12.07.2015 Views

Invacare PT2000 Powered Wheelchair

Invacare PT2000 Powered Wheelchair

Invacare PT2000 Powered Wheelchair

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SAFETY INSPECTION/TROUBLESHOOTINGTROUBLESHOOTING – MECHANICALCHAIR VEERSLEFT/RIGHTSLUGGISH TURN/PERFORMANCECASTERSFLUTTERSQUEAKS &RATTLESLOOSENESS INCHAIRCHAIR 3WHEELSX X X XX X X X XXXSOLUTIONSIf pneumatic, checktires for correct andequal pressure.Check for loosestem nuts/bolts.Check that bothcasters contact theground at the sametime.TROUBLESHOOTING – ELECTRICALSYMPTOM PROBABLE CAUSE SOLUTIONSBatteries draw excessive currentwhen charging.Battery failure.Check batteries for shorted cell. Replace ifnecessary.Battery indicator flashes thecharge level is low – immediatelyafter recharge.Electrical malfunction.Battery failureMalfunctioning battery charger.Contact Dealer/<strong>Invacare</strong> for Service.Check batteries for shorted cell. Replace ifnecessary.Contact Dealer/<strong>Invacare</strong> for ServiceBattery indicator flashes thecharge level is low – too soonafter being recharged.Electrical malfunction.Batteries not charged.Weak batteries.Poor connections between charger andwheelchair. Contact Dealer/<strong>Invacare</strong> forService.Have charger checked.Replace batteries if necessaryMotor “chatters” or runsirregular.<strong>Wheelchair</strong> does not respond tocommands. Power “ON”, batteryindicator flashes.Only one (1) drive wheel turns.Electrical malfunction.Electrical Malfunction.One (1) or both clutchesdisengaged.Electrical malfunction.Contact Dealer/<strong>Invacare</strong> for Service.Contact Dealer/<strong>Invacare</strong> for Service.Engage motor locks/clutches.Contact Dealer/<strong>Invacare</strong> for Service.One (1) clutch is disengaged. Engage clutch.Joystick erratic or does not Electrical malfunction.Contact Dealer/<strong>Invacare</strong> for Service.respond as desired.Controller programmedReprogram controller (Contactimproperly.Dealer/<strong>Invacare</strong> for Service).<strong>Wheelchair</strong> does not respond to Poor battery terminal connection. Clean terminals.commands. Power indicatorOFF- even after recharging. Electrical malfunction.Contact Dealer/<strong>Invacare</strong> for Service.NOTE: For additional troubleshooting information and explanation of error codes, refer to pages 13 & 14of this manual.29

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!