12.07.2015 Views

Beta-Attenuation Mass Monitor BAM 1020 - Met One Instruments

Beta-Attenuation Mass Monitor BAM 1020 - Met One Instruments

Beta-Attenuation Mass Monitor BAM 1020 - Met One Instruments

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

determine, with exceptionalaccuracy, the particulate concentration.The mass density is measuredusing the technique of betaattenuation. A small 14 C betasource (60 μCi) is coupled to asensitive detector that countsthe emitted beta particles.The filter tape is placed betweenthe beta source and thedetector. As the mass depositedon the filter tape increases,the measured beta particlecount is reduced according to aknown equation.Design & ConstructionThe Filter Tape Transport Systemis based upon a designthat has been used for overtwo decades in Japan. Thetransport reflects the qualityand precision of superior design.Responding to the requirementsof current data validationrequirements, an improvedelectronic measurementsystem was developedusing the microprocessor controllerand data logger. All operationsof the unit are displayedwith the 8 line by 40character display.An RS-232 serial interface isused for data transfer and instrumentoperations status.This interface is often usedwith modem for remote communications.A second output-only port maybe used with a printer or computer.Output may be set fordata printout or one of two diagnosticmodes.Analog voltage or current outputsof concentration valueswith special error coding andcontact closures for error conditionsare included.Data ValidationThe <strong>BAM</strong>-<strong>1020</strong> is alwaysevaluating its operation to ensurehighest confidence andthe highest quality data recoveryof any unit of its type. Theuser may select various criteriafor data validation, includingflow statistics, power failures,and error codes. An error log ismaintained with the date, hourand type of error. These dataare available during routinedata recovery.For the benefit of users notusing the serial port, the analogoutput informs the user thatthe <strong>BAM</strong>-<strong>1020</strong> has a questionabout data or operation. Theoperator may then use the optionalmodem connection toverify diagnostics or a computerto interrogate the errorlog during the next site visit.Span CheckReliable, accurate measurementsare assured with theautomatic span check conductedeach cycle. Should theinstrument fail to perform tospecification an error is loggedin memory and data is flagged.Span measurements are madeby an automatic insertion of areference membrane in themeasurement path each hour.SpecificationsRange: 0-.1, .2, .25, .5, 1, 2,5, 10 mg/m 3Cycle:1 hourDetection Limit: 1 μg/m 3 on 24 hrs5 μg/m 3 on 1 hourResolution: ±1 μg/m 3Accuracy:<strong>Beta</strong> Source:Filter Tape:Flow Rate:Data Storage:Power:TemperatureRange:Dimensions:(mm)±8% of indication for1 hour mode, ±2%compared to FRM for24 hour mode14C, 60 μCiContinuous GlassFiber Type0-20 SLM useradjustable200 days(1 hour sample)100-230 VAC,50/60 Hz-30°C to +60°C(0-90% RH, Noncondensing)310(H)x430(W)x400(D)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!