CPCB Zonal Office, BangaloreVRV BOQSl.no. Description Unit Qty Rate Amountb 2 C X 1.5 sqmm, as per relevant IS RMT 350c 2 C X 1.0 sqmm as per relevant IS RMT 3505 All civil works pertaining to Air-conditioning like breaking,making, painting of walls, glass etc. as required as persite conditions.Lot 1Note 1: Catalogues of all equipments shall be enclosedwith Compressor rating charts.Note 2: Incoming Power supply near indoor unit will beprovided by o<strong>the</strong>r agencies.Note 3: Taxes to be included in <strong>the</strong> price of equipments/accessories...SUB TOTAL FOR ANCILLARY WORKSTOTAL <strong>for</strong> VRF Systems3 of 9 KHANDEKAR ASSOCIATES


CPCB Zonal Office, BangaloreAHU COLD ROOMSl.no. Description Unit Qty Rate AmountEQUIPMENTFLOOR STANDING AIR COOLED SPLIT AIRCONDITIONERS1 supply of <strong>the</strong> Floor standing Air ConditionerSupply of <strong>the</strong> Floor standing Air ConditioningEquipments of <strong>the</strong> following capacity complete with <strong>the</strong>rotory compressor, condensor, evaporator completewith <strong>the</strong> all <strong>the</strong> controls .a 2.0 TR Nos. 2b 3.0 TR Nos. 2PART ABILL OF QUANTITIES (BOQ) FOR MISCELLANEOUS & COLD ROOMInstallation testing and commissioning of Floor2 standing UnitsThe necessary pedestals MS stand <strong>for</strong> supporting <strong>the</strong>condensers shall be included.5 Rm of refrigerant pipingper circuit shall be included.Local isolators to beincluded <strong>for</strong> outdoor units. Nitrile rubber tubing shall beused <strong>for</strong> insulation. The price should also includecabling between indoor and outdoor.a 2.0 TR Nos. 2b 3.0 TR Nos. 234Soft drawn Copper refrigerant piping with necessaryfittings of <strong>the</strong> following sizes.1/2" Rmt 503/8" Rmt 501/4" Rmt QROInsulation <strong>for</strong> Copper refrigerant piping using nitrilerubber tubings <strong>for</strong> <strong>the</strong> following pipe sizes.1/2" Rmt 503/8" Rmt 501/4" Rmt QRO5Drain piping using water quality blue HDPE pipe with GIfittingsi 40 mm dia Rmt QROii 32 mm dia Rmt QROiii 25 mm dia Rmt 25IICOLD ROOMSupply, installation, testing and commissioning of <strong>the</strong>1.25 TR Refrigeration Equipment complete with <strong>the</strong>rotory compressor, condensor, evaporator and copperrefrigerant piping complete with <strong>the</strong> all <strong>the</strong> controls asper <strong>the</strong> approved shop drawings / specifications.4 of 9 KHANDEKAR ASSOCIATES


CPCB Zonal Office, BangaloreAHU COLD ROOMSl.no. Description Unit Qty Rate AmountaThe scope of work also includes <strong>the</strong> setting up of <strong>the</strong>insulated sandwiched panels of self extinguishing qualityEPS as <strong>the</strong> core, sandwiched between 2 layers of 0.5mm thick pre-coated steel. <strong>the</strong> panels should bemanufactured to a width of 1.18 M, <strong>for</strong> <strong>the</strong> entire coldroom including <strong>the</strong> ceiling and <strong>the</strong> floor. The door of size7ft X 3 ft with <strong>the</strong> automatic door closer which is againinsulated shall be in <strong>the</strong> scope of AC contractor.Lot 1IIIDEHUMIDIFIERSupply, installation, testing and commissioningDesiccant Dehumidifier which shall be able to installabove <strong>the</strong> false ceiling and of non toxic, non flammablewith maximum moisture removal capacity to keep <strong>the</strong>specified room volume of 700 cu..ft, to maintain acondition of 40 ± 5 % RH @ 72 ± 5 ºF by a process airflow of 100 cfm as per specifications.NosQROIV All civil works pertaining to Air-conditioning likebreaking, making, painting of walls, glass etc. asrequired as per site conditions.Lot 1Note 1: Catalogues of all equipments shall be enclosedwith Compressor rating charts.Note 2: Incoming Power supply near indoor unit will beprovided by o<strong>the</strong>r agencies.Note 3: Taxes to be included in <strong>the</strong> price of equipments/accessories...SUB TOTAL FOR ANCILLARY WORKSTOTAL CONTRACT VALUE5 of 9 KHANDEKAR ASSOCIATES


CPCB Zonal office, BangaloreExhaust Systems BOQBILL OF QUANTITIES (BOQ) FOR EXHAUST SYSTEMSl.no. Description Unit Qty Rate AmountPART A EQUIPMENT1 Floor mounted Exhaust BlowerSupply, installation testing & commissioning of Ceilingsuspended Double skin Centrifugal DIDW ExhaustBlower complete with mounting arrangement & vibrationisolators - <strong>for</strong> second floor lab area.a 4500 cfm with 75mm static Nos 1Ceiling Mounted Duct in line Fresh Air FanSupply, installation testing & commissioning of Ceilingsuspended Fresh Air Blower .a 1000 cfm Nos 12 Ceiling Mounted Duct in line Exhaust Fana 2500 cfm with 25mm static Nos 1b 300 cfm with 25mm static Nos 7Floor mounted duct in line 250 cfm with 20mm staticAxial flow fan complete with <strong>the</strong> filter section and <strong>the</strong>entire fan assembly housed in a double skinNos 1c accoustically treated unit.d 200 cfm with 20mm static Nos 13 Wall / Window mounted Exhaust fana 500cfm Nos 2b 250 cfm Nos 1SUB TOTAL FOR EQUIPMENTPART B ANCILLARY WORKS1 DUCTING WORKSSupply, installation, testing & commissioning of GSSDucting with angle flanges & Hitec supports. The entireduct shall be fabricated with MS angle flanges. Slip1A joints are not acceptable.a 24 G SQM 100b 22 G SQM 60c 20 G SQM ROd 18 G SQM ROSupply, installation, testing & commissioning ofAluminium factory fabricated eliptical ducts of 22 Gsheets with angle flanges & Hitec supports, painted withzinc chromate primer and 2 coats of approved colourwith fittings as follows.a 24 G SQM ROb 22 G SQM 75c 20 G SQM ROd 18 G SQM RO6 of 9 KHANDEKAR ASSOCIATES


CPCB Zonal office, BangaloreExhaust Systems BOQSl.no. Description Unit Qty Rate Amount2 ACCOUSTIC INSULATIONbAHU Room accoustic insulation of walls and ceiling with48kg/m resin bonded fibre glass wool with 50mmthickness covered with GI frame (grid 600 x 600mm)and covered with 22G GI per<strong>for</strong>ated sheet.SQM 754 FLEXIBLE CONNECTIONFlexible connection (non canvas type) Nos 25 SUPPLY AIR DIFFUSERS (SAD)Supply & installation of Aluminium Powder coatedsupply air diffuser with OBD outer size 375 x 375 andneck size 225 x 2256 GRILLSSupply & installation of aluminium powder coated FreshAir & Exhaust air Grills7 VOLUME CONTROL DAMPERS (VCD)Supply & installation of GI Volume Control Damperswith matching flangesNos 20SQM 1SQM 18 COLLAR DAMPERAluminium Opoosed Blade Collar dampers SQM 19 FLEXIBLE HOOD CONNECTION ARRANGEMENTThe elephant trunk type flexible pipe connection suitableof connecting to <strong>the</strong> exhaust duct as per <strong>the</strong> tenderdrawing specification to be approved byclient/consultant made of PVC/Aluminium with <strong>the</strong>i flexible duct complete with canopy type inlet terminalThe Robo arm type flexible pipe suitable of connectingto <strong>the</strong> central exhaust duct as per <strong>the</strong> tender drawingii specification.10 FIXED FUME HOOD CONNECTIONSThe fixed fume hood connections to be made to <strong>the</strong>specific equipments. The connection shall be of G.I./aluminium directly with <strong>the</strong> exhaust duct. The controlshall be provided with <strong>the</strong> damper.Nos. 6Nos. 3Nos. 411 ELECTRICAL CABLINGElectrical Work: (PVC armoured al./cu cables)a 4 C x 16 Sq.mm (cu) RM ROb 4 C x 10 Sq.mm (cu) RM ROc 4 C x 6 Sq.mm (cu) RM 20d 3 C x 4 Sq.mm (cu) RM 80e 3 C x 2.5 Sq.mm (cu) RM 20f 10 C x 1.5 Sq.mm (cu) RM ROg 4 C x 1.5 Sq.mm (cu.) RM ROh 8 SWG GI wire earthing RM 120i End termination Lot 112 FILTERS7 of 9 KHANDEKAR ASSOCIATES


CPCB Zonal office, BangaloreExhaust Systems BOQSl.no. Description Unit Qty Rate AmountThe filters to be arranged in <strong>the</strong> plenum of <strong>the</strong> exhausti HEPA FilteriiHEPA Filter of following size arranged with 0.3 Micronfilteration and efficency upto 99.97% suitable <strong>for</strong> 4500CFM and 250 CFM fans. The size and <strong>the</strong> no. of filtersto be as per <strong>the</strong> manufacturer's standards.300 mm thick Lot 1Activated Carbon FiltersActivated Carbon Filters with high density carbon filled,fibrous adsorption medis that adsorbs and controlsairborne gases, VOCs( volatile organic compounds)100 mm thick Nos. 2iii 10 Micron pre Filters (Microvee)150 mm thick Lot 113 Civil worksAll civil works pertaining to Air-conditioning likebreaking, making, painting of walls, glass etc. as Lot 1required as per site conditions.Note 1: Catalogues of all equipments shall be enclosedwith Compressor rating charts.Note 2: Incoming Power supply near indoor unit will beprovided by o<strong>the</strong>r agencies.Note 3: Taxes to be included in <strong>the</strong> price of equipments/accessories...SUB TOTAL FOR ANCILLARY WORKSTOTAL CONTRACT VALUE FOR EXHAUST WORKS8 of 9 KHANDEKAR ASSOCIATES


CPCB Zonal Office, BangaloreSummaryPROPOSED CPCB ZONAL OFFICER AREASUMMARY SHEET - ACMV WORKSSL NODESCRIPTIONTOTAL VALUE1 TOTAL FOR VRV SYSTEM -2 TOTAL FOR MISCELLANEOUS -3 TOTAL FOR EXHAUST WORK -GRAND TOTAL FOR THE ENTIRE AC WORKS-9 of 9 KHANDEKAR ASSOCIATES