12.07.2015 Views

OCA 15plus - Neurtek

OCA 15plus - Neurtek

OCA 15plus - Neurtek

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

O C A 1 5 p l u sV i d e o - b a s e d o p t i c a l c o n t a c ta n g l e m e a s u r i n g i n s t r u m e n tNEURTEK S.A. Políg.Ind.Azitain, Parcela 3 A Apdo.399 20600 EIBAR SPAIN 902 42 00 82 FAX 943 82 01 57Emails: comercial@neurtek.es sat@neurtek.eswww.neurtek.com


<strong>OCA</strong> 15 LHT with high temperature furnace MTFQ 1200Features of the <strong>OCA</strong> <strong>15plus</strong>Whether your application demands theevaluation of contact angle or drop shape,the video-based optical contact anglemeasuring system, <strong>OCA</strong> <strong>15plus</strong>, may be theinstrument of choice where initial budgetsare limited. It is designed for applicationsthat can be comfortably addressed witha single electronic syringe unit, ES, and donot demand automated measurement ortemperature and atmosphere control fortheir samples. The <strong>OCA</strong> <strong>15plus</strong> is availablein the variants: <strong>OCA</strong> 15Lplus, <strong>OCA</strong> 15XL,<strong>OCA</strong> 15LHT, and <strong>OCA</strong> 15LHT‐SV. Furthermorethe <strong>OCA</strong> <strong>15plus</strong> is easily upgradableto an <strong>OCA</strong> 20 (also <strong>OCA</strong> 15L to an <strong>OCA</strong> 20Land <strong>OCA</strong> 15LHT to an <strong>OCA</strong> 20LHT) or to an<strong>OCA</strong> 30 (also <strong>OCA</strong> 15L to an <strong>OCA</strong> 30L).Components and accessories• sample table with manual adjustment inthree axis via high-precision mechanicsfor an accurate sample positioning• high performance 6x parfocal zoomlens with integrated continuous finefocus, and adjustable observation andcamera tilt angle• video measuring system with USBcamera (52 images/s sample rate), easilyupgradable with the high-speedoption UpUSB52H (max. 146 images/ssample rate) or the high-speed videosystem Up<strong>OCA</strong>H (max. 1000 images/ssample rate)Thermal chamber TPC 150 with controller TC 150<strong>OCA</strong> <strong>15plus</strong> with single direct dosing system SD-DM andelectronic syringe unit ES• lighting with continuous adjustableintensity without hysteresis• manual multiple dosing system MD/4,• single dosing system SD• single direct dosing system SD-DMfor use with standard and disposablesyringes and needles• one electronic syringe unit ES, softwarecontrolled dosing volume (min. 50 nl)and dosing rate (0.06 µl/s…26.4 µl/s)software controlled adjustable• up to four manual syringe units MS• manual tilting assembly TBA 60M(max. tilting angle 60°)• temperature and environmental controlsystems (‐30…1800 °C and from1 mPa…5·10 6 Pa)• wide range of sample holding and positioningunits like holders for foils orpapers FSH 30 and FSC 80/150, for singlefibers and hairs FHO 40 plus, or thesuction plate SP 100 for holding thinflexible samples flat on the stage withan adjustable suction area• electro wetting platform EWP 100 forthe analysis of sessile and pendant dropsunder a well definable electrical field• top view video system TV-VS for thequalitative documentation of the dropposition (USB camera with 52 images/ssample rate, 6x parfocal zoom lens andadjustable observation angle)Software for efficient workDataPhysics is specialised in the developmentof high-precise and reliablemethods for evaluating drop contoursin combination with statistical erroranalysis. The SCA software assists you inthe intuitive use of the video-based opticalcontact angle measuring instrument<strong>OCA</strong> <strong>15plus</strong> by specifying measurementprocedures and in collecting, assessing,and evaluating the measured data. TheSCA software is designed as a modularprogram for all <strong>OCA</strong> instruments. UnderWindows 7® and Windows Vista® itworks in 32- and also in 64-bit mode;NEURTEK S.A. Políg.Ind.Azitain, Parcela 3 A Apdo.399 20600 EIBAR SPAIN 902 42 00 82 FAX 943 82 01 57www.neurtek.comunder Windows XP® /SP3 only in 32-bitmode.The available software modules for the<strong>OCA</strong> <strong>15plus</strong> models are:SCA 20 — contact angle• video based measurement and presentationof the static and dynamic contactangle on plane, convex, and concavesurfaces• automatic measurement of the contactangle hysteresis• record/store of image sequences• statistics and measurement erroranalysis• Liquids and solids database with currentlymore than 170 records for all surfaceenergy analysis methods includingrelated citationsSCA 21 — surface free energy• analysis of the surface free energy ofsolids as well as their components (e.g.dispersive, polar and hydrogen bondparts, acid and base portions) accordingto nine different theoriesManual tilting base assembly TBA 60M• representation of wetting envelopesand work of adhesion/contact anglediagramsSCA 22 — pendant drop• analysis of the surface and interfacialtension, as well as their polar and dispersivecontributions, based on the analysisof the drop shape of pendant dropsSCA 23 — lamella contour• analysis of the surface and interfacialtension based on the evaluation of thelamella contourSCA 20 and SCA 21 – measuring and evaluating the wettingproperties of solidsMolten glass drop on aceramics substrate


Te c h n i c a l d a t aMax. sample dimensions (L x W x H):Sample table dimensions:Traversing range of sample table:Max. sample weight:Measuring range for contact angles:Measuring range for surface andinterfacial tensions:Optics:Video system:Measuring techniques:Software SCA 20:• 220 x ² x 70 mm• 330 x ² x 70 mm (<strong>OCA</strong> 15L)• 410 x ² x 70 mm (<strong>OCA</strong> 15XL)• HTFQ 1200 or HTFC 1500 (330 x ² x 70 mm) (<strong>OCA</strong> 15LHT)• HTFC 1500HV (1400 x ² x 210 mm) (<strong>OCA</strong> 15LHT-SV). 100 x 100 mm• 100 x 100 x 50 mm (in X-/Y-/Z-direction)• 210 x 150 x 50 mm (in X-/Y-/Z-direction) (<strong>OCA</strong> 15L)• 410 x 150 x 50 mm (in X-/Y-/Z-direction) (<strong>OCA</strong> 15XL)• 210 x 100 x 50 mm (in X-/Y-/Z-direction) (<strong>OCA</strong> 15LHT)• 15.0 kg• 0…180 °; ± 0.1 ° measuring precision of the video system• 1·10 -2 ...2·10 3 mN/m resolution: ± 0.01 mN/m• 6-fold zoom lens (0.7 … 4.5 magnification) with integrated fine focus (± 6 mm)• Lighting with software controlled adjustable intensity without hysteresis• USB-CCIR camera, max. resolution 768 x 576 pixel, max. sample rate 52 images/s,field of view 1,32 x 0,99…8,50 x 6,38 mm• Image distortion < 0.05%• Sessile and captive drop method, tilting table/base method• Pendant drop method• Lamella method on test spheres and rods• Video based measurement of static and dynamic contact angles according to the sessile and captivedrop as well as tilting table / base methods, measurement of drop and lamella contours.• Operation of one ES electronic syringe unit• Control of high temperature furnaces HTFxx via USB directly from PCSoftware SCA 21:Software SCA 22:Software SCA 23:Dimensions (L x W x H):Weight:Power supply:For more information ab out a tailor made solutionto your sur face chemistr y requirements,please contac t us.We will b e pleased to provide a quotation,obligation free, for your instrument system.DataPhysics Instruments GmbH • Raiffeisenstraße 34 • D-70794 Filderstadtfon ++49 (0)711 770556-0 • fax ++49 (0)711 770556-99info@dataphysics.de • www.dataphysics.de• Calculation of surface free energies on solids and their contributions with error limits based on measuredcontact angles, evaluation according to Fowkes (geometric mean), Wu (harmonic mean), extended Fowkes(including H bonds), Zisman (critical surface tension), Owens-Wendt (dispersive and polar), van Oss andGood (acid-base theory), Schultz I + II (two-liquid method), Neumann’s Equation of State (EOS), calculationof dispersive and polar contributions of liquids based on measured surface and interfacial tensions as wellas contact angles with error limits, calculation of wetting envelopes, work of adhesion, and other diagrams• Calculation of surface and interfacial tensions based on pendant drop contours and rising bubbles• Calculation of surface tensions of liquids based on liquid lamellae on test spheres and rods• 590 x 220 x 550 mm• 700 x 280 x 550 mm (<strong>OCA</strong> 15L)• 960 x 280 x 550 mm (<strong>OCA</strong> 15XL)• 700 x 280 x 620 mm (<strong>OCA</strong> 15LHT)• 16 kg• 20 kg (<strong>OCA</strong> 15L)• 22 kg (<strong>OCA</strong> 15XL)• 21 kg (<strong>OCA</strong> 15LHT)• 100…240VAC; 50…60 Hz; 55 WThe contact angle measuring instruments from the <strong>OCA</strong> series share a common feature – the successful <strong>OCA</strong> accessories range,designed to help solving your interfacial problem. This extensive range of accessories consists of various dosing systems, temperatureand environment control systems, turn and tilting tables, sample positioning systems, and tilting base units.Your sales par tner:Phone ++34 (0)943 82 00 82Email comercial@neurtek.eswww.neurtek.comTechnical information in this document is subject to change without prior notice. Errors and omissions excepted.© Copyright by DataPhysics Instruments GmbH, Filderstadt. is a registered trademark of DataPhysics Instruments GmbH DS/<strong>OCA</strong> <strong>15plus</strong>-1004-1.6/EPhotos by Thomas Müller, Bavaria, Tony Stone, Stahl-Zentrum, Norbert Heil, DataPhysics archives. Text and layout: Gerhard Maier

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!