12.07.2015 Views

2 - Hayward Flow Control

2 - Hayward Flow Control

2 - Hayward Flow Control

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DAB Series True Union Diaphragm Valves1/2" to 2" PVC, CPVC, PP and PVdFkey FeatUReS• PVC, CPVC, PP and PVDF• Position Indicator• Sure-Grip Handwheel• Choice of FPM, EPDM orPTFE Diaphragms*oPtionS• Electric or Pneumatic Actuation• PVDF Vapor Barrier*** All PTFE diaphragms are EPDM backed** PVDF Vapor Barrier available with EPDMand PTFE diaphragm onlySELECTION CHARTSize1/2" – 2"(DN15 – DN50)1/2" – 2"(DN15 – DN50)MateRialPVC or CPVCPP or PVDFendConneCtionSocket andThreadedThreadeddiaPhRagM SealSPReSSUReRatingFPM, EPDM,PTFE or PVDFVapor BarrierFPM orEPDM150 PSI @70°FNon-ShockFloW control VAlVesDAB Series Flanged Diaphragm Valves1/2" to 6" PVC, 1/2" to 4" CPVC, 1/2" to 10" PP and 1/2" to 8" PVdFkey FeatUReS• 1/2" to 6" PVC, 1/2" to 4" CPVC,1/2" to 10" PP and 1/2" to 8" PVDF• Position Indicator• Sure-Grip Handwheel• Choice of FPM, EPDM orPTFE Diaphragms*oPtionS• Pneumatic or Electric Actuation to 4"• Over 4" Actuation, Consult Factory• PVDF Vapor Barrier*** All PTFE diaphragms are EPDM backed** PVDF Vapor Barrier available with EPDMand PTFE diaphragm onlySELECTION CHARTSize1/2" – 4"(DN15 – DN100)6"( DN150)1/2" – 4"(DN15 – DN100)1/2" – 4"(DN15 – DN100)6" – 10"(DN150 – DN250)1/2" – 4"(DN15 – DN100)6" – 8"(DN150 – DN250)MateRialPVCCPVCPPPVDFendConneCtion diaPhRagM PReSSUReRatingFlangedFPM, EPDM,PTFE or PVDFVapor BarrierPTFE150 PSI @ 70°F Non-Shock75 PSI @ 70°F Non-Shock150 PSI @ 70°F Non-Shock150 PSI @ 70°F Non-Shock75 PSI @ 70°F Non-Shock150 PSI @ 70°F Non-Shock75 PSI @ 70°F Non-ShockSV Series True Union Solenoid Valves1/4" to 1" PVC and CPVCkey FeatUReS• PVC and CPVC• Continuous or 100%Duty Applications• Corrosion-Resistant Polyester Coil• No Pressure Differential Requiredfor Operation• Both 1/2" Conduit or SJ-Type CordElectrical Connection• 110 VAC StandardoPtionS• 12 VAC, 24 VAC, 220 VAC,12 VDC, 24 VDCoPeRating PaRaMeteRSFor optimum valve performance, inlet pressure must not exceed120 PSI. <strong>Flow</strong> velocity must 1Anot exceed 5 ft. per second.SELECTION CHARTSize1/4", 1/2", 3/4", 1"(DN8 – DN25)MateRialPVC or CPVCendConneCtionSocket andThreadedSealSFPM orEPDMPReSSUReRating150 PSI @ 70°FNon-Shock1.888.429.4635 • www.haywardflowcontrol.com1B11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!