65mm domesticFOOTTRAFFICDryingSiteTRAFFIC4 days 7 daysLiquid Screed 50 mm 48 hours 7 daysTimesDRYINGTime1mm per day upto 40 mm. 1/2mm per day forfurther thickness1mm per day upto 40 mm. 1/2mm per day forfurther thicknessCuringTime7 daysn/aTru ScreedPremier Screed75mm commercial /65mm domestic75mm commercial /65mm domestic3 days 5 days 2 - 3 mm per day 7 days2 days 7 days 2 - 3 mm per day 7 daysPremier HD 75mm 2 days 7 days 2 - 3 mm per day 7 daysCem Screed75mm commercial /65mm domestic24 hours 3 days 7 days at 25mm 7 daysCem Screed 5 75mm 1 day 3 days 7 days at 50mm 24 hoursMapei Topcem 55mm 12 hours 24 hours 4 days at 50mm n/aFlexi Dry F0 55mm 12 hours 12 hours 3 days n/aFlexi Dry F1 65mm 12 hours 12 hours 7 days n/aFlexi Dry F2 65mm 12 hours 12 hours 14 days n/aFlexi Dry F3 65mm 12 hours 7 days 21 days n/aPolymer Screed 75mm 4 days 7 days 25mm per month 7 daysArdex A35 75mm 3 hours 24 hours 24 hours n/aKnopp Contopp 10 75mm 36 hours 7 days 3mm per day 2 daysKnopp Contopp 15 75mm 36 hours 48 hours 8-10 days 2 daysKnopp Contopp 20 75mm 24 hours 24 hours 2-4 days 2 days*The drying times shown are based on ideal site conditions and are intended for guidance onlyT: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345PAGE: 15


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR HEATING & COOLINGkidbrooke VILLAGEGREENWICH SYSTEM: solid FLOOR SIZE: 10,174 m 2Kidbrooke Village is a £1 billion regeneration projectorganised between Berkeley Homes, Greenwich Counciland the Homes & Communities Agency. The vast mixedusedevelopment will include high quality homes,surrounded by open space, businesses, and communityfacilities.Giacomini UK was drafted in on the 2nd phase of theproject to install a dual heating system, utilising both ourunderfloor heating and heat interface units.PROJECTOur solid floor underfloor heating system was selected toheat both the town houses and core apartments.Seventy-five twin heat interface units were installedwithin in the core apartments blocks.The primary circuit supplies two heat exchangers withinthe unit that in turn supply the underfloor heating andgenerate instant domestic hot water.This offers an effective and fair solution to providingheating and instantaneous hot water for communalproperties.In 2013 Giacomini launched its latest heat interface unit,the G5, which is available to order directly from the UKoffice.To find out more about ourNew Heat Interface Unit,please scan the QR code >>PAGE: 16T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR UNDERFLOOR HEATING & COOLING HEATINGFLOOR FINISHESWhen selecting the final floor finish, consideration must begiven to its suitability and the affects that it may have onthe performance of your <strong>UFH</strong> system.Three factors must be taken into account:• Thermal resistance:This is the measurement of temperature difference bywhich a material resists a heat flow. This can be influencedby factors such as the thickness and thermal conductivityof the material. Thermal resistance of flooring is shown viaits ’ Tog value’.• Temperature constraints:When selecting your flooring its is important to decipherwhether any of its material properties have any thermalrestrictions to consider. For example, certain vinyl adhesivesand timber flooring may not exceed 27 °C. This is easilycompensated for at the design stage.• Suitability of the underfloor heating floor structure:Depending on the type of underfloor heating system youchoose there may be additional factors within its buildupthat could impact your floor selection. For example,when underfloor heating has been applied to a large area,expansion joints may be required in order to control anyheat-induced expansion or contraction. It is important toconsider this movement when selecting your floor finish.There are four basic types of floor finish which should beconsidered: ceramic, which includes natural stone materialssuch as flag stones, plastic or vinyl floor coverings, timberand timber products, and carpet.The table below demonstrates the tog values of differentfloor finishes. A higher thermal resistance (Tog value)will reduce the heat output into the designated space,instead raising the temperature within the underlying floorstructure.• Ceramic tiles • Limestone • MARBLE• POLISHED SCREED • SlatE • flagStonES• VINYL • LINOLEUM • Marmoleum• laminatE TILES • RUBBER • AMTICOCERAMIC EXAMPLESACCEPTABLE thermal resistancesFINISH TOG RESISTANCE15mm Ceramic Tile 0.17 0.017mK/W20mm Marble 0.10 0.001mK/WPlease note:• Please take into consideration expansion joints priorto laying the ceramic floor finish.• Flexible adhesive must be used to reduce the risk ofthe tile or stone splitting or cracking.ACCEPTABLE thermal resistancesFINISH TOG RESISTANCE2mm Vinyl 0.30 0.03mK/W2mm Linoleum 0.74 0.074mK/WPlease note:• Always check the manufacturer’s recommendedmaximum floor surface temperature to ensure theproduct is suitable for use with <strong>UFH</strong>.PLASTIC & VINyL EXAMPLESTIMBER EXAMPLES• Engineered timber• Hardwood• Softwood • PARQUET • BAMBOOACCEPTABLE thermal resistancesFINISH TOG RESISTANCE18mm Oak 1.13 0.113mK/W22mm Ply/Chipboard 1.57 0.157mK/WPlease note:• Take in to consideration board width andthickness when specifying the floor finish.• Timber floor surface temperatures are limited to27°C, to avoid problems with moisture within thewood.• CARPET • CORK • CoirACCEPTABLE thermal resistancesFINISH TOG RESISTANCECombined carpet (100polypropylene hardtwist) and underlay1.90 0.190mK/W(waffle)Combined carpet (100wool loop pile) andunderlay(rubber crumb)1.70 0.170mK/WPlease note:• We recommend a maximum combined Tog value of2.5 for carpet and underlay.CARPET EXAMPLESThe information contained in this document is intended for general guidance only.Please contact your selected flooring manufacturer for accurate data.T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345PAGE: 17


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR HEATING & COOLINGUNDERFLOOR HEATING PIPE LAYOUTPAGE: 18T: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.uk


T: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.uk PAGE: 19


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR HEATING & COOLINGDISTRIBUTION MANIFOLDS4132PAGE: 20T: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.uk


Underfloor HEATING Distribution Manifoldsare designed for use with pre-blended CIRCUITSwhich HAVE been SET to the LOW TEMPERATURESrequired for UNDERFLOOR HEATING SYSTEMS.56To be used when water temperature is controlled at theboiler (heat source), and sent to the manifold at the desiredunderfloor heating temperature.The R553DM kit includes isolating ball valves, micrometricflow adjustment, pressure & temperature gauges, drain andfill points, flow meters, brackets and automatic air eliminator.Components7KEY PRODUCT PRODUCT CODE1Flow manifoldwith lockshieldvalves and flowR553Mmeter2Return manifoldwith built-in R553Vbalancing valves3AdjustablebracketsR588L4Standard portball valve with R259tail piece5 Pressure gauge R2256 Brass bush 010A028027Self-sealingend piece for R554Cmanifold8Self-sealingend piecefor manifold(return) withtemperaturegauge andautomatic airventR554DOVERALL DIMENsIONS.8PORTSHEIGHT(mm)LENGTH(mm)2 450 325 1103 450 375 1104 450 425 1105 450 475 1106 450 525 1107 450 575 1108 450 625 1109 450 675 11010 450 725 11011 450 775 11012 450 825 110DEPTH (mm)Including bracketR553(Manifold only)R553DM(Manifold Kit)T: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.ukPAGE: 21


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR HEATING & COOLINGMIXING MANIFOLDS1411376131052OVERALL DIMENsIONS.PORTSHEIGHT(mm)LENGTH(mm)2 450 515 1703 450 565 1704 450 615 1705 450 665 1706 450 740 170DEPTH (mm)Including bracketPORTSHEIGHT(mm)LENGTH(mm)7 450 790 1708 450 840 1709 450 890 17010 450 940 17011 450 990 17012 450 1040 170DEPTH (mm)Including bracketPAGE: 22T: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.uk


12Underfloor HEATING Mixing MANIFOLDS AREdesigned for use on high (85°C max) TEMPERATURECIRCUITS, which require blending down toLOWER UNDERFLOOR HEATING TEMPERATURE LEVELS.To be used when high temperature water is delivered to themanifold and needs to be mixed to the desired temperature.The R557MM kit includes pump, automatic air eliminator,brackets, flow meters, thermostatic mixing valve, lockshieldvalve, pressure & temperature gauge and differential by-pass.Components158914KEY PRODUCT PRODUCT CODE1Flow manifoldwith balancing R553Slockshield valves2Return manifoldwith built-in R553Vbalancing valves3AdjustablebracketsR588L4T with nut andtail pieceR557B5T with nut andtail pieceR557D6Isolating pumpvalveR2527Thermostaticheadtemperature R462Llimiting with 20÷ 70°C field8Self-sealingend piecefor manifold(return) withtemperatureR554Dgauge andautomatic airvent9Self-sealingend piece formanifold withautomaticR554Aair vent anddifferential valve10 Tail piece R557P11 Wilo pump WILO12 Pressure gauge R22513 Lockshield valve R15TG14Straightvalve withthermostaticR402TGoption15 Pipe adaptor R179R557(Manifold only)R557MM(Manifold Kit)T: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.ukPAGE: 23


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR HEATING & COOLINGMODULAR MANIFOLDS46STANDARd* DIMENsIONS.PORTSHEIGHT(mm)LENGTH(mm)2 450 300 1203 450 350 1204 450 400 1205 450 450 1206 450 525 1207 450 575 1208 450 625 1209 450 675 12010 450 725 12011 450 775 12012 450 825 120DEPTH (mm)Including bracket* Sizes shown are for guidance only. Dimensions of the modularmanifold may change due to the individual customer specifications.352PAGE: 24T: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.uk


78Giacomini’s UNDERFLOOR HEATING MODULARMANIFOLDS ARE DESIGNED FOR use with pre-BLENDED CIRCUITS which HAVE been SET to theLOW TEMPERATURES required for UNDERFLOORheating SYSTEMS.To be used when water temperature is controlled at theboiler (heat source), and sent to the manifold at the desiredwet underfloor heating temperature.Our modular manifold allows you design each manifold toyour own specifications.Comprised of individual components, Giacomini’s modularmanifold offers flexibility to extend or change the manifoldif necessary. Ensuring fast on-site alterations can be made.Modular manifolds also offer a flexible and cost effective wayto stock your underfloor heating system.Just click and twist to assemble.Required Components.1109KEY PRODUCT PRODUCT CODE1Pair of endmanifolds DN32, R53MTfor use on flow2Pair of endmanifold DN32, R53VTfor use on return3AdjustablebracketsR588L4Modularmanifolds DN32 R53MMfor use on flow5Modularmanifold DN32, R53VMfor use on return6Standard portball valve with R259tail piece7 Pressure gauge R2258 Brass bush 010A028029Self-sealingend piece for R554Cmanifold10Self-sealingend piecefor manifold(return) withtemperaturegauge andautomatic airventR554D2BaseComponentsAdditionalComponentsT: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.ukPAGE: 25


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR HEATING & COOLINGPIPEWORKAT <strong>GIACOMINI</strong> WE ARE PROUD TO BEABLE TO MANUFACTURE and supplyour OWN specialist PIPEWORK.All our pipework is manufactured in our dedicatedsynthetics factory covering 35,000m 2 , located in SanMaurizio d’Opaglio, Italy.Designed specifically for underfloor heating applications,Giacomini produces PE-X, Pb and PE-RT pipe in various coilsizes, suitable for all types of underfloor heating project.All pipework is equipped with an anti-oxygen barrier(BAO). This stops oxygen permeating through the pipewall, preventing the risk of corrosion of iron componentswithin the installation, such as boiler components.Due to the imperative role pipework plays within anunderfloor heating system, Giacomini has invested in highquality machinery and materials to ensure we achieve thehighest specification.Our pipe systems comply with all necessary EuropeanStandards:PE-X• BS 7291-3, EN ISO 15875 - Class 4,DIN 16892Pb• BS 7291-2 , EN ISO 15875 - Class 4, DIN 16968,DIN 16837PE-RT• BS 7291-1 , EN ISO 22391- Class 4, DIN 16833,DIN 16837Guaranteeing all our pipework has an operational lifetimeof at least 50 years.PAGE: 26T: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.uk


High DENSITY CROSS-linked POLYETHYLENE pipe withanti-oxygen (BAO) BARRIER.Available in 100m, 240m or 500m coils.Giacomini PE-X pipework offers many advantages compared tothe traditional copper or iron distribution.FEATURES:• High flexibility.• Rapid and easy installation.• Noticeable labour saving.• Enhanced durability and reliability (resultingin increased lifespan).• External anti-oxygen barrier in EVOH, incompliance with EN ISO 15875.• Reduced risk from encrustation orelectro-chemical problems.PE-XPB (POLYBUTYLENE) MULTI LAYER pipe with antioxygenBARRIER for HEATING, COOLING and domesticdistribution SYSTEMS.Available in 100m, 240m or 500m coils.FEATURES:• Lightweight. Polybutylene is approximately 9 timeslighter than iron and copper.• Reduced thermal expansion.• Very good resistance to shock and prolonged stress.• High material flexibility. This helps makes theinstallation quick and easy.• Intermediate anti-oxygen barrier made of EVOH.• Recyclable material.PE-RT (POLYETHYLENE) MULTI LAYER pipe with antioxygenBARRIER for warm WATER HEATING SYSTEMS.Available in 120m, 240m or 600m coils.FEATURES:• Enhanced thermal resistance.• Simple and rapid installation.• Noticeable labour saving.• High durability.• Increased strength.• Reduced risk from encrustation orelectro-chemical problems.• External anti-oxygen barrier in EVOH.PE-RT PBT: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.ukPAGE: 27


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR HEATING & COOLINGMaximum operating temperature 95°CSoftening temperature 130°CDensity 946 kg/m 3Degree of reticulation > 65%Resistance to 23°C traction20÷25 N/mm 2 (200÷250 bar)Lengthening at 23°C breaking 300÷500%Elasticity module at 23°C 1070 N/mm 2ResilienceNo breakingCoefficient of linear expansion at 20°C 1.4. 10-4 1/KCoefficient of linear expansion at 100°C 2.0. 10-4 1/KThermal conductivity of pipeλ = 0.35 W/mKLinear dispersion of sheathed pipe, laid in air.0.22 W/mKMin radius of curvature without pipe curving device5 · D estPE-XMaximum operating temperature 95°CSoftening temperature 113°CDensity 937 kg/m 3Yielding point17.6 N/mm 2 (176 bar)Breaking strength33.4 N/mm 2 (334 bar)Lengthening at breaking 280%Elasticity module 265 N/mm 2Weakening temperature-21°CMelting point124°C÷126°CCoefficient of thermal expansion 1.3. 10-4 1/KThermal conductivity of pipeλ = 0.22 W/mKFusion latent heat100 kJ/kgMin radius of curvature without pipe curving device5 · D estPBMaximum operating temperature 70°CSoftening temperature 123°CDensity 933 kg/m 3Yielding point16.7 N/mm 2 (167 bar)Breaking strength34.3 N/mm 2 (343 bar)Lengthening at breaking 800%Elasticity module 5600 N/mm 2Coefficient of thermal expansion 1.9. 10-4 1/KThermal conductivity of pipeλ = 0.40 W/mKMin radius of curvature without pipe curving device 5 · D est (per curve a 90°) 5 · 5 · D est (per curve a 180°)PE-RTPAGE: 28T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345


pipe dimensionsADDITIONAL COMPONENTSPRODUCT CODE DIAMETERWALLTHICKNESSCOILR996Y047 16 1.5 100 mR996Y048 16 1.5 240 mR996TY049 18 2 100 mR996TY020 18 2 240 mR996TY050 18 2 500 mPart No DescriptionPipe ClipsShort Clips 40 mmLong Clips 50 mmpipe dimensionsADDITIONAL COMPONENTSPRODUCT CODE DIAMETERWALLTHICKNESSCOILR986Y116 16 2 100 mR986Y117 16 2 240 mR986Y130 16 2 500 mPart NoClip railDescription1000 mmPart No DescriptionCompression Pipe CouplerR179X034 16 x 15 x 2 mmR179X076 18 x 16 x 1.8 mmR179X094 18 x 15 x 2 mmR179MX024 18 x 16 x 2 mmR179MX025 18 x 18 x 2 mmR179MX026 18 x 20 x 2 mmR179MX034 18 x 17 x 2 mmpipe dimensionsWALLPRODUCT CODE DIAMETER THICKNESSCOILR978Y234 17 2 120 mR978Y235 17 2 240 mR978Y237 17 2 600 mADDITIONAL COMPONENTSPart No DescriptionBlack Pipe ConduitR985NY001 25 x 20 mm(100m coil)T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345PAGE: 29


1.<strong>GIACOMINI</strong>3.4.2.DANFOSS5.6.BATTERYPOWERED HARDWIRED WIRELESSFROSTPROTECTION1 <strong>GIACOMINI</strong> - K494AY001 - DIGITAL ELECTRONIC THERMOSTAT • • •2 DANFOSS - RMT 230 L - MECHANICAL THERMOSTAT •3 DANFOSS - RET 230P - TAMPERPROOF THERMOSTAT •4 DANFOSS - TP5000si - PROGRAMMABLE THERMOSTAT • (Available) (BELOW) •5 DANFOSS - TP5000RF SI + RX1 - WIRELESS PROGRAMMABLE THERMOSTAT • • •6 DANFOSS - CF2 RD - WIRELESS ROOM THERMOSTAT • •7 HEATMISER - PRT-NTS - NETWORK PROGRAMMABLE THERMOSTAT • • (Available) •8OJ ELECTRONICS - WLTM-19 & SENSOR PLATE -TAMPERPROOF / anti-LIGATURE SENSOR AND CONTROL • • • •PAGE: 30T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345


7.HEATMISEROur expert <strong>UFH</strong> system designers havehandpicked a RANGE of CONTROLS to ensureour CUSTOMERS are offered a COMPREHENSIVErange of designs and FEATURES.Single areas of underfloor heating can be effectivelycontrolled by means of a room thermostat. This controlcan be further enhanced by using a programmable roomthermostat to provide both time and temperature control.Many programmable thermostats now have additionalcontrol features, such as night set back and optimum start,which can be utilised with underfloor heating systems.Individual rooms fed from the same manifold can becontrolled by means of room thermostats. When multipleroom control is required, the room thermostats can bewired through a Giacomini control centre (PM100).<strong>GIACOMINI</strong> RECOMMENDS:LOCATION KEY PRODUCT CODE8.OJ ELECTRONICS• LARGE COMMERCIAL• APARTMENT BLOCKS• HOUSING DEVELOPMENT• SCHOOLS• PUBLIC AREAS1, 23K494AY001RMT 230 LRET 230 P• SMALL DOMESTIC4TP5000si• CARE HOMES• SEN FACILITIES• PRISONS8WLTM-19 &SENSOR PLATE• LUXURY HOME• HIGH PERFORMANCE7PRT-NTS• RETROFIT56TP5000RF SI + RX1CF2 RDDIGITALDISPLAYMANUALCOSTEFFECTIVETAMPERPROOFFLOOR PROBECOMPATIBLESLIMLINEDESIGNPROGRAMMABLEOPTIMUMSTARTNIGHT SETBACK• • • • 1• • 2• • • • 3• •(LOCKABLEELECTRONICALLY) • • • • 4• • • • • • 5• (PUSH BUTTON) • •(WITH CFRCREMOTE) 6• • • • • 7• • (WLTD-19) •8T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345PAGE: 31


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR HEATINGPM100W1243FIG.APAGE: 32T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345


PM100W - 230v 8 Zone UNDERFLOOR HEATINGWiring CentreThe PM100W is designed to control heating installationswhere temperature control is made by room thermostats,which operate electric actuators controlling water supply toindividual circuits.This 230v wiring centre is for use with mixing or distributionmanifolds allowing you to control up to 8 individualthermostats.The unit contains a control relay with time delay for the <strong>UFH</strong>circulating pump and a relay for switching external controls.Time switches with volt free contacts can be connected tothe unit.The PM100W offers many benefits to the final users, such as:• Deactivation of the circulating pump when all electricalactuators are in the off-position. Avoiding energy wastageand unnecessary wear on the circulating pump.• Activation of the circulating pump, with a 4 minutes delay,from the moment a thermostat requires the opening ofthe electrical actuators. This relay guarantees the completeopening of the linked hydraulic circuits.• Constant monitoring of the supply and deactivation of thecirculation pump, when the pre-set temperature limit hasbeen exceeded for more than 4 minutes. This avoids repeatignition and shutdown of the system, which can have afuture impact on the temperature regulation of the mixervalve.FIG.B• Allows control of supplementary heating elements (e.g.boiler) with auxiliary connections.• Daily or weekly event program (connecting a time clock ora time switch).• Night set back function (connecting a time switch).• The status of each 230v electrical actuator (normally closed)is indicated using LED signals.• Direct installation of the product on the wall with protectivecasing.FIG.AKEY SIGNAL STATUSFIG.c12Activation ofthe electricalactuators.Activation ofthe time switch.Supplytemperaturealarm.Supplytemperaturesignal.A red light is shown when itscorresponding zone (1-8) iscalling for heat (via the roomthermostat).Time switch is positive.3High limit exceeded. Pumpand boiler will switch off after4.5 minutes.4Water temperature withinlimit.T: 01454 311012 E: enquiries@giacomini.co.uk F: 01454 316345PAGE: 33


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR HEATING & COOLINGTECHNICAL SUPPORTCOMMISSIONINGCommissioning an underfloor heating systemis vital in ensuring that all of the system andcomponents are running effectively andoperating according to its design specificationsand building regulations.Giacomini’s engineers check, inspect and testevery operational component. Beginning withtheir individual functions, and finishing withreviewing their amalgamation into the systemas a whole. This will ensure maximum heatperformance from the system.All <strong>GIACOMINI</strong> PRODUCTS and SERVICES aresupported BY our COMPREHENSIVE technicalADVISORY SERVICE.Our technical engineers are ready to offer you advice and guidanceon all aspects of application, design and installation across the entirerange of Giacomini products and services.All of our technical advisors have been hand-picked for their breadthof knowledge and sector experience.Our technical service includes:• Allocation of a dedicated technical sales engineer.• Comprehensive library of documents.• Technical drawings and schematics.• Technical calculations.• Detailed product specification.• Full CAD design service.During installation, you will have your own dedicated project managerwho will oversee all aspects of your underfloor heating project.Giacomini’s approved service engineers are also available for all sitebased queries.To speak to one of our technical advisors:Email: support@giacomini.co.ukCall us on: 01454 311012Commissioning should always be consideredduring the planning stage to avoid any potentialissues arising further down the constructionschedule.Giacomini’s <strong>UFH</strong> engineers have been trained tospot all possible faults within a system.Common issues are:• Increased floor temperatures.• Decreased room temperatures.• Loss in pressure.• Temperature differentials.• High energy consumption.Commissioning can be completed once thefollowing steps have been taken:• The screed (if applicable) is cured.• The system is clean and flushed.• The system has been filled and vented.• The controls have been wired.Using a Giacomini engineer to commission yoursystem guarantees a safe and orderly handover ofthe unit. Our commission certificate is assurancethat your underfloor heating system operateswith maximum performance, reliability and withfull health and safety checks.FIND YOur REPRESENTATIVEWe have Giacomini representatives based all over the UK who arethere to help you find the right product to suit your needs.All Giacomini representives have in-depth technical knowledge of ourproducts and systems, and look forward to discussing your projectrequirements.To find a representative in your area:Please scan the adjacent QR CodeOr visit: www.giacomini.co.uk/contact-us-reps.aspPAGE: 34T: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.uk


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR UNDERFLOOR HEATING HEATING FAQ’S1 9How do I CONNECT my UNDERFLOOR HEATINGsystem TO the boiler?The underfloor heating system should be connected to theboiler through the manifold. The manifold controls the heatrequirement for the underfloor system by blending hot waterfrom the boiler with cooler returned water from the floorcircuits. Most boilers have a high output temperature (80-85°C)to cater for the other heat requirements of the dwelling (e.g.hot water cylinder, radiators and towel rails), which meansthat they should not be connected directly to the underfloorsystem.Why do I need ANOTHER pump on the manifold?The pump circulates the water within the underfloor heatingsystem and will continue to operate after the injector valve hasclosed and hot water is no longer being mixed with the returnwater. It is also required where the pump on the boiler wouldnot achieve the required flow rates in the system. Please note:Pumps are only required on mixing manifolds (for use on hightemperature circuits, which require blending down).Where should the manifold be positioned?The manifold can be positioned virtually anywhere in thebuilding, as long as there is enough heat output to supply thedemand. However it is preferable to site the manifold centrallyin the building to ensure pipe runs to circuits are kept to aminimum.Will PUTTING CARPET OVER the UNDERFLOORheating HAVE an EFFECT on it?Yes, carpet will slow the heat transmission down because of itsthermal resistance. However this should not significantly affectthe overall performance of the system. It is important thatcarpeting is specified as a requirement during the design of thesystem and that the correct underlay is fitted; this preferablyshould have a tog rating of less than 1.Will underfloor heating WORK withLAMINATE FLOORING?Yes, however care should be taken when selecting laminateunderlay. The manufacturer’s advice should be soughtregarding suitability for use with underfloor heating, as somelaminate underlays are highly insulating.Can UNDERFLOOR HEATING be INSTALLED on apressurised sealed SYSTEM?Yes, it can be installed on any sealed or open vented typesystem.How LONG does UNDERFLOOR HEATING taketo WORK?Normally from cold, a typical solid floor system will take 3-5hours to reach temperature. However when the system isoperational, it will only lose on average 4°C in an 8 hour period,therefore it will only take a couple of hours to reach operatingtemperature in normal operation.What type and thickness of FLOORINSULATION should be used?Any board type of insulation can be used. However the foiledhigh-density polyurethane foam is likely to suffer less sitedamage due to the high compressive strength. Pipe fixingstaples also hold very firmly into this type of insulation. Thethickness of insulation required is calculated to achieve aU-value of 0.25, which is the minimum permitted by theBuilding Regulations. Insulation thickness will therefore bedifferent for every building and should be calculated whendesigning the building.What type of screed do I use?In most cases normal sharp sand and cement mix can be usedfor a standard 75mm screed. If the screed is to be less than75mm other options should be considered. Advice should besought from a screed manufacturer as additives and fibres canbe added for additional strength and flexibility. For very thinscreeds a special mix is required, however there is a possibilitythat the floor temperature will not be even, with warm stripsabove the pipe centres.Do I need to add a PLASTICIZER to the screedmix?2 10345678No, however it is important when screeding an underfloorheating system that the screed envelopes the pipe fully for it towork to its full potential. Screed is normally installed very dry;therefore care must be taken to avoid air pockets around the<strong>UFH</strong> pipe. Adding a plasticizer to the mix can help the screedflow better, thereby avoiding air pockets. Screed as a wet mixshould be avoided because this can cause shrinkage andcracking when drying out. It is advisable to seek expert advicefrom a screed manufacturer.What is the edge INSULATION strip for?Edge insulation strip serves two purposes. Firstly it forms aninsulation barrier around the floor slab and therefore preventsheat loss to surrounding walls. Secondly, it acts to fill theexpansion gap around the slab, allowing the floor to expandand contract as it warms up and cools down.What is the CONDUIT used for?On screeded installations the conduit is installed over theunderfloor heating pipes, where they cross into adjoiningrooms (generally at doorways). This is important because if aroom is heated and an adjacent room is not, the floors expandin different directions and the pipe passing through thedoorway could be damaged. The conduit pipe can also be usedto reduce heat loss in the transit portion of pipework (sectionof pipe from manifold to heated room) or when pipe passesthrough an area that is not to be heated (under kitchen units).What pipe SPACING should I use?Giacomini underfloor heating systems can be individuallydesigned. Please refer to your design data sheet or call ourdesign office.How is the SYSTEM CONTROLLED?Usually, electrical actuator heads are fitted to each underfloorheating pipe circuit. These actuators are controlled either bya central thermostat or individual room thermostats, linkedtogether with a time clock through a wiring centre. A weathercompensation circuit may also be incorporated in the systemto adjust for outside temperature variations. The system canalso be controlled via a BMS (Building Management System).How much WATER will there be in anunderfloor HEATING SYSTEM?An 18mm pipe will contain 0.154 litres per linear metre of pipe.In addition there will be an amount of water in the manifoldand pump.Can I put a manifold in the FLOOR and feedup?Yes, but it is not recommended as air locks may occur.Can CORROSION INHIBITORS be used in thesystem?Yes, Giacomini recommend the use of corrosion inhibitors suchas Sentinel 100 or Fernox MB in all systems. Advice should besought from the inhibitor manufacturer to check compatibility.11121314151617T: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.ukPAGE: 35


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR HEATING & COOLINGAccreditationSAccreditationSUNDERFLOOR HEATING ACCREDITATIONSUNDERFLOOR HEATING GuaranteeSGiacomini UK is the only provider of underfloor heatingoffering a complete package from manufacture and designthrough to installation and commissioning, with the addedreassurance of our unique 10 year system guarantee.Our project specific 10-year system guarantee promises thatour pipework, manifolds and installation will be free of defectsfor the guarantee period. Excluding electrical controls andpumps, which are guaranteed for two years.With so many elements being taken care of in-house by ourgrowing team of project managers, engineers, designers andinstallers, all our <strong>UFH</strong> system guarantees are given with greatconfidence.We are also proud to be able to offer all our customers themost comprehensive range component guarantees, covering:• Pipework (50 years)• Brass (10 years)• Electronic controls & pumps (2 years)As Giacomini is in the unique position to be able tomanufacturer all of its underfloor heating components, we areable to guarantee you a permanent supply of spare parts. Thisguarantees the end user the ability to update or amend their<strong>UFH</strong> system if ever required.Giacomini systems include a consequential loss policy up tothe value of £2.1 million per project.PAGE: 36T: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.uk


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR HEATINGThe Giacomini range is comprehensive and includes:• Underfloor Heating Components• Underfloor Heating Design• Underfloor Heating InstallationFor further information about Giacomini’s productsand services please contact us:Tel:01454 311012Fax:01454 316345• Radiator Valves• Gate Valves• Lever Ball ValvesEmail:enquiries@giacomini.co.ukWeb:www.giacomini.co.uk• Fire Protection Valves • Sanitary Manifolds• Automatic Air Vents • Heat Interface Units• Filling & Safety Valves • Hydrogen BoilersGiacomini U.K. LtdUnit 2, Goodrich Close,Westerleigh Business Park, Yate,South Gloucestershire, BS37 5YT.CONTACT US PRODUCT RANGEThis communication is merely for information purposes. GiacominiU.K, Ltd. retains the right to make modifications for technical orcommercial reasons, without prior notice, to the items describedin this communication. The information described in this technicalcommunication does not exempt the user from following carefully theexisting regulations and norms on good workmanship.T: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.uk


<strong>GIACOMINI</strong> U.K. LTDUNDERFLOOR HEATINGPLEASE DO NOT HESITATE TO CONTACT USWITH ANY QUESTIONS OR ENQUIRIESGiacomini U.K. LtdUnit 2, Goodrich Close, Westerleigh Business ParkYate, South Gloucestershire, BS37 5YT.Tel: 01454 311012 - Fax : 01454 316345enquiries@giacomini.co.uk - www.giacomini.co.ukT: 01454 311012 E: enquiries@giacomini.co.uk W: www.giacomini.co.uk

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!