<strong>catalogue</strong> <strong>2009</strong>producer of emergency lighting


contentsLiderLider autotestEmergency modecentral lock systemRubic monitoring systemTigerTiger pTiger dsTiger ledTiger p ledTiger ds ledHeliosHelios pHelios dsHelios ledHelios p ledHelios ds ledViper rViper sEmxClassicClassic silverClassic fwDubloEscapeTwinsPlexi ledPanoramaSquareTwisterQuadroHermeticaUfoAccessoriesPictogramsList of terms234681012141516182022242526283032343638404244464850525456586061621


liderconversion kitTechnical profile:Power of fluorescent lamp: 6 - 80WEmergency operation time: 1, 2 or 3 hoursType of fluorescent lamp: T8, T5, compactlampsBallast: KVG, EVGTechnical specifications concerningthe emergency lighting:Regular power supply: 220-240V/50-60HzFluorescent lamp power range 6-80W(depends on a model)Ambient temperature (ta): 0.. + 55°C.Operation temperature (te): 0.. + 70°CBatteries used: high temperature,non-maintained NiCd HT batteryBattery package voltage: 3.6V; 4.8V; 6V andthe capacity 1,0 - 4Ah (depends on the model)Rated current of battery discharge 0,1CMaximum current of battery discharge:


lider autotestconversion kitTechnical profile:Power of fluorescent lamp: 6 - 80WEmergency operation time: 1, 2 or 3 hoursType of fluorescent lamp: T8, T5, compactlampsBallast: KVG, EVGTechnical specifications concerningthe emergency lighting:Regular power supply: 220-240V/50-60HzFluorescent lamp power range 6-80W(depends on a model)Ambient temperature (ta): 0.. + 55°C.Operation temperature (te): 0.. + 70°CBatteries used: high temperature,non-maintained NiCd HT batteryBattery package voltage: 3.6V; 4.8V; 6V andthe capacity 1,0 - 4Ah (depends on the model)Rated current of battery discharge 0,1CMaximum current of battery discharge:


RUBIC Monitoring SystemDescription of the RUBIC system:In buildings where there is a need for installing a large number of independent emergency lightingfittings, there is always a problem connected to the process of controlling the condition of the fittings.Manual controlling of the condition of the fittings requires a lot of time and may sometimes disturb theregular use of the premises. RUBIC system, designed to monitor the operation of emergency fittings withindependent power sources, was created to solve this problem. Modern solutions of the Rubic systemallow for the configuration and control of the condition of the fittings from one place.Components of the system:C-Rubic control unit, LIDER RS addressing emergency module, P-Rubic programmer, RPT signalamplifier.C-RUBIC control unitP -RUBIC programmerLider RS addressing emergency moduleC-RUBICcontrol unitStandard monitoring of 250 fittingsExpansion within the standard unit up to1000 fittingsExpansion of the system with one control unitup to 10 000 fittingsControl and communication with otherC-RUBIC control unitsCentronix printer connector3 LED diodes signalling the condition of thesystemLCD monitor230V 50Hz power supplyCharge time - 24hCommunication through a screened cable2 x 0,5 mm2Distance between the control unit and thefurthest fitting - 1200 m 2Possibility of extending the communicationcable’s distance by another 1200 m 2using the RPT signal amplifierPower supply through 3 x 1,5 mm 2 cableP-RUBICprogrammerLider RS addressingemergency moduleUnique addressFluorescent lamp power 6W - 80WEmergency operation time 1, 2 or 3 hoursFluorescent lamp type T8, T5 andcompact 4 pinCompatibility with KVG and EVG ballastsGreen diode - signals correct battery chargeRed diode - signals abnormal functioningof the fittingcodepoweroperationtimebatteryLERS/36/1 6W-36W 1 h Ni-Cd 3,6V 2,5AhLERS/36/2 6W-36W 2 h Ni-Cd 3,6V 2,5AhLERS/36/3 6W-36W 3 h Ni-Cd 3,6V 4,0AhLERS/58/1 6W-58W 1 h Ni-Cd 4,8V 2,5AhLERS/58/2 6W-58W 2 h Ni-Cd 4,8V 2,5AhLERS/58/3 6W-58W 3 h Ni-Cd 4,8V 4,0AhLERS/80/1 6W-80W 1 h Ni-Cd 6,0V 2,5AhLERS/80/2 6W-80W 2 h Ni-Cd 6,0V 2,5AhLERS/80/3 6W-80W 3 h Ni-Cd 6,0V 4,0ASerial programming of LIDER RS modulesIndividual programming of LIDER RS modulesProgramming without the necessity of powersupply to the LIDER RS moduleIndependent power supply6


Functions of the system:Constant communication between the centralunit and the lighting fittingsRunning auto testsRunning manual testsRegistering test results (memory of central unit- minimum 1 year)Printing test results using PR-RUBIC printeror an external printerEmergency mode lockDividing the monitored fittings into groupsReporting any abnormalitiesConnecting with a PC through an interfacean interface and creating visual presentationswith the help of a special softwareControl of the system from any place throughinternet linksTest calendar configured to suit individualneedsLighting fittings working under the RUBIC systemhave unique addresses and are connected toC-Rubic control unit with a communication cable.The fittings communicate with the central unitreporting any abnormalities which are signaledon the central unit display with LED diodes placedon the central unit panel. Each fitting connectedto the system may have an individual descriptionin the control unit. When abnormalities occurconnected to the operation of a fitting, informationabout the type of abnormality and the location ofthe fitting appears on the display of the controlunit. The system allows for manual testing ofa single fitting. C-Rubic central unit’s softwareallows to divide the fittings into groups whichenables one to run tests only on chosen groupsof fittings. Apart from manual tests, the followingauto-tests are carried out:Test A - a short test, recommended every30 days (PN-EN 50172) - checks the followingparameters:enforcing emergency operation of the fitting for5 minutescontrol of battery power dischargecontrol of minimum voltage of batteryTest B - a long test recommended every360 days (PN-EN 50172) - checks the followingparameters:enforcing emergency operation of the fitting forthe time programmed for each fitting (1, 2, 3 h)control of battery power dischargecontrol of minimum voltage of batterycontrol of the condition of batteryThe frequency of running tests A and B may beprogrammed according to the needs of the user.There is a possibility of programming the tests withexact dates of when they should be carried out.Long tests B should be run when the premises arenot to be used within 24 hours after finishing thetest. This time is needed for the recharging of thebatteries discharged during the long test.Test results are stored in the memory of thecentral unit and may be viewed on the centralunit’s display. Test reports may be printed with anyprinter using LPT connector (Centronix).printer C-RubicPC internet7


tigeruniversal, one-sided emergency fittingMaterials:white polycarbonate bodytransparent polycarbonate coverMounting:wall or ceiling or optional dry-wall or under plasteringSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesFluorescent lamp T5 8WInsulation class IIProtection level IP22Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 20 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionTG 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workTG 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingNETWORKConfiguration of fittingtypecentral bat.typenetworkTGCBTGSLIGHT SOURCECharacteristicpower [W]cap8 G5Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgTG - tiger fitting9


tiger puniversal, two-sided emergencylighting fittingMaterials:white polycarbonate bodytransparent polycarbonate cover, plexi glassMounting:ceiling or optional dry-wall or under plasteringSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesFluorescent lamp T5 8WInsulation class IIProtection level IP22Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionTP 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workTP 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingNETWORKConfiguration of fittingtypecentral bat.typenetworkTPCBTPSLIGHT SOURCECharacteristicpower [W]cap8 G510Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgTP - tiger p fitting


tiger dsuniversal, two-sided emergencylighting fittingMaterials:white polycarbonate bodyopal polycarbonate coverMounting:ceiling or optional dry-wall or under plasteringSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesFluorescent lamp T5 8WInsulation class IIProtection level IP22Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 20 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionTGS 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workTGS 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingNETWORKConfiguration of fittingtypecentral bat.typenetworkTGSCBTGSSLIGHT SOURCECharacteristicpower [W]cup8 G5Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgTGS - tiger ds fitting13


tiger leduniversal, one-sided emergencylighting fittingMaterials:white polycarbonate bodyopal polycarbonate coverMounting:wall or ceiling or optional dry-wall or underplasteringSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery chargeLED indicatorHigh-temperature nickel-cadmium batteriesLed 25 cd diodesInsulation class IIProtection level IP22Ambient temperature: 0°C to +40°CElectronic protection against complete batterydischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 20 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specificationsEN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionTL 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workTL 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingtypeTLcentral bat.CBNETWORKConfiguration of fittingtypeTLnetworkS14Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgTL - tiger led fitting


tiger p leduniversal, two-sided emergencylighting fittingMaterials:white polycarbonate bodytransparent polycarbonate cover, plexi glassMounting:ceiling or optional dry-wall or under plasteringSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LEDindicatorHigh-temperature nickel-cadmium batteriesLed 25 cd diodesInsulation class IIProtection level IP22Ambient temperature: 0°C to +40°CElectronic protection against complete batterydischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionTPL 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workTPL 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingtypeTPLcentral bat.CBNETWORKConfiguration of fittingtypeTPLnetworkSLegend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgTPL - tiger p led fitting15


tiger ds leduniversal, two-sided emergencylighting fittingMaterials:white polycarbonate bodyopal polycarbonate coverMounting:ceiling or optional dry-wall or under plasteringSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesLed 25 cd diodesInsulation class IIProtection level IP22Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 20 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionTSL 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workTSL 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingNETWORKConfiguration of fittingtypecentral bat.typenetworkTSLCBTSLS16Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgTSL - tiger ds led fitting


heliosuniversal, one-sided emergencylighting fittingMaterials:white polycarbonate bodytransparent or opal polycarbonate coverMounting:wall or ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery chargeLED indicatorHigh-temperature nickel-cadmium batteriesFluorescent lamp 8W or compactlamp 11W, 18WInsulation class IIProtection level IP42, IP65Ambient temperature: 0°C to +40°CElectronic protection against complete batterydischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 25 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN60598, EN 1838Optional PT or RSSTANDARD HE - IP42Configuration of fittingLIGHT SOURCECharacteristicHelios 8Wtype time [h] work option power [W]power [W]cupHE 1 2 3 SE SA PT RS 8 11 18STANDARD H - IP65Configuration of fitting8 G511 2G718 2G11type time [h] work option power [W]H 1 2 3 SE SA PT RS 8 11 18AUTOTEST - HE IP42Configuration of fittingHelios 11WHelios 18Wtype time [h] autotest work power [W]HE 1 2 3 AT SE SA 8 11 18AUTOTEST - H IP65Configuration of fittingtype time [h] autotest work power [W]H 1 2 3 AT SE SA 8 11 18FOR CENTRAL BAT.Configuration of fittingtype central bat. IP power [W]HE CB 42 8 11 18H CB 65 8 11 18NETWORKConfiguration of fittingtype network IP power [W]HE S 42 8 11 18H S 65 8 11 18Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgHE - helios IP 42 fittingH - helios IP 65 fitting19


helios puniversal, two-sided emergencylighting fittingMaterials:white polycarbonate bodytransparent polycarbonate cover, plexi glassMounting:ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesFluorescent lamp T5 8WInsulation class IIProtection level IP42Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionHP 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workHP 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingNETWORKConfiguration of fittingtypecentral bat.typenetworkHPCBHPSLIGHT SOURCECharacteristicpower [W]cup8 G520Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgHP - helios p fitting


helios dsuniversal, two-sided emergencylighting fittingMaterials:white polycarbonate bodyopal polycarbonate coverMounting:ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesFluorescent lamp 8W or compact lamp 11W, 18WInsulation class IIProtection level IP42, IP65Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 25 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARD HDE - IP42Configuration of fittingtype time [h] work option power [W]HDE 1 2 3 SE SA PT RS 8 11 18STANDARD HD - IP65Configuration of fittingtype time [h] work option power [W]NETWORKConfiguration of fittingtype network IP power [W]HDE S 42 8 11 18HD S 65 8 11 18LIGHT SOURCECharacteristicHD 1 2 3 SE SA PT RS 8 11 18power [W]cupAUTOTEST - HDE IP42Configuration of fittingtype time [h] autotest work power [W]8 G511 2G718 2G11HDE 1 2 3 AT SE SA 8 11 18AUTOTEST - HD IP65Configuration of fittingtype time [h] autotest work power [W]HD 1 2 3 AT SE SA 8 11 18FOR CENTRAL BAT.Configuration of fittingtype central bat. IP power [W]HDE CB 42 8 11 18HD CB 65 8 11 18Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgHDE - helios ds IP 42 fittingHD - helios ds IP 65 fitting23


helios leduniversal, one-sided emergencylighting fittingMaterials:white polycarbonate bodyopal polycarbonate coverMounting:wall or ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery chargeLED indicatorHigh-temperature nickel-cadmium batteriesLED 25 cd diodesInsulation class IIProtection level IP42, IP65Ambient temperature: 0°C to +40°CElectronic protection against complete batterydischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 25 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specificationsEN 60598,EN 1838Optional PT or RSAUTOTEST - HEL IP42Configuration of fittingtype time [h] autotest workHEL 1 2 3 AT SE SAAUTOTEST - HL IP65Configuration of fittingtype time [h] autotest workHL 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingtype central bat. IPHEL CB 42HL CB 65NETWORKConfiguration of fittingtype network IPHEL S 42HL S 65STANDARD HEL - IP42Configuration of fittingtype time [h] work optionHEL 1 2 3 SE SA PT RSSTANDARD HL - IP65Configuration of fitting24type time [h] work optionHL 1 2 3 SE SA PT RSLegend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgHEL - helios led IP42 fittingHL - helios led IP65 fitting


helios p leduniversal, two-sided emergencylighting fittingMaterials:white polycarbonate bodytransparent polycarbonate cover, plexi glassMounting:ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LEDindicatorHigh-temperature nickel-cadmium batteriesLED 25 cd diodesInsulation class IIProtection level IP42Ambient temperature: 0°C to +40°CElectronic protection against complete batterydischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionHPL 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workHPL 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingtypeHPLcentral bat.CBNETWORKConfiguration of fittingtypeHPLnetworkSLegend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgHPL - helios p led fitting25


helios ds leduniversal, two-sided emergencylighting fittingMaterials:white polycarbonate bodyopal polycarbonate coverMounting:ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesLED 25 cd diodesInsulation class IIProtection level IP42, IP65Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 25 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARD HDEL - IP42Configuration of fittingtype time [h] work optionHDEL 1 2 3 SE SA PT RSSTANDARD HDL - IP65Configuration of fittingNETWORKConfiguration of fittingtype network IPHDEL S 42HDL S 65type time [h] work optionHDL 1 2 3 SE SA PT RSAUTOTEST - HDEL IP42Configuration of fittingtype time [h] autotest workHDEL 1 2 3 AT SE SAAUTOTEST - HDL IP65Configuration of fittingtype time [h] autotest workHDL 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingtype central bat. IP26HDEL CB 42HDL CB 65Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgHDEL - helios ds led IP 42 fittingHDL - helios ds led IP 65 fitting


viper runiversal, one-sided emergencylighting fittingMaterials:steel sheet base painted white or silverMounting:wall or ceiling or optional dry-wall or under plasteringSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteries3 power led 1WInsulation class IProtection level IP20Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 25 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionVR 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workVR 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingtypeVRcentral bat.CBNETWORKConfiguration of fittingtypeVRnetworkSLegend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemATSCBVR- autotest- network- for central battery evg- viper r fitting29


viper suniversal, one-sided emergencylighting fittingMaterials:steel sheet base painted white or silverMounting:wall or ceiling or optional dry-wall or under plasteringSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteries3 power led 1WInsulation class IProtection level IP20Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 25 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionVS 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workVS 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingtypeVScentral bat.CBNETWORKConfiguration of fittingtypeVSnetworkS30Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemATSCBVS- autotest- network- for central battery evg- viper s fitting


emxuniversal, one-sided emergencylighting fittingMaterials:white polycarbonate bodytransparent polycarbonate coverMounting:wall or ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesFluorescent lamp 2 x 8W or compact lamp 18W, 24W, 36WInsulation class IProtection level IP65Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 25 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work option power [W]EM 1 2 3 SE SA PT RS 2x8 18 24 36AUTOTESTConfiguration of fittingtype time [h] autotest work power [W]EM 1 2 3 AT SE SA 2x8 18 24 36FOR CENTRAL BAT.Configuration of fittingtype central bat. power [W]EM CB 2x8 18 24 36NETWORKConfiguration of fittingtype network power [W]EM S 2x8 18 24 36LIGHT SOURCECharacteristicpower [W] cup2x8 G518 2G11power [W] cup24 2G1136 2G10Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgEM - emx fitting33


classicuniversal, one-sided emergencylighting fittingMaterials:steel sheet base painted whiteMounting:wall and ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesFluorescent lamp T5 8WInsulation class IProtection level IP40Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionC 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workC 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingNETWORKConfiguration of fittingtypecentral bat.typenetworkCCBCSLIGHT SOURCECharacteristicpower [W]cup8 G534Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgC - classic fitting


classic silveruniversal, one-sided emergency lightingfittingMaterials:steel sheet base painted silverMounting:wall or ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesFluorescent lamp T5 8WInsulation class IProtection level IP40Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionCS 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workCS 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingNETWORKConfiguration of fittingtypecentral bat.typenetworkCSCBCSSLIGHT SOURCECharacteristicpower [W]cup8 G5Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgCS - classic silver fitting37


classic fwuniversal, one-sided emergencylighting fittingMaterials:steel sheet base painted silver or whiteMounting:dry-wallSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesFluorescent lamp T5 8WInsulation class IProtection level IP40Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionCW 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workCW 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingNETWORKConfiguration of fittingtypecentral bat.typenetworkCWCBCWSLIGHT SOURCECharacteristicpower [W]cup8 G538Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgCW - classic fw fitting


dublouniversal, two-sided emergencylighting fittingMaterials:steel sheet base painted whiteMounting:wall or ceiling, optional mounting on a rope slingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesFluorescent lamp T5 8WInsulation class IProtection level IP40Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARD DUBLO SConfiguration of fittingFOR CENTRAL BAT.Configuration of fittingNETWORKConfiguration of fittingtype time [h] work optiontypecentral bat.typenetworkDS 1 2 3 SE SA PT RSDSCBDSSSTANDARD DUBLO DConfiguration of fittingtype time [h] work optionDDCBLIGHT SOURCECharacteristicDDSDD 1 2 3 SE SA PT RSpower [W]cupAUTOTEST DUBLO SConfiguration of fitting8 G5type time [h] autotest workDS 1 2 3 AT SE SAAUTOTEST DUBLO DConfiguration of fittingtype time [h] autotest workDD 1 2 3 AT SE SALegend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgDS - dublo s fittingDD - dublo d fitting41


escapeuniversal, two-sided emergencylighting fittingMaterials:steel sheet base painted white, plexi glassMounting:ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesFluorescent lamp T5 8WInsulation class IProtection level IP20Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionE 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workE 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingNETWORKConfiguration of fittingtypecentral bat.typenetworkECBESLIGHT SOURCECharacteristicpower [W]cup8 G542Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgE - escape fitting


twinsuniversal, two-sided emergencylighting fittingMaterials:natural or black aluminium body, plexi glassMounting:wall, ceiling or rope slingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesLED 25 cd diodes or fluorescent lamp 8WInsulation class IProtection level IP20Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2, 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionTW 1 2 3 SE SA PT RSTWB 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] work autotestTW 1 2 3 SE SA ATTWB 1 2 3 SE SA ATFOR CENTRAL BAT.Configuration of fittingNETWORKConfiguration of fittingtypecentr. bat.typenetworkTWCBTWSTWBCBTWBSLegend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery EVGTW - twins fittingTWB - twins black fitting45


plexi leduniversal, two-sided emergencylighting fittingMaterials:steel sheet base painted silver or white, plexi glassMounting:dry-wall ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesLED 25 cd diodes or fluorescent lamp 8WInsulation class IProtection level IP20Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2, 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionPL 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workPL 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingNETWORKConfiguration of fittingtypecentral bat.typenetworkPLCBPLS46Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgPL - plexi led fitting


panoramauniversal, one-sided emergencylighting fittingMaterials:white plastic bodywhite polycarbonate coverMounting:wall or ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesFluorescent lamp T5 8W or compact fluorescent lamp 2G7-11WInsulation class IProtection level IP54Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work option power [W]P 1 2 3 SE SA PT RS 8 11AUTOTESTConfiguration of fittingtype time [h] autotest work power [W]P 1 2 3 AT SE SA 8 11FOR CENTRAL BAT.Configuration of fittingNETWORKConfiguration of fittingtypecentral bat.typenetworkPCBPSLIGHT SOURCECharacteristicpowercup8 G511 2G7Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgP - panorama fitting49


squareuniversal, one-sided emergencylighting fittingMaterials:white plastic bodywhite polycarbonate coverMounting:wall or ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesCompact fluorescent lamp 7W, 9W, 11W, 18WInsulation class IProtection level IP54, IP65Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursConnecting clips 3 x 2,5 mm 2Optional PT or RSSTANDARD SMConfiguration of fittingLIGHT SOURCECharacteristictype time [h] work option power [W]power [W]cuppower [W]cupSM 1 2 3 SE SA PT RS 7 97 2G711 2G7STANDARD SDConfiguration of fitting9 2G718 2G11type time [h] work option power [W]SD 1 2 3 SE SA PT RS 11 18 2x11 2x18AUTOTEST SMConfiguration of fittingtype time [h] autotest work power [W] optionSM 1 2 3 AT SE SA 9 PT RSAUTOTEST SDConfiguration of fittingtype time [h] a.test work power [W] optionSD 1 2 3 AT SE SA 11 18 2x11 2x18 PT RSFOR CENTRAL BAT.Configuration of fittingtype central bat. power [W]SD CB 9 11 18 2x11 2x18NETWORKConfiguration of fitting50type central bat. power [W]SD S 9 11 18 2x11 2x18Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgSM - square m fittingSD - square d fitting


twisteruniversal, one-sided emergencylighting fittingMaterials:white plastic bodywhite polycarbonate coverMounting:wall or ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesCompact fluorescent lamp 7W, 9W, 11W, 18WInsulation class IProtection level IP54, IP65Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursConnecting clips 3 x 2,5 mm 2Optional PT or RSSTANDARD TMConfiguration of fittingLIGHT SOURCECharacteristictype time [h] work option power [W]power [W]cuppower [W]cupTM 1 2 3 SE SA PT RS 7 97 2G711 2G7STANDARD TDConfiguration of fitting9 2G718 2G11type time [h] work option power [W]TD 1 2 3 SE SA PT RS 11 18 2x11 2x18AUTOTEST TMConfiguration of fittingtype time [h] autotest work power [W] optionTM 1 2 3 AT SE SA 9 PT RSAUTOTEST TDConfiguration of fittingtype time [h] a.test work power [W] optionTD 1 2 3 AT SE SA 11 18 2x11 2x18 PT RSFOR CENTRAL BAT.Configuration of fittingtype central bat. power [W]TD CB 9 11 18 2x11 2x18NETWORKConfiguration of fittingtype central bat. power [W]TD S 9 11 18 2x11 2x18Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgTM - twister m fittingTD - twister d fitting53


quadrouniversal, four-sided emergencylighting fittingMaterials:white polycarbonate bodyMounting:wall or ceiling, possibility of mountingon a cord slingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesCompact fluorescent lamp 11WInsulation class IProtection level IP41Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursRecognition distance 30 mConnecting clips 3 x 2,5 mm 2Compatibility with standard specifications EN 60598, EN 1838Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work optionQ 1 2 3 SE SA PT RSAUTOTESTConfiguration of fittingtype time [h] autotest workQ 1 2 3 AT SE SAFOR CENTRAL BAT.Configuration of fittingNETWORKConfiguration of fittingtypecentral bat.typenetworkQCBQSLIGHT SOURCECharacteristicpower [W]cup11 2G754Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgQ - quadro fitting


hermeticauniversal, one-sided emergencylighting fittingMaterials:grey polycarbonate body,transparent polycarbonate coverMounting:wall or ceilingSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery charge LED indicatorHigh-temperature nickel-cadmium batteriesFluorescent lamp T8 18W, 36W, 58WInsulation class IProtection level IP65Ambient temperature: 0°C to +40°CElectronic protection against complete battery dischargeEmergency operation time 1, 2 or 3 hoursConnecting clips 3 x 2,5 mm 2Optional PT or RSSTANDARDConfiguration of fittingtype time [h] work option power [W]HR 1 2 3 SE SA PT RS 18 2x18 36 2x36 58 2x58NETWORKConfiguration of fittingtype network power [W]HR S 18 2x18 36 2x36 58 2x58AUTOTESTConfiguration of fittingLIGHT SOURCECharacteristictype time [h] a.test work power [W]power [W]cupHR 1 2 3 AT SE SA 18 2x18 36 2x36 58 2x58FOR CENTRAL BAT.Configuration of fitting18 G1336 G1358 G13type central bat. power [W]HR CB 18 2x18 36 2x36 58 2x5856Legend:SE - non-maintainedSA - maintainedPT - manual test buttonRS - rubic monitoring systemAT - autotestS - networkCB - for central battery evgHR - hermetica fitting


ufoemergency lighting fittingMaterials:steel sheet base painted greyMounting:wallSpecification:230V 50Hz power supplyCharge time - 24 hoursElectric power network and battery chargeLED indicatorGel accumulatorsHalogen bulbs 21W, 55WInsolation class IProtection level IP20Ambient temperature: 0°C to +40°CElectronic protection against complete batterydischargeEmergency operation time 1, 2 or 3 hoursConnecting clips 3 x 2,5 mm 2STANDARDConfiguration of fittingtype time [h] work power [W]U 1 3 SE 2x21 55 2x55Legend:SE - non-maintainedU - ufo fitting57


accessoriesWire guards for heliosand emxBatteriesBattery PackagesDimensions [mm]AxBxCcDxExFWeight[kg]NiCd SC 1500mAh 3,6VNiCd SC 1500mAh 4,8VNiCd SC 1500mAh 6V135x160x26x22x18x4176x203x26x22x18x4220x245x26x22x18x40,1580,2050,260NiCd C 2500mAh 3,6VNiCd C 2500mAh 4,8VNiCd C 2500mAh 6V153x175x30x26x20x4200x227x30x26x20x4253x279x30x26x20x40,2200,2870,357NiCd D 4000mAh 3,6VNiCd D 4000mAh 4,8VNiCd D 4000mAh 6V190x217x36x33x25x4245x272x36x33x25x4306x330x36x33x25x40,4050,5400,670Mountig accessoriesWire rope suspensionaccessoriesCeiling mountingbracketWall mountingbracketPendant ceilingbracketUnder plastering clipsfor Tiger58


pictograms01 02 0304 05 0607 08 0910 11 1213 14 15small medium bigdimension [mm] 100 x 300 125 x 250 150 x 300designed forTG, TL, TGS, TSLH, HE, HL, HEL, HD, HDE,HDL, HDEL, VR, VSTP, TPL, HP, HPL, E, TW,PL, P, C,CS59


list of termsSE - NON-MAINTAINEDThe fitting is off when regular power is on. Thefitting turns on after the power cut and stays onduring the emergency operation time 1, 2 or 3hours.SA - MAINTAINEDThe fitting is on when regular power is on. After thepower is cut, it switches to the emergency modeand stays on during the emergency operationtime 1, 2 or 3 hours.PT - MANUAL TEST BUTTONThe fitting is equipped with a test button whichallows one to run a test of emergency modewithout switching off the regular power.RS - RUBIC MONITORING SYSTEMThe fitting is equipped with an addressing modulewith a unique address compatibile with the RUBICmonitoring system.AT - AUTOTESTThe fitting is equipped with an autonomous testingsystem.S - NETWORKThe fitting operating with regular power 230V50Hz is not equipped with emergency function.CB - FOR CENTRAL BATTERYThe fitting is equipped with an electronic AC/DC ballast compatibile with any central batterysystem.How to configure?Example SQUARE D fitting:type time [h] work power [W]optionSD 1 2 3 SE SA 11 18 2x11 2x18PTRS code: SD/2/SE/2x11/PT60


fittings’ symbolsTGTPTGSTLTPLTSLHEHHPHDEHDHELHLHPLHDELHDLVRVSEMCCSCWDSDDTWPLEPSMSDTMTDQHRUTIGERTIGER PTIGER DSTIGER LEDTIGER P LEDTIGER DS LEDHELIOS IP42HELIOS IP65HELIOS PHELIOS DS IP42HELIOS DS IP65HELIOS LED IP42HELIOS LED P65HELIOS P LEDHELIOS DS LED IP42HELIOS DS LED IP65VIPER RVIPER SEMXCLASSICCLASSIC SILVERCLASSIC FWDUBLODUBLO DTWINSPLEXI LEDESCAPEPANORAMASQUARE MSQUARE DTWISTER MTWISTER DQUADROHERMETICAUFOSzanowni Państwo


producer of emergency lightingP. P. H. U. AWEXMasłomiąca 256, 32-091 Michałowice, POLANDphone: +48 12 388 70 63, fax: +48 12 388 70 64e-mail: export@awex.euwww.awex.eu