12.07.2015 Views

TR100;V130 therm mix valve - Hunt Heating

TR100;V130 therm mix valve - Hunt Heating

TR100;V130 therm mix valve - Hunt Heating

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Heating</strong> – Hydronic Radiant Floor <strong>Heating</strong> Controls.T100R; V135 Thermostatic Mixing or Diverting ValvesAllow automatic temperature control in hotwater systems for in-floor radiant and otherheating units with standard capacityrequirements to provide increased comfort.T100R Specifications:Attachment Ring Thread : M30 x 1.5Adjustment Ranges (two models) :10 to 50°C [50 to 122°F]30 to 70°C [86 to 158°F]Capillary length : 2 metersV135 Specifications:Maximum Temperature Rating: 120°C [248°F]Maximum System Pressure: 232 psi.Maximum Differential Pressure: 147 psi.Stroke length: 0.08" [2 mm]Sizes available and Connections3/4" - Sweat union.1" - Sweat union.1-1/4" - NPT threaded union.• Continually monitor and adjust water temperature forconsistent comfort and relief from underheating and overheating.• Controls include set point dial, <strong>valve</strong> actuator, and remotesensor with capillary tube for surface mount on piping.• Self-powered control requires no electrical connections.• Two controls to provide two different temperature rangerequirements.• Plastic handle with captive adjustment cover providesmanual control of the <strong>valve</strong>.• Valve packing, which is made of resilient material (EPDM),ensures tight seal-off against close-off and working pressure.• Spring-loaded <strong>valve</strong> cone, which is made of high qualityengineered plastic material, ensures tight shutoff on hotwater systems.• Bronze casted body with all working parts in cartridge insertfor ease of service.• Port A closes on temperature rise.FLOW CAPACITIESSize (in.)Cv Factor3/43.715.81-1/45.81-1/211.7Cv = U.S.GPM at 1 psi differential pressure.Capacity RatingsFLOW RATE (USGPM)DIFFERENTIAL PRESSURE (PSI)34


Hydronic Radiant Floor <strong>Heating</strong> ControlsT100R; V135cont’dT100R dimensions in inches [mm]T100RThermostatic control with integral set point <strong>valve</strong> actuatorunit and remote, strap on type sensor which is connected bya capillary tube. It is normally used with the V135 hydroniccontrol <strong>valve</strong> for <strong>mix</strong>ing or diverting application, or with theV100E or V100D <strong>valve</strong>s for 2 way flow application.Available in 10-50C and 30-7-C temperature ranges.V1353 way <strong>mix</strong>ing or diverting <strong>valve</strong> suited for in-floor radianthydronic heating systems. It is normally used with the selfpowered type T100R <strong>therm</strong>ostatic control.V135 Valve nominal dimensions in in. [mm]SIZE(INCHES)L H MAX. hNPT Threaded Union3/411-1/41-1/25.556.307.10[140][159][180]3.25 [82]3.25 [82]3.25 [82]2.80 [70]3.15 [80]3.75 [95]Sweat Union3/411-1/41-1/25.105.856.40[128][148][162]3.25 [82]3.25 [82]3.25 [82]2.55 [64]2.95 [74]3.40 [86]35

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!