12.07.2015 Views

CR Custom - Grundfos

CR Custom - Grundfos

CR Custom - Grundfos

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

GRUNDFOSPRODUCT GUIDE<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N<strong>Custom</strong>-built pumps60 Hz


ContentsProduct data<strong>Custom</strong>-built pumps 3Variant overview 3Performance range 4Type keys 5Codes 5How to read a curve chart 6Curve conditions 6MotorsGeneral information 7Efficiency class 8Benefits offered by high efficiency motors 8Pump range 8NEMA TEFC Motor Efficiency Standards &Baldor Super-E Efficiency 8Shaft seal arrangementsDouble seal (tandem) 9Double seal (back-to-back) 10Back-to-back double sealwith pressure intensifier 11Back-to-back double seal with dosing pump 11Cool-Top® (high temperatures) 12Shaft sealsShaft seal with FFKM or FXM O-ring material 14Hybrid shaft seal 15CertificatesCertificates 16ATEX-approved <strong>CR</strong> pumps 17MAGdriveMagnetic-drive pump (MAGdrive) 18PumpsHorizontally mounted pumps 20Pumps with bearing flange 22Belt-driven pumps 24Pumps for liquid temperaturesdown to –40°F 26Carbon-free pumps 27Silicon-free pumps 27Pumps for pharmaceutical andbiotechnological applications 28TriClamp 28Cleaned and dried pumps 29Electropolished pumps 29Low-NPSH pumpsLow-NPSH pumps 30Performance curves 31<strong>CR</strong> 3 31<strong>CR</strong> 5 32<strong>CR</strong> 10 33<strong>CR</strong> 15 34<strong>CR</strong> 20 35<strong>CR</strong> 32 36<strong>CR</strong> 45 37<strong>CR</strong> 64 384-pole versions<strong>CR</strong> pumps with 4-pole motors 39Performance curves 40<strong>CR</strong> 1 40<strong>CR</strong> 3 41<strong>CR</strong> 5 42<strong>CR</strong> 10 43<strong>CR</strong> 15 44<strong>CR</strong> 20 45<strong>CR</strong> 32 46<strong>CR</strong> 45 47<strong>CR</strong> 64 48<strong>CR</strong> 90 49LiqTecLiqTec TM dry-running sensor 192


Product data<strong>Custom</strong>-built pumps<strong>Custom</strong>-built pumps<strong>Grundfos</strong> offers a wide range of custom-built variants ofthe <strong>CR</strong> type range for a variety of demanding industrialapplications. Featuring superior reliability like thestandard products, the custom-built pumps meet thestrictest demands for durability and trouble-free operation.With these multistage in-line pumps, based on the wellknown<strong>CR</strong> type range, <strong>Grundfos</strong> meets the customers’needs for pumps capable of handling• high-temperature liquids• high-viscosity liquids such as paints and varnishes• volatile and explosive liquids and• aggressive liquids• special installation requirements.The <strong>Grundfos</strong> <strong>CR</strong> rangeMaterial versions:• Cast iron/stainless steel, AISI 304 = <strong>CR</strong>• Stainless steel, AISI 304 = <strong>CR</strong>I• Stainless steel, AISI 316 = <strong>CR</strong>N• Titanium = <strong>CR</strong>TPump types:<strong>CR</strong> 1s, 1, 3, 5, 10, 15, 20, 32, 45, 64 and 90.Pumped liquid temperature:–40°F to +356°F.This product guide gives an overview of some of thecustom-built solutions offered by <strong>Grundfos</strong>. If theproduct guide does not provide a solution to yourspecific pumping needs, please contact your local<strong>Grundfos</strong> company with a detailed description of yourapplication!Variant overviewThe overview of custom-built solutions refers only tothe <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N range.The overview is divided into the following parts:• Motors• Shaft seals• Pumps.MotorsThe standard range of motors meets a wide variety ofapplication demands.For special applications or operating conditions,<strong>Grundfos</strong> offers custom-built motors such as• explosion-proof motors for hazardous atmospheres(including ATEX approved motors)• motors with anti-condensation heating unit for humidenvironments• High efficiency motors• Motors with different enclosure class• Oversized motors• motors with thermal protection.Shaft seals<strong>Grundfos</strong> offers a wide range of special-purpose shaftseals and shaft seal arrangements for the pumping ofliquids such as• aggressive or corrosive liquids• particle-carrying liquids• toxic or explosive liquids• high-viscosity or sticky liquidsand for operating under conditions such as• extremely high pressures• extremely high or low temperatures.PumpsThe pump can be custom-built for special operatingconditions and applications such as• high inlet pressures• high-pressure systems up to 725 psi• horizontal mounting• applications demanding belt-driven pumps• pharmaceutical and biotechnological applications• applications requiring low NPSH.GR53573


Product data<strong>Custom</strong>-built pumpsPerformance rangeH[m]400300200H[ft]1500100080060060 Hz1008040030060504030202001501008060<strong>CR</strong> 1s <strong>CR</strong> 3<strong>CR</strong> 10<strong>CR</strong>I 1s<strong>CR</strong>N 1s<strong>CR</strong> 1<strong>CR</strong>I 1<strong>CR</strong>N 1<strong>CR</strong>I 3<strong>CR</strong>N 3<strong>CR</strong> 5<strong>CR</strong>I 5<strong>CR</strong>N 5<strong>CR</strong>I 10<strong>CR</strong>N 10<strong>CR</strong> 15<strong>CR</strong>I 15<strong>CR</strong>N 15<strong>CR</strong> 32<strong>CR</strong> 64<strong>CR</strong>N 32 <strong>CR</strong>N 644 6 8 10 20 30 40 60 80 100 200 300 400 600 800Q [US GPM]<strong>CR</strong> 20<strong>CR</strong>I 20<strong>CR</strong>N 20<strong>CR</strong> 45<strong>CR</strong>N 45<strong>CR</strong> 90<strong>CR</strong>N 90Eta[%]801 2 3 4 5 6 8 10 20 30 40 50 60 80 100Q [m³/h]60402004 6 8 10 20 30 40 60 80 100 200 300 Q [US GPM]High-pressure rangeTM02 8376 51034


Product data<strong>Custom</strong>-built pumpsType keys<strong>CR</strong>(E), <strong>CR</strong>I(E), <strong>CR</strong>N(E)CodesExample <strong>CR</strong> E 32 (s) -4 -2 -A -G -G -E -HQQEType range:<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>NPump with integratedfrequency controlFlow rate [m 3 /h]All impellers with reduceddiameter (applies only to <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s)Number of impellersNumber of reduced diameterimpellers (<strong>CR</strong>(E), <strong>CR</strong>N(E) 32, 45, 64, 90)Code for pump versionCode for pipe connectionCode for materialsCode for rubber partsCode for shaft sealExample A -G -G -E -H QQ EPump versionA Basic version 1)B Oversize motorE Certificate/approvalF<strong>CR</strong> pump for high temperatures(air-cooled top assembly)H Horizontal versionHSHigh-pressure pump with highspeed MLE motorI Different pressure ratingJ Pump with different max speedK Pump with low NPSHM Magnetic driveN Fitted with sensorP Undersize motorR Horizontal version with bearing bracketSF High pressure pumpTOver size motor(two flange sizes bigger)U NEMA version 1)X Special versionPipe connectionA Oval flangeB NPT threadCA FlexiClamp (<strong>CR</strong>I(E), <strong>CR</strong>N(E) 1, 3, 5, 10, 15, 20)CX Triclamp (<strong>CR</strong>I(E), <strong>CR</strong>N(E) 1, 3, 5, 10, 15, 20)F DIN flangeG ANSI flangeJ JIS flangeN Changed diameter of portsP PJE couplingX Special versionExample A -G -G -E -H QQ EMaterialsA Basic versionD Carbon-graphite filled PTFE (bearings)G Wetted parts AISI 316GIAll parts stainless steel, wettedparts AISI 316I Wetted parts AISI 304IIAll parts stainless steel, wettedparts AISI 304K Bronze (bearings)S SiC bearings + PTFE neck ringsX Special versionCode for rubber partsE EPDMF FXMK FFKMV FKMShaft sealA O-ring seal with fixed driverB Rubber bellows sealE Cartridge seal with O-ringH Balanced cartridge seal with O-ringK Metal bellows cartridge sealO Double seal, back-to-backP Double seal, tandemX Special versionB Carbon, synthetic resin-impregnatedH Cemented tungsten carbide, embedded (hybrid)Q Silicon carbideU Cemented tungsten carbideX Other ceramicsE EPDMF FXMK FFKMV FKM1) In August 2003 the NEMA version pump code was discontinued for allmaterial numbers created by <strong>Grundfos</strong> manufacturing companies inNorth America. The NEMA version pump code will still remain in effectfor existing material numbers. NEMA version pumps built in NorthAmerica after this change will have either an A or U as the pump versioncode depending on the date the material number was created.5


Product data<strong>Custom</strong>-built pumpsHow to read a curve chartPump type and frequencyNumber of stagesFirst figure indicates number ofstages, second figure indicatesnumber of reduced-diameterimpellers.H[m]6050403020H[ft]2202001801601401201008060-2-2-1<strong>CR</strong> 32<strong>CR</strong>N 322-pole, 60 HzH[ft]2202001801601401201008060QH curves for the individual pumps.The bold curves indicate the recommendedperformance range for bestefficiency.The thin curves are only to be used asa guide.10The power curves indicatepump input power per stage. 0Chart shows curve for pumpwith full-diameter impeller (1/1)and reduced-diameter impeller(2/3).P2[kW]21040200P2[hp]432100 20 40 60 80 100 120 140 160 Q [US GPM]0 5 10 15 20 25 30 35 40 Q [m³/h]Eff 1/12/30 20 40 60 80 100 120 140 160 Q [US GPM]40200Eff[%]806040200The eff. curve shows pump efficiency.The efficiency of pumpswith reduced-diameter impellersis approx. 2% lower than the eff.curve shown in the chart.H[m]840NPSH[ft]3020100NPSHR0 20 40 60 80 100 120 140 160 Q [US GPM]NPSH[ft]3020100The NPSH curve is an averagecurve for all the variants shown.When sizing the pumps, add asafety margin of at least 2 feet.TM02 8377 5103Curve conditionsThe guidelines below apply to the curves shown in thisdata booklet.1. The motors used for the measurements are the sameas the motors used in the standard range.2. Performance may vary based on motor selection.3. Measurements have been made with airless water ata temperature of 68°F.4. The curves apply to a kinematic viscosity ofυ = 1 mm 2 /s (1 cSt).5. Due to the risk of overheating, the pumps shouldnot be used at a flow below the minimum flow rate.The curve below shows the minimum flow rate as apercentage of the nominal flow rate in relation to theliquid temperature.The dotted curve represents a pump fitted with an aircooledtop.Qmin[%]302010010440 140 60 176 80 212 248 120 284 140 160 320 180 356 t [°F]TM02 7538 37036


Motors<strong>Custom</strong>-built pumpsGeneral informationThe <strong>Grundfos</strong> standard range of motors covers a widevariety of application demands. For special applicationsor operating conditions, <strong>Grundfos</strong> offers custom-builtmotors, such as:VariantDescriptionIf technically possible, <strong>Grundfos</strong> can fit the pump with a motor of a brand other than theDifferent motor brandstandard. This will normally increase the time of delivery. Alternatively, the pump can besupplied without a motor (motor thrust rating must be checked).Different position of motorWhere possible, the terminal box can be placed on either side of the pump.Explosion-proof motorFor operation in hazardous atmospheres.As standard, <strong>Grundfos</strong> can supply:• ODP: open drip-proof; TEFC: total-enclosed fan-cooledOn request, we can supply:Different enclosure class• Chemical processing/mill and chem duty• Washdown duty (Up through 10 hp only)• OtherAnti-condensation heatingBuilt-in heating unit, especially for humid environments.(space heaters)All heating units are supplied with 1 x 115V, 60Hz.All <strong>Grundfos</strong> <strong>CR</strong> pumps 10 hp and below are available as standard with an integrated variableIntegrated variable speed drivespeed drive (type MLE) motor.Special supply voltageMotors suitable for other voltages are available upon request.Motor insulation class Upgrade from Class F to Class H.• EPAct/NRC—motor efficiency according to EPAct/NRC standardsEfficiency class• Premium efficiencyAmbient temperatures above 104° F or installation at altitudes of more thanOversized motor3,300 feet above sea level may require the use of an oversized motor (i.e. derating).Tropicalized windingsMotors recommended for operating in areas with high humidity.Wye/Delta startingMotor wired for Wye/Delta starting (6 leads).<strong>Grundfos</strong>’ laboratory is authorized to issue test sheets for motors; for instance,Test sheetsfor insurance companies.7


Motors<strong>Custom</strong>-built pumpsEfficiency class<strong>Grundfos</strong> offers motors with Energy Efficient EPAct/NRCclass and Premium Efficiency class. When Premium Efficiencymotors are ordered, the Baldor Super-E® motor issupplied which in most cases exceeds the NEMA PremiumEfficiency standards.Benefits offered by high efficiency motors• Improved efficiency (see graph below)• Lower noise level• Higher permissible ambient temperature• Longer bearing life due to reduced temperatureNEMA TEFC Motor Efficiency Standards & Baldor TEFC Super-E EfficiencyPump rangeEnergy Efficient and Premium Efficiency motors areavailable for all <strong>Grundfos</strong> <strong>CR</strong> pumps.Pump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90type<strong>CR</strong> • • • • • • • • • • •<strong>CR</strong>I • • • • • • •<strong>CR</strong>N • • • • • • • • • • •10095Efficiency (%)90858075701 1,5 2 3 5 7,5 10 15 20 25 30 40 50 60HPTEFC EPAct/NRC TEFC Premium Eff. TEFC Super-ENote: ODP Efficiency points are in table below.HPODPTEFCEPAct/NRC Premium Eff. Super-E EPAct/NRC Premium Eff. Super-E1 -- 77.0 84.0 75.5 77.0 78.51 1/2 82.5 84.0 85.5 82.5 84.0 85.52 84.0 85.5 86.5 84.0 85.5 86.53 84.0 85.5 87.5 85.5 86.5 88.55 85.5 86.5 90.2 87.5 88.5 89.57 1/2 87.5 88.5 90.2 88.5 89.5 91.010 88.5 89.5 91.7 89.5 90.2 91.715 89.5 90.2 91.7 90.2 91.0 91.720 90.2 91.0 92.4 90.2 91.0 92.425 91.0 91.7 93.0 91.0 91.7 93.030 91.0 91.7 93.6 91.0 91.7 93.040 91.7 92.4 94.1 91.7 92.4 93.650 92.4 93.0 93.6 92.4 93.0 94.160 93.0 93.6 94.5 93.0 93.6 94.1Notes:1. The term “High Efficiency” is commonly used but is not recognized in the NEMA standards (MG 1-1198, Part 12).2. Some standard <strong>CR</strong> pump motors already meet the EPAct/NRC requirement. See the <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N Product Guide.NEMA Baldor TEFC Super-E Motor EfficiencyStandards &8


•• ••Shaft seal arrangements<strong>Custom</strong>-built pumpsDouble seal (tandem)<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10, 15 and 20General informationDouble seals mounted in tandem are recommended foruse with crystallizing, hardening or sticky liquids.Reference applications• Pharmaceutical industry (production of dextran)• Negative pressure deaeration systems (vacuum)• Industries handling potentially hardening oilproducts• Caustic soda (sodium hydroxide - NaOH)• Hydrated lime (calcium hydroxide - Ca(OH) 2 ).Pump rangeThe tandem type of seal is available for the following<strong>Grundfos</strong> pumps:Pump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90type<strong>CR</strong> • • • • • • • • • • •<strong>CR</strong>I • • • • • • •<strong>CR</strong>N • • • • • • • • • • •Technical descriptionThis type of double seal consists of two shaft sealsmounted in a tandem arrangement in a separate sealchamber. Only <strong>Grundfos</strong> cartridge shaft seals can beused.Outlet 1/2"<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90Outlet 3/8"Inlet 3/8"Inlet 1/2"TM02 7386 3403If the primary seal is leaking, the pumped liquid will beflushed away by the flushing liquid. The flushing liquidpressure must always be lower than the pumped liquidpressure.Recommended flushing liquid conditions:• Q = 6.6-52.8 gallon/hour• p = 58-87 psiSectional drawings<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3 and 5Outlet 1/2"DimensionsPump typeAdditional height of seal chamber *[in]<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3 and 5 4 1/4<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10, 15 and 20 3 1/2<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90 0*This dimension is the additional height as compared to the standardpump.TM01 6204 1699Reference numbersPump typeReference number<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3 and 5 98 97 08<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10, 15 and 20 98 94 70<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90 98 98 05Inlet 1/2"TM02 2139 37019


•Shaft seal arrangements<strong>Custom</strong>-built pumpsDouble seal (back-to-back)General informationSectional drawings<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3 and 5Double seals mounted "back-to-back" are recommendedfor use with toxic, aggressive or explosive liquids. Theback-to-back double seal protects the surrounding environmentand the people working in the vicinity of thepump.Shaft sealThis type of seal is the optimum solution for handlingabrasive or sticky liquids which would either wear out,damage or block a mechanical shaft seal.Reference applications• Paint industry• Distilling plants• Petrochemical industry.Pump range<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10, 15 and 20Shaft sealTM02 1691 1801The back-to-back type of seal is available for thefollowing <strong>Grundfos</strong> pumps:Pumptype<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90Shaft seal<strong>CR</strong> • • • • • • • • • • •<strong>CR</strong>I • • • • • • •<strong>CR</strong>N • • • • • • • • • • •Technical descriptionShaft sealThe back-to-back double seal consists of two shaft sealsmounted in a back-to-back arrangement in a separateseal chamber.The pressure in the seal chamber must be higher thanthe pump pressure. The pressure in the seal chamber canbe generated by<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90TM02 7385 3403• a pressure intensifier when the operating pressure isabove 232 psi (see page 12)Shaft seal• a separate pump, e.g. a dosing pump, when the operatingpressure is less or equal to 232 psi (see page 12)or• an existing, separate pressure source. Many applicationsincorporate pressurized systems.The back-to-back double seal arrangement with pressurizedseal chamber prevents the pumped liquid fromleaking through the shaft seal to the environment.Reference numbersPump typeReference number<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N, 1s, 1, 3 and 5 98 97 09<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N, 10, 15 and 20 98 94 71<strong>CR</strong> 32, 45, 64 and 90 98 98 10<strong>CR</strong>N 32, 45, 64 and 90 98 97 87TM02 5000 200210


Shaft seal arrangements<strong>Custom</strong>-built pumpsBack-to-back double sealwith pressure intensifierBack-to-back double sealwith dosing pumpPressure intensifierDouble seal<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N pumpTM01 4455 0399Barrier fluidtm01 9099 1701DimensionsPump typeThe dimension b is the additional height as compared tothe standard pump.Reference numbersaa[in]b[in]c[in]<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3 and 5 11 3/4 4 1/4 5<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N, 10, 15 and 20 12 3/4 3 1/2 5 1/2<strong>CR</strong>, <strong>CR</strong>N 32 13 1/2 8 1/4 6<strong>CR</strong>, <strong>CR</strong>N 45 13 3/4 9 1/2 6 1/2<strong>CR</strong>, <strong>CR</strong>N 64 13 3/4 6 1/2 6 1/2<strong>CR</strong>, <strong>CR</strong>N 90 14 7 1/4 6 3/4bcTM01 4459 0399Note: One dosing pump installation can supply severalpumps fitted with back-to-back double seal.Connections are all ½".Note: Connecting pipes/hoses are not included.DimensionsPump typeReference numbersAdditional height of seal chamber *[in]<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3, 5 4 1/4<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N, 10, 15 and 20 3 1/2<strong>CR</strong>, <strong>CR</strong>N 32 8 1/4<strong>CR</strong>, <strong>CR</strong>N 45 9 1/2<strong>CR</strong>, <strong>CR</strong>N 64 6 1/2<strong>CR</strong>, <strong>CR</strong>N 90 7 1/4*This dimension is the additional height as compared to the standardpump.Dosing pump,max. 232 psiReference number98 98 09Pressure intensifier(not available for <strong>CR</strong>T)Material Reference numberAISI 316, FKM 98 98 92AISI 316, EPDM 98 98 9111


Shaft seal arrangements<strong>Custom</strong>-built pumpsCool-Top® (high temperatures)Temperatures above 248°F normally result in a substantialreduction of seal life due to poor lubrication of theseal faces. As the temperature in the seal chamber doesnot exceed 248°F during operation, a standard <strong>Grundfos</strong>shaft seal can be used.The <strong>Grundfos</strong> air-cooled top does not require anyexternal cooling. An automatic air vent is required tovent the pump seal chamber.Air-cooled top with bearing flangeFor applications involving pumping of water up to 356°F,the pump requires a net positive inlet pressure,according to the vapor pressure of water.To prevent the axial thrust generated by the inlet pressurefrom being transmitted to the motor shaft andbearings, a bearing flange can be fitted between pumpand motor.General informationThe unique <strong>Grundfos</strong> air-cooled top shaft seal solution isrecommended for applications involving high temperaturesfrom 248°F to 356°F.The Cool-Top pumps are equipped with FXM rubberparts.Reference applications• Boiler feeding• Temperature control, e.g. in molding processes• Circulation of transmission oils.Pump rangeThe Cool-Top is available for the following <strong>Grundfos</strong>pumps:248-356°FPump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90type<strong>CR</strong> • • • •<strong>CR</strong>I • • • • • • •<strong>CR</strong>N • • • • • • • • • • •GR5228A bearing flange may be required if the application inletpressure exceeds the maximum inlet pressure of thepump. This is common for pumps with 1 or 2 impellers.Refer to the <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N Product Guide for maximumpermissible inlet pressures for all <strong>CR</strong> pumps.The max. permissible operating pressure of pumps withair-cooled top for temperatures up to 356°F is 362 psi.DimensionsPump typeAdditional pump height *[in]<strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3 and 5 4 1/4<strong>CR</strong>I, <strong>CR</strong>N 10, 15 and 20 3 1/2<strong>CR</strong>, <strong>CR</strong>N 32 8 1/4<strong>CR</strong>, <strong>CR</strong>N 45 9 1/2<strong>CR</strong>, <strong>CR</strong>N 64 6 1/2<strong>CR</strong>, <strong>CR</strong>N 90 7 1/4*This dimension is the additional height as compared to the standardpump.Reference numbers, air-cooled top for 248-356°FPump typeReference number<strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3 and 5 98 96 40<strong>CR</strong>I, <strong>CR</strong>N, 10, 15 and 20 98 94 73<strong>CR</strong> 32, 45, 64 and 90 98 96 38<strong>CR</strong>N 32 and 45 98 96 37<strong>CR</strong>N 64 and 90 98 96 36Technical descriptionThe air-cooled top separates the seal chamber from thepump by an air-cooled chamber, generating an insulatingeffect similar to that of a thermos.Via the narrow passage between the pump and the aircooledtop, a small quantity of the pumped liquid recirculatesby natural circulation.12


•••• •••••Shaft seal arrangements<strong>Custom</strong>-built pumpsSectional drawings<strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3 and 5 <strong>CR</strong>I, <strong>CR</strong>N 10, 15 and 20Air vent 1/2"Air ventLiquidShaft sealLiquidShaft sealAir chamberBushingAir chamberPipeTM02 1693 1801TM02 7384 3403<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90Air vent 1/2"Shaft sealLiquidAirchamberPipeBushingTM01 4785 089913


Shaft seals<strong>Custom</strong>-built pumpsShaft sealsGeneral informationLiquids or applications exceeding the range of normaloperating conditions require special-purpose shaft sealsolutions.To ensure reliability and avoid untimely breakdowns,the following conditions must be considered:• temperature,• pressure,• pumped liquid.In order to meet any specific requirements, <strong>Grundfos</strong>offers the following variants:1. Shaft seals with FFKM or FXM O-ring material2. Hybrid shaft sealsRecommended operating rangeThe actual operating range of the shaft seal depends onthe operating pressure, pump type, type of shaft sealand liquid temperature. The following table applies toclean water and water containing glycol.For explanation of codes, see the type key on page 5.Pump type<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N1s, 1, 3, 5, 10, 15, 20,32, 45, 64, and 90Shaft sealMin.temp.[°F]Max.temp.[°F]Pressurerating[psi]HUBx 32 248 435HUUx –40 194 435HQQx –40 248 435HQBx 0 248 435Rubber type Min. temperature [°F] Max. temperature [°F]EPDM –40 248FKM –4 194FXM 14 527FFKM –4 527Maximum operation temperature is 248°F for the standard range.For pumps equipped with a Cool-Top the maximumoperation temperature is 356°F.Shaft seal with FFKM or FXM O-ringmaterialGeneral informationShaft seals with FFKM or FXM O-ring material are recommendedfor applications where the pumped liquids maydamage the standard O-ring material.See the list of pumped liquids in the <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N databooklet.Reference applications, FFKM (Kalrez®)• Chemical industry (aggressive liquids)• Petrochemical industry (oils)• High-temperature applications.Plug and sleeve O-rings made of FFKM are also availablefor <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3, 5, 10, 15 and 20.Reference applications, FXM (Flouraz®)• High-temperature applications (instead of FKM).Plug and sleeve O-rings made of FXM are available forthe full range.Pump rangeShaft seals with FFKM or FXM O-ring are available for thefollowing <strong>Grundfos</strong> pumps:Pump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90typeFFKM • • • • • • • • • • •FXM • • • • • • • • • • •Technical descriptionThe FFKM and FXM O-rings replace the standard shaftseal O-rings.DimensionsDimensions are identical to those of the standard shaftseal.Reference numbersReference numberPump typeFFKMFXM<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3 and 5 98 99 72 98 96 78<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10, 15 and 20 98 94 74 98 94 75<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90 98 98 15 98 96 7714


Shaft seals<strong>Custom</strong>-built pumpsHybrid shaft sealSectional drawingGeneral informationHybrid shaft seals are recommended for applicationsinvolving a risk of dry running and are available as astandard shaft seal on <strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90; sealtype KUHE.Reference applications• Boiler-feed applications• Applications involving degassing of liquids• Industrial applications involving frequent priming.Pump rangeHybrid shaft seals are available for the following<strong>Grundfos</strong> pumps:Pump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90type<strong>CR</strong> • • • •<strong>CR</strong>I<strong>CR</strong>N • • • •DimensionsHybrid seal designDimensions are identical to those of the standard shaftseal.TM02 4279 0402Technical descriptionThe stationary seat of the shaft seal is equipped with anextra, special-carbon seal face, expanding at hightemperatures as a result of dry running or similar conditions.This eliminates the usual damaging effects of dryrunning, such as leakage and noise.Reference numbersPump type<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90Reference numberStandard15


PosRMS vibrationvelocity (mm/s)Part no 96 51 22 40/A53123RMS vibrationClass IClass IIvelocity (mm/s)0.280.45AA0.711.12B1.8B2.8C4.5C7.111.218DD2845The machine classifications are as follows:Class I: Individual parts of engines and machines, integrallyconnected to the complete machine in its normal operatingcondition. (Production electrical motors of up to 15 kW aretypical examples of machines in this category.)Class II: Medium-sized machines (typically electrical motorswith 15 kW to 75 kW output) without special foundations,rigidly mounted engines or machines (up to 300 kW) on specialfoundations.Part no 96 50 79 32/A53123Part no 96 50 79 31/A53123Certificates<strong>Custom</strong>-built pumpsCertificatesATEX-approved pump<strong>Custom</strong>er name<strong>Custom</strong>er order no.<strong>Grundfos</strong> order no.Pump typePart numberProduction codePump serial no.Motor serial no.ATEX approval of pump<strong>Grundfos</strong> hereby confirms that the pump mentioned above is manufactured according thespecifications mentioned in the “<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N <strong>Custom</strong>-built pumps” data booklet. This meansthe pump is conformity with the ATEX 94/9EEC (ATEX 100) appendix VIII directive as mentionedin the “ATEX Supplement to installation and operating instructions” supplied with thepump.Surface roughnessAccording to ISO 1302<strong>Custom</strong>er name<strong>Custom</strong>er order no.<strong>Grundfos</strong> order no.Pump typePart number<strong>CR</strong>N base part numberThe surface roughness is measured as the maximum roughness of the <strong>CR</strong>N inlet and outletsurface.GRUNDFOSDate:Signature:Name:Dept.:BAGR5381Surface TreatmentRoughnessRoughnessvalue RA [µm]degreeNoneElectro-polished 50 N 1225 N 1112.5 N 10Measured values A 6.3 N 9R max [µm] 3.2 N 8R A [µm] 1.6 N 7R Z [µm] 0.8 N 60.4 N 5Measured values A 0.2 N 4R max [µm] 0.1 N 3R A [µm] 0.05 N 2R Z [µm] 0.025 N 1Vibration reportAccording to ISO 10816General information<strong>Grundfos</strong> offer a number of certificates for differentpurposes. The following types are available...• material certificates( certificates stating material components ormaterial specifications)• performance certificates(printed test reports guaranteeing and certifying testdata of QH performance, current consumptioncurves, rpm, etc.)• authorized test by third party(surveyed performance test)• ATEX approved <strong>CR</strong> pumps(according to ATEX-directive 94/9/EC)The certificates must be ordered with the pump.Reference applications• Pharmaceutical industries• Ships and offshore• Big contractors• Areas exposed to explosive atmospherePump rangeCertificates are available for the following pump types:Pump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90type<strong>CR</strong> • • • • • • • • • • •<strong>CR</strong>I • • • • • • •<strong>CR</strong>N • • • • • • • • • • •Measured objectPump typeP2 (kW)Number of polesTest conditionsThe pump is floormountedon vibrationabsorbers.RemarksResult of measurement:Part numberFrequency (Hz)Serial no.Voltage (V)Frequency: (Hz)Flow (m³/h)Head (m)For vibration velocity measurement positions, see figure.123456789Typical zone boundry limitsGRUNDFOSDate:Signature:Name:Dept.:GRUNDFOSDate:Signature:Name:Dept.:CertificateStandardMaterial specification reportMaterial report with certificateReportATEX-approved pumpInspection certificateEN 10.204 3.1.BInspection certificate- Lloyds Register of Shipping (LRS),- Det Norske Veritas (DNV)EN 10.204 3.1.C- Germanisher Lloyd (GL)- Bureau Veritas (BV)- Etc.....Surface roughness reportMotor test reportStandard test report ISO 9906Vibration reportCertificate of compliance with theEN 10.204 2.1orderTest report - non specific inspectionEN 10.204 2.2and testingReportCleaned and dried pumpReportElectro-polished pump25-Jun-0416


Certificates<strong>Custom</strong>-built pumpsATEX-approved <strong>CR</strong> pumpsGeneral informationThe <strong>CR</strong> pumps can be approved according to EC directive94/9/EC, the so-called ATEX directive.The pumps can be used in areas (zones) classifiedaccording to the directive 1999/92/EC. In case of doubt,please consult the above-mentioned directives orcontact <strong>Grundfos</strong>.ATEX-approved pumps will be supplied with serialnumber, special installation and operating instructionsand a nameplate including the ATEX classification.An ATEX-approved pump report is available on request.Scope of ATEX categories for <strong>CR</strong> pumpsGroup IUnderground installations in mines liableto be endangered by explosive gassesor combustible dust.Category M2Pumps made of materials thatdo not create sparks and thus donot constitute any danger ofexplosion.<strong>CR</strong> pumps available<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>NMotors availableNone** Air or hydraulic motors are not available from <strong>Grundfos</strong>.Group IIInstallation areas liable to be endangeredby explosive atmospheres.Category 2 Category 3Pumps intended for use in areas in whichexplosive atmospheres are likely to occur.Pumps intended for use in areas in whichexplosive atmospheres only rarely occur.G (gas) D (dust) G (gas) 2) D (dust)<strong>CR</strong> pumps available <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1) <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N, <strong>CR</strong>T <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N, <strong>CR</strong>T <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N, <strong>CR</strong>TMotors availableVEM 2G EEx e IIT3CEMP 2G EEc d IIB T4VEM 2D 125°CVEM 2G EEx e IIT3CEMP 2G EEc d IIB T4VEM 3D 125°C1)2)Solutions including MAGdrive or double shaft seal.Note: To enable the use of category 3 G <strong>CR</strong> pumps in zone 1 areas, the minimum requirement is a dry-running protection approved for zone 1.The dry-running protection must stop the pumps if the liquid supply ceases.17


MAGdrive<strong>Custom</strong>-built pumpsMagnetic-drive pump (MAGdrive)General informationThe zero-leakage, custom-built pump with magneticdrive (MAGdrive) is recommended for the pumping ofhazardous or aggressive liquids. <strong>Grundfos</strong> MAGdriveprotects the surrounding environment and the peopleworking in the vicinity of the pump.Reference applications• Chemical industry (aggressive or toxic liquids)• Petrochemical industry (volatile liquids)• Pharmaceutical industry.Pump rangeThe following <strong>Grundfos</strong> pumps are available withMAGdrive:Pump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90type<strong>CR</strong><strong>CR</strong>I<strong>CR</strong>N • • • •Technical descriptionIn the <strong>Grundfos</strong> MAGdrive pump, the power from themotor is transmitted to the pump shaft by means ofmagnetic force instead of by a traditional coupling. Themagnetic field is generated by two magnets; the outermagnet is driven by the motor and the inner magnet isconnected to the pump. Due to the power loss, theMAGdrive is cooled by the pumped liquid.As all axial forces are absorbed in the MAGdrive, astandard motor with key hole must be used.<strong>Grundfos</strong> MAGdrive is based on a standard MAK 66magnetic Burgmann coupling.Sectional drawingPump shaft250265CanBearing258Axial bearing 259MagnetsTM02 1721 1901DimensionsStandard motor[Hp]Operating rangePump typeReference numbersMAGdrive motor[Hp]Additional height[in]1/2 3/4 3 1/81/2 1 4 3/41/2 1 1/2 4 3/43/4 1 1/2 4 3/43/4 2 7 1/31 1 1/2 2 7/81 2 5 1/21 1/2 1 1/2 2 7/81 1/2 2 5 1/21 1/2 3 5 1/22 2 2 7/82 3 2 7/83 3 2 7/83 4 54 4 2 3/44 5 1/2 4 3/45 1/2 5 1/2 2 3/45 1/2 7 1/2 47 1/2 7 1/2 27 1/2 10 210 10 2Viscosity range[cp]Max. pressure[psi]Temp. range[°F]<strong>CR</strong>N 1s, 1, 3 and 5 0.3 - 150 232/362 –22 to +356Pump typeReference number<strong>CR</strong>N 1s-2 to <strong>CR</strong>N 1s-27 98 94 82<strong>CR</strong>N 1-2 to <strong>CR</strong>N 1-27 98 97 07<strong>CR</strong>N 3-2 to <strong>CR</strong>N 3-25 98 97 05<strong>CR</strong>N 5-2 to <strong>CR</strong>N 5-12 98 97 03<strong>CR</strong>N 5-13 to <strong>CR</strong>N 5-24 98 97 02The following rubber part solutions are available:• EPDM• FXM• FFKM• FKM.Note: When ordering a <strong>Grundfos</strong> MAGdrive, pleaseprovide the following:• liquid temperature [°F]• liquid viscosity [cp]• frequency [Hz]• voltage [V].Above information is required for the selection of thecorrect MAGdrive/motor combination.18


LiqTec<strong>Custom</strong>-built pumpsLiqTec TM dry-running sensorGeneral informationThe <strong>Grundfos</strong> LiqTec dry-running sensor stops the pumpimmediately if• there is no liquid in the pump (dry-running)• the liquid temperature exceeds 266°F ±9°F• the sensor, sensor cable, electronic unit or powersupply failsWhen connected to the PTC sensors in the motor, theLiqTec also protects the motor against overheating.The sensor is easily inserted through the pump headclose to the shaft seal.TM03 0110 4004Restarting after a pump cut-out can be done automaticallyor manually when liquid in the pump is againdetected by the sensor. Remote restarting is possible viaa digital input.The electronic control unit can also be connected to thepump thermistor measuring the motor temperature. Incase of overheating of the motor, the system cuts outthe pump.Installation exampleL1L2L3NSensorBrown/BlackBlueWhiteExternalrestartT+T+T+M3K1Reference applicationsAny application involving a risk of dry running.Pump rangeThe LiqTec is available for the following <strong>Grundfos</strong>pumps:Pumptype<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90<strong>CR</strong> • • • • • • • • • • •<strong>CR</strong>I • • • • • • •<strong>CR</strong>N • • • • • • • • • • •Technical descriptionThe LiqTec transmits a heat impulse through the sensor,measuring the temperature of the sensor. Liquid in thepump cools the sensor as well as the shaft seal and otherpump parts.If there is no liquid present, the LiqTec detects a hightemperature in the sensor and cuts out the pump immediately.The risk of pump breakdown is thus furtherreduced by up to 50%.The LiqTec also prevents excessive liquid temperaturesfrom damaging the pump. If the LiqTec senses a liquidtemperature above 266°F, it cuts out the pump immediately.Further the LiqTec is a failsafe device, meaningthat the pump stops as soon as the sensor detects anerror on the sensor cable, the electronics or if the powersupply of the control unit is cut off.Dimensions4 5/8 x 3 9/16 in. The LiqTec can be fitted to a DIN rail tobe incorporated in a control cabinet.Operating rangePower supplyPower consumptionMax. pressureMin./max. liquid temperatureReference numbers1 x 80-130 V, 50/60 Hz or1 x 200-240 V, 50/60 Hz5 W580 psi–4°F/266°FMax. ambient temperature 104°FHumidity 99%Pumped liquidCable lengthK1Pump typeAny water based liquid handled by<strong>Grundfos</strong> pumps16 1/2 / 49 1/4 feetTM03 00112 4004Reference number<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3, 5, 10, 15, 20, 32, 45, 64 and 90 99 96 8219


Pumps<strong>Custom</strong>-built pumpsHorizontally mounted pumpsDimensional drawings<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3, 5,<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10, 15 and 20 =7.5 HpB1BTM02 8372 5003Pump rangeThe following <strong>Grundfos</strong> pumps are available for horizontalmounting:HPump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90typeLX<strong>CR</strong> • • • • • • • • • • •<strong>CR</strong>I • • • • • • •<strong>CR</strong>N • • • • • • • • • • •Also available for <strong>CR</strong>T 2, 4, 8, 16.Technical descriptionThe pumps are supplied with separate mounting platesfor support of pump and motor.BBDBABAAAAAA8<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 904 x ø14BTM02 8373 5003Note: The following pump types are fitted with a B3 / B5foot/flange mounted motor:• <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1 to 20 with motors ≥ 10 Hp and• <strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90.Reference numbersXHLPump typeReference number<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3 and 5 98 99 51<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10, 15 and 20 = 7.5 Hp 98 94 77<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90 98 98 53ABD8256BBBAAAAAA4 x ø19TM02 7426 340320


Pumps<strong>Custom</strong>-built pumpsDimensions<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1 , 3 and 5, support for base plate and pump headMotor[hp]B[in]H[in]For pump height B1, see the <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N Product Guide.<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10, 15 and 20, support for base plate and pump headFor pump height B1, see the <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N Product Guide.L[in]<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10, 15 and 20, support for base plate and motorMotor[hp]Motor[hp]1/2-2<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90, support for base plate and motorC[in]B1-3 3/83-5 5 1/2 5 1/2 2B1-3 1/47 1/2-10 B1-4 7/8B[in]H[in]L[in]C[in]1/2-2B1-3 1/46 3/4 6 7/8 23-5 B1-4 3/8A[in]AA[in]AAA[in]B[in]BB[in]D[in]H[in]X[in]ANSIConnectionsX[in]Oval, PJE, FlexiClamp4 1/8 3 1/8<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10 <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 15/20X[in]ANSI, Oval, PJE, FlexiclampL[in]ConnectionsX[in]ANSI, Oval, PJE, Flexiclamp4 3/8 4 3/4AB[in]7 1/2 8 1/2 2 7/8 14 1/2 5 1/2 7 1/8 2 5/8 7 7/8 1 /4 10 7/810 8 1/2 2 7/8 14 1/2 5 1/2 7 1/8 2 5/8 7 7/8 1 /4 10 7/815 10 5 1/8 16 3/4 8 1/4 10 1/4 1 1/2 7 7/8 1 /4 12 3/420 10 5 1/8 16 3/4 8 1/4 10 1/4 1 1/2 7 7/8 1 /4 13 1/825 10 5 1/8 16 3/4 10 12 1/4 1 1/2 7 7/8 1 /4 13 1/8Motor[hp]A[in]AA[in]AAA[in]B[in]2 5 1/2 12 5/8 15 5 6 1/2 7 7/8 8 5/8 11 3/8 2 3/83 5 1/2 12 5/8 15 5 6 1/2 7 7/8 8 5/8 11 3/8 2 3/85 7 1/2 14 1/2 17 5 1/2 7 1/8 7 10 7/8 11 3/8 2 3/87 1/2 8 1/2 15 1/2 18 5 1/2 7 1/8 6 1/4 11 7/8 11 3/8 2 3/810 8 1/2 15 1/2 18 5 1/2 7 1/8 6 1/4 11 7/8 11 3/8 2 3/815 10 17 3/8 19 5/8 8 1/4 10 7/8 5 1/8 13 3/8 11 3/8 2 3/820 10 18 20 1/4 8 1/4 10 1/2 5 1/8 13 3/8 11 3/8 2 3/825 10 18 20 1/4 10 12 1/4 5 1/8 13 3/8 11 3/8 2 3/830 11 19 21 1/2 9 1/2 12 1/4 4 3/8 14 3/8 11 3/8 2 3/840 12 1/2 21 1/4 23 5/8 12 14 3/8 3 1/2 16 1/8 11 3/8 2 3/850 12 1/2 21 1/4 23 5/8 12 14 3/8 3 1/2 16 1/8 11 3/8 2 3/860 14 22 7/8 25 1/4 12 1/4 14 1/2 2 1/2 17 3/4 11 3/8 2 3/8BB[in]D[in]AB[in]H[in]<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10 <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 15/20X[in]ANSI, Oval, PJE, FlexiclampL[in]ConnectionsX[in]ANSI, Oval, PJE, Flexiclamp4 3/8 4 3/4<strong>CR</strong>, <strong>CR</strong>N 32 <strong>CR</strong>, <strong>CR</strong>N 45, 64, 90X[in]ConnectionANSIX[in]8 3/8 721


Pumps<strong>Custom</strong>-built pumpsPumps with bearing flangeBearing flangeThe bearing flange requires a standard motor withkeyway.Note: For motor sizes above 15 hp, the bearing flange isequipped with grease nipples and must be lubricatedregularly. Please follow the instructions on the bearingflange.Sectional drawings<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3, 5,


Pumps<strong>Custom</strong>-built pumps<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90, >10 HpDimensionsThe following additional height must be added to thetotal height of the pump:<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3, 5, 10, 15 and 20<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90NEMA 254 TSC - NEMA 365 TSCMotor typeMotor powerTM01 4353 0503Additionalheight[in]NEMA 56C/148.2 1/3 - 2 [Hp] 1 1/2NEMA F182 TC 3 - 5 [Hp] 1 3/4NEMA 213-5 TC 7 1/2 [Hp] 1 3/4NEMA 254-6 15 [Hp] 3 7/8NEMA 284-6 20-40 [Hp] 5 1/3Motor typeMotor powerAdditionalheight[in]NEMA 182 TC - NEMA 215 TC 3 - 10 [Hp] 7/8NEMA 254 TSC - NEMA 365 TSC 15 - 60 [Hp] 5/8Reference numbers<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3, 5,


Pumps<strong>Custom</strong>-built pumpsBelt-driven pumpsGeneral informationA belt-driven pump is designed to operate in places withlimited space or where no electrical power is available.Reference applicationsDiesel-engine-driven or steam-turbine-driven applicationssuch as:• applications in remote/distant areas• mobile applications• fire protection.Pump rangeThe following <strong>Grundfos</strong> pumps are available as beltdrivenpumps:Pump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90type<strong>CR</strong> • • • • • • • • • • •<strong>CR</strong>I • • • • • • •<strong>CR</strong>N • • • • • • • • • • •GR5886Technical descriptionAn additional bearing has been added on top of anexisting bearing flange. The two bearings are mountedback-to-back. This bearing design makes it possible towithstand the extra radial forces caused by a pulley.A pulley wheel is attached to the end of the shaft.By means of pulley belts, the pump can be driven by amotor mounted next to it rather than on top of it.The pump can be mounted horizontally or vertically byusing the extra support plates.The pulley head is positioned on the motor stool wherethe motor would normally be fitted. Using the existingholes in the motor stool, the pulley head can be securedto the motor stool with bolts, washers and nuts. Thepulley wheel is then attached to the shaft using anappropriate bush and key.For extended bearing life, the following pulley wheelsizes are recommended:Pulley headPump typePulley wheeldiameterType III1/2 - 7 1/2 Hp<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N1s, 1, 3, 5,10, 15, 20Type IV10 - 25 Hp<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N10, 15, 20Type II2 - 10 Hpø4 3/8- 5 3/8 Min. ø7 7/8 Min. ø6 1/4Type I15 - 60 Hp<strong>CR</strong>, <strong>CR</strong>N32, 45, 64, 90Min.ø7 7/8Number of belts 2 Min. 3 Min. 2 Min. 3Pump speed[rpm]Max 3000Also available for <strong>CR</strong>T 2, 4, 8, 16.24


Pumps<strong>Custom</strong>-built pumpsSectional drawings<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3, 5, 10, 15 and 20 (type III)<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10, 15 and 20 (type IV)TM02 4783 1602DimensionsPump typeReference numbersPulley headAdditional heightfrom top of motor stool[in]<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3, 5, 10, 15, 20 Type III 5 3/4<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10, 15, 20 Type IV 12 1/4<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90Type II 4 7/8Type I 5 7/8Pump type Pulley head Reference number<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3, 5, 10, 15, 20 Small 98 96 48<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10, 15, 20 Type II 98 94 89<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90Type II 98 96 47Type I 98 96 46For horizontal installation, the belt-driven pumps aresupplied with both brackets as standard.TM02 7451 3503<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90 (type II)TM02 4785 1602<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90 (type I)TM02 4784 160225


Pumps<strong>Custom</strong>-built pumpsPumps for liquid temperaturesdown to –40°FTechnical description<strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3, 5, 10, 15 and 20 feature• PTFE neck rings with inner diameter exceeding standarddimensions.Please note that pumped liquids containing antifreezeoften require the use of oversize motors due to thehigher viscosity of these liquids.DimensionsDimensions are identical to those of a standard pump.Reference numbersPump typeReference number<strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3 and 5 98 98 75<strong>CR</strong>I, <strong>CR</strong>N 10, 15 and 20 98 94 78GR5219General information<strong>Grundfos</strong> offers pumps suitable for the pumping ofliquids of extreme temperatures down to –40°F.Reference applications• Cooling systems with antifreeze and brines• Ventilation systems• Industrial processes.Pump rangeThe following <strong>Grundfos</strong> pumps are available for liquidtemperatures down to –40°F:Pump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90type<strong>CR</strong><strong>CR</strong>I • • • • • • •<strong>CR</strong>N • • • • • • • The standard <strong>CR</strong>N 32, 45, 64 and 90 pumps fitted with shaft seal typeHQQE are capable of operating at liquid temperatures down to –40°F.26


Pumps<strong>Custom</strong>-built pumpsCarbon-free pumpsGeneral informationCertain processes such as industrial processes in theelectronics industry require the use of pumps containingabsolutely no carbon fibers.Reference applications• Ultra-purification processes• Flushing processes in the electronics industry.Pump rangeThe following <strong>Grundfos</strong> pumps are available as carbonfreepumps:Pump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90type<strong>CR</strong> • • • •<strong>CR</strong>I <strong>CR</strong>N • • • • <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3, 5, 10, 15 and 20 are carbon-free as standard ifnon-carbon seal face material is chosen.Technical descriptionA carbon-free pump differs from a standard pump in thefollowing ways:• Bearings are made of SiC/SiC.• Neck rings and bushes are made of carbon-free PTFE(white PTFE).DimensionsDimensions are identical to those of a standard pump.Reference numbersPump type Number of stages Reference number1 - 2 98 98 02<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 903 - 7 98 96 948 - 14 98 96 93Silicon-free pumpsGeneral informationSilicon-free pumps are suitable for processes requiringthe use of pumps not containing silicon.Reference applications• Production of paint and varnish• Cleaning processes in the electronics industry.Pump rangeThe following <strong>Grundfos</strong> pumps are available as siliconfreepumps:Pump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90type<strong>CR</strong> • • • • • • • • • • •<strong>CR</strong>I • • • • • • •<strong>CR</strong>N • • • • • • • • • • •Technical descriptionA silicon-free pump differs from a standard pump in thefollowing ways:• Only FKM rubber is used.• All components, except the electric motor, arewashed in "DX 380 Low-Voc cleaner".• Spare parts ordered together with the pump are alsowashed in "DX 380 Low-Voc cleaner".• The pump is assembled in a room separated from theproduction area.• Tools used for the assembly of the pump do notcontain silicon.• The assembled pump is checked visually;performance is not tested.• The pump is wrapped in silicon-free plastic beforebeing packing.DimensionsDimensions are identical to those of the standard pump.Reference numbersPump type<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3, 5, 10, 15 and 20<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 and 90Reference number98 99 5427


Pumps<strong>Custom</strong>-built pumpsPumps for pharmaceutical andbiotechnological applicationsGeneral informationThe <strong>Grundfos</strong> <strong>CR</strong>N range is designed for applicationsrequiring the sterilization and CIP capability of pipes,valves and pumps. (CIP = Cleaning-In-Place).In addition, some applications make special demands onthe system in terms of safety or process technology.Certificates can be ordered on request for• WRC• FDA (rubber parts)• different material certificates, see page 16.Solutions<strong>Grundfos</strong> offers the following solutions to meet thesespecial requirements:• TriClamp connection• Cleaned and dried pumps• Electropolished pumps.TriClampA base with TriClamp connection is of a hygienic designwith a sanitary coupling for use in the pharmaceuticaland food industry.The gasket is made of PTFE or EPDM.Pump rangeThe base with TriClamp connection is available for thefollowing <strong>Grundfos</strong> pumps:Pump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90type<strong>CR</strong><strong>CR</strong>I • • • • • • •<strong>CR</strong>N • • • • • • •GR5841_baseReference numbersBase with TriClamp connectionPump typeReference number<strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3 and 5 98 96 92<strong>CR</strong>I, <strong>CR</strong>N 10 , 15 and 20 98 94 79GR5841_clampPart numbersTwo gaskets and two couplingsPump typePipeworkconnectionGasketpartsPartnumber<strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3 and 5 1 1/2" EPDM 96 51 53 74<strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3 and 5 1 1/2" PTFE 96 51 53 75<strong>CR</strong>I, <strong>CR</strong>N 10 , 15 and 20 2" EPDM 96 51 53 76<strong>CR</strong>I, <strong>CR</strong>N 10 , 15 and 20 2" PTFE 96 51 53 7728


Pumps<strong>Custom</strong>-built pumpsCleaned and dried pumpsPump rangeThe following <strong>Grundfos</strong> pumps are available as cleanedand dried pumps:Pumptype<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64<strong>CR</strong> • • • • • • • • • •<strong>CR</strong>I • • • • • • •<strong>CR</strong>N • • • • • • • • • •Also available for <strong>CR</strong>T 2, 4, 8, 16.Technical descriptionPrior to assembly, the pump components are washed inpure, hot soap water, rinsed in de-ionized water, anddried.Note: Cleaned and dried pumps are not performancetested in a test bed.The pumps are wrapped in a plastic bag before beingpacked.Reference numbersPump typeReference number<strong>CR</strong>I, <strong>CR</strong>N 1s, 1, 3, 5, 10, 15 and 20 98 98 70<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64, 90 98 96 41Electropolished pumpsGeneral informationTo substantially reduce the risk of corrosion of thematerials and improve the cleanability.Reference applicationsThe pharmaceutical-/food-/electronic industry.Pump rangeThe following <strong>Grundfos</strong> pumps are available as electropolishedpumps:Pump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong>20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90type<strong>CR</strong><strong>CR</strong>I<strong>CR</strong>N • • • • • • • • • • •Technical descriptionThe pump incorporates a standard shaft seal which hasnot been polished.Electro-polishing removes burrs as well as metallic andnon-metallic inclusions, providing an extremely smooth,clean and corrosion-resistant stainless steel surface.First all components are pickled in a mixture of nitricacid and hydrofluoric acid. Subsequently, the componentsare electropolished in a mixture of sulphuric acidand phosphoric acid. Finally, the components are passivatedin nitric acid.The <strong>CR</strong>N 1s, 1, 3, 5, 10, 15 and 20 cast parts are allmechanically polished before being electropolished.Pump type<strong>CR</strong>N 1s, 1, 3, 5, 10, 15 and 20<strong>CR</strong>N 32, 45, 64, 90Stainless steelcast partsStainless steelplate partsSurfaceroughness[µ in]• equal to or• below 32• 400-600equal to or•below 32DimensionsDimensions are identical to those of the standard pump.Reference numbersPump typeReference number<strong>CR</strong>N 1s, 1, 3, 5 98 97 60<strong>CR</strong>N 10, 15, 20 98 94 80<strong>CR</strong>N 32, 45, 64, 90 98 96 2529


Low-NPSH pumps<strong>Custom</strong>-built pumpsLow-NPSH pumpsSectional drawingGeneral informationThe low-NPSH pumps are designed for poor suctionconditions and/or high application temperatures.The pumps are specially suited for handling poor inletflows and liquid temperatures above 140°F.Reference applications• Boiler-feed applications• Applications involving a risk of poor inlet/suctionconditions• High-temperature applications.Pump rangeThe following <strong>Grundfos</strong> pumps are available as low-NPSH pumps:Pumptype<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90<strong>CR</strong> • • • • • • • •<strong>CR</strong>I • • • • •<strong>CR</strong>N • • • • • • • •Technical descriptionThe low-NPSH pump are standard pumps provided witha special, oversized inlet impeller and chamber. Thisreduces the NPSH value and prevents erosion anddestruction of pump, piping system and valves.The improved inlet design may expose the low-NPSHpump to a higher level of stress as compared to conventionalpumps, without affecting the stability of operation.Dimensions and weightsLow-NPSH pumps have the same dimensions andweights as standard <strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N pumps. This informationcan be found in the <strong>CR</strong>(E), <strong>CR</strong>I(E), <strong>CR</strong>N(E) ProductGuide.Special inletimpellerSpecial inletpartOperating rangeMax. pressureMax. liquid temperatureReference numbers362 psi248°F Max. ambient temperature 104°F Max. liquid temperature is 356°F combined with the Cool-Top.Pump typeReference number<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 3 98 96 76<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 5 98 96 84<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 10, 15, 20 98 94 81<strong>CR</strong>, <strong>CR</strong>N 32, 45, 64 98 97 64TM01 8865 120030


Performance curvesLow-NPSH pumps<strong>CR</strong> 3, <strong>CR</strong>I 3, <strong>CR</strong>N 3H[m]240220200H[ft]800750700650-25-21-23<strong>CR</strong> 3<strong>CR</strong>I 3<strong>CR</strong>N 32-pole, 60 HzH[ft]800750700650180600-19600160550500-17550500140450-154501201008060402040035030025020015010050-13-11-9-7-5-3-12-10-8-6-440035030025020015010050000 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]0P2[kW]0.100.050.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h]P2[hp]0.15P20.10Eff0.05Eff[%]6040200.00H[m]4200.0000 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]NPSHNPSH[ft][ft]15NPSHR151010Low NPSHR55000 2 4 6 8 10 12 14 16 18 20 22 24Q [US GPM]TM02 8378 5103Performance curves<strong>CR</strong> 331


Performance curvesLow-NPSH pumps<strong>CR</strong> 5, <strong>CR</strong>I 5, <strong>CR</strong>N 5H[m]240220200H[ft]800750700650-24-20-22<strong>CR</strong> 5<strong>CR</strong>I 5<strong>CR</strong>N 52-pole, 60 HzH[ft]800750700650180160140120600550500450400-16-14-12-18-15-136005505004504001008060350300250200-10-8-6-11-9-735030025020040150100-4-5150100205050000 5 10 15 20 25 30 35 40 45 Q [US GPM]0P2[kW]0.20.1P2[hp]0.30.20.10 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]P2EffEff[%]6040200.0H[m]420.000 5 10 15 20 25 30 35 40 45 Q [US GPM]NPSHNPSH[ft]NPSHR[ft]151510105Low NPSHR5000 5 10 15 20 25 30 35 40 45 Q [US GPM]0TM02 8379 5103<strong>CR</strong> 532


Performance curvesLow-NPSH pumps<strong>CR</strong> 10, <strong>CR</strong>I 10, <strong>CR</strong>N 10H[m]240220200H[ft]800750700650-17-16-14<strong>CR</strong> 10<strong>CR</strong>I 10<strong>CR</strong>N 102-pole, 60 HzH[ft]800750700650180160140120100806040600550500450400350300250200150100-12-10-9-8-7-6-5-4-3600550500450400350300250200150100205050000 5 10 15 20 25 30 35 40 45 50 55 60 Q [US GPM]0P2[kW]0.40.2P2[hp]0.80.60.40.20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Q [m³/h]P2EffEff[%]806040200.0H[m]420.000 5 10 15 20 25 30 35 40 45 50 55 60 Q [US GPM]NPSHNPSH[ft][ft]15NPSHR 1510105Low NPSHR5000 5 10 15 20 25 30 35 40 45 50 55 60 Q [US GPM]0TM02 8380 2004 <strong>CR</strong> 1033


Performance curvesLow-NPSH pumps<strong>CR</strong> 15, <strong>CR</strong>I 15, <strong>CR</strong>N 15H[m]240220H[ft]850800750700-12-10<strong>CR</strong> 15<strong>CR</strong>I 15<strong>CR</strong>N 152-pole, 60 HzH[ft]850800750700200180160650600550500-9-8-76506005505001401201008060402045040035030025020015010050-6-5-4-3-245040035030025020015010050000 10 20 30 40 50 60 70 80 90 100 110 Q [US GPM]0P2[kW]P2[hp]2.00 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]EffEff[%]801.00.51.51.00.5P26040200.0H[m]4200.000 10 20 30 40 50 60 70 80 90 100 110 Q [US GPM]NPSHNPSH[ft]NPSHR[ft]151510105Low NPSHR5000 10 20 30 40 50 60 70 80 90 100 110 Q [US GPM]TM02 8381 5103<strong>CR</strong> 1534


Performance curvesLow-NPSH pumps<strong>CR</strong> 20, <strong>CR</strong>I 20, <strong>CR</strong>N 20H[m]180160H[ft]600550500-8-7<strong>CR</strong> 20<strong>CR</strong>I 20<strong>CR</strong>N 202-pole, 60 HzH[ft]600550500140450-6450120100400350-5400350300-430080250-32506020020040150-2150100100205050000 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]0P2[kW]P2[hp]40 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 Q [m³/h]EffEff[%]8021321P26040200H[m]840000 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]NPSHNPSH[ft][ft]30NPSHR3020201010Low NPSHR000 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]TM02 8382 5103<strong>CR</strong> 2035


Performance curvesLow-NPSH pumps<strong>CR</strong> 32, <strong>CR</strong>N 32H[m]250H[ft]900800-9-10-2-9-2<strong>CR</strong> 32<strong>CR</strong>N 322-pole, 60 HzH[ft]900800700-8-8-2700200600-7-7-2600150100500400300-6-5-4-3-6-2-5-2-4-2-3-250040030050200-2-2-1200100100000 20 40 60 80 100 120 140 160 180 200 Q [US GPM]0P2[kW]21P2[hp]43210 5 10 15 20 25 30 35 40 45 Q [m³/h]EffP2 1/1P2 2/3Eff[%]806040200H[m]840000 20 40 60 80 100 120 140 160 180 200 Q [US GPM]NPSHNPSH[ft][ft]30NPSHR 3020Low NPSHR201010000 20 40 60 80 100 120 140 160 180 200 Q [US GPM]TM02 8383 5103<strong>CR</strong> 3236


Performance curvesLow-NPSH pumps<strong>CR</strong> 45, <strong>CR</strong>N 45H[m]250H[ft]900800-7-7-1-7-2<strong>CR</strong> 45<strong>CR</strong>N 452-pole, 60 HzH[ft]900800200700-6-6-1-6-2700600-5-5-1-5-2600150500-4-4-1-4-2500100400300-3-3-1-3-240030050200-2-2-1200100100000 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]0P2[kW]642P2[hp]86420 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]EffP2 1/1P2 2/3Eff[%]806040200H[m]840000 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]NPSHNPSH[ft][ft]303020NPSHR 201010Low NPSHR000 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]TM02 8384 5103<strong>CR</strong> 4537


Performance curvesLow-NPSH pumps<strong>CR</strong> 64, <strong>CR</strong>N 64H[m]180160H[ft]600550500-5-2-4-4-1<strong>CR</strong> 64<strong>CR</strong>N 642-pole, 60 HzH[ft]600550500140450-4-2-3450120400-3-1400100350-3-2350300-230080250-2-12506020020040150150100100205050000 40 80 120 160 200 240 280 320 360 400 440 Q [US GPM]0P2[kW]1284P2[hp]1612840 10 20 30 40 50 60 70 80 90 100 Q [m³/h]EffP2 1/1P2 2/3Eff[%]806040200H[m]8400H[ft]302010000 40 80 120 160 200 240 280 320 360 400 440 Q [US GPM]NPSH[ft]NPSHR 3020Low NPSHR1000 40 80 120 160 200 240 280 320 360 400 440 Q [US GPM]TM02 8385 5103<strong>CR</strong> 6438


4-pole versions<strong>Custom</strong>-built pumps<strong>CR</strong> pumps with 4-pole motorsTechnical descriptionCalculation of motor size:Use the P2 curve on the following curve sheets to calculatethe 4-pole motor size.The minimum motor size available for each pump type isshown in the table.Pump sizeMotor size[HP]<strong>CR</strong> 1 1/3<strong>CR</strong> 3 1/3<strong>CR</strong> 5 1/3<strong>CR</strong> 10 1/3<strong>CR</strong> 15 1/3<strong>CR</strong>20 1/3<strong>CR</strong> 32 3<strong>CR</strong> 45 3<strong>CR</strong> 64 3<strong>CR</strong> 90 3General information<strong>CR</strong> standard pumps fitted with 4-pole motors.Reference applications• Applications where a low sound pressure level isrequired• Applications with poor inlet conditions.Pump rangeThe following <strong>Grundfos</strong> pumps are available as 4-poleversions:GR5381Reference numbersPump type<strong>CR</strong>, <strong>CR</strong>I, <strong>CR</strong>N 1, 3, 5, 10, 15 and 20<strong>CR</strong>, <strong>CR</strong>N 32, 45 and 64Dimensions and weightsReference number99 97 24<strong>CR</strong> pumps with 4-pole motors will be shorter in heightand weigh less than standard <strong>Grundfos</strong> <strong>CR</strong> pumps. Thisis due to the smaller horsepower motors and motorstools required to power the pump at 4-pole performance.Pump<strong>CR</strong> 1s <strong>CR</strong> 1 <strong>CR</strong> 3 <strong>CR</strong> 5 <strong>CR</strong> 10 <strong>CR</strong> 15 <strong>CR</strong> 20 <strong>CR</strong> 32 <strong>CR</strong> 45 <strong>CR</strong> 64 <strong>CR</strong> 90type<strong>CR</strong> • • • • • • • • • •<strong>CR</strong>I • • • • • •<strong>CR</strong>N • • • • • • • • • •39


Performance curves4-pole versions<strong>CR</strong> 1, <strong>CR</strong>I 1, <strong>CR</strong>N 1H[m]6050H[ft]200180160-27-23-25-21<strong>CR</strong> 1<strong>CR</strong>I 1<strong>CR</strong>N 14-pole, 60 HzH[ft]20018016040140120-19-17140120-1530201010080604020-12-10-8-6-4-2-13-11-9-7-5-310080604020000.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [US GPM]0P2[kW]0.0100.0050.0 0.5 1.0 Q [m³/h]P2Eff[hp][%]0.0150.0100.005P2Eff6040200.000H[m]0.80.40.00.00000.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5NPSHQ [US GPM]NPSH[ft][ft]33221 NPSHR1000.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [US GPM]TM02 8386 5103Performance curves<strong>CR</strong> 140


Performance curves4-pole versions<strong>CR</strong> 3, <strong>CR</strong>I 3, <strong>CR</strong>N 3H[m]6050H[ft]200180160-25-21-23<strong>CR</strong> 3<strong>CR</strong>I 3<strong>CR</strong>N 34-pole, 60 HzH[ft]200180160-1940140-17140120-1512030201010080604020-13-11-9-7-5-3-12-10-8-6-4-210080604020000 1 2 3 4 5 6 7 8 9 10 11 Q [US GPM]0P2[kW]0.020.010.0 0.5 1.0 1.5 2.0 2.5 Q [m³/h]P2[hp]Eff0.03P20.020.01Eff[%]6040200.00H[m]0.80.40.0000 1 2 3 4 5 6 7 8 9 10 11 Q [US GPM]NPSHNPSH[ft][ft]3322NPSHR110.000 1 2 3 4 5 6 7 8 9 10 11 Q [US GPM]0TM02 8387 5103<strong>CR</strong> 341


Performance curves4-pole versions<strong>CR</strong> 5, <strong>CR</strong>I 5, <strong>CR</strong>N 5H[m]6050H[ft]200180160-24-20-22<strong>CR</strong> 5<strong>CR</strong>I 5<strong>CR</strong>N 54-pole, 60 HzH[ft]200180160140-1814040-16120-14-1512030100-12-13100201080604020-10-8-6-4-2-11-9-7-5-380604020000 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]0P2[kW]0.020.010.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Q [m³/h]P2[hp]0.04P20.030.020.01EffEff[%]806040200.00H[m]1.20.80.40.00.000 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]NPSHNPSH[ft][ft]443210NPSHR0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]03210TM02 8388 5103<strong>CR</strong> 542


Performance curves4-pole versions<strong>CR</strong> 10, <strong>CR</strong>I 10, <strong>CR</strong>N 10H[m]6050H[ft]220200180160-17-16-14<strong>CR</strong> 10<strong>CR</strong>I 10<strong>CR</strong>N 104-pole, 60 HzH[ft]220200180160-1240140120-10-914012030100-810080-7-6802060-5-460104020-3-2-14020000 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Q [US GPM]0P2[kW]0.080.040.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 Q [m³/h]P2[hp]0.12EffP20.080.04Eff[%]6040200.00H[m]0.0000 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Q [US GPM]NPSHNPSH[ft][ft]66144020NPSHR0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Q [US GPM]20TM02 8389 5103<strong>CR</strong> 1043


Performance curves4-pole versions<strong>CR</strong> 15, <strong>CR</strong>I 15, <strong>CR</strong>N 15H[m]6050H[ft]200180160-12-10-9<strong>CR</strong> 15<strong>CR</strong>I 15<strong>CR</strong>N 154-pole, 60 HzH[ft]20018016040140-8140120-712030100-610080-5802060-4-3601040-24020-120000 5 10 15 20 25 30 35 40 45 50 55 Q [US GPM]0P2[kW]0.20.1P2[hp]0.30.20.10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Q [m³/h]EffP2Eff[%]6040200.0H[m]0.40.20.00.000 5 10 15 20 25 30 35 40 45 50 55 Q [US GPM]NPSHNPSH[ft][ft]1.51.51.01.0NPSHR0.50.50.00.00 5 10 15 20 25 30 35 40 45 50 55 Q [US GPM]TM02 8390 5103<strong>CR</strong> 1544


Performance curves4-pole versions<strong>CR</strong> 20, <strong>CR</strong>I 20, <strong>CR</strong>N 20H[m]50H[ft]180160-10<strong>CR</strong> 20<strong>CR</strong>I 20<strong>CR</strong>N 204-pole, 60 HzH[ft]180160140-814040120-712030100-6100-580802060-4-3601040-24020-120000 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q [US GPM]0P2[kW]0.20.1P2[hp]0.30.20.10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Q [m³/h]EffP2Eff[%]6040200.0H[m]20.00 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q [US GPM]NPSHNPSH[ft][ft]8860610420NPSHR0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q [US GPM]420TM02 8391 5103<strong>CR</strong> 2045


Performance curves4-pole versions<strong>CR</strong> 32, <strong>CR</strong>N 32H[m]60H[ft]220200-9-10-2-9-2<strong>CR</strong> 32<strong>CR</strong>N 324-pole, 60 HzH[ft]220200180-8-8-218050160-7-7-216040140-6-6-2140120-51203010080-4-5-2-4-2100802060-3-3-260104020-2-1-2-1-1-1-2-24020000 10 20 30 40 50 60 70 80 90 100 Q [US GPM]0P2[kW]0.40.2P2[hp]0.80.60.40.20 2 4 6 8 10 12 14 16 18 20 22 24 Q [m³/h]EffP2 1/1P2 2/3Eff[%]806040200.0H[m]20.00 10 20 30 40 50 60 70 80 90 100 Q [US GPM]NPSHNPSH[ft][ft]8NPSHR 8606104200 10 20 30 40 50 60 70 80 90 100 Q [US GPM]420TM02 8392 5103<strong>CR</strong> 3246


Performance curves4-pole versions<strong>CR</strong> 45, <strong>CR</strong>N 45H[m]60H[ft]220200-7-7-2<strong>CR</strong> 45<strong>CR</strong>N 454-pole, 60 HzH[ft]22020050180160-6-5-6-218016040140120-4-5-2140120-4-230100-310080-3-2802060-260-2-2104020-1-1-14020000 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]0P2[kW]0.80.4P2[hp]1.61.20.80.40 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 Q [m³/h]EffP2 1/1P2 2/3Eff[%]806040200.0H[m]0.000 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]NPSHNPSH[ft][ft]66144020NPSHR0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]20TM02 8393 5103<strong>CR</strong> 4547


Performance curves4-pole versions<strong>CR</strong> 64, <strong>CR</strong>N 64H[m]4844H[ft]160150140-4-5-2<strong>CR</strong> 64<strong>CR</strong>N 644-pole, 60 HzH[ft]16015014040130-4-113036120-4-2120322811010090-3-3-1110100902480-3-280207060-2-2-170601650-2-2501240-14083020-1-1302041010000 20 40 60 80 100 120 140 160 180 200 220 Q [US GPM]0P2[kW]1.00.5P2[hp]2.01.51.00.50 5 10 15 20 25 30 35 40 45 50 Q [m³/h]EffP2 1/1P2 2/3Eff[%]806040200.0H[m]20.00 20 40 60 80 100 120 140 160 180 200 220 Q [US GPM]NPSHNPSH[ft][ft]886NPSHR60104200 20 40 60 80 100 120 140 160 180 200 220 Q [US GPM]420TM02 8394 5103<strong>CR</strong> 6448


Performance curves4-pole versions<strong>CR</strong> 90, <strong>CR</strong>N 90H[m]40H[ft]140130-4-2<strong>CR</strong> 90<strong>CR</strong>N 904-pole, 60 HzH[ft]14013036120-3120322811010090-3-1-3-2110100902480-2802016706050-2-1-2-27060501240-140830-1-130202041010000 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]0P2[kW]210H[m]2P2[hp]432100 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]P2 1/1P2 2/30 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]NPSHNPSH[ft][ft]8NPSHR86EffEff[%]8060402006104200 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]420TM02 8395 5103<strong>CR</strong> 9049


Being responsible is our foundationThinking ahead makes it possibleInnovation is the essenceL-<strong>CR</strong>-PG-002 02/05Repl. L-<strong>CR</strong>-PG-002 2/04USSubject to alterations<strong>Grundfos</strong> Pumps Corporation17100 W. 118th TerraceOlathe, KS 66061Telephone 913 227 3400Fax: 913 227 3500www.grundfos.com<strong>Grundfos</strong> Canada, Inc.2941 Brighton RoadOakville, Ontario L6H 6C9 CanadaTelephone: 905 829 9533Fax: 905 829 9512Bombas <strong>Grundfos</strong> de Mexico, S.A. de C.V.Boulevard TLC #15Parque Stiva AeropuertoApodaca, N.L. 66600 MexicoTelephone: 52 81 8144 4000Fax: 52 81 8144 4010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!