In this issue<br />
News<br />
■ Cooperation: New<br />
Solution for Fat<br />
Determination 3<br />
Application<br />
■ Determining<br />
markers for fatty<br />
acid decomposition 4<br />
■ FAMEs: <strong>Automated</strong>,<br />
Accurate and Reproducible Fatty Acid<br />
Derivatization and Determination 8<br />
Innovation<br />
■ Polymer analysis:<br />
Efficient <strong>Automated</strong> Pyrolysis GC 12<br />
■ Drugs of abuse:<br />
Extraction in seconds 14<br />
■ MAESTRO-Software:<br />
Perfectly Synchronized<br />
Sample Prep and Analysis 24<br />
Interview<br />
■ Robert J. Collins, Ph.D., President<br />
GERSTEL, Inc.: Looking<br />
forward to shaping the future<br />
of the business 18<br />
Report<br />
■ Archaeology meets chemistry:<br />
Peeking into Pharaoh’s wine glass 21<br />
GERSTEL online<br />
You can find more information on products,<br />
applications and services on the GERSTEL<br />
home page at www.gerstel.com.<br />
2<br />
GERSTEL Solutions Worldwide Editorial<br />
International Sales under new leadership<br />
As of July 2008, Ralf Löscher, Ph.D. has joined GERSTEL as<br />
International Sales Manager. A passionate marathon runner<br />
with a Ph.D. degree in biology, Dr. Löscher brings new energy<br />
to the International Sales team, coupled with extensive experience<br />
in the international analytical instrumentation business.<br />
Before joining GERSTEL, the frequent flyer was International<br />
Sales Manager for a reputable supplier of GC and LC Time of<br />
Flight (TOF) Mass Spectrometry systems and had before that<br />
worked for a major international corporation, responsible for<br />
sales of LC and LC/MS instrumentation in Germany. Among<br />
Ralf Löscher’s many activities in his first year in office have<br />
been participation in the Analytica China and ArabLab exhibitions, reinvigorating and refocusing<br />
GERSTEL activities in growth markets with a stronger presence and forming<br />
new contacts and alliances.<br />
GERSTEL introduces<br />
<strong>Automated</strong> Disposable Pipette<br />
Extraction (<strong>DPX</strong>)<br />
Disposable Pipette Extraction (<strong>DPX</strong>) is a fast and efficient SPE<br />
technique used for a wide range of applications such as drugs<br />
of abuse and therapeutic drug monitoring. Only 200 - 250 µL of<br />
sample is needed to reach the required limits of detection using a<br />
fully automated <strong>process</strong>. The extraction step is performed in 30 -<br />
60 seconds and the complete <strong>process</strong> including elution and rinse<br />
steps takes 3 - 6 minutes depending on the application. Additionally,<br />
automated <strong>DPX</strong> is performed during the GC or LC run of the preceding sample ensuring<br />
maximum throughput and best possible GC/MS or LC/MS system utilization. Elution<br />
requires only a small amount of solvent, which means that <strong>DPX</strong> effectively provides<br />
a concentration step. For many applications, such as pesticides in fruit and vegetables,<br />
solvent evaporation is not required. For more information on the <strong>DPX</strong> system, please see<br />
article on page 14.<br />
Keeping VOCs and SVOCs out of car interiors<br />
All leading worldwide car manufacturers and a large number of their suppliers rely on<br />
GERSTEL technology. Analyses are regularly performed to ensure that materials used in or<br />
near the vehicle interior do not emit dangerous levels of Volatile and Semi-Volatile Organic<br />
Compounds (VOCs and SVOCs). A method that is often used world-wide is the VDA Method<br />
278 from the German Automobile Producers Association (VDA). The VDA 278 method specifies<br />
thermal desorption/ thermal extraction of materials that are placed directly in thermal<br />
desorption tubes followed by GC/MS determination. Some manufacturers have their own<br />
methods based on GERSTEL equipment. Recently, two new methods were established<br />
by a renowned leading worldwide<br />
manufacturer. One meth-<br />
od complements the VDA 278<br />
method in the determination of<br />
emissions from materials used<br />
in car interiors; the other method<br />
specifies direct air monitoring<br />
inside the passenger cabins<br />
of vehicles. As far as GER-<br />
STEL Solutions Magazine is informed,<br />
the methods are to be<br />
used by all world-wide operations<br />
including suppliers. Both<br />
methods specify the GERSTEL<br />
Thermal Desorption System<br />
(TDS 3) with Thermal Desorption<br />
Autosampler (TDSA) in combination<br />
with a GERSTEL Cooled<br />
Injection System (CIS 4).<br />
News<br />
Imprint<br />
Published by<br />
GERSTEL GmbH & Co. KG<br />
Eberhard-<strong>Gerstel</strong>-Platz 1<br />
45473 Mülheim an der Ruhr<br />
Germany<br />
Editorial Director<br />
Guido Deußing<br />
ScienceCommunication<br />
Neuss, Germany<br />
guido.deussing@t-online.de<br />
Translation and editing<br />
Kaj Petersen<br />
kaj_petersen@gerstel.de<br />
Scientific advisory board<br />
Eike Kleine-Benne, Ph.D.<br />
eike_kleine-benne@gerstel.de<br />
Oliver Lerch, Ph.D.<br />
oliver_lerch@gerstel.de<br />
Malte Reimold, Ph.D.<br />
malte_reimold@gerstel.de<br />
Contact<br />
gerstel@gerstel.com<br />
Design<br />
Paura Design, Hagen, Germany<br />
www.paura.com<br />
GERSTEL Solutions Worldwide – March 2009<br />
ISSN 1619-0076