12.07.2015 Views

Material Safety Data Sheet

Material Safety Data Sheet

Material Safety Data Sheet

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Material</strong> <strong>Safety</strong> <strong>Data</strong> <strong>Sheet</strong>U.S. Department of LaborMay be used to comply w ithOccupational <strong>Safety</strong> and Health AdministrationOSHA' s Hazard Communication Standard,(Non-Mandatory-Form)29 CFR 1910.1200. Standard must be Form Approvedconsulted for specific requirements. OMB No. 1218-0072IDENTITY (As Used on Label and List)Note: Blank spaces are not permitted. If any item is not applicable, or noinformation is available, the space must be marked t o indicate that.Section IManufacturer' s NameFREEZER FLOOR CLEANERSunburst Chemicals, Inc.Address (Number, Street, City, State, and ZIP Code)220 W. 86th St.Bloomington, MN 55420NA = Not Applicable NIA = No Information AvailableEmergency Telephone Number1-866-303-6943 (7 days/24 hours)Telephone Number For Information(952)884-3144Date Prepared05-26-11Signature of Preparer (optional)Section II - Hazardous Ingredients/Identity InformationOther LimitsHazardous Components (Specific Chemical Identity; Common Name(s)) OSHA PEL ACGIH TLV Recommended %(optional)Ethylene Glycol Cas #107-21-1 NIA 10mg/m3 30%For particulatesIsopropanol CAS#67-63-0 400ppm TWA 400ppm TWA2-butoxyethanol CAS#111-76-2 50 ppm NIA 2%Section III - Physical/Chemical CharacteristicsBoiling PointOver 212°F.Vapor Pressure (mm Hg.)NAVapor Density (AIR= 1)NASpecific Gravity (H 2 0= 1)Melting PointEvaporation Rate(Butyl Acetate = 1)Solubility In WaterMiscible.Appearance and OdorClear, colorless foamy liquid, alcohol odor.Section IV - Fire and Explosion Hazard <strong>Data</strong>Flash Point (Method Used)Flammable Limits LEL UELNone.NAExtinguishing MediaWater, CO 2 , Dry chemical.Special Fire Fighting ProceduresNone.Unusual Fire and Explosion HazardsCombustible, in case of fire plastic jugs may rupture and expose combustibleingredients.HMIS1 HEALTH HEALTH HAZARD FIRE HAZARD Flash Points SPECIFIC HAZARD REACTIVITY2 FLAMMABILITY 4 Deadly 4 Below 73° F (Boiling pt. below 100° F) Oxidizer OX 4 May detonate0 REACTIVITY 3 Extreme danger 3 Below 73° F (Boiling pt. at/above 100° F) Acid ACID 3 Shock and heat may detonateB PERSONAL 2 Hazardous And/or at/above 73° F - not exceeding 100° F X Alkali ALK 2 Violent chemical changePROTECTION X 1 Slightly hazardous X 2 Above 100° F, Not Exceeding 200° F Corrosive COR 1 Unstable if heated0 Normal material 1 Above 200° F Use NO WATER X 0 Stable0 Will not burn RadioactiveNFPA1.01NIANANAPage 1


(CONTINUED) – FREEZER FLOOR CLEANERSection V - Reactivity <strong>Data</strong>Stability Unstable Conditions to AvoidStableXIncompatibility (<strong>Material</strong>s to Avoid)None.Hazardous Decomposition or ByproductsNone.Hazardous May OccurPolymerizationWill Not Occur XConditions to AvoidSection VI – Health Hazard <strong>Data</strong>Routes(s) of Entry: Inhalation? Skin? Ingestion?Not probable Possible Not probableHealth Hazards (Acute and Chronic)ACUTE – not hazardous. CHRONIC – NIA.Carcinogenicity: NTP? IARC Monographs? OSHA Regulated?NIA NIA NIASigns and Symptoms of ExposureMild irritation in contact with concentrated Freezer Floor Cleaner.Medical Conditions Generally Aggravated by ExposureNIA.Emergency and First Aid ProceduresThoroughly rinse or dilute with water. Get medical attention irritation persists.If ingested, drink a large quantity of milk or water. Get immediate medicalattention. Induce vomiting if large amount of concentrated product is consumed.Section VII – Precautions for Safe Handling and UseSteps to Be Taken in Case <strong>Material</strong> is Released or SpilledAbsorb spilled material with an absorbent material such as clay, sawdust, or sand.Sweep up as much of this as possible and place in a sealed, labeled container orin a proper landfill. Thoroughly rinse the affected area with water.Waste Disposal MethodSpilled material should be collected as above for disposal in a landfill according toFederal, State, and Local regulations. Any rinsing of the affected area should also bein accordance with Federal, State and Local regulations.Precautions to Be Taking in Handling and StoringStore between 40-100°F.Other PrecautionsKeep our of reach of children.Section VIII - Control MeasuresRespiratory Protection (Specify Type)Not required.Ventilation Local ExhaustSpecialNANIAMechanical (General)NIAOtherAvoid prolonged exposure in smallconfined areas.Eye Protection<strong>Safety</strong> glasses, goggles recommended.Protective GlovesRubber or vinyl recommended .Other Protective Clothing or EquipmentRubber boots.Work/Hygienic PracticesAvoid contact with concentrated product. Always wash skin and clothing after using allchemical cleaners.Page 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!