• instantaneous switching 0• lagging switching 0Number of NO contacts / for auxiliary contacts• instantaneous switching 1• leading switching 0Operating current / of the auxiliary contacts• at AC-12 / maximum A 10• at AC-15• at 230 V A 10• at 400 V A 3• at DC-12• at 48 V A 6• at 60 V A 6• at 110 V A 3• at 220 V A 1• at DC-13• at 24 V A 6• at 48 V A 2• at 60 V A 2• at 110 V A 1• at 220 V A 0.3Short-circuit:Design of the fuse link• for short-circuit protection of the auxiliary switch / requiredfuse gL/gG: 10 A• for short-circuit protection of the main circuit• with type of assignment 1 / required gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 35A• at type of coordination 2 / requiredgL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE:20AInstallation/mounting/dimensions:Built in orientationType of mountingType of fixing/fixation / series installationverticalscrew and snap-on mounting onto 35 mm standardmounting rail according to DIN EN 50022YesWidth mm 45Height mm 57.5Depth mm 73Distance, to be maintained, to the ranks assembly• forwards mm 0• backwards mm 0<strong>3RT2017</strong>-<strong>1AP01</strong>Page 4/ 704/27/2011subject to modifications© Copyright Siemens AG 2011