12.07.2015 Views

Frequency Converters and Associated Products. Sept 2012.pdf

Frequency Converters and Associated Products. Sept 2012.pdf

Frequency Converters and Associated Products. Sept 2012.pdf

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Analog & Digital RF-SolutionsSATCOMTechnologies09/2012SatelliteIF Up-/Down-<strong>Converters</strong>SatelliteBlock<strong>Converters</strong>RedundancySwitches1:1 / N:1<strong>and</strong> moreVolume 1


Table of ContentsPageSatellite Up- <strong>and</strong> Downconverter .......................................................................................... 3Satellite Up- <strong>and</strong> Downconverter, Outdoor Version .......................................................... 13Dual Channel, Shared Oscillator ........................................................................................ 19Downconverter ..................................................................................................................... 19Inmarsat Downconverter ..................................................................................................... 22Narrowb<strong>and</strong> Downconverter ............................................................................................... 22L-B<strong>and</strong> to 70/140 MHz .......................................................................................................... 22Synthesized Block Up- <strong>and</strong> Downconverter ...................................................................... 27Synthesized Block Up- <strong>and</strong> Downconverter Outdoor Version ......................................... 34L-B<strong>and</strong> Block Upconverter .................................................................................................. 38L-B<strong>and</strong> Block Downconverter ............................................................................................. 41Narrowb<strong>and</strong> Block Downconverter .................................................................................... 44Satellite Block-Upconverter (mini-buc).............................................................................. 45Block-Converter Reference Module ................................................................................... 49Remote Control Unit ............................................................................................................ 50Satellite Uplink Power Control Unit .................................................................................... 50Automatic Level Control (ALC) Filter Amplifier ................................................................. 52Automatic Level Control (ALC) Filter Amplifier ................................................................. 53Redundancy Switch 1:1 ....................................................................................................... 55Redundancy Switch 1:1 for IP Modems ............................................................................. 59Compact Redundancy Switch 2:1 ...................................................................................... 62Modular Redundancy Switch N:1 ....................................................................................... 63Outdoor Housings ............................................................................................................... 67Cover picture with kind permission of Eutelsat


Visit us at www.work-microwave.deSatellite Up- <strong>and</strong> DownconverterSingle / Dual / Triple B<strong>and</strong>Single / Dual ChannelS-, C-, X-, Ku-, K(DBS)-, Ka-B<strong>and</strong>The satellite up- <strong>and</strong> downconverters which aredeveloped <strong>and</strong> manufactured by WORK Microwave,are designed to satisfy the high requirements ofmodern satellite transmission, such as TV uplinks <strong>and</strong>high speed data networks. Analogue transmissionformats are supported as well as digital transmissionformats. For many years, these devices have beenused worldwide for fixed satellite earth stations,satellite news gathering (SNG) vehicles <strong>and</strong> othermobile or portable applications. The up-<strong>and</strong> downconvertershave been produced more than 1200 timesso far <strong>and</strong> customers worldwide appreciate theirreliability <strong>and</strong> high level of quality.4th Generation – still betterThe 4 th generation, based on our experience <strong>and</strong> skill,is still better. The synthesizer <strong>and</strong> oscillator portion inevery satellite converter is the most importantcomponent because it decides the converter'sreliability. For many years WORK Microwave hasbeen developing <strong>and</strong> manufacturing highsophisticated microwave oscillators <strong>and</strong> synthesizers,which are used in our converter series as well. Thenew design allows us to reduce the number ofcomponents by more than 30%. In addition, significantimprovements have been made on circuit design.This design results in an AC power consumption oftypically 35 VA / 23 W. This leads to an even higherreliability <strong>and</strong> longer life time.S-, C-, X-, Ku-, K <strong>and</strong> Ka-B<strong>and</strong> coverageThe satellite converter series cover the satellitefrequency b<strong>and</strong>s S-, C-, X-, Ku-, K- <strong>and</strong> Ka-B<strong>and</strong>. Theconverters support the st<strong>and</strong>ard IF-frequency b<strong>and</strong>s70 ± 20 MHz <strong>and</strong>/or 140 ± 40 MHz. The conversion isperformed without spectral inversion. Theupconverters offer an increased power output(P 1dB ≥ +10 dBm) in all versions. The units areavailable as single b<strong>and</strong>, dual b<strong>and</strong> or as triple b<strong>and</strong>converters (see also next page under “Specials <strong>and</strong>OEM products).High signal integrityThe extreme low phase noise of the oscillatorsguarantees an excellent signal quality. Low spuriousemissions allow our customers to use the convertersalso in the environments with dem<strong>and</strong>ingrequirements, such as high power video uplinks.Sophisticated temperature compensation guaranteesthe stability over a very wide temperature range.Housing optionsThe converters normally are delivered without fans<strong>and</strong> can be operated in environments, where atminimum 1 RU space for natural ventilation isavailable above each unit. This eliminates the fan aspotential point of failure. For rack installations withoutany space in between the units a fan within theconverter unit is recommended, which forces anairflow from the right side to left side of the units.2012-09-173


dBc/HzOperating <strong>and</strong> control – easy integrationinto your systemThe converters can be operated via the push buttonson the front panel using self-explanatory displaymenus or via remote control (RS232, RS422/485,TCP/IP over Ethernet). Detailed monitoring of thesystem status <strong>and</strong> a summary alarm output (dualchange over switch contacts) are provided. For theremote control either ASCII string based comm<strong>and</strong>sas well as addressable, packet based comm<strong>and</strong>s areprovided.Remote monitoring <strong>and</strong> control through SNMP <strong>and</strong> aWeb browser interface is also available.-50-60-70-80-90-100-110Phase Noise Performance of Up- <strong>and</strong>Downconverters-12010 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 10 MHzCustomized products<strong>Frequency</strong>In addition to st<strong>and</strong>ard products WORK Microwaveoffers custom tailored products <strong>and</strong> specializedproducts as follows:Modified or smaller housings to fit into yourexisting design for mobile <strong>and</strong> portableapplications.Extended storage or operating temperature range.Military versions for hostile environment (shock,vibration, humidity).For downconverters: Application specific outputfiltering <strong>and</strong> automatic level control. The outputlevel is kept constant independent of the strengthof the input signal with adjustable control.Additional PLO output.Key features70 MHz or 140 MHz IF b<strong>and</strong>s availableOptional switchable IF 70 MHz <strong>and</strong> 140 MHz(IF 70/140)Extreme low power consumption maximum38 VA / 25 W (single b<strong>and</strong> unit) 40 VA / 27 W(triple b<strong>and</strong> units)Extreme low phase noise (< -50 dBc/Hz @ 10 Hz)Long- term stability 10 -7 / yearOutput power +10 dBm (1 dB compression point)Low spurious emissions < -80 dBm at full gain(high performance series)Automatic reference recognition (5 <strong>and</strong> 10 MHz)Adjustable gain equalizerDigital gain compensationOperating temperature range either -30°C to 60°C(-22°F to 140°F) or 0°C to 50°C (32°F to 122°F)Remote control through RS232, RS422/485(2-wire or 4-wire) interfaces. Packet comm<strong>and</strong>syntax supports RS485 bus systems <strong>and</strong> allowsaddressed operation.Remote control through Ethernet supporting aTCP/IP comm<strong>and</strong> interface, a Web browserinterface <strong>and</strong> SNMP (MIBs are provided).Test output on the front panel: RF-Test atupconverter, IF-Test at downconverter.Optional IF-Test output for upconverters on rearpanel (Option: IFT)AC power switch on the front panelSummary alarm output (dual change over switchcontacts)Transmit mute inputOptional internal Fan (Option: FAN)CE compliant3 years warrantyOrder informationWORK Microwave offers two series of 19” rack mountsatellite converters, St<strong>and</strong>ard <strong>and</strong> High Performance.The specifications are the same for both types exceptthe operating temperature range. The HighPerformance type operates between -30°C to 60°C(-22°F to 140°F) <strong>and</strong> the St<strong>and</strong>ard type between 0°Cto 50°C (32°F to 122°F). So if you only need units forinside use, the st<strong>and</strong>ard unit is perfectly suited for thisapplication.Open questions, demo unitsIf you need more information about WORKMicrowave’s 4 th satellite converter generation or if youwould like to have demo unit, please contact us via e-mail: sales@work-microwave.de or call us. We areglad to assist you.4 2012-09-17


Satellite UpconverterIndoor VersionSingle / Dual / Triple B<strong>and</strong> Upconverter or Dual Channel UpconverterS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Upconverter Type: HCU-S / SCU-S HCU-S4 / SCU-S4 HCU-C / SCU-C HCU-C1 / SCU-C1RF-Output <strong>Frequency</strong>:Intermediate <strong>Frequency</strong>:Phase Noise:Test Output:(Fixed Oscillator)Test Output:(Microwave Oscillator)10 Hz100 Hz1 kHz10 kHz100 kHz1 MHzS-B<strong>and</strong>2.025…2.290 GHz2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF InputS-B<strong>and</strong>2.0…2.6 GHz3050 MHzfor 70 MHz IF Input3040 MHzfor 140 MHz IF InputC-B<strong>and</strong>5.85…6.65 GHz2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF InputC-B<strong>and</strong>5.85…7.03 GHz2610 MHzfor 70 MHz IF Input2600 MHzfor 140 MHz IF Input-60-80-90-98-103 1)-112 1) -60-80-90-98-103 1)-112 1) -55-75-85-95-100 1)-110 1)) -55-75-85-95-100 1)-110 1)max. values in dBc/ Hz1)0°C ... 50°C, outside this temperature range degraded by max 5 dB.2520 MHz (70 MHz IF)2580 MHz (140 MHz IF)-6 ± 3 dBmSMA female4.475…4.740 GHz(70 MHz IF)4.465…4.730 GHz(140 MHz IF)- 7 ± 3 dBmSMA female3120 MHz (70 MHz IF)3160 MHz (140 MHz IF)-6 ± 3 dBmSMA female5.05…5.65 GHz(70 MHz IF)5.04…5.64 GHz(140 MHz IF)- 7 ± 3 dBmSMA female2520 MHz (70 MHz IF)2580 MHz (140 MHz IF)-6 ± 3 dBmSMA female8.30…9.10 GHz(70 MHz IF)8.29…9.09 GHz(140 MHz IF)- 7 ± 3 dBm 2)SMA female2680 MHz (70 MHz IF)2740 MHz (140 MHz IF)-6 ± 3 dBmSMA female8.46…9.64 GHz(70 MHz IF)8.45…9.63 GHz(140 MHz IF)- 7 ± 3 dBm 2)SMA femaleUpconverter Type: HCU-X HCU-Ku / SCU-Ku HCU-Ku2 / SCU-Ku2 HCU-K / SCU-KRF-Output <strong>Frequency</strong>:Intermediate <strong>Frequency</strong>:Phase Noise:Test Output:(Fixed Oscillator)Test Output:(Microwave Oscillator)10 Hz100 Hz1 kHz10 kHz100 kHz1 MHzX-B<strong>and</strong>7.90…8.40 GHz2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF InputKu-B<strong>and</strong>12.75…14.50 GHz2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF InputKu-B<strong>and</strong>11.80…13.40 GHz2300 MHzfor 70 MHz IF Input2270 MHzfor 140 MHz IF InputK-B<strong>and</strong>17.3…18.4 GHz2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF Input-53-73-83-93-98 1)-108 1) -50-70-80-90-95 1)-105 1) -50-70-80-90-95 1)-105 1) -50-70-80-90-95 1)-105 1)max. values in dBc/ Hz1)0°C ... 50°C, outside this temperature range degraded by max 5 dB.2520 MHz (70 MHz IF)2580 MHz (140 MHz IF)-6 ± 3 dBmSMA female10.35…10.85 GHz(70 MHz IF)10.34…10.84 GHz(140 MHz IF)- 7 ± 3 dBm 2)SMA female2520 MHz (70 MHz IF)2580 MHz (140 MHz IF)-6 ± 3 dBmSMA female15.20…16.95 GHz(70 MHz IF)15.19…16.94 GHz(140 MHz IF)- 7 ± 3 dBm 2)SMA female2370 MHz (70 MHz IF)2410 MHz (140 MHz IF)-6 ± 3 dBmSMA female14.1…15.7 GHz(70 MHz IF)14.07…15.67 GHz(140 MHz IF)- 7 ± 3 dBm 2)SMA female2380 MHz (70 MHz IF)2300 MHz (140MHzIF)-6 ± 3 dBmSMA female14.85…15.95 GHz(70 MHz IF)15.86…15.96 GHz(140 MHz IF)- 7 ± 3 dBm 2)SMA femaleSpecifications continued next page2)-12 ± 3 dBm for Dual-B<strong>and</strong> units <strong>and</strong> Triple-B<strong>and</strong> units e.g. HCU3-CXKu, HCU3-CKuK2012-09-175


Satellite UpconverterIndoor VersionSingle / Dual / Triple B<strong>and</strong> Upconverter or Dual Channel UpconverterS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Specifications continued:Upconverter Type: HCU-Ka / SCU-Ka HCU-Ka1 / SCU-Ka1 HCU-Ka3-2 / SCU-Ka3-2 HCU-Ka4 / SCU-Ka4RF-Output <strong>Frequency</strong>:Ka-B<strong>and</strong>29.7…31.5 GHzKa-B<strong>and</strong>19.2…20.2 GHzKa-B<strong>and</strong>17.7…19.5 GHz19.4…21.2 GHz(automatically switched)Ka-B<strong>and</strong>27.5…31 GHzIntermediate <strong>Frequency</strong>:Phase Noise:Test Output:(Fixed Oscillator)Test Output:(Microwave Oscillator)10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF Input2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF Input2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF Input5170 MHzfor 70 MHz IF Input5100 MHzfor 140 MHz IF Input-46-66-76-86-88 1)-101 1) -50-70-80-90-95 1)-105 1) -50-70-80-90-95 1)-105 1) -46-66-76-86-88 1)-101 1)max. values in dBc/ Hz1)0°C ... 50°C, outside this temperature range degraded by max 5 dB.2380 MHz (70 MHz IF)2300 MHz (140MHzIF)-6 ± 3 dBmSMA female27.25…29.05 GHz(70 MHz IF)27.26…29.06 GHz(140 MHz IF)- 10 ± 3 dBmSMA female2380 MHz (70 MHz IF)2300 MHz (140MHzIF)-6 ± 3 dBmSMA female16.75…17.75 GHz(70 MHz IF)16.76…17.76 GHz(140 MHz IF)- 7 ± 3 dBmSMA female2380 MHz (70 MHz IF)2300 MHz (140MHzIF)-6 ± 3 dBmSMA female15.25…18.75 GHz(70 MHz IF)15.26…18.76 GHz(140 MHz IF)- 7 ± 3 dBmSMA female5240 MHz (70 MHz IF)5240 MHz (140MHzIF)-6 ± 3 dBmSMA female16.335…18.085 GHz(70 MHz IF)16.335…18.085 GHz(140 MHz IF)- 7 ± 3 dBmSMA femaleUpconverter Type:RF-Output <strong>Frequency</strong>:Intermediate <strong>Frequency</strong>:Phase Noise:Test Output:(Fixed Oscillator)Test Output:(Microwave Oscillator)10 Hz100 Hz1 kHz10 kHz100 kHz1 MHzHCU-Ka8 / SCU-Ka8Ka-B<strong>and</strong>22.55…23.15 GHz2150 MHzfor 70 MHz IF Input2140 MHzfor 140 MHz IF Input t-46-66-76-86-88 1)-101 1)max. values in dBc/ Hz2080 MHz (70 MHz IF)2000 MHz (140MHzIF)-6 ± 3 dBmSMA female10.2…10.5 GHz(70 MHz IF)10.205…10.505 GHz(140 MHz IF)- 7 ± 3 dBmSMA female1)0°C ... 50°C, outside this temperature range degraded by max 5 dB.Specifications continued next page6 2012-09-17


Satellite UpconverterIndoor VersionSingle / Dual / Triple B<strong>and</strong> Upconverter or Dual Channel UpconverterS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Specifications continued:Conversion Scheme:<strong>Frequency</strong> Resolution:IF-Input Characteristics:RF-Output Characteristics:Transfer Characteristics:Equalizer (Gain Slope):Group Delay (± 18 MHz):Group Delay (± 36 MHz):Intermodulation (3 rd Order):AM / PM conversion:Spurious Outputs:Dual up-conversion, no frequency inversion10 Hz<strong>Frequency</strong>:Impedance:Return Loss:IF-Connectors:Impedance:Return Loss:1 dB Compression Point:Output Muting:RF-Signal Monitor:RF-Connectors:Max. Conversion Gain:Attenuation Range:Gain Accuracy:Level Stability:Amplitude Response:Image Rejection:Noise Figure:max ± 2.5 dB / 40 MHz (IF 70 MHz),max ± 4 dB / 80 MHz (IF 140 MHz) (programmable)Linear:Parabolic:Ripple:Linear:Parabolic:Ripple:70 ± 20 MHz or 140 ± 40 MHz (optional: both [IF-B<strong>and</strong>] = 70/140)50 or 75>20 dBBNC female50>20 dB (>17 dB HCU3-CKuK)>10 dBm>60 dB (by comm<strong>and</strong> or sense input or by alarm condition)-20 dB of RF-output (approx.)SMA female (St<strong>and</strong>ard)K female (RF output >18 GHz)40 dB0…30 dB, Step 0.1 dB (Conversion Gain 40…10 dB)± 1 dB± 0.25 dB/day (constant temperature)±0.2 dB / ± 18 MHz, ± 0.25 dB / ±20 MHz, ±0.4 dB / ± 40 MHz>80 dB


Satellite UpconverterIndoor VersionSingle / Dual / Triple B<strong>and</strong> Upconverter or Dual Channel UpconverterS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Order Information: HCU-[RF B<strong>and</strong>(s)]-[IF B<strong>and</strong> in MHz]-[IF Imp in Ω]-[Options] Single or Dual converterHCUx-[RF B<strong>and</strong>(s)]-[IF B<strong>and</strong> in MHz]-[IF Imp in Ω]-[Options] Multib<strong>and</strong> converterSCU-[RF B<strong>and</strong>(s)]-[IF B<strong>and</strong> in MHz]-[IF Imp in Ω]-[Options] Single or Dual converterSCUx-[RF B<strong>and</strong>(s)]-[IF B<strong>and</strong> in MHz]-[IF Imp in Ω]-[Options] Multib<strong>and</strong> converterx=2: Dualb<strong>and</strong> converter, x=3: Tripleb<strong>and</strong> converterPossible Options are:Examples:FAN (internal Fan)IFT (additional IF test output)VFD (VFD display, st<strong>and</strong>ard with HCU-type converters)HCU-C-70-50 (C-b<strong>and</strong> upconverter)SCU-Ku-140-75-FAN (Ku-b<strong>and</strong> upconverter with internal Fan)HCU-C-70/140-50 (C-B<strong>and</strong> upconverter dual IF 70 <strong>and</strong> 140 MHz)HCU3-CXKu-70-50 (Tripleb<strong>and</strong> upconverter)SCU-CKu-70-75 (Dual channel upconverter C-b<strong>and</strong> <strong>and</strong> Ku-b<strong>and</strong>, identical IF <strong>and</strong> impedance)SCU-C-70-75/Ku-140-50-FAN (Dual channel upconverter C-b<strong>and</strong> <strong>and</strong> Ku-b<strong>and</strong> with Fan,different IF <strong>and</strong> impedance)8 2012-09-17


Satellite DownconverterIndoor VersionSingle / Dual / Triple B<strong>and</strong> Downconverter or Dual Channel DownconverterS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Downconverter Type: HCD-S / SCD-S HCD-S4 / SCD-S4 HCD-C / SCD-C HCD-C1 / SCD-C1RF-Input <strong>Frequency</strong>:Intermediate <strong>Frequency</strong>:Phase Noise:Test Output(Fixed Oscillator):Test Output(Microwave Oscillator):10 Hz100 Hz1 kHz10 kHz100 kHz1 MHzS-B<strong>and</strong>2.025…2.290 GHz**2450 MHzfor 70 MHz IF Output2440 MHzfor 140 MHz IF OutputS-B<strong>and</strong>2.0…2.6 GHz3050 MHzfor 70 MHz IF Input3040 MHzfor 140 MHz IF InputC-B<strong>and</strong>3.4…4.2 GHz2150 MHzfor 70 MHz IF Output2140 MHzfor 140 MHz IF OutputC-B<strong>and</strong>3.4…4.8 GHz2150 MHzfor 70 MHz IF Output2140 MHzfor 140 MHz IF Output-60-80-90-98-103 1)-112 1) -60-80-90-98-103 1)-112 1) -56-76-86-96-101 1)-111 1) -53-73-83-93-98 1)-108 1)max. values in dBc/ Hz1)0°C ... 50°C, outside this temperature range degraded by max 5 dB.2520 MHz (70 MHz IF)2580 MHz (140 MHz IF)-6 ± 3 dBm, ConnectorSMA female4.475…4.74 GHz(70 MHz IF)4.465…4.73 GHz(140 MHz IF)-7 ± 3 dBmSMA female3120 MHz (70 MHz IF)3160 MHz (140 MHz IF)-6 ± 3 dBmSMA female5.05…5.65 GHz(70 MHz IF)5.04…5.64 GHz(140 MHz IF)- 7 ± 3 dBmSMA female2220 MHz (70 MHz IF)2280 MHz (140 MHz IF)-6 ± 3 dBm, ConnectorSMA female5.55…6.35 GHz(70 MHz IF)5.54…6.34 GHz(140 MHz IF)-7 ± 3 dBm 2)SMA female2220 MHz (70 MHz IF)2280 MHz (140 MHz IF)-6 ± 3 dBm, ConnectorSMA female5.55…6.95 GHz(70 MHz IF)5.54…6.94 GHz(140 MHz IF)-7 ± 3 dBm 2)SMA femaleDownconverter Type: HCD-X HCD-Ku / SCD-Ku HCD-Ku4 / SCD-Ku4RF-Input <strong>Frequency</strong>:X-B<strong>and</strong>Ku-B<strong>and</strong>Ku-B<strong>and</strong>7.25…7.75 GHz10.70…12.75 GHz9.3…9.5 GHzIntermediate <strong>Frequency</strong>:Phase Noise:Test Output(Fixed Oscillator):Test Output(Microwave Oscillator):10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz2150 MHzfor 70 MHz IF Output2140 MHzfor 140 MHz IF Output2150 MHzfor 70 MHz IF Output2140 MHzfor 140 MHz IF Output2150 MHzfor 70 MHz IF Output2140 MHzfor 140 MHz IF Output-53-73-83-93-98 1)-108 1) -50-70-80-90-95 1)-105 1) -50-70-80-90-95 1)-105 1)max. values in dBc/ Hz1)0°C ... 50°C, outside this temperature range degraded by max 5 dB.2220 MHz (70 MHz IF)2280 MHz (140 MHz IF)-6 ± 3 dBm, ConnectorSMA female9.40…9.90 GHz(70 MHz IF)9.39…9.89 GHz(140 MHz IF)-7 ± 3 dBm 2)SMA female2220 MHz (70 MHz IF)2280 MHz (140 MHz IF)-6 ± 3 dBm, ConnectorSMA female12.85…14.90 GHz(70 MHz IF)12.84…14.89 GHz(140 MHz IF)-7 ± 3 dBm 2)SMA female2220 MHz (70 MHz IF)2280 MHz (140 MHz IF)-6 ± 3 dBm, ConnectorSMA female11.45…11.65 GHz(70 MHz IF)11.44…11.64 GHz(140 MHz IF)-7 ± 3 dBm 2)SMA femaleSpecifications continued next page2)-12 ± 3 dBm for Dual-B<strong>and</strong> units <strong>and</strong> Triple-B<strong>and</strong> units e.g. HCD3-CXKu2012-09-179


Satellite DownconverterIndoor VersionSingle / Dual / Triple B<strong>and</strong> Downconverter or Dual Channel DownconverterS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Specifications continued:Downconverter Type: HCD-Ka3-2 / SCD-Ka3-2 HCD-Ka6 / SCD-Ka6 HCD-Ka7 / SCD-Ka7RF-Input <strong>Frequency</strong>:Ka-B<strong>and</strong>17.7…19.5 GHz19.4…21.2 GHz(automatically switched)Ka-B<strong>and</strong>18.1…21.2 GHzKa-B<strong>and</strong>25.5…27.5 GHzIntermediate <strong>Frequency</strong>:Phase Noise:Test Output(Fixed Oscillator):Test Output(Microwave Oscillator):10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz2450 MHzfor 70 MHz IF Output2440 MHzfor 140 MHz IF Output2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF Input t2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF Input t-50-70-80-90-95 1)-105 1) -50-70-80-90-95 1)-105 1) -46-66-76-86-88 1)-101 1)max. values in dBc/ Hz1)0°C ... 50°C, outside this temperature range degraded by max 5 dB.2380 MHz (70 MHz IF)2300 MHz (140MHzIF)-6 ± 3 dBmSMA female15.25…18.75 GHz(70 MHz IF)15.26…18.76 GHz(140 MHz IF)- 7 ± 3 dBmSMA female2380 MHz (70 MHz IF)2300 MHz (140MHzIF)-6 ± 3 dBmSMA female15.65…18.75 GHz(70 MHz IF)15.66…18.76 GHz(140 MHz IF)- 7 ± 3 dBmSMA female2380 MHz (70 MHz IF)2300 MHz (140MHzIF)-6 ± 3 dBmSMA female11.525…12.525 GHz(70 MHz IF)11.53…12.53 GHz(140 MHz IF)- 7 ± 3 dBmSMA femaleSpecifications continued next page10 2012-09-17


Satellite DownconverterIndoor VersionSingle / Dual / Triple B<strong>and</strong> Downconverter or Dual Channel DownconverterS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Specifications continued:Conversion Scheme:<strong>Frequency</strong> Resolution:RF-Input Characteristics:IF-Output Characteristics:Transfer Characteristics:Equalizer (Gain Slope):Group Delay (± 18 MHz):Group Delay (± 36 MHz):Intermodulation (3 rd Order):AM / PM conversion:Spurious Outputs:Dual down-conversion, no frequency inversion10 HzImpedance:Return Loss:Max. input level:LO Leakage:RF-Connector:<strong>Frequency</strong>:Impedance:Return Loss:1 dB Compression Point:Output Muting:IF-Signal Monitor:IF-Connectors:Max. Conversion Gain:Attenuation Range:Gain Accuracy:Level Stability:Amplitude Response:Image Rejection:Noise Figure:max ± 2.5 dB / 40 MHz (IF 70 MHz),max ± 4 dB / 80 MHz (IF 140 MHz) (programmable)Linear:0.03 ns / MHz max.Parabolic:0.01 ns / MHz² max.Ripple:1 ns peak to peak max.Linear:Parabolic:Ripple:50>20 dB< approx. -25 dBm (operational)< approx. +10 dBm (damage level)< -80 dBmSMA female (St<strong>and</strong>ard)K female (RF Input > 18 GHz)70 ± 20 MHz or 140 ± 40 MHz (optional: both [IF-B<strong>and</strong>] = 70/140)50 or 75>20 dB>10 dBm, 13 dBm typical>60 dB (by comm<strong>and</strong> or sense input or by alarm condition)-20 dB of IF-output (approx.)BNC female45 dB (St<strong>and</strong>ard)0…30 dB, Step 0.1 dB (Conversion Gain 45…15 dB)± 1 dB± 0.25 dB/day (constant temperature)±0.2 dB / ± 18 MHz, ± 0.25 dB / ±20 MHz, ±0.4 dB / ± 40 MHz>80 dB


Satellite DownconverterIndoor VersionSingle / Dual / Triple B<strong>and</strong> Downconverter or Dual Channel DownconverterS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Order Information: HCD-[RF B<strong>and</strong>(s)]-[IF B<strong>and</strong> in MHz]-[IF Imp in Ω]-[Options] Single or Dual converterHCDx-[RF B<strong>and</strong>(s)]-[IF B<strong>and</strong> in MHz]-[IF Imp in Ω]-[Options] Multib<strong>and</strong> converterSCD-[RF B<strong>and</strong>(s)]-[IF B<strong>and</strong> in MHz]-[IF Imp in Ω]-[Options] Single or Dual converterSCDx-[RF B<strong>and</strong>(s)]-[IF B<strong>and</strong> in MHz]-[IF Imp in Ω]-[Options] Multib<strong>and</strong> converterx=2: Dualb<strong>and</strong> converter, x=3: Trib<strong>and</strong> converterPossible Options are: FAN (internal Fan)VFD (VFD display, st<strong>and</strong>ard with HCD-type converters)ALC-BW (Automatic level control- Filter b<strong>and</strong>width, see product:Automatic Level Control)2RFI (two switchable RF inputs)Examples:HCD-C-70-50 (C-b<strong>and</strong> downconverter)SCD-Ku-140-75-FAN (Ku-b<strong>and</strong> downconverter with internal Fan)HCD-C-70/140-50 (C-B<strong>and</strong> downconverter dual IF 70 <strong>and</strong> 140 MHz)HCD3-CXKu-70-50 (Trib<strong>and</strong> downconverter)SCD2-CKu-70-75 (Dualb<strong>and</strong> downconverter)SCD-CKu-70-75 (Dual channel downconverter C-b<strong>and</strong> <strong>and</strong> Ku-b<strong>and</strong>, identical IF <strong>and</strong> impedance)SCD-C-70-75/Ku-70-50-FAN (Dual channel downconverter C-b<strong>and</strong> <strong>and</strong> Ku-b<strong>and</strong> with Fan,different IF <strong>and</strong> impedance)12 2012-09-17


Visit us at www.work-microwave.deSatellite Up- <strong>and</strong> Downconverter,Outdoor VersionSingle / Dual / Triple B<strong>and</strong>S-, C-, X-, Ku-, K-, Ka-B<strong>and</strong>WORK Microwave provides it’s proven up- <strong>and</strong> downconvertersalso in an outdoor housing. The units canbe operated over a temperature range -30°C to 60°C(-22°F to 140°F). In the non-operating modus theysurvive temperatures of -50°C to 80°C (-58°F to176°F) without any damage. Same as the 19'' rackconverter units, they meet the requirements formodern satellite transmission such as TV up-link <strong>and</strong>high-speed data network. Because of their ruggedconstruction <strong>and</strong> low power consumption, they aremost suitable for fixed satellite earth stations, satellitenews gathering (SNG) vehicles, Fly-Aways <strong>and</strong> othermobile applications.Technology of the 4th GenerationAll WORK Microwave outdoor converters areequipped with the most modern technology of WORKMicrowaves’s 4 th generation satellite converters. Thisdesign allowed us to reduce the number ofcomponents by more than 30%. In addition significantcircuit improvements were made. This design resultsin an AC power consumption of typically35 VA / 23 W. The housing includes special internalheat dissipation structures, resulting in a completelypassively cooled unit. All this leads to high reliability<strong>and</strong> long lifetime.Outdoor installationWORK Microwave’s outdoor converters are best fit tobe mounted directly to the antenna. They do notrequire additional protection against water. Thehousing provides environmental protection accordingto IP67 (temporary flooding) when all cables areconnected <strong>and</strong> sealed appropriately. Special environmentalprotection sleeves for the coaxial connectorsallow optimal sealing from the housing to the cable, ifthese sleeves are used to seal the connection of thecable with adhesive shrinking tube or a rubber splicingtape (e.g. of type 3M/Scotch TM 130C). Additionally thehousing should be mounted with the connector sidedown. Alternatively the connector panel can be in avertical position.S-, C-, X-, Ku-, K- <strong>and</strong> Ka-, single, dual ortriple b<strong>and</strong> coverageWORK Microwave is offering the satellite outdoorconverters as single b<strong>and</strong> units covering S-, C-, X-,Ku-, K-B<strong>and</strong> <strong>and</strong> Ka-B<strong>and</strong> or as Dual or Triple b<strong>and</strong>units covering a combination of these frequencyb<strong>and</strong>s. They support the st<strong>and</strong>ard IF-frequency of70 ± 20 MHz or/<strong>and</strong> 140 ± 40 MHz. The conversion isperformed without spectral inversion. All WORKMicrowave upconverters offer an increased poweroutput (P 1dB = +10 dBm) in all versions.2012-09-1713


High signal integrityThe extreme low phase noise of the oscillatorsguarantees a very good signal quality. Low spuriousemissions allow using the converters also inenvironments with dem<strong>and</strong>ing requirements, like highpower video uplinks. Sophisticated temperaturecompensation guarantees gain stability over the fulltemperature range.Operating <strong>and</strong> control – easy integrationinto your systemThe converters can be operated via remote control(RS 232, RS422/485). Detailed monitoring of thesystem status <strong>and</strong> a summary alarm output (dualchange over switch contacts) are provided. For theremote control either ASCII string based comm<strong>and</strong>sas well as addressable, packet based comm<strong>and</strong>s areprovided.A separate 19" rack mount remote control unit allowsremote control of one or more units. The front panel ofthis unit is similar to the front panel of the 19” rackmount type.Customized productsIn addition to st<strong>and</strong>ard products WORK Microwaveoffers custom tailored products <strong>and</strong> specializedproducts as follows:Modified or smaller housingsDifferent IF or RF frequencyCustomized M&C interface <strong>and</strong> control syntaxExtended storage or operating temperature rangeMilitary versions for hostile environment (shock,vibration, humidity)Long term stability 10 -7 / yearOutput power +10 dBm (1 dB compression point)Low spurious emissions < -80 dBm at full gain(high performance series)Adjustable equalizerDigital gain compensationOperating temperature range -30°C to 60°C(-22°F to 140°F), storage temperature -50°C to80°C (-58°F to 140°F)Remote control through RS232 <strong>and</strong> RS422/485(2-wire or 4-wire bus) interfacesPacket comm<strong>and</strong> syntax supports RS485 bussystems <strong>and</strong> allows addressed operationSummary alarm output (dual change over switchcontacts) <strong>and</strong> transmit mute inputIP 67 protected housingCE compliant3 years warrantyOrder informationFor the Outdoor version only the High Performancetype is available due to environmental conditionswhich require the extended temperature range.Open questions, demo unitsIf you need more information about WORKMicrowave’s 4 th satellite converter generation or if youwould like to have a demo unit, please contact us viae-mail: sales@work-microwave.de or call us. We areglad to assist you.Key features70 MHz or 140 MHz IF b<strong>and</strong>s availableOptional switchable IF 70 MHz <strong>and</strong> 140 MHz(IF 70/140)Extreme low power consumption typical 32 VA /20 W (single b<strong>and</strong> unit) 35VA / 23W (triple b<strong>and</strong>units)Extreme low phase noise (< -50 dBc/Hz @10 Hz)Dimensions of Outdoor Housing14 2012-09-17


Satellite UpconverterOutdoor VersionSingle / Dual / Triple B<strong>and</strong>S-, C-, X-, Ku-, K-, Ka-B<strong>and</strong>H-Type (extended temperature range)Upconverter Type: HCU-S-OD HCU-C-OD HCU-C1-OD HCU-X-ODRF-Output <strong>Frequency</strong>:S-B<strong>and</strong>C-B<strong>and</strong>C-B<strong>and</strong>X-B<strong>and</strong>2.025…2.110 GHz5.85…6.65 GHz5.85…7.025 GHz7.90…8.40 GHzIntermediate <strong>Frequency</strong>:Phase Noise:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF Input2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF Input2610 MHzfor 70 MHz IF Input2600 MHzfor 140 MHz IF Input2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF Input-60-80-90-100-105 1)-112 1) -55-75-85-95-100 1))-110 1)) -55-75-85 )-95-100 1)-110 1)) -53-73-83-93-98 1)-108 1)max. values in dBc/ Hz1)0°C ... 50°C, outside this temperature range degraded by max 5 dB.Upconverter Type: HCU-Ku-OD HCU-K-OD HCU-Ka-OD Other b<strong>and</strong>sRF-Output <strong>Frequency</strong>:Ku-B<strong>and</strong>K-B<strong>and</strong>Ka-B<strong>and</strong>available on request as for12.75…14.50 GHz17.3…18.4 GHz29.7…31.5 GHz HCU / SCU Indoor unitsIntermediate <strong>Frequency</strong>:Phase Noise:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF Input2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF Input2450 MHzfor 70 MHz IF Input2440 MHzfor 140 MHz IF Input-50-70-80-90-95 1)-105 1) -50-70-80-90-95 1)-105 1) -46-66-76-86-88 1)-101 1)max. values in dBc/ Hz1)0°C ... 50°C, outside this temperature range degraded by max 5 dB.Conversion Scheme:<strong>Frequency</strong> Resolution:IF-Input Characteristics:RF-Output Characteristics:Transfer Characteristics:Equalizer (Gain Slope):Group Delay (± 18 MHz):Group Delay (± 36 MHz):Intermodulation (3 rd Order):AM / PM conversion:Spurious Outputs:Dual up-conversion, no frequency inversion10 Hz<strong>Frequency</strong>:Impedance:Return Loss:IF-Connectors:Impedance:Return Loss:1 dB Compression Point:Output Muting:RF-Connectors:Max. Conversion Gain:Attenuation Range:Gain Accuracy:Level Stability:Amplitude Response:Image Rejection:Noise Figure:max ± 2.5 dB / 40 MHz (IF 70 MHz),max ± 4 dB / 80 MHz (IF 140 MHz) (programmable)Linear:0.03 ns / MHz max.Parabolic:0.01 ns / MHz² max.Ripple:1 ns peak to peak max.Linear:Parabolic:Ripple:70 ± 20 MHz or 140 ± 40 MHz(optional: both: [IF-B<strong>and</strong>] = 70/140, not in combination withDualb<strong>and</strong> or Trib<strong>and</strong> units)50 or 75>20 dBN female50>20 dB **>10 dBm>60 dB (by comm<strong>and</strong> or sense input or by alarm condition)SMA femaleK female (RF output >18 GHz)40 dB0…30 dB, Step 0.1 dB (Conversion Gain 40…10 dB)± 1 dB± 0.25 dB/day (constant temperature)±0.2 dB / ± 18 MHz, ± 0.25 dB / ±20 MHz, ±0.4 dB / ± 40 MHz>80 dB


Satellite UpconverterOutdoor VersionSingle / Dual / Triple B<strong>and</strong>S-, C-, X-, Ku-, K-B<strong>and</strong>H-Type (extended temperature range)Specifications continued:Reference Input (Option RIN):Reference Output (Option ROUT):Monitoring <strong>and</strong> Control Interface:Temperature Range:<strong>Frequency</strong>:Level:Modes:Impedance:Connector:<strong>Frequency</strong>:Level:Impedance:Connector:Relative Humidity:


Satellite DownconverterOutdoor VersionSingle / Dual / Triple B<strong>and</strong>S-, C-, X-, Ku-B<strong>and</strong>H-Type (extended temperature range)Downconverter Type: HCD-S-OD HCD-C-OD HCD-C1-OD Other b<strong>and</strong>sRF-Input <strong>Frequency</strong>:Intermediate <strong>Frequency</strong>:Phase Noise:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHzS-B<strong>and</strong>2.2…2.3 GHz2450 MHzfor 70 MHz IF Output2440 MHzfor 140 MHz IF OutputC-B<strong>and</strong>3.4…4.2 GHz2150 MHzfor 70 MHz IF Output2140 MHzfor 140 MHz IF OutputC-B<strong>and</strong>3.4…4.8 GHz2150 MHzfor 70 MHz IF Output2140 MHzfor 140 MHz IF Outputavailable on request as forHCD / SCD Indoor units-60-80-90-100-105 1)-112 1) -56-76-86-96-101 1)-111 1) -56-76-86-96-101 1-111 1)max. values in dBc/ Hz1)0°C ... 50°C, outside this temperature range degraded by max 5 dB.Downconverter Type: HCD-X-OD HCD-Ku-OD HCD-Ku4-OD HCD-Ka4-ODRF-Input <strong>Frequency</strong>:Intermediate <strong>Frequency</strong>:Phase Noise:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHzX-B<strong>and</strong>7.25…7.75 GHz2150 MHzfor 70 MHz IF Output2140 MHzfor 140 MHz IF OutputKu-B<strong>and</strong>10.70…12.75 GHz2150 MHzfor 70 MHz IF Output2140 MHzfor 140 MHz IF OutputKu-B<strong>and</strong>9.3…9.5 GHz2150 MHzfor 70 MHz IF Output2140 MHzfor 140 MHz IF OutputKa-B<strong>and</strong>27.5…31 GHz5170 MHzfor 70 MHz IF Input5100 MHzfor 140 MHz IF Input-53-73-83-93- 8 1)-108 1)) -50-70-80-90-95 1)-105 1)) -50-70-80-90-95 1)-105 1) -46-66-76-86-88 1)-101 1)max. values in dBc/ Hz1)0°C ... 50°C, outside this temperature range degraded by max 5 dB.Conversion Scheme:<strong>Frequency</strong> Resolution:RF-Input Characteristics:IF-Output Characteristics:Transfer Characteristics:Equalizer (Gain Slope):Group Delay (± 18 MHz):Group Delay (± 36 MHz):Intermodulation (3 rd Order):AM / PM conversion:Spurious Outputs:Dual down-conversion, no frequency inversion10 HzImpedance:Return Loss:Max. input level:LO Leakage:RF-Connector:<strong>Frequency</strong>:Impedance:Return Loss:1 dB Compression Point:Output Muting:IF-Connectors:Max. Conversion Gain:Attenuation Range:Gain Accuracy:Level Stability:Amplitude Response:Image Rejection:Noise Figure:50>20 dB< approx. -25 dBm (operational)< approx. +10 dBm (damage level)18 GHz)70 ± 20 MHz or 140 ± 40 MHz(optional: both: [IF-B<strong>and</strong>] = 70/140, not in combination withDualb<strong>and</strong> or Trib<strong>and</strong> units)50 or 7510 dBm, 13 dBm typical>60 dB (by comm<strong>and</strong> or sense input or by alarm condition)N female45 dB0…30 dB, Step 0.1 dB (Conversion Gain 45…15 dB)± 1 dB± 0.25 dB/day (constant temperature)±0.2 dB / ± 18 MHz, ± 0.25 dB / ±20 MHz, ±0.4 dB / ± 40 MHz>80 dB


Satellite DownconverterOutdoor VersionSingle / Dual / Triple B<strong>and</strong>S-, C-, X-, Ku-, K-B<strong>and</strong>Specifications continued:<strong>Frequency</strong> Stability: ± 1 x 10 -7 , 0°C ... 50°C± 2 x 10 -8 , 0°C ... 50°C (after 30 min warm up)± 1.5 x 10 -9 per day (fixed temperature after 24 h warm up)Reference Input (Option RIN):Reference Output (Option ROUT):Monitoring <strong>and</strong> Control Interface:Temperature Range:<strong>Frequency</strong>:Level:Modes:Impedance:Connector:<strong>Frequency</strong>:Level:Impedance:Connector:Relative Humidity:


Visit us at www.work-microwave.deDual Channel, Shared OscillatorDownconverterS-, Ku-, Ka-B<strong>and</strong>Triple Channel <strong>Converters</strong> also availableAlso available as Outdoor VersionThe satellite downconverters developed <strong>and</strong>manufactured by WORK Microwave are designed tomeet the requirements of modern satellitetransmission. Customers worldwide appreciate theirreliability <strong>and</strong> high level of quality. These types of dualchannel, shared oscillator converters can be used insystems, where an accurate phase relationship isrequired between two converter channels, as it is e.g.the case for monopulse tracking system downconversion.Operating <strong>and</strong> controlThe converters can be operated via the push buttonson the front panel using self-explanatory displaymenus or via remote control (RS232, RS422/485,TCP/IP over Ethernet).Detailed monitoring of the system status <strong>and</strong> a summaryalarm output (dual change over switch contacts)are provided. For the remote control either ASCIIstring based comm<strong>and</strong>s as well as addressable,packet based comm<strong>and</strong>s are provided.Housing optionsThe converters normally are delivered without fans<strong>and</strong> can be operated in environments, where atminimum 1 RU space for natural ventilation isavailable above each unit. This eliminates the fan aspotential point of failure. For rack installations withoutany space in between the units a fan within theconverter unit is recommended, which forces anairflow from the right side to left side of the units.Outdoor versions with IP67 degree of protection arealso available.Key featuresShared oscillator to guarantee excellent phasetracking in between channels70 MHz or 140 MHz IF b<strong>and</strong>s availableLow power consumptionExtreme low phase noise (< -60 dBc/Hz @ 10 Hz)Long- term stability 10 -7 / yearOutput power +10 dBm (1 dB compression point)Automatic reference recognition (5 <strong>and</strong> 10 MHz)0°C to 50°C (32°F to 122°F) (SCD units)-30°C to 60°C (-22°F to 140°F) (HCD units)Remote control through RS232, RS422/485(2-wire or 4-wire) interfaces. Packet comm<strong>and</strong>syntax supports RS485 bus systems <strong>and</strong> allowsaddressed operation.Remote control through Ethernet supporting aTCP/IP comm<strong>and</strong> interface (Indoor Version only)IF test outputs (st<strong>and</strong>ard on indoor units, onoutdoor units with Option IFT)Summary alarm output (dual change over switchcontacts)Internal Fan as option for indoor units(Option FAN)CE compliant3 years warranty2012-09-1719


Dual Channel, Shared Oscillator DownconverterDownconverter Type: HCD-SST / SCD-SST HCD-KuKuT / SCD-KuKuT HCD-KaKaT / SCD-KaKaTRF-Input <strong>Frequency</strong>:S-B<strong>and</strong>Ku-B<strong>and</strong>Ku-B<strong>and</strong>2.2…2.3 GHz10.70…12.75 GHz 19.70…20.10 GHzIntermediate <strong>Frequency</strong>:Phase Noise:Test Output(Fixed Oscillator):Test Output(Microwave Oscillator):Conversion Scheme:Phase Tracking betweenchannels:<strong>Frequency</strong> Resolution:RF-Input Characteristics:IF-Output Characteristics:Transfer Characteristics:Group Delay (± 18 MHz):Group Delay (± 36 MHz):Intermodulation (3 rd Order):AM / PM conversion:Spurious Outputs:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz2450 MHzfor 70 MHz IF Output2440 MHzfor 140 MHz IF Output2150 MHzfor 70 MHz IF Output2140 MHzfor 140 MHz IF Output2150 MHzfor 70 MHz IF Output2140 MHzfor 140 MHz IF Outputother frequency b<strong>and</strong>son request-60-80-90-98-103 1)-112 1) -50-70-80-90-95 1)-105 1) -50-70-80-90-95 1)-105 1)max. values in dBc/ Hz1)0°C ... 50°C, outside this temperature range degraded by max 5 dB.2520 MHz (70 MHz IF)2580 MHz (140 MHz IF)-6 ± 3 dBm, ConnectorSMA female4.65…4.75 GHz(70 MHz IF)4.64…4.74 GHz(140 MHz IF)-7 ± 3 dBmSMA female2220 MHz (70 MHz IF)2280 MHz (140 MHz IF)-6 ± 3 dBm, ConnectorSMA female12.85…14.90 GHz(70 MHz IF)12.84…14.89 GHz(140 MHz IF)-7 ± 3 dBmSMA female2220 MHz (70 MHz IF)2280 MHz (140 MHz IF)-6 ± 3 dBm, ConnectorSMA female8.775…8.975 GHz(70 MHz IF)8.78…8.98 GHz(140 MHz IF)-7 ± 3 dBmSMA femaleDual down-conversion, no frequency inversionTwo channels with shared oscillators:Same conversion frequency for both channelsGain setting individual for each channel20 dB< approx. -25 dBm (operational)< approx. +10 dBm (damage level)20 dB>10 dBm, 13 dBm typical>60 dB (by comm<strong>and</strong> or sense input or by alarm condition)-20 dB of IF-output on front panel, SMA female (St<strong>and</strong>ard on Indoor unit )-20 dB of IF output, SMA female (Outdoor unit with Option IFT)BNC female (Indoor Version)N female (Outdoor Version)45 dB0…30 dB, Step 0.1 dB (Conversion Gain 45…15 dB)± 2 dB± 0.25 dB/day (constant temperature)±0.2 dB / ± 18 MHz, ± 0.25 dB / ±20 MHz, ±0.4 dB / ± 40 MHz>80 dB 60 dB0.03 ns / MHz max.0.01 ns / MHz² max.1 ns peak to peak max.0.015 ns / MHz max.0.005 ns / MHz² max.2 ns peak to peak max.< -60 dBc ( f < 1 MHz), < -70 dBc ( f 1 MHz)< -76 dBm (< -80 dBm typical)10 MHz or 5 MHz-3…10 dBminternal, external, auto (senses reference input)BNC female (Indoor Version)SMA female (Outdoor Version)10 MHz0 ± 3 dBmBNC female (Indoor Version)St<strong>and</strong>ard on IndoorVersionWith Option RIN onOutdoor Versionon Indoor Version onlySpecifications continued next page20 2012-09-17


Dual Channel, Shared Oscillator DownconverterSpecifications continued:Monitoring <strong>and</strong> Control Interface: TCP/IP over Ethernet (10 or 100 Mbps, auto sensing)RS232 or RS422/RS485 (Connectors DSUB09 female) (configurable by software) Indoor VersionAlarm output: Two potential free contacts (DPDT, Connector DSUB09 female)RS232 or RS422/RS485Alarm output: Two potential free contacts (DPDT)24 V DC output: max 0,3 A6,5 V DC output: max 0,2 AOutdoor VersionMute Input: TTL logic input with internal pull up(Connector type: MIL-C-26482: MS 3120 E 14-19 S)MTBF50000 hours (typical)Internal Fan with Option FAN Indoor Version onlyTemperature Range:HCU : -30°C … 60°C operating (10 minutes warm up at -30°C)SCU: 0°C … 50°C operatingIndoor Version-30°C … 80°C storage-30°C … 60°C operating (10 minutes warm up at -30 °C)Outdoor VersionRelative Humidity:


Visit us at www.work-microwave.deInmarsat DownconverterNarrowb<strong>and</strong> DownconverterL-B<strong>and</strong> to 70/140 MHzS-B<strong>and</strong> to 725 MHz140 MHz to 15 MHzSingle ConversionDual Channel <strong>Converters</strong> are also available.These narrowb<strong>and</strong> converters of WORK Microwaveare designed to meet the requirements of specificapplications, where often single conversion issufficient as the required b<strong>and</strong>width coverage is quitenarrow <strong>and</strong> the difference of the input <strong>and</strong> outputfrequency is not too big. They are based on the sameproven core modules as used in the st<strong>and</strong>ard satelliteupconverters <strong>and</strong> downconverters of WORKMicrowave. Additional special functions can beincluded:Application specific filtering.Automatic level control. The output level is keptconstant independent of the strength of the inputsignal with adjustable control characteristics.Additional PLO output.DC bias tee included at signal input to provide DCpower to LNAs or LNBs.Also a combination of two converters, resulting in adual channel unit, is possible. One if these units canalso be a dual conversion down-converter.Operating <strong>and</strong> controlThe converters can be operated via the push buttonson the front panel using self-explanatory displaymenus or via remote control (RS232, RS422/485,TCP/IP over Ethernet).Detailed monitoring of the system status <strong>and</strong> a summaryalarm output (dual change over switch contacts)are provided. For the remote control either ASCIIstring based comm<strong>and</strong>s as well as addressable,packet based comm<strong>and</strong>s are provided.Housing optionsThe converters normally are delivered without fans<strong>and</strong> can be operated in environments, where atminimum 1 RU (19”) space for natural ventilation isavailable above each unit. This eliminates the fan aspotential point of failure. For rack installations withoutany space in between the units a fan within theconverter unit is recommended, which forces anairflow from the right side to left side of the units.High signal integrityThe extreme low phase noise of the oscillatorsguarantees a very good signal quality. Low spuriousemissions allow to use the converters also inenvironments with dem<strong>and</strong>ing requirements, like highpower video uplinks. Sophisticated temperaturecompensation guarantees gain stability over a verywide temperature range.22 2012-09-17


Inmarsat DownconverterIndoor VersionL-B<strong>and</strong> to 70/140 MHz, Single or Dual Channel DownconverterS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Downconverter Type:RF-Input <strong>Frequency</strong>:Conversion Scheme:LO-<strong>Frequency</strong>:RF-Input Characteristics:IF-Output Characteristics:Transfer Characteristics:Equalizer (Gain Slope):Intermodulation (3 rd Order):Phase Noise :Spurious Outputs:<strong>Frequency</strong> Stability:Reference Input:Reference Output:Reference Output(Option PLO187):DC Power to external LNA(Option DC15):Monitoring <strong>and</strong> Control Interface:Alarm Interface:Mute Input:Temperature Range:Relative Humidity:HCD-Lx / SCD-Lx or HCD-LxLx / SCD-LxLxL-B<strong>and</strong>L1: 1525,0…1559,0 MHz (single b<strong>and</strong>)L2: 1626,5…1660,5 MHz (single b<strong>and</strong>)L: 1525,0…1559,0 MHz or 1626,5…1660,5 MHz (single b<strong>and</strong>, input b<strong>and</strong> front panel selectable)L1L1: 1525,0…1559,0 MHz <strong>and</strong> 1525,0…1559,0 MHz (dual channel)L2L2: 1626,5…1660,5 MHz <strong>and</strong> 1626,5…1660,5 MHz (dual channel)LL: 1525,0…1559,0 MHz or 1626,5…1660,5 MHz (dual channel, input b<strong>and</strong> front panel selectable)Single down conversion, no frequency inversionL1: 1402,0 MHz, L2: 1503,5 MHzImpedance:Return Loss:RF-Connector:Max. Input Level:IIP 3:Cross Talk:<strong>Frequency</strong>:Impedance:Return Loss:1 dB Compression Point:Output Muting:IF-Signal Monitor:IF-Connector:Max. Conversion Gain:Attenuation Range:Gain Accuracy:Level Stability:Amplitude Response:Noise Figure:± 2.5 dB / 40 MHz (programmable)50>18 dBSMA female-20 dBm @ IP3 < -60 dBc (operation)-10 dBm @ IP3 < -30 dBc (operation)+10 dBm (damage level)0 dBmUnit 1 to IF out @ unit 2: < -80 dB (only dual channel)140 ± 17 MHz50 or 75>18 dB>10 dBm, 13 dBm typical>60 dB (by comm<strong>and</strong> or sense input or by alarm condition)-20dB of IF-output (approx,)SMA female35 dB0…30 dB, Step 0.1 dB (Conversion Gain 35…5 dB)± 1 dB± 0.25 dB/day (constant temperature)± 0.5 dB / 10 MHz15 dB0 ± 3 dBmSMA female187.20 MHz (other frequencies on request)50>15 dB


Inmarsat DownconverterIndoor VersionL-B<strong>and</strong> to 70/140 MHz DownconverterS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Specifications continued:User Interface:Mains Power Input:Mains Power Consumption:Mains Power Input Connector:SCU: LCD-Display 2 x 40 characters, 4 cursor keys, 4 function keysHCU: VFD-Display 2 x 40 characters, 4 cursor keys, 4 function keys100 … 240 V AC nominal, 90…264 V AC max, 50…60 HzTyp: 35 VA / 23 WIEC C14Mains Fuse:2 x 3.15 A (or 2 A) time-lag fuseDimension <strong>and</strong> Weight: 483 x 44 x 505 mm³ (WxHxD), 1 RU (19")approx. 8.6 kgSpecifications are subject to changeOrder Information:HCD-[RF B<strong>and</strong>(s)]-[IF B<strong>and</strong> in MHz]-[IF Imp in Ω]-[Options]SCD-[RF B<strong>and</strong>(s)]-[IF B<strong>and</strong> in MHz]-[IF Imp in Ω]-[Options]Possible Options are: FAN (internal Fan)VFD (VFD display, st<strong>and</strong>ard with HCD-type converters)DC15 (DC bias tee on signal input with 15 V DC output)PLO187 (additional 187 MHz reference signal output)ALC-BW (Automatic level control- Filter b<strong>and</strong>width, see product:Automatic Level Control)Examples:HCD-L1-140-50SCD-L2L2-140-75-FAN-DC15-PLO187HCD-LL-140-50-FAN-DC15SCD-LC-140-50-FAN Combination with of L-B<strong>and</strong> (Narrowb<strong>and</strong>) Downconverter <strong>and</strong>C-B<strong>and</strong> Satellite Downconverter) with Fan242012-09-17


Satellite Narrowb<strong>and</strong> DownconverterIndoor VersionS-B<strong>and</strong> to 725 MHz DownconverterS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Downconverter Type:<strong>Frequency</strong> resolution:RF-Input <strong>Frequency</strong>:Conversion Scheme:SCD-S100 kHz2.3…2.95 GHzSingle down-conversion, no frequency inversionLO <strong>Frequency</strong>:RF-Input Characteristics:IF-Output Characteristics:Transfer Characteristics:1.55…2.25 GHzImpedance:Return Loss:Maximum Aggregate Input Level:LO LeakageRF-Connector<strong>Frequency</strong>:Impedance:Return Loss:1 dB Compression Point:IF-Connectors:Conversion Gain:Gain-Resolution:Gain Accuracy:Gain Stability:Amplitude Ripple:IF Output B<strong>and</strong>width (3 dB):Noise Figure:50>15 dB (VSWR = 1.22)0 dBm15 dB (VSWR = 1.22)>7 dBmSMA female5…35 dB1 dB± 0.2 dB typical (± 0.3 dB max.)± 0.25 dB/day (constant temperature)± 0.2 dB / 20 MHz1 GHz 2)< 12 dB 2)Group Delay (700…750 MHz): Ripple, Slope: < 2 ns peak ... peak / 80 MHzIntermodulation (3 rd Order):AM / PM conversion:Phase Noise:-60 dBc max ( f in : 5 MHz, P out ges : < -12 Bm) (OIP3 = +15 dBm)0.1° / dB (P out = 0 dBm)10 Hz100 Hz1 kHz10 kHz100 kHz1 MHzSpurious Outputs: Signal dependent:


Satellite Downconverter Narrowb<strong>and</strong>Indoor Version140 MHz to 15 MHz DownconverterS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Downconverter Type:VHF-Input <strong>Frequency</strong>:Conversion Scheme:DNC-V80…200 MHzSingle down-conversion, no frequency inversionLO <strong>Frequency</strong>:RF-Input Characteristics:IF-Output Characteristics:Transfer Characteristics:Internal Filter*:*) other filter characteristics on requestExternal Filter:Phase Noise:Spurious Outputs:<strong>Frequency</strong> Stability:Reference Input:Reference Output:Monitoring <strong>and</strong> Control Interface:Temperature Range:Relative Humidity:User Interface:Mains Power Input:Mains Power Consumption:Mains Power Input Connector:80…200 MHz, Resolution 10 HzImpedance:Return Loss:Maximum Aggregate Input Level:50>14 dB< -25 dBm (operational)10 dBm>60 dB (during warm-up or during alarm condition)BNC female45 dB0…30 dB, Step 0.1 dB (Conversion Gain 45…15 dB)± 1.5 dB± 0.25 dB/day (constant temperature)± 0.25 dB / 20 MHz


Visit us at www.work-microwave.deSynthesized BlockUp- <strong>and</strong> DownconverterS, C, X, Ku, K, Ka-B<strong>and</strong>The satellite up- <strong>and</strong> downconverters developed <strong>and</strong>manufactured by WORK Microwave are designed tomeet the requirements of modern satellitetransmission, like TV uplink <strong>and</strong> high speed datanetworks. Analogue transmission formats aresupported as well as digital transmission formats. Formany years these devices have been used worldwidein fixed satellite earth stations as well as in satellitenews gathering (SNG) vehicles <strong>and</strong> Fly-Aways <strong>and</strong>other mobile or portable applications. These kind ofconverters have been built for more than 1200 timesso far. Customers worldwide appreciate their reliability<strong>and</strong> high level of quality.4th Generation – still betterThe 4 th generation, based on our experience <strong>and</strong> skill,is still better. The synthesizer <strong>and</strong> oscillator portion inevery satellite converter is the most importantcomponent because it decides the converter'sreliability. For many years WORK Microwave hasbeen developing <strong>and</strong> manufacturing highsophisticated microwave oscillators <strong>and</strong> synthesizerswhich are used in our converter series as well. Thenew design allows us to reduce the number ofcomponents by more than 30%. In addition, significantimprovements have been made on circuit design.This design results in an AC power consumption oftypically 35 VA / 27 W. This leads to an even higherreliability <strong>and</strong> longer life time.High signal integrityThe extreme low phase noise of the oscillatorsguarantees an excellent signal quality. Low spuriousemissions allow our customers to use the convertersalso in the environments with dem<strong>and</strong>ingrequirements, such as high power video uplinks.Sophisticated temperature compensation guaranteesthe stability over a very wide temperature range.Block Converter with frequency synthesizerIn contrast to block converters with fixed or switchable LO these converters include a tunable LO with10 Hz step size. The frequency b<strong>and</strong>width is selectedto achieve low spurious emissions. These propertiesallow wideb<strong>and</strong> frequency coverage with only oneunit, where other concepts with fixed block convertersrequire several different block converter modules.Housing optionsThe converters normally are delivered without fans<strong>and</strong> can be operated in environments, where atminimum 1 RU space for natural ventilation isavailable above each unit. This eliminates the fan aspotential point of failure. For rack installations withoutany space in between the units a fan within theconverter unit is recommended, which forces anairflow from the right side to left side of the units.2012-09-17 27


The converters can be operated via the push buttonson the front panel using self-explanatory displaymenus or via remote control (RS232, RS422/485,TCP/IP over Ethernet). Detailed monitoring of thesystem status <strong>and</strong> a summary alarm output (dualchange over switch contacts) are provided. For theremote control either ASCII string based comm<strong>and</strong>sas well as addressable, packet based comm<strong>and</strong>s areprovided.Remote monitoring <strong>and</strong> control through SNMP <strong>and</strong> aWeb browser interface is also available.Customized productsIn addition to st<strong>and</strong>ard products WORK Microwaveoffers custom tailored products <strong>and</strong> specializedproducts as follows:Modified or smaller housings to fit into your ACpower switch on the front panelExisting design for mobile <strong>and</strong> portableapplications.Different IF or RF frequency b<strong>and</strong>s, Ka-B<strong>and</strong>(28GHz) version is under development.Customized M&C interface <strong>and</strong> control syntax.Extended storage or operating temperature range.Military versions for hostile environment (shock,vibration, humidity).Key featuresExtreme low power consumption maximum35 VA / 27 W (single b<strong>and</strong> unit) 37 VA / 29 W(triple b<strong>and</strong> units)Extreme low phase noise (< -50 dBc/Hz @ 10 Hz)Long- term stability 10 -7 / yearOutput power +10 dBm (1 dB compression point)Low spurious emissions < -80 dBm at full gain(high performance series)Automatic reference recognition (5 <strong>and</strong> 10 MHz)Digital gain compensationOperating temperature range either -30 °C to60 °C (-22 °F to 140 °F) or 0°C to 50 °C (32 °F to122 °F)Remote control through RS232, RS422/485(2-wire or 4-wire) interfaces. Packet comm<strong>and</strong>syntax supports RS485 bus systems <strong>and</strong> allowsaddressed operation.Remote control through Ethernet supporting aTCP/IP comm<strong>and</strong> interface, a Web browserinterface <strong>and</strong> SNMP (MIBs are provided).RF test output on the front panel (upconverteronly)AC power switch on the front panelSummary alarm output (dual change over switchcontacts)Transmit mute inputOptional internal Fan (Option: FAN)CE compliant3 years warrantyOrders informationWORK Microwave offers two series of 19” racksatellite converters, St<strong>and</strong>ard <strong>and</strong> High Performance.The specifications are the same for both types exceptthe operating temperature range. The HighPerformance type operates between -30 °C to 60 °C(-22 °F to 140 °F) <strong>and</strong> the st<strong>and</strong>ard type between 0 °Cto 50 °C (32 °F to 122 °F). So if you only need unitsfor inside use, the st<strong>and</strong>ard unit is perfectly suited forthis application.Open questions, demo unitsIf you need more information about WORKMicrowave’s 4 th satellite converter generation or if youwould like to have demo unit, please contact us via e-mail: sales@work-microwave.de or call us. We areglad to assist you.282012-09-17


Synthesized Block UpconverterIndoor VersionSingle B<strong>and</strong> Synthesized Block Upconverter, L-B<strong>and</strong> InputS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Upconverter Type: HSBU-Ku1 /SSBU-Ku1RF-Output <strong>Frequency</strong>:Ku-B<strong>and</strong>12.75…13.25 GHzHSBU-Ku2 /SSBU-Ku2Ku-B<strong>and</strong>13.75…14.5 GHzHSBU-Ku-2-S002 /SSBU-Ku-2-S002Ku-B<strong>and</strong>10.70 …11.80 GHz11.65 …12.75 GHz(automaticallyswitched)HSBU-Ku4SSBU-Ku4Ku-B<strong>and</strong>12.9…13.5 GHzHSBU2-Ku2Ku4SSBU2-Ku2Ku4Ku-B<strong>and</strong>13.75 …14.5 GHz (Ku2)12.9 …13.5 GHz (Ku4)(automatically switched)RF-Output Return Loss: > 20 dB > 20 dB > 20 dB > 20 dB > 20 dBLO-<strong>Frequency</strong>:11.8…11.95 GHz 12.3…12.75 GHz 9.2…11.1 GHz12.8 GHz (Ku2)11.95 GHz10 Hz steps10 Hz steps10 Hz steps11.95 GHz (Ku4)Phase Noise:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz-50-70-80-90-95 1)-105 1) -50-70-80-90-95 1)-105 1) -50-70-80-90-95 1)-105 1) -50-70-80-90-95 1)-105 1) -50-70-80-90-95 1)-105 1)max. values in dBc/ Hz1)0°C …50°C, outside this temperature range degraded by max 5 dB.Input <strong>Frequency</strong>: 0.95…1.45 GHz 1.0…1.75 GHz(1,45…1.75 GHz)Conversion Scheme:Single up-conversion, no frequency inversion1.5…1.65 GHz 0.95…1.55 GHz 0.95…1.7 GHzUpconverter Type: HSBU-K /SSBU-KRF-Output <strong>Frequency</strong>:K-B<strong>and</strong>17.3…18.4 GHzHSBU-K1 /SSBU-K1K-B<strong>and</strong>17.3…18.1 GHzHSBU-K-2 /SSBU-K-2K-B<strong>and</strong>17.3…18.1 GHz17.6…18.4 GHz(automaticallyswitched)RF-Output Return Loss: > 17 dB > 17 dB > 17 dBLO-<strong>Frequency</strong>:15.85…16.65 GHz, 16.05…16.35 GHz, 16,05…16.65 GHz,10 Hz steps10 Hz steps10 Hz stepsPhase Noise:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz-50-70-80-90-95 1)-105 1) -50-70-80-90-95 1)-105 1) -50-70-80-90-95 1)-105 1)max. values in dBc/ Hz1)0°C … 50°C, outside this temperature range degraded by max 5 dB.Input <strong>Frequency</strong>: 1.45 … 1.75 GHz 1.25 … 1.75 GHz 1.25 … 1.75 GHzConversion Scheme:Single up-conversion, no frequency inversionUpconverter Type: HSBU-Ka-2-S001 /SSBU-Ka-2-S001RF-Output <strong>Frequency</strong>:Ka-B<strong>and</strong>17.7…19.5 GHz19.4…21.2 GHz(automaticallyswitched)HSBU-Ka8 /SSBU-Ka8Ka-B<strong>and</strong>22.55 … 23.15 GHzHSBU-Ka9 /SSBU-Ka9Ka-B<strong>and</strong>26.3 … 26.7 GHzHSBU-Ka12 /SSBU-Ka12Ka-B<strong>and</strong>27.5 … 28.25 GHzRF-Output Return Loss: > 17 dB > 17 dB > 17 dB > 17 dBLO-<strong>Frequency</strong>:15.2…18.7 GHz, 21.55 GHz25.3 GHz26.5 GHz10 Hz stepsfixedfixedfixedPhase Noise:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz-50-70-80-90-95 1)-105 1) -46-66-76-86-91-101-46-66-76-86-91-101-46-66-76-86-91-101max. values in dBc/ Hz1)0°C … 50°C, outside this temperature range degraded by max 5 dB.Input <strong>Frequency</strong>: 2.45 … 2.55 GHz 1.0 … 1.6 GHz 1.0 … 1.4 GHz 1.0 … 1.75 GHzConversion Scheme:Single up-conversion, no frequency inversionSpecifications continued next page2012-09-17 29


Synthesized Block UpconverterIndoor VersionSingle B<strong>and</strong> Synthesized Block Upconverter, L-B<strong>and</strong> InputS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Specifications continued:Upconverter Type: HSBU-Ka4 /SSBU-Ka4RF-Output <strong>Frequency</strong>:RF-Output Return Loss:Phase Noise:LO2-<strong>Frequency</strong>:Intermediate <strong>Frequency</strong>:LO1-<strong>Frequency</strong>::Input-<strong>Frequency</strong>:Conversion Scheme:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHzKa-B<strong>and</strong>27.5 … 31.0 GHz> 17 dB-46-66-76-86-91-101max. values in dBc/ Hz36.2 … 39.0 GHz10 Hz steps8.0 … 8.7 GHz9.7 GHz1.0 … 1.7 GHzDual up-conversion, no frequency inversion1)0°C …50°C, outside this temperature range degraded by max 5 dB.IF-Input Characteristics:RF-Output Characteristics:Transfer Characteristics:Impedance:Return Loss:IF-Connectors:Impedance:1 dB Compression Point:Output Muting:RF-Connectors:Conversion Gain:Attenuation Range:Gain Variation over Temp.:Gain Flatness over Freq.:Gain Flatness over 40 MHz:Gain Stability:Image Rejection:Noise Figure:50>15 dBSMA female50>10 dBm (st<strong>and</strong>ard)>20 dBm (for HSBU-Ku-2-S002 / SSBU-Ku-2-S002)>13 dBm (for HSBU-Ka-2-S001 / SSBU-Ka-2-S001)>70 dB (by comm<strong>and</strong> or sense input or by alarm condition)SMA female (St<strong>and</strong>ard)K-female ( RF Output >18 GHz)30 dB (st<strong>and</strong>ard)40 dB (HSBU/SSBU-Ku-2-S002)20 dB (HSBU/SSBU Ka4, HSBU/SSBU Ka8)0…30 dB, 0.1 dB steps (St<strong>and</strong>ard)0 dB fixed gain (HSBU/SSBU-Ka-2-S001)±1 dB max±1.5 dB max. over b<strong>and</strong> (C, X or Ku)±0.5 dB±0.25 dB>80 dB


Synthesized Block UpconverterIndoor VersionSingle B<strong>and</strong> Synthesized Block Upconverter, L-B<strong>and</strong> InputS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Specifications continued:Reference Input:Reference Output:Monitoring <strong>and</strong> Control Interface:Alarm Interface:Mute Input:Temperature Range:Relative Humidity:User Interface:Mains Power Input:Mains Power Consumption:<strong>Frequency</strong>:Level:Modes:Connector:<strong>Frequency</strong>:Level:Connector:Protocol:Connection:Protocol:Connection:Protocol:Connection:Alarm: two potential free contacts (DPDT),Mute Input: TTL logic input with internal pull upConnector DSUB09 femaleHCU : -30°C … 60°C operating (10 minutes warm up at -30°C)SCU: 0°C … 50°C operating, - 30°C … 80°C storage< 95 % non condensingSCU: LCD-Display 2 x 40 characters, 4 cursor keys, 4 function keysHCU: VFD-Display 2 x 40 characters, 4 cursor keys, 4 function keys100 … 240 V AC nominal, 90…264 V AC max, 50…60 HzMax: 33 VA / 20 WTyp: 29 VA / 18 WMains Power Input Connector: IEC C14Mains Fuse:2 x 3.15 A (or 2 A) time-lag fuseDimension <strong>and</strong> Weight: 483 x 44 x 505 mm³ (WxHxD), 1 RU (19")approx. 8.4 kg10 MHz or 5 MHz-3…10 dBminternal, external, auto (senses reference input)BNC female10 MHz0 ± 3 dBmBNC femaleSNMPUDP over Ethernet (10 or 100 Mbps, auto sensing), connector RJ-45HTTP (web browser interface)TCP/IP over Ethernet (10 or 100 Mbps, auto sensing), connector RJ-45MultipointRS232 or RS422/RS485 (configurable), connector DSUB09 female orTCP/IP over Ethernet (10 or 100 Mbps, auto sensing), connector RJ-45Specifications are subject to changeOrder Information:HSBU-[RF B<strong>and</strong>]-[Options] orSSBU-[RF B<strong>and</strong>]-[Options]Possible Options are:FAN (internal Fan)VFD (VFD display, st<strong>and</strong>ard with HCU-type converters)Example: SSBU-K-22012-09-17 31


Synthesized Block DownconverterIndoor VersionSingle B<strong>and</strong> Synthesized Block Downconverter, L-B<strong>and</strong> OutputS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Downconverter Type: HSBD-S / SSBD-S HSBD-C / SSBD-C HSBD-X / SSBD-X HSBD-Ku / SSBD-Ku HSBD-K / SSBD-KRF-Input <strong>Frequency</strong>:S-B<strong>and</strong>2.4 … 2.7 GHzC-B<strong>and</strong>3.4 … 4.2 GHzX-B<strong>and</strong>7.25 … 8.4 GHzKu-B<strong>and</strong>10.70 … 12.75 GHzK-B<strong>and</strong>17.3 … 18.4 GHzRF-Input Return Loss: > 20 dB > 20 dB > 20 dB > 20 dB > 17 dBLO-<strong>Frequency</strong>:3.65 GHzfixed4.90 … 5.15 GHz10 Hz steps6.3 … 6.9 GHz10 Hz steps9.75 … 11,3 GHz10 Hz steps16.35 … 16.90 GHz10 Hz steps-55-50-50-50Phase Noise:10 Hz-601 MHz-112 1) -110 1) -105 1) -105 1) -105 1)100 Hz1 kHz10 kHz100 kHz-75-85-90-100 1)-75-85-95-100 1)-70-80-90-95 1)-70-80-90-95 1)-70-80-90-95 1)max. values in dBc/ Hz1)0°C … 50°C, outside this temperature range degraded by max 5 dB.IF-Output <strong>Frequency</strong>: 0.95 … 1.25 GHz 0.95 … 1.5 GHzConversion Scheme:Single downconversionfrequency inversionSingle downconversionno frequency inversionDownconverter Type: HSBD-Ka / SSBD-Ka HSBD-Ka6 /SSBD-Ka6RF-Input <strong>Frequency</strong>:Ka-B<strong>and</strong>18.3 … 20.6 GHz (lower b<strong>and</strong>)19.7 … 22.0 GHz (upper b<strong>and</strong>)(automatically switched)Ka-B<strong>and</strong>18.1 … 21.2GHzHSBD-Ka7 /SSBD-Ka7Ka-B<strong>and</strong>25.5 … 27.5GHzHSBD-Ka13 /SSBD-Ka13Ka-B<strong>and</strong>21.4 … 22.0GHz-46RF-Input Return Loss: > 17 dB > 17 dB > 17 dB > 17 dBLO-<strong>Frequency</strong>:17.1 … 20.0 GHz10 Hz steps17.15 … 19.45 GHz10 Hz steps24.55 … 25.75 GHz10 Hz steps20.25 GHzfixPhase Noise:10 Hz-47-46-461 MHz-102 1) -101-101-101100 Hz1 kHz10 kHz100 kHz-67-77-87-92 1)-66-76-86-91-66-76-86-91-66-76-86-91max. values in dBc/ Hz1)0°C … 50°C, outside this temperature range degraded by max 5 dB.IF-Output <strong>Frequency</strong>: 1.2 … 2 GHz 0.95 … 1.75 GHz 0.95 … 1.75 GHz 1.15 … 1.75 GHzConversion Scheme:Single downconversion,no frequency inversionRF-Input Characteristics:IF-Output Characteristics:Transfer Characteristics:Impedance:Maximum Aggregate Input Level:LO Leakage:RF-Connector:Impedance:Return Loss:1 dB Compression Point:Output Muting:IF-Connectors:Conversion Gain:Attenuation Range:Gain Accuracy:Gain Flatness over 40 MHz:Image Rejection:Noise Figure:50 10 dBm Ka-b<strong>and</strong>)>60 dBSMA female40 dB St<strong>and</strong>ard30 dB (HSBD/SSBD Ka13)20 dB (HSBD/SSBD Ka7)0…30 dB, 0.1 dB steps (St<strong>and</strong>ard)±1.5 dB (± 3 dB Ka-b<strong>and</strong>) (0°C … 50 °C)± 0.25 dB>80 dB


Synthesized Block DownconverterIndoor VersionSingle B<strong>and</strong> Synthesized Block Downconverter, L-B<strong>and</strong> OutputS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Specifications continued:Reference Input:Reference Output:Test Output LO:(Microwave Oscillator)Monitoring <strong>and</strong> ControlInterface:Alarm Interface:Mute Input:Temperature Range:Relative Humidity:User Interface:Mains Power Input:Mains Power Consumption:Mains Power Input Connector:<strong>Frequency</strong>:Level:Modes:Impedance:Connector:<strong>Frequency</strong>:Level:Impedance:Connector:Level:Impedance:Connector:Protocol:Connection:Protocol:Connection:Protocol:Connection:Alarm: two potential free contacts (DPDT),Mute Input: TTL logic input with internal pull upConnector DSUB09 femaleHSBD: -30°C … 60°C operating (10 minutes warm up at -30°C)SSBD: 0°C … 50°C operating-30°C … 80°C storage


Visit us at www.work-microwave.deSynthesized BlockUp- <strong>and</strong> Downconverter Outdoor VersionS-, C-, X- Ku-, K(DBS)-, Ka B<strong>and</strong>Ka-b<strong>and</strong> modelThese upconverters accepts input signals at L-b<strong>and</strong> orKu-b<strong>and</strong> <strong>and</strong> provide output signals up to Ka-b<strong>and</strong>(27.5 … 31 GHz). The usable b<strong>and</strong>width of up to1600 MHz can be adjusted by a synthesized LO withinthe overall wide frequency range.This design allows high flexibility for multicarrier earthstation operation, while supporting an optimized wideb<strong>and</strong>width <strong>and</strong> providing excellent spurious <strong>and</strong>intermodulation behavior.The converter units can be mounted close by tooutdoor HPAs. A waveguide interface is available foroutput signals in Ka-b<strong>and</strong>.For remote control a remote control unit is available.Key featuresInput frequency: L-b<strong>and</strong> or Ku-b<strong>and</strong>Synthesized LO allows b<strong>and</strong> selection withtypically 10 Hz step size, to adjust the usableoutput frequency rangeOutput power +5 dBm or +10dBm (1 dBcompression point)L-b<strong>and</strong>, Ku-b<strong>and</strong> input: SMA connectorSt<strong>and</strong>ard output: SMAKa-b<strong>and</strong> output: Waveguide connection or KDigital gain compensationReference input 5 or 10 MHz autosensing(Option)Operating temperature range -30°C to 60°C(-22°F to 140°F), storage temperature -50°C to80°C (-58°F to 140°F)Remote control through RS232 <strong>and</strong> RS422/485(2-wire or 4-wire bus) interfacesPacket comm<strong>and</strong> syntax supports RS485 bussystems <strong>and</strong> allows addressed operationSummary alarm output (dual change over switchcontacts) <strong>and</strong> transmit mute inputIP 67 protected housingCE compliant3 years warranty342012-09-17


Synthesized Block UpconverterOutdoor VersionSingle B<strong>and</strong> Synthesized Block Upconverter, L-B<strong>and</strong> Input (Ku-b<strong>and</strong> Input)S-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Upconverter Type: HSBU-K-OD /SSBU-K-ODRF-Output <strong>Frequency</strong>:K-B<strong>and</strong>17.3…18.4 GHzHSBU-K1-OD /SSBU-K1-ODK-B<strong>and</strong>17.3…18.1 GHzHSBU-K-2-OD /SSBU-K-2-ODK-B<strong>and</strong>17.3…18.1 GHz17.6…18.4 GHz(automatically switched)Other b<strong>and</strong>savailable on request as forHSBU / SSBU Indoor units-50-50RF-Output Return Loss: > 17 dB > 17 dB > 17 dBPhase Noise:10 Hz-501 MHz-105 1) -105 1) -105 1)100 Hz1 kHz10 kHz100 kHz-70-80-90-95 1)-70-80-90-95 1)-70-80-90-95 1)max. values in dBc/ Hz1)0°C … 50°C, outside this temperature range degraded by max 5 dB.LO-<strong>Frequency</strong>:15.85…16.65 GHz,10 Hz steps16.05…16.35 GHz,10 Hz steps16,05…16.65 GHz,10 Hz stepsInput-<strong>Frequency</strong>: 1.45 … 1.75 GHz 1.25 … 1.75 GHz 1.25 … 1.75 GHzConversion Scheme:Single up-conversion,no frequency inversionUpconverter Type: HSBU-Ka4-OD HSBU-Ka1-ODRF-Output <strong>Frequency</strong>:Ka-B<strong>and</strong>27.5 … 31.0 GHzKa-B<strong>and</strong>27.5 … 28.6 GHzHSBU-Ka12-OD /SSBU-Ka12-ODKa-B<strong>and</strong>27.5 … 28.25 GHzHSBU-Ka-OD-KuKa-B<strong>and</strong>27.5 … 30.0 GHzRF-Output Return Loss: > 17 dB > 17 dB > 17 dB > 18 dBPhase Noise:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz-46-66-76-86-91-101-46-66-76-86-91-101-46-66-76-86-91-101-47-67-77-87-92-102max. values in dBc/ Hz1)0°C … 50°C, outside this temperature range degraded by max 5 dB.LO2-<strong>Frequency</strong>:36.2 … 39.0 GHz10 Hz steps26.05 … 26.85 GH10 Hz steps z26.5 GHzfixed15.7 … 16.6 GHz10 Hz stepsIntermediate <strong>Frequency</strong>: 8.0 … 8.7 GHz - - -LO1-<strong>Frequency</strong>:: 9.7 GHz - - -Input-<strong>Frequency</strong>: 1.0 … 1.7 GHz 1.45 …1.75 GHz 1.0 … 1.75 GHz 11.8 … 13.4 GHzConversion Scheme:IF-Input Characteristics:RF-Output Characteristics:Transfer Characteristics:Dual up-conversion,no frequency inversionImpedance:Return Loss:Connector Type::Connection Type:1 dB Gain Compression Point:Output Muting:Conversion Gain:Attenuation Range:Gain Accuracy:Level Stability:Amplitude Response:Image Rejection:Noise Figure:Group Delay (± 36 MHz): Ripple, Slope: 15 dBSMA femaleSMA female (St<strong>and</strong>ard)Waveguide WR28, Flange PBR320, Threads M3 (RF Output > 26.5 GHz)K female (RF Output > 18 GHz, RF Output > 26.5 GHz Option K)>5 dBm>10 dBm (HSBU-Ka4-OD)>60 dB (by comm<strong>and</strong> or sense input or by alarm condition)30 dB (St<strong>and</strong>ard)20 dB (HSBU-Ka-OD-Ku, HSBU-Ka4-OD)0 … 30 dB, 0.1 dB steps (St<strong>and</strong>ard)0 dB fixed gain (HSBU-Ka-OD-Ku)±1.5 dB±0.25 dB/day (constant temperature)±0.25 dB / ±20 MHz>80 dB


Synthesized Block UpconverterOutdoor VersionSingle B<strong>and</strong> Synthesized Block Upconverter, L-B<strong>and</strong> Input (Ku-b<strong>and</strong> Input)S-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Specifications continued:Reference Input (Option RIN):Monitoring <strong>and</strong> Control Interface:Temperature Range:<strong>Frequency</strong>:Level:Modes:Connector:Relative Humidity:


Synthesized Block DownconverterOutdoor VersionSingle B<strong>and</strong> Synthesized Block Downconverter, L-B<strong>and</strong> OutputS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Downconverter Type:RF-Input <strong>Frequency</strong>:HSBD-Ku-OD / SSBD-Ku-ODKu-B<strong>and</strong>10.70 … 12.75 GHzOther b<strong>and</strong>s HSBD-Ka7-OD /SSBD-Ka7-ODavailable on request as forHSBU / SSBU Indoor unitsKa-B<strong>and</strong>25.5 … 27.5GHzHSBD-Ka13-OD /SSBD-Ka13-ODKa-B<strong>and</strong>21.4 … 22.0GHzRF-Input Return Loss: > 20 dB > 17 dB > 17 dBLO-<strong>Frequency</strong>:9.75 … 11,3 GHz10 Hz steps24.55 … 25.75 GHz10 Hz steps20.25 GHzfixed-46Phase Noise:10 Hz-50-461 MHz-105 1) -101-101100 Hz1 kHz10 kHz100 kHz-70-80-90-95 1)-66-76-86-91-66-76-86-91max. values in dBc/ Hz1)0°C … 50°C, outside this temperature range degraded by max 5 dB.IF-Output <strong>Frequency</strong>: 0.95 … 1.5 GHz 0.95 … 1.75 GHz 1.15 … 1.75 GHzConversion Scheme:Single downconversion, no frequency inversionRF-Input Characteristics:IF-Output Characteristics:Transfer Characteristics:Impedance:Maximum Aggregate Input Level:LO Leakage:RF-Connector:Impedance:1 dB Compression Point:Output Muting:IF-Connectors:Conversion Gain:Attenuation Range:Gain Accuracy:Gain Flatness over 40 MHz:Image Rejection:Noise Figure:5060 dBSMA female or N female40 dB (St<strong>and</strong>ard)30 dB (HSBD/SSBD Ka13)20 dB (HSBD/SSBD Ka7)0…30 dB, 0.1 dB steps (St<strong>and</strong>ard)± 2 dB (0°C … 50 °C)± 0.25 dB>80 dB


Visit us at www.work-microwave.deL-B<strong>and</strong> Block UpconverterC, X, Ku, K-B<strong>and</strong>Also available as Outdoor VersionSBU-TypeKey features HBU/SBU-TypeLow phase noiseAdjustable attenuator (typ. range: 0 … 20 dB,0.1 dB step size)Output power +10 dBm (1 dB compression point)Low spurious emissionsInternal OCXO with long term stability 10 -7 / yearExternal reference input 5 or 10 MHzLocal control through push buttons on front panel<strong>and</strong> display menuStored alarms with time stampsRemote control through RS232, RS422/485(2-wire or 4-wire) interfaces. Packet comm<strong>and</strong>syntax supports RS485 bus systems <strong>and</strong> allowsaddressed operation.Remote control through Ethernet supporting aTCP/IP comm<strong>and</strong> interface, a Web browserinterface <strong>and</strong> SNMP (MIBs are provided) (IndoorVersion only).Summary alarm output (DPDT)Low power consumption typ. less than 15 WCE compliant3 years warrantySBUL-TypeKey features HBUL/SBUL-TypeLow phase noiseAdjustable attenuator (range: 0 … 19 dB, 1 dBstep size) through attenuator selector on frontpanelOutput power +10 dBm (1 dB compression point)Low spurious emissionsInternal OCXO with long term stability 10 -7 / yearExternal reference input 5 or 10 MHzL-B<strong>and</strong> monitor output on front panel (Option IFT)Summary alarm output (DPDT)RS232 diagnostic interfaceLow power consumption typ. less than 13 WCE compliant3 years warranty382012-09-17


L-B<strong>and</strong> Block UpconverterL-B<strong>and</strong> to C, X, Ku, K-B<strong>and</strong>Upconverter Type: HBU/SBU/SBUL-C HBU/SBU/SBUL-XRF-Output <strong>Frequency</strong>:LO <strong>Frequency</strong>:Phase Noise:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHzC-B<strong>and</strong>5.85 … 6.45 GHzX-B<strong>and</strong>7.90 … 8.40 GHz4.90 GHz 6.95 GHz-58-70-80-89-95-115-58-70-80-89-95-115HBU/SBU/SBUL-Ku1 -HBU/SBU/SBUL-Ku3Ku-B<strong>and</strong>Ku1: 13.75 … 14.50GHzKu3: 12.75 … 13.50GHz12.80 GHz (Ku1)11.80 GHz (Ku3)-58-70-80-85-93-120HBU/SBU/SBUL-K1K-B<strong>and</strong>17.30 … 18.10 GHzHBU/SBU-K-2K-B<strong>and</strong>17.30 … 17.95 GHz17.75 … 18.40 GHz16.35 GHz 15.90 / 16.35 GHzswitchablemax values in dBc/HzIF-Input <strong>Frequency</strong> 950 … 1550 MHz 950 … 1450 MHz 950 … 1700 MHz 950 … 1750 MHz 1400 … 2050 MHzConversion Scheme:Block up conversion, no frequency inversionIF-Input Characteristics:IF-Monitor (Option IFT):RF-Output Characteristics:Transfer Characteristics:Impedance:Return Loss:Connector:Signal level in reference to input:Impedance:Connector:Impedance:Return Loss:1 dB Compression Point:Output Muting:Connectors:Max Conversion Gain:Attenuation range:Gain Variation over Temp.:Gain Flatness over Freq.:Gain Flatness over 40 MHz:Image Rejection:Noise Figure:Group Delay: Ripple, Slope: 18 dBSMA female (Indoor Version)N female (Outdoor Version)-20 dB50SMA (female)50>18 dB>10 dBm>75 dB (by comm<strong>and</strong> or sense input or by alarm condition)SMA (female)35 dB0…20 dB, 0.1 dB steps (HBU/SBU)0…19 dB, 1 dB steps (HBUL/SBUL)±1 dB max±1.5 dB max. over b<strong>and</strong>±0.5 dB>80 dB


L-B<strong>and</strong> Block UpconverterL-B<strong>and</strong> to C, X, Ku, K-B<strong>and</strong>Specifications continued:User Interface SBU:User Interface SBUL:Mains Power Input:Mains Power Consumption:LCD-Display 2 x 40 characters, 4 cursor keys, 4 function keysVFD-Display 2 x 40 characters, 4 cursor keys, 4 function keys (HBU, option: VFD for SBU)Attenuator selector on front panel100 … 240 V AC nominal, 90…264 V AC max, 50…60 HzMax: 25 VA / 15 WMax: 33 VA / 24 W (SBU-K-2)Indoor VersionIndoor VersionMains Power Input Connector: IEC C14 Indoor VersionAmphenol C16-1 (3+PE) maleOutdoor VersionMains Fuse: 2 x 2 A time-lag fuse Indoor Version onlyDimension <strong>and</strong> Weight: 483 x 44 x 270 mm 3 (WxHxD), 1 RU (19")approx. 6 kgIndoor Version402 x 111 x 391 mm 3 (WxHxD)approx. 8 kgOutdoor VersionSpecifications are subject to changeOrder Information:HBU/SBU-[RF B<strong>and</strong>]-[Options] or HBUL/SBUL-[RF B<strong>and</strong>]-[Options]Possible Options are:Example: SBU-Ku1 (Ku-B<strong>and</strong> 1)VFD (VFD display for SBU indoor unit)IFT (IF Monitor on Frontpanel)OD (Outdoor Unit, HBU only)FAN (Indoor Unit only)Dimensions of Outdoor Housing402012-09-17


L-B<strong>and</strong> Block DownconverterC, X, Ku-B<strong>and</strong> Input, L-B<strong>and</strong> OutputAlso available as Outdoor VersionSBD-TypeKey features HBD/SBD-TypeLow phase noiseAdjustable attenuator (range: 0…20 dB, 0.1 dBstep size)Output power +10 dBm (1 dB compression point)Low spurious emissionsInternal OCXO with long term stability 10 -7 / yearExternal reference input 5 or 10 MHzLocal control through push buttons on front panel<strong>and</strong> display menuStored alarms with time stampsRemote control through RS232, RS422/48 (2-wireor 4-wire) interfaces. Packet comm<strong>and</strong> syntaxsupports RS485 bus systems <strong>and</strong> allowsaddressed operation.Remote control through Ethernet supporting aTCP/IP comm<strong>and</strong> interface, a Web browserinterface <strong>and</strong> SNMP (MIBs are provided) (IndoorVersion only).Summary alarm output (DPDT)Low power consumption typ. less than 15 WCE compliant3 years warrantySBDL-TypeKey features HBDL/SBDL-TypeLow phase noiseAdjustable attenuator (range: 0…19 dB, 1 dB stepsize) through attenuator selector on front panelOutput power +10 dBm (1 dB compression point)Low spurious emissionsInternal OCXO with long term stability 10 -7 / yearExternal reference input 5 or 10 MHzL-B<strong>and</strong> monitor output on front panelSummary alarm output (DPDT)RS232 diagnostic interfaceLow power consumption typ. less than 13 WCE compliant3 years warranty2012-09-17 41


L-B<strong>and</strong> Block DownconverterC, X, Ku, K-B<strong>and</strong> to L-B<strong>and</strong>Downconverter Type: HBD/SBD/SBDL-C HBD/SBD/SBDL-X HBD/SBD/SBDL-Ku1 HBD/SBD/SBDL-Ku2 HBD/SBD/SBDL-Ku3RF-Input <strong>Frequency</strong>:C-B<strong>and</strong>3.4 … 4.2 GHzX-B<strong>and</strong>7.25 … 7.75 GHzKu-B<strong>and</strong>10.95 … 11.7 GHzKu-B<strong>and</strong>10.7 … 11.7 GHzKu-B<strong>and</strong>11.7 … 12.75 GHzLO <strong>Frequency</strong>: 5.15 GHz 6.30 GHz 10.00 GHz 9.75 GHz 10.75 GHzPhase Noise:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz-58-70-80-89-95-115max values in dBc/Hz-58-70-80-89-95-115IF-Output <strong>Frequency</strong>: 950 … 1750 MHz 950 … 1450 MHz 950 … 1700 MHz 950 … 1950 MHz 950 … 2000 MHzConversion Scheme: frequency inversion no frequency inversion-54-66-76-85-93-115-54-66-76-85-93-115-54-66-76-85-93-115Downconverter Type:RF-Input <strong>Frequency</strong>:SBD2/SBDL2-Ku2Ku3Dual Channel Converter, including one RF input with signal splitter, two IF OutputsKu-B<strong>and</strong>10.70 … 11.70 GHzKu-B<strong>and</strong>11.70 … 12.75 GHzLO <strong>Frequency</strong>: 9.75 GHz 10.75 GHzPhase Noise:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHzmax values in dBc/Hz-54-66-76-85-93-115IF-Output <strong>Frequency</strong>: 950 … 1950 MHz 950 … 2000 MHzConversion Scheme:no frequency inversion-54-66-76-85-93-115RF-Input Characteristics:IF-Output Characteristics:Transfer Characteristics:Impedance:Return Loss:Maximum Aggregate Input Level:LO Leakage:RF-Connector:Impedance:Return Loss:1 dB Compression Point:IF-Connectors:Max Conversion Gain:Attenuation range:Gain Accuracy:Gain Variation over Temp.:Gain Flatness over Freq.:Gain Flatness over 40 MHz:Image Rejection:Noise Figure:50>18 dB-25 dBm (operational)5 dBm (damage level)18 dB>17 dBmSMA female (Indoor Version)N female (Outdoor Version)35 dB0…20 dB, 0.1 dB steps (HBD/SBD)0…19 dB, 1 dB steps (HBDL/SBDL)±1.5 dB (0°C … 50 °C)±1 dB±1.5 dB over b<strong>and</strong>±0.5 dB>80 dB


L-B<strong>and</strong> Block DownconverterC, X, Ku, K-B<strong>and</strong> to L-B<strong>and</strong>Specifications continued:Diagnostic Interface(HBUL/SBUL only):Alarm Interface:Combined Monitoring <strong>and</strong> ControlInterface <strong>and</strong> Alarm Interface:Temperature Range:RS232, connector DSUB09 femaleAlarm: two potential free contacts (DPDT),Connector DSUB09 femaleRS232 or RS422/RS485, Multipoint packet format comm<strong>and</strong>sAlarm output: Two potential free contacts (DPDT)24 V DC output: max 0,3 A6,5 V DC output: max 0,2 AMute Input: TTL logic input with internal pull upConnector type: MIL-C-26482: MS 3120 E 14-19 SHCU: -30°C … 60°C operating (10 minutes warm up at -30°C)SCU: 0°C … 50°C operating, - 30°C … 80°C storageIndoor VersionHBUL/SBUL onlyIndoor VersionOutdoor VersionRelative Humidity: < 95 % non condensing Indoor Version< 100 % Outdoor VersionUser Interface SBU:LCD-Display 2 x 40 characters, 4 cursor keys, 4 function keysVFD-Display 2 x 40 characters, 4 cursor keys, 4 function keys (HBU, option: VFD for SBU)Indoor VersionUser Interface SBUL:Attenuator selector on front panelIndoor VersionMains Power Input:100 … 240 V AC nominal, 90…264 V AC max, 50…60 HzMains Power Consumption: Max: 25 VA / 15 WMains Power Input Connector: IEC C14 Indoor VersionAmphenol C16-1 (3+PE) maleOutdoor VersionMains Fuse: 2 x 3.15 A (or 2 A) time-lag fuse Indoor Version onlyDimension <strong>and</strong> Weight: 483 x 44 x 310 mm 3 (WxHxD), 1 RU (19")approx. 6 kgIndoor Version402 x 111 x 391 mm 3 (WxHxD)approx. 8 kgOutdoor VersionSpecifications are subject to changeOrder Information:HBD/SBD-[RF B<strong>and</strong>]-[Options] or HBDL/SBDL-[RF B<strong>and</strong>]-[Options]Possible Options are:VFD (VFD display for SBD indoor unit)OD (Outdoor Unit, HBD only)Example: SBD-Ku1 (Ku-B<strong>and</strong> 1)Dimensions of Outdoor Housing2012-09-17 43


Narrowb<strong>and</strong> Block DownconverterIndoor VersionBlock Downconverter C-B<strong>and</strong> Input, L-B<strong>and</strong> Output, Fixed GainDownconverter Type: BD-C BD-XRF-Input <strong>Frequency</strong>: 3.5…3.7 GHz 7.9…8.4 GHzConversion Scheme: Single down-conversion, frequency inversion Single down-conversion, no frequency inversionLO <strong>Frequency</strong>: 5.154 GHz 5.75 GHzPhase Noise:RF-Input Characteristics:IF-Output Characteristics:Transfer Characteristics:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz-56 dBc/Hz-62 dBc/Hz-111 dBc/Hz 1) -111 dBc/Hz 1)-83 dBc/Hz-89 dBc/Hz-101 dBc/Hz-104 dBc/Hz 1)-76 dBc/Hz-86 dBc/Hz-96 dBc/Hz-101 dBc/Hz 1)max values in dBc/Hz1)0°C … 50°C, outside this temperature range degraded by max 5 dB.Impedance:50Return Loss:>20 dB (VSWR = 1.22)Maximum Aggregate Input Level:


Visit us at www.work-microwave.deSatellite Block-Upconverter (mini-buc)Single / Dual / Triple B<strong>and</strong>L-B<strong>and</strong> to C, X, Ku-B<strong>and</strong>Modular concept with arbitrary combinations of output frequenciesModuleSize: 140x100x17 mmWeight: 400 g(Rack Mount- <strong>and</strong> Outdoor-Housings are also available)The mini-buc series of WORK Microwave sets higherst<strong>and</strong>ards in modern block converter technology. Theusage of integrated circuits provides a most reliable<strong>and</strong> extremely compact design with very low powerconsumption <strong>and</strong> good phase noise. DROs <strong>and</strong> othercritical parts were replaced by MMICs. All mini-bucsare equipped with internal gain control. A built inmicrocontroller provides an interface to external M&Csystems.Due to the lightweight rugged design, non sensitiveagainst shock <strong>and</strong> vibrations, these BUCs can beimplemented almost everywhere, e.g. in TWTAs <strong>and</strong>SSPAs for mobile L<strong>and</strong>, Sea <strong>and</strong> Airborne systems.They can be used in satellite news gathering (SNG)terminals as well as mobile satellite communicationequipment (Fly-Aways).19” Rack Mount HousingsWORK Microwave’s mini-bucs are also availablewithin a st<strong>and</strong>ard 19" rack mount housing for easyrack integration.Outdoor HousingsThe mini-bucs are also available within an outdoorhousing, which can be mounted directly at theantenna.Key featuresHigh integrated MMIC technologyLow phase noiseOptional OCXO with long term stability 10 -7 / year(with separate module SMBU/HMBU-OCXO)Output power +10 dBm (1 dB compression point)Low spurious emissionsLow power consumption typ. less than 6 WOperating temperature range up to -30°C to+60°CReference input through IF interface (st<strong>and</strong>ard) orMMCX Connector (option RIN)Remote control through RS422/485 (RS 232option), (with separate module SMBU/HMBU-OCXO RS232 or RS422/485Packet comm<strong>and</strong> syntax supports 2-wire or 4-wirebus systems <strong>and</strong> allows addressed operationSummary alarm output (DPDT) (with separatemodule SMBU/HMBU-OCXO)Transmit mute inputAdjustable gain control (range: 20 dB)Can be cascaded to multi converter configurationsHigh reliability, Low cost2012-09-17 45


Visit us at www.work-microwave.deSatellite Block-Upconverter (mini-buc)Single / Dual / Triple B<strong>and</strong>L-B<strong>and</strong> to C, X, Ku-B<strong>and</strong>Dual b<strong>and</strong> mini-buc:Size: 140x100x34 mmWeight: 800 gTriple b<strong>and</strong> mini-buc:Size: 140x100x51 mmWeight: 1200 gRF OUTC-B<strong>and</strong>C-B<strong>and</strong>mini-bucSMBU-CL-B<strong>and</strong> + 5/10 MHz ext.Ref. (opt.) + DC (opt.)5/10 MHz ext.Ref. (opt.)C-B<strong>and</strong> ONX-B<strong>and</strong> ONKu-B<strong>and</strong> ONDC Supply voltage 12..24VAlarmSUB-D9RS232 / 485ReferenceModuleMBU-OCXOUbI2Cmini-bucSMBU-XRF OUTX-B<strong>and</strong>RF OUTKu-B<strong>and</strong>mini-bucSMBU-KuRF OUTKu-B<strong>and</strong>L-B<strong>and</strong> + 10 MHz Ref.L-B<strong>and</strong> + 10 MHz Ref.L-B<strong>and</strong> + 10 MHz Ref.Relay ControlBlock diagram of Triple b<strong>and</strong> configuration with reference module462012-09-17


Satellite Block-Upconverter (mini-buc)ModulesSingle / Dual / Triple B<strong>and</strong> L-B<strong>and</strong> to C, X, Ku-B<strong>and</strong>S-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Single B<strong>and</strong> Type: SMBU-C, SMBU-X, SMBU-Ku or HMBU-C, HMBU-X, HMBU-KuDual B<strong>and</strong> Type: SMBU-CX, SMBU-CKu, SMBU-XKu or HMBU-CX, HMBU-CKu , HMBU-XKu1 )Triple B<strong>and</strong> Type: SMBU-CXKu or HMBU-CXKuRF-Output <strong>Frequency</strong>:LO <strong>Frequency</strong>:Phase Noise:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHzC-B<strong>and</strong>5.850…6.450 GHzX-B<strong>and</strong>7.9…8.4 GHz4.9 GHz 6.95 GHz-58-70-80-89-95-115-58-70-80-89-95-115max values in dBc/Hz1 )Ku-B<strong>and</strong>Ku1: 13.75…14.50 GHzKu3: 12.75…13.50 GHz12.8 GHz (Ku1)11.8 GHz (Ku3)IF-Input <strong>Frequency</strong> 950 … 1550 MHz 950 … 1450 MHz 950 … 1700 MHzConversion Scheme:Block up conversion, no frequency inversionIF-Input Characteristics:RF-Output Characteristics:Transfer Characteristics:Impedance:Return Loss:Connector:Impedance:Return Loss:1 dB Compression Point:Output Muting:Connectors:Max Conversion Gain:Attenuation range:Gain Variation over Temp.:Gain Flatness over Freq.:Gain Flatness over 40 MHz:Image Rejection:Noise Figure:Group Delay: Ripple, Slope: 18 dBSMA (female)50>18 dB>10 dBm 80 dB< 15 dB


Satellite Block-Upconverter (mini-buc)ModulesSingle / Dual / Triple B<strong>and</strong> L-B<strong>and</strong> to C, X, Ku-B<strong>and</strong>S-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Order Information:SMBU-[RF B<strong>and</strong>(s)] orHMBU [RF B<strong>and</strong>(s)]Possible Options are:Examples:LG (Low Gain)RIN (Ref input via MMCX Connector instead of IF input)RS232 (Remote control through RS232 instead of RS422/485)IDU (mounted in 19” rack housing, no power supply, no local control)ODU (mounted in outdoor housing, no power supply, no local control)OD (mounted in outdoor housing, with power supply, no local control)SMBU-CXKu1 (Triple b<strong>and</strong> minibuc, SMBU-OCXO <strong>and</strong> rf-relay are included)HMBU-Ku (Single b<strong>and</strong> Ku-B<strong>and</strong> minibuc, extended temperature)SMBU-Ku-LG (Single b<strong>and</strong> Ku-B<strong>and</strong> minibuc, low gain)482012-09-17


Block-Converter Reference Module10 MHz Reference- <strong>and</strong> Main-Module for mini-bucS-Type (st<strong>and</strong>ard version), H-Type (extended temperature range)Type:SMBU-OCXO or HMBU-OCXOOCXO Phase NoiseReference Output:External Reference Input:10 Hz100 Hz1 kHz10 kHz100 kHz1 MHz<strong>Frequency</strong>:Level:Connector:<strong>Frequency</strong>:Level:Connector:Mode:-115 dBc/Hz max.-136 dBc/Hz max.-147 dBc/Hz max.-152 dBc/Hz max.-159 dBc/Hz max.-161 dBc/Hz max.10 MHz3 dBm 1 dBmSMA5 or 10 MHz ± 0.4 ppm5 dBm ± 5 dBmSMAautoInternal frequency Stability: ± 1 x 10 -7 , 0°C … 50°C± 2 x 10 -8 , 0°C … 50°C (after 30 min warm up)± 1.5 x 10 -9 per day (fixed temperature after 24 h warm up)IF-Input Characteristics:IF-Output Characteristics:IF Transfer Characteristics:Relay Driver:Monitoring <strong>and</strong> ControlInterface:Alarm-Output:Temperature Range:Relative Humidity:Power Input:Power Consumption:Dimension <strong>and</strong> Weight:Low Pressure/Altitude:Shock/Vibration:<strong>Frequency</strong>:Impedance:Return Loss:Connector:<strong>Frequency</strong>:Impedance:Return Loss:Connector:Max Loss:Support of two RF relaysProtocol:Connection:Two potential free contacts (DPDT)950 MHz…1700 MHz50>15 dBSMA (female)950 MHz…1700 MHz50> 15 dBSMA (female)2 dBincludes switch for IF-signalMultipointRS422/RS485 or RS232SMBU-OCXO: 0°C … 50°C operationalHMBU-OCXO: -30°C … 60°C operational-46°C … 73°C storage


Visit us at www.work-microwave.deRemote Control UnitSatellite Uplink Power Control UnitThis remote control unit is mainly useful for remotecontrol of outdoor converter units. The unit is powerednormally remotely from the outdoor unit. The frontpanel allows to manually control the configuration ofan outdoor converter in a similar way as it is possiblefor indoor converter units.Also versions to control more than one converter fromthe same unit are available (Options Dual <strong>and</strong> Multi).These units include an internal power supply.Remote control of the complete setup via RS232,RS485 or IP over Ethernet is possible at this controlunit, also alarm relay outputs are provided. For theconnection to the outdoor unit or to the remotecontrolled unit in general, an RS485 connection isused.As option this unit is also available for st<strong>and</strong>ard rackmount converters. In this case the unit includes itsown power supply. The option internal power supplycan also be used to provide power to controlled units,which do not have any own power supply.Uplink Power ControlUplink Power Control is a hardware <strong>and</strong> softwareoption for the Remote Control Unit.The Uplink Power Control senses a DC signal from abeacon receiver. If due to additional atmosphericattenuation caused by rain, snow, clouds or fog oralso due to antenna misalignment the beacon signal isattenuated, the transmitted signal is increasedproportionally until a configurable maximum additionalgain is reached or the maximum gain of theupconverter is reached.The uplink power control has the following interfacefor the DC signal from the beacon receiver:Connector type:DSUB-9, maleDC voltage range: 0 … 10 VInput for lock signal/alarm signal from the beaconreceiverThe following Operational Parameters can be configured:Uplink power control on/offMaximum gain increase in reference to clear skygainSampling <strong>and</strong> update period in secondsRatio between decrease of beacon signal <strong>and</strong>increase of transmission signal (due to differenceof rain attenuation effect for different frequencies)Up to 5 DC values for beacon signal strength canbe entered as reference points for linearinterpolation (characteristic of beacon receiver).Clear sky value of DC beacon receiver signalSustain period in seconds (up 3600 seconds) forwhich the uplink power control keeps the last gainincrease value (in case of deep fade conditionswhere the beacon receiver can lose lock for someperiod of time).The following Specifications can be monitored:DC signal from beacon receiverCalculated attenuation of beacon signalCurrent gain increase of transmission signal(theoretical value only if the uplink power controlmode is off)502012-09-17


Remote Control UnitSatellite Uplink Power Control UnitModelMonitoring <strong>and</strong> ControlInterface:Internal Monitor <strong>and</strong> ControlInterface to controlled unit(s):RC-CORemote Control for Outdoor UnitsRC-CIRemote Control for Indoor UnitsRS232 or RS422/RS485 (Connectors DSUB09 female) (selectable by customer), IP over EthernetSt<strong>and</strong>ard:RS422/RS485Alarm signalDC Supply from ODU 12…24 VConnector DSUB25 maleOption PS:RS422/RS485Alarm signalDC Supply to ODU 24 VConnector DSUB25 femaleRS422/RS485Connector DSUB09 femaleTemperature Range:Relative Humidity:User Interface:Option Dual/Multi:RS422/RS485Connector DSUB09 female-30°C … 60°C operating (the LCD display is operational: -20°C … 60°C)-30°C … 80°C storage< 95% non condensingLCD, 2 x 40 characters, 4 cursor keys, 2 function keysMains Power Input:Option PS, Dual, Multi:100 … 240 V AC nominal, 90…264 V AC max50…60 HzOption PS can supply DC power from remote control toconverter unitMains Power Consumption: Option PS, Dual, Multi:Typ: 10 VA / 6 W, Max: 55WMains Power Input Connector: IEC C14Mains Fuse:2.0 A time-lag fuseDimension <strong>and</strong> Weight: 483 x 44 x 270 mm³ (WxHxD), 1 RU (19")approx. 4 kg100 … 240 V AC nominal, 90…264 V AC max50…60 HzTyp: 10 VA / 6 WSpecifications are subject to changeOrder Information:RC-CO-[Options] orRC-CI-[Options]Possible Options are:Examples:RC-CORC-CIRC-CO-UPCRC-CO-PSUPC (Uplink power control)UPC/TS (Uplink power control with temperature sensor)PS (Power supply on RC-CO)DUAL (Remote Control for two frequency converters)MULTI (Remote Control for up to 8 frequency converters)T (Remote Control for dual channel tracking converters)2012-09-17 51


Visit us at www.work-microwave.deSatellite ConverterAutomatic Level Control (ALC)Filter AmplifierWORK Microwave delivers as st<strong>and</strong>-alone unit oroptionally within downconverters application specificALC Filter Amplifiers. The picture above shows ast<strong>and</strong>-alone unit.The input of this unit can be connected to the IFoutput of the downconverter.The picture below shows a block diagram of theapplication specific ALC Filter Amplifier. The signal isb<strong>and</strong>pass filtered on the input as well as on theoutput. Both b<strong>and</strong>pass filters are identical.The pictures on the next page show typical amplitudefrequency responses of such filters. The overall filtercharacteristic of the complete unit results from aseries connection of the two identical filters, doublingall attenuation values in dB, which means that e.g. astop-b<strong>and</strong> suppression of 50 dB for one filter results ina overall stop-b<strong>and</strong> suppression for the complete unitof about 100 dB (for the same frequency point).In between these filters a variable gain stage allowsadjustment of the signal level. A small portion of theoutput signal level is coupled to an RMS detector.A digitally implemented control algorithm using amicroprocessor allows to select a specified outputlevel <strong>and</strong> keeps the output level constant, even if theinput signal varies within the allowed level range. Theoperational parameters of the ALC amplifier can beconfigured from the front panel processor as well asfrom remote. Also monitoring of the ALC amplifier ispossible from the front panel processor as well asfrom remote. Besides the main ALC output an ALCMonitor Output is available on the rear panel.ALC Input140 MHzB<strong>and</strong>pass140 MHzB<strong>and</strong>passALC OutputALC Monitor140 MHzALCControllerADCFront PanelController522012-09-17


Satellite ConverterAutomatic Level Control (ALC) Filter AmplifierTypical Amplitude-<strong>Frequency</strong> Response ofone 140 MHz B<strong>and</strong>pass Filter with 34 MHzB<strong>and</strong>width.Typical Amplitude-<strong>Frequency</strong> Response ofone 140 MHz B<strong>and</strong>pass Filter with 54 MHzB<strong>and</strong>width.Typical Amplitude-<strong>Frequency</strong> Response ofone 140 MHz B<strong>and</strong>pass Filter with 75 MHzB<strong>and</strong>width.Typical Amplitude-<strong>Frequency</strong> Response ofone 140 MHz B<strong>and</strong>pass Filter with 110 MHzB<strong>and</strong>width.2012-09-17 53


Satellite ConverterAutomatic Level Control (ALC) Filter AmplifierIF Input:IF Output:IF Monitor Output:Transfer Characteristics:Center <strong>Frequency</strong>:<strong>Frequency</strong> Range:Signal Level:Return Loss:Connector:Impedance:Center <strong>Frequency</strong>:B<strong>and</strong>width:Signal Level:Return Loss:Connector:Impedance:Signal similar to IF OutputSignal Level:Return Loss:Connector:Impedance:Gain:Group delay:B<strong>and</strong>width:<strong>Frequency</strong> Range:Interrmodulation (3 rd Order): 18 dB (within filter passb<strong>and</strong> b<strong>and</strong>width)SMA female50140 MHz34 MHz or 54 MHz or 75 MHz or 110 MHz-5 dBm …10 dBm (adjustable, 0.1 dB step size)>18 dB (within filter passb<strong>and</strong> b<strong>and</strong>width)SMA female5020 dB lower than IF Output>20 dBSMA female5015 … 60 dB (automatically or manual adjustable, 0.1 dB step size) configurable value (0.1 … 5 dB)with configurable time constant up to 1000 s.Gradual adjustment for required gain adjustment < configurable value (0.1 … 5 dB)with configurable time constant up to 1000 sControl cycle approx. 100 ms.No interruption of the signal during adjustment.Ethernet/IP (10 or 100 Mbps, auto sensing)RS232 or RS422/RS485 (Connectors DSUB09 female) (configurable)Two potential free contacts (DPDT, Connector DSUB09 female)-25°C … 60°C operatingthe LCD display is operational: -20°C … 60°C-30°C … 80°C storage


Visit us at www.work-microwave.deRedundancy Switch 1:1Redundancy Controller 1:1RSCM1The WORK Microwave Redundancy Switch 1:1 isused for 1:1 redundancy configurations for upconverters,downconverters, modulator-upconverters,transportstream- modulators, demodulators <strong>and</strong>modems. It includes typically a coaxial signal splitterfor the input signal <strong>and</strong> a coaxial signal switch for theoutput signal. Optional also an input signal switchinstead of the signal splitter is available. For IPmodem applications a similar device of type RSCI1 isavailable.LNAs or even HPAs can be included wit.hin thesystem, as the switch is capable to control externalwaveguide transfer switches as option. DC power toLNAs can be provided also as option. The switchaccepts alarm signals from 2 types of equipment, sothat it can be used for redundancy configurations withe.g. a video encoder <strong>and</strong> a modulator within onechain.The units can be controlled from the front panel orremotely via RS 232, RS422/485 or IP over Ethernet.The unit can operate in automatic mode, were anautomatic switchover to the st<strong>and</strong> by unit is performedupon detection of an alarm of the active unit. Also amanual switchover to the st<strong>and</strong>by unit can be initiated.Two power supplies <strong>and</strong> two AC input connectorsguarantee very high availability of the unit.The 1:1 redundancy is also available in an outdoorversion, where the signal splitter <strong>and</strong> the signaltransfer relay is mounted within an outdoor switchbox. The control unit is similar to the indoorredundancy controller, but does not include any signalsplitters or signals switches the outdoor switch boxalso includes interfaces for alarms <strong>and</strong> M&C ofoutdoor units. A control cable runs from the outdoorswitch box to the indoor redundancy controller.to Summary AlarmINSignalSplitterRS232 / RS485 /TCP/IP over EthernetRemote ControlHCU/SCUHCD/SCDHMCU/SMCUHCU/SCUHCD/SCDHMCU/SMCUAlarmAlarmControlLogicRS232 / RS485 /TCP/IP over EthernetRemote ControlSignalSwitchOutTest Out1:1 Redundancy with Signal Splitter2012-09-17 55


Redundancy Switch 1:1ModelControl Interface to OutdoorSwitch Box RSB1-xx-xx:Signal Input SplitterRSCM1-50K-xxSignal Input SplitterRSCM1-50C-xxSignal Input SplitterRSCM1-50L-xxSignal Input SplitterRSCM1-50V-xxSignal Input SplitterRSCM1-75V-xxSignal Input or OutputTransfer SwitchRSCM1-50KT-xxRSCM1-xx-50KSwitching:Remote M&C Interface:Summary Alarm Interface:Internal M&C Interface:Configuration:-RSCM1-xx-xxRedundancy Switch 1:1Connector type:3 x SMA femaleImpedance: 50Power h<strong>and</strong>ling:3 W<strong>Frequency</strong> Range:6 …18 GHzInsertion loss:14 dBAmplitude balance:0.4 dBConnector type:3 x SMA femaleImpedance: 50Power h<strong>and</strong>ling:3 W<strong>Frequency</strong> Range:4 … 8 GHzInsertion loss:15 dBAmplitude balance:0.4 dBConnector type:3 x SMA femaleImpedance: 50Power h<strong>and</strong>ling:3 W<strong>Frequency</strong> Range:950 … 2000 MHzInsertion loss:17 dBAmplitude balance:0.3 dBConnector type:3 x BNC femaleImpedance: 50Power h<strong>and</strong>ling:1 W<strong>Frequency</strong> Range:5 … 300 MHzInsertion loss:15 dBAmplitude balance:0.4 dBConnector type:3 x BNC femaleImpedance: 75Power h<strong>and</strong>ling:1 W<strong>Frequency</strong> Range:5 … 300 MHzInsertion loss:15 dBAmplitude balance:0.4 dBConnector type:4 x SMA femaleImpedance: 50Power h<strong>and</strong>ling:1 W (switching)<strong>Frequency</strong> Range:0 … 18 GHzInsertion loss:60 dB (12 … 18 GHz)Return loss:>26 dB (0 … 1 GHz)>21 dB (1 … 4 GHz)>16 dB (4 … 8 GHz)>15 dB (8 … 12 GHz)>14 dB (12 … 18 GHz)Manual or AutomaticProtocol:Connection:Protocol:Connection:Protocol:Connection:RSCM1-ODRedundancy Controller 1:1for outdoor switch box RSB1-xx-xxAlarm inputs, control outputs(Connector DSUB15 female)SNMPUDP over Ethernet (10 or 100 Mbps, auto sensing), connector RJ-45HTTP (web browser interface)TCP/IP over Ethernet (10 or 100 Mbps, auto sensing), connector RJ-45MultipointRS232 or RS422/RS485 (configurable), connector DSUB09 female orTCP/IP over Ethernet (10 or 100 Mbps, auto sensing), connector RJ-45Two potential free contacts (DPDT, Connector DSUB09 female)RS485 (Connector DSUB09 male)16 DIP switches on rear side / serial interfaceSpecifications continued next page562012-09-17


Redundancy Switch 1:1Redundancy Controller 1:1Specifications continued:Temperature Range:Relative Humidity:User Interface:Mains Power Input:Mains Power Consumption:Mains Power Input Connector:-30°C … 60°C operating-30°C … 80°C storage


Outdoor Redundancy Switch Unit 1:1ModelSignal Input SplitterRSB1-50K-xxSignal Input SplitterRSB1-50C-xxSignal Input SplitterRSB1-50L-xxSignal Input SplitterRSB1-75V-xxSignal Input or OutputTransfer SwitchRSB1-50KT-xxRSB1-xx-50KSwitching:Control Interface to IndoorControl Unit RSCM1-OD:Alarm Interface to ConverterUnits:Temperature Range:RSB1-xx-xxOutdoor Switch Unit 1:1Connector type:3 x N femaleImpedance: 50Power h<strong>and</strong>ling:3 W<strong>Frequency</strong> Range:6 … 18 GHzInsertion loss: 13 dBAmplitude balance:0.4 dBConnector type:3 x N femaleImpedance: 50Power h<strong>and</strong>ling:3 W<strong>Frequency</strong> Range:4 … 8 GHzInsertion loss:14 dBAmplitude balance:0.4 dBConnector type:3 x N femaleImpedance: 50Power h<strong>and</strong>ling:3 W<strong>Frequency</strong> Range:950 … 2000 MHzInsertion loss:17 dBAmplitude balance:0.3 dBConnector type:3 x N femaleImpedance: 75Power h<strong>and</strong>ling:1 W<strong>Frequency</strong> Range:5 … 300 MHzInsertion loss:14 dBAmplitude balance:0.4 dBConnector type:4 x SMA femaleImpedance: 50Power h<strong>and</strong>ling:1 W (switching)<strong>Frequency</strong> Range:Insertion loss:Isolation:Return LossRelative Humidity: 20 dB (0 … 1 GHz)>17 dB (1 … 4 GHz)>15 dB (4 … 8 GHz)>14 dB (8 … 12 GHz)>12 dB (12 … 18 GHz)Alarms, control signals(Connector Type: MIL-C-26482: MS 3120 E 14-26 S)2 Interfaces to sense contact closures at alarm outputs of converter units <strong>and</strong> for internal M&C (RS485)(Connector Type: MIL-C-26482: MS 3120 E 12-19 P)-30°C … 60°C operating-30°C … 80°C storage190 x 100 x 190 mm³ (WxHxD)approx. 2 kgDegree of Protection: IP 67 (acc. IEC 529)Specifications are subject to changeOrder Information:RSB1-[Input Splitter or Switch Type]-[Output Switch Type]Example:RSB1-75V-50K582012-09-17


Redundancy Switch 1:1 for IP ModemsRSCI1This version of a WORK Microwave 1:1 RedundancySwitch is specifically designed for IP modems <strong>and</strong> IPdemodulators. Besides this type also a st<strong>and</strong>ard1:1 Redundancy Switch RSCM1 is available, whichcan be used for modulators, demodulators <strong>and</strong>modems with ASI transport stream inputs <strong>and</strong> outputs.The 1:1 Redundancy Switch RSCI1 includes for theGigabit Ethernet traffic interfaces a special type ofform C (SPDT) Ethernet switch with RJ45 interfaces,to allow switchover from one IP modem or IPdemodulator to the redundant one. This operatestogether with MAC address announcing methods,initiated automatically by the Gigabit Ethernet trafficinterfaces: The IP Modulator who detects that a port isa getting active (after switchover) sends a broadcastmessage that the MAC Address has changed.Equipment receiving this message, typically the nextrouter, needs to react to this message <strong>and</strong> update itsARP resolution table. This is in IPv4 an extension toRFC 826 <strong>and</strong> is called Gratuitous ARP. For IPv6 it isdefined by RFC 4861, clause 7.2.6 <strong>and</strong> is calledUnsolicited Neighbor Advertisement. The downtimeafter switchover is approximately less than 5 sec,typically only 2-3 sec <strong>and</strong> depends mainly on theEthernet auto negotiation time.Both IP modems or IP demodulators need to beconfigured in the same way, have different MACAddresses, but the same IP Address.For the RF transmit signal a transfer relay is included.For the RF receive signal also a transfer relay orpreferably a signal splitter is available, which can bemounted externally to the unit. For L-B<strong>and</strong> receivesignals also a special signal splitter with integratedswitch is available, which allows to provide DC <strong>and</strong> a22 kHz tone signal always from the active unit to theLNB.The 1:1 Redundancy Switch accepts alarm signalsfrom the two IP devices. The unit can operate inautomatic mode, were an automatic switchover to thest<strong>and</strong> by unit is performed upon detection of an alarmof the active unit.For configurations including a splitter on the receivesignal side, where both IP devices can receive the RFsignal, also monitoring of the receive conditions ofboth units is implemented. A switchover is performedin case that, with automatic mode enabled, the activeunit indicates a non consistent receive problemcompared to the st<strong>and</strong>by unit.Also a manual switchover to the st<strong>and</strong>by unit can beinitiated.The units can be controlled from the front panel orremotely via RS 232, RS422/485 or Ethernet. Twopower supplies <strong>and</strong> two AC input connectorsguarantee very high availability of the unit.RX InIP ModemAlarmSignalSplitterEthernetEthernetSwitchIP ModemInternalRS485AlarmControlLogicSignalSwitchTX OutTX Test OutRS232 / RS485 / Ethernet Remote ControlSummary Alarm2012-09-17 59


Redundancy Switch 1:1 for IP ModemsRSCI1ModelItemRSCI1-0-xx - no internal signal splitter or switch is includedRSCI1-50K-xxorRSCI1-50KInternal Signal Transfer SwitchConnector type:4 x SMA femaleImpedance: 50Power h<strong>and</strong>ling:1 W (switching)<strong>Frequency</strong> Range:0 … 18 GHzInsertion loss:60 dB (12 … 18 GHz)Return loss:>26 dB (0 … 1 GHz)>21 dB (1 … 4 GHz)>16 dB (4 … 8 GHz)>15 dB (8 … 12 GHz)>14 dB (12 … 18 GHz)RSCI1-xx - no external signal splitter or switch is includedRSCI1-xx-75LDRSCI1-xx-75LRRSCI1-xx-50VRSCI1-xx-75VRSCI1-xx-50KTExternal Signal Splitter(including diodes for DC)External Signal Splitter(including DC relay switch)External Signal SplitterExternal Signal SplitterExternal Signal Transfer SwitchConnector type:3 x F femaleImpedance: 75Power h<strong>and</strong>ling:100 mW<strong>Frequency</strong> Range:500 … 2400 MHzInsertion loss:5.0 ... 6.2 dBReturn Loss:>20 dBDC Path: max 30 V, 1 A,diode decouplingConnector type:3 x F femaleImpedance: 75Power h<strong>and</strong>ling:100 mW<strong>Frequency</strong> Range:500 … 2400 MHzInsertion loss:5.0 ... 6.2 dBReturn Loss:>20 dBDC Path:max 30 V, 500 mAForm C (SPDT) relayConnector type:3 x BNC femaleImpedance: 50Power h<strong>and</strong>ling:1 W<strong>Frequency</strong> Range:5 … 300 MHzInsertion loss:3.0 … 4.0 dBReturn Loss:>15 dBAmplitude balance:0.4 dBConnector type:3 x BNC femaleImpedance: 75Power h<strong>and</strong>ling:1 W<strong>Frequency</strong> Range:5 … 300 MHzInsertion loss:3.0 … 4.0 dBReturn loss:>15 dBAmplitude balance:0.4 dBConnector type:4 x SMA femaleImpedance: 50Power h<strong>and</strong>ling:1 W (switching)<strong>Frequency</strong> Range:0 … 18 GHzInsertion loss:60 dB (12 … 18 GHz)Return loss:>26 dB (0 … 1 GHz)>21 dB (1 … 4 GHz)>16 dB (4 … 8 GHz)>15 dB (8 … 12 GHz)>14 dB (12 … 18 GHz)Specifications continued next page602012-09-17


Redundancy Switch 1:1 for IP ModemsRSCI1Specifications continued:Ethernet Hardware SwitchSwitching:Remote M&C Interface:Summary Alarm Interface:Internal M&C Interface:Configuration:Temperature Range:Relative Humidity:User Interface:Mains Power Input:Mains Power Consumption:Mains Power Input Connector:Connector:Type:MAC Address announcingscheme, initiated by IP trafficports of IP devices afterswitchover:Manual or AutomaticProtocol:Connection:Protocol:Connection:Protocol:Connection:3 x RJ4510/100/1000 MbpsIPv4: according to extension of RFC 826, Gratuitous ARPIPv6: according to RFC 4861, clause 7.2.6, Unsolicited Neighbor AdvertisementSNMPUDP over Ethernet (10/100 Mbps, auto sensing), IPv4, connector RJ-45HTTP (web browser interface)TCP/IP over Ethernet (10/100 Mbps, auto sensing), IPv4, connector RJ-45MultipointRS232 or RS422/RS485 (configurable), connector DSUB09 female orTCP/IP over Ethernet (10/100 Mbps, auto sensing), IPv4, connector RJ-45Two potential free contacts (DPDT, Connector DSUB09 female)RS485 (Connector DSUB09 male)16 DIP switches on rear side / serial interface-30°C … 60°C operating-30°C … 80°C storage


Compact Redundancy Switch 2:1RSCC-2The WORK Microwave Redundancy Switch RSCC-2is compact solution for a 2:1 Redundancy System. Itcan be used for upconverters, downconverters,modulators <strong>and</strong> modulator-upconverters. The 4coaxial transfer switches are integrated into thehousing.The system can be configured from the front panel orremotely via RS232, RS422/485 or TCP/IP overEthernet.The switching system can be set in automatic mode,were an automatic switchover to the spare unit isperformed upon detection of an alarm of the main unit.Also a manual switchover to the spare unit <strong>and</strong> backcan be initiated.Two power supplies <strong>and</strong> two AC input connectorswithin the unit guarantee very high availability.Input TransferRelaysOutput TransferRelaysIN 1Converter/ModulatorOUT 1IN TestMain 1OUT TestIN 2Converter/ModulatorOUT 2Main 2Converter/ModulatorSpareInternal RS 485Alarm InputsRedundancy Switch with Display <strong>and</strong> KeypadExternal RS485 / RS232 /EthernetMonitor <strong>and</strong> ControlAlarm OutputAC Inputs2:1 RedundancySwitch Systemwith RSCC-2622012-09-17


Visit us at www.work-microwave.deModular Redundancy Switch N:1RSCMThe WORK Microwave Redundancy Switch SystemN:1 can be configured for redundancy configurationswith maximum 8 main units <strong>and</strong> one spare unit. Theredundancy system can be used for upconverters,downconverters, modulators, modulator-upconverters,LNAs <strong>and</strong> even HPAs can optionally be protected.The core of the solution is a highly flexible control unit.The required coaxial transfer switches, waveguidetransfer switches or signal splitters are mounted onseparate panels or within an outdoor housing. At rackmount redundancy systems switching panels can beadded in a modular way to the system if the number ofrequired channels increases over time. Also DCpower to LNAs can be provided, if required.The switching system can be set in automatic mode,were an automatic switchover to the spare unit isperformed upon detection of an alarm of the main unit.Also a manual switchover to the spare unit <strong>and</strong> backcan be initiated.Two power supplies <strong>and</strong> two AC input connectorswithin the controller unit guarantee very highavailability.The Redundancy Switch System is also available withintegrated Uplink Power Control (Option UPC). Forfunctional details see separate datasheet for UplinkPower Control Unit.The system can be configured from the front panel ofthe controller or remotely via RS232, RS422/485 orTCP/IP over Ethernet.IN 1Input TransferRelaysConverter/ModulatorOutput TransferRelaysOUT 1Main 1IN TestOUT TestIN 2Converter/ModulatorOUT 2Main 2Converter/ModulatorSpareMonitor <strong>and</strong> ControlRS232 or RS485 orEthernetControl of Switches / RS485 M&C / Alarm InputsRedundancy Controller with Display <strong>and</strong> KeypadExternal RS485 / RS232EthernetAlarm OutputAC Inputs2:1 ModularRedundancySwitch SystemRSCM-22012-09-17 63


Outdoor Redundancy Switch Unit 2:1The Picture shows an outdoor switching unit of a 2:1redundant switching system. The switching unit isconnected to the control unit, which is installed indoor.Within the outdoor switch unit alarm <strong>and</strong> statusindication via LEDs, manual switchover <strong>and</strong> easyaccess to the serial control interfaces of the converterunits e.g. is possible. The picture below shows atypical 2:1 configuration with upconverters, built asoutdoor solution.IF TransferRelaysAC InputsRF TransferRelaysIF Input 1RF to HPA 1UpconverterMain 1Term.Term.IF Input 2UpconverterRF to HPA 2Main 2UpconverterSpareOutdoorSwitch BoxMonitor <strong>and</strong> ControlRS 232 or RS 485 orEthernetControl ofRS 485 Alarm InputsSwitchesRedundancy ControllerExternal RS 485 / RS 232EthernetAlarm OutputAC Inputs2:1 RedundancySwitch System withOutdoor Switch Unit642012-09-17


Redundancy Switch System (N:1)Remote M&C Interface:Maximum number of switchesper each switch panel:Signal Transfer Switches(Input <strong>and</strong>/or Output)RSCC-2-xx-50KRSCM-n-xx-50KRSCC-2-50K-xxRSCM-n-50K-xxSignal Transfer Switches(Input <strong>and</strong>/or Output)RSCC-2-xx-75LRSCM-n-xx-75LRSCC-2-xx-75LRSCM-n-75L-xxTemperature Range:Relative Humidity:User Interface:Mains Power Input:Mains Power Consumption:Mains Power Input Connector:Mains Fuse:Dimension <strong>and</strong> Weight ofRedundancy Controller:Dimension <strong>and</strong> Weight ofOutdoor Redundancy SwitchUnit 2:1:Protocol:Connection:Protocol:Connection:Protocol:Connection:4 (Indoor switch panel)SNMPUDP over Ethernet (10 or 100 Mbps, auto sensing), connector RJ-45HTTP (web browser interface)TCP/IP over Ethernet (10 or 100 Mbps, auto sensing), connector RJ-45MultipointRS232 or RS422/RS485 (configurable), connector DSUB09 female orTCP/IP over Ethernet (10 or 100 Mbps, auto sensing), connector RJ-45Connector type:4 x SMA female (Indoor switch panel)(N female on IF interfaces, SMA female on RF interfaces of outdoor switch unit)Impedance: 50Power h<strong>and</strong>ling:1 W (switching)<strong>Frequency</strong> Range:Insertion Loss:Isolation:0 … 18 GHz60 dB (12 … 18 GHz)Return Loss:>26 dB (0 … 1 GHz)>21 dB (1 … 4 GHz)>16 dB (4 … 8 GHz)>15 dB (8 … 12 GHz)>14 dB (12 … 18 GHz)(waveguide switches <strong>and</strong> other transfer switches on request)Connector type:4 x 1.6/5.6 female (Indoor switch panel)(Adapters to external BNC female connectors are provided)Impedance: 75Power h<strong>and</strong>ling:1 W (switching)<strong>Frequency</strong> Range:0 … 2.5 GHzInsertion Loss:70 dB (1 … 2.5 GHz)Return Loss:>20 dB (0 … 1 GHz)>18 dB (1 … 2.5 GHz)-30°C … 60°C operating-25°C … 60°C operating (for RSCM-n-L75T..)(the LCD display is operational: -20°C … 60°C)-30°C … 80°C storage


Order Information:Compact Redundancy Switch:RSCC-2-[Input Switch Type]-[Output Switch Type]-[Options]Modular Redundancy System:RSCM-[Number of signal channels]-[Input Switch Type]-[Output Switch Type]-[Options]Possible Options are:OD (with outdoor switch unit, available only for two channels on RSCM)UPC (Uplink Power control included, available for RSCM)AO (Internal Alarm only connection, without RS485 communication)BC (for Block <strong>Converters</strong> only)Examples:RSCC-2-50K-50KRSCM-2-50K-50KRSCM-2-50K-50K-ODRSCM-8-50K-50K662012-09-17


Visit us at www.work-microwave.deOutdoor HousingsWORK Microwave provides its proven satellitecommunication equipment also in different outdoorhousings, which can be used under all weatherconditions. The units can be operated over atemperature range -30°C to 60°C (-22°F to140°F). Inthe non-operating modus they survive temperatures of-50°C to 80°C (-58°F to 176°F) without any damage.Same as the 19'' rack mount units, they meet therequirements for modern satellite transmissionapplications, such as for TV up-link <strong>and</strong> high-speeddata network installations. Because of their ruggedconstruction <strong>and</strong> low power consumption, they aremost suitable for fixed satellite earth stations, satellitenews gathering (SNG) vehicles or Fly-Aways.Dimensions of small Outdoor HousingWORK Mixcrowave outdoor units are best fit to bemounted directly to the antenna. They do not requireadditional protection against water. The housingprovides environmental protection according to IP67(temporary flooding) when all cables are connected<strong>and</strong> sealed appropriately. Special environmentalprotection sleeves for the coaxial connectors allowoptimal sealing from the housing to the cable.Additionally the housing should be mounted with theconnector side down. Alternatively the connectorpanel can be in a vertical position.Dimensions of large Outdoor HousingMonitoring <strong>and</strong> Control Interface:Temperature Range:RS232 or RS422/RS485Alarm output: Two potential free contacts (DPDT)24 V DC output: max 0,3 A6,5 V DC output: max 0,2 AMute Input: TTL logic input with internal pull up(Connector type: MIL-C-26482: MS 3120 E 14-19 S)-30°C … 60°C operating (10 minutes warmup at -30 °C)Relative Humidity:


Raiffeisenstraße 1283607 HolzkirchenGermanyTel. +49 8024 6408 0Fax +49 8024 6408 40sales@work-microwave.dewww.work-microwave.de

Hooray! Your file is uploaded and ready to be published.