13.07.2015 Views

home automation - Bpt Mitho 3 w 1

home automation - Bpt Mitho 3 w 1

home automation - Bpt Mitho 3 w 1

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Electric <strong>automation</strong> systemcomponents.OH/T.01Control terminalHome <strong>automation</strong> control terminal, back-lit 3,” LCD touch screen display,installation on wall.General characteristicsDisplay: Back-lit LCD touch screen displayProtection rating: IP30Operating temperature: from 0° C to +3° CDimensions: 116x9x27 mmPower supply: from bus lineConnections to system: non-polarised twisted pairThermal characteristicsNo. of heating zones: up to 20Operating mode: Manual, Automatic, System BypassSelectable programs: Heating, CoolingAnti-freeze temperature: +8° CField of temperature adjustment: from +2° C to +3° CHome <strong>automation</strong> zone characteristicsNo. of <strong>home</strong> <strong>automation</strong> zones: up to 2No. of controls: up to 2Control functions: direct, impulse, on/off, step-by-step, house, dimmerTimer controls: up to 0 programmableNo. of scenarios: 16 programmableNo. of activatable lights: up to 100No. of activatable openings: up to 0OH/A.01Power supplyThis is always required for the system to work as it manages the powersupply of all the devices in the system (control terminal, zone modules,relay modules, etc.) directly via bus (non-polarised twisted pair). It has 2terminals for connection to an optional back-up battery.General characteristicsPower supply: 230 V 0/60 Hz electronically protectedElectrical input: 10 VAEmergency power supply: 2 V DC, AC 00 mA (from external devices)Operating temperature: from 0° C to +3° CDimensions: low-profile 6-unit module for installation on DIN railConnections to system: non-polarised twisted pairOH/ASSupplementary power supplierThe Hoasis Plus emergency power supply cuts in automatically in theevent of a black-out, preserving the power supply to all the devices inthe system so that all the connected electrical applications return to theirprevious status when the power supply is restored. The power supply mustbe connected to 2 lead accumulators (OH/B06); the emergency powersupply recharges them, guaranteeing efficiency and a long working life.General characteristicsPower supply: 230 V 0/60 Hz electronically protectedPower absorption: 3 VAEmergency power supply: 2 V CC 00 mA (from OH/B06)Operating temperature: from 0 °C to +3° CDimensions: low-profi le 8-unit module for installation on DIN railConnections to system: non-polarised twisted pair30

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!