<strong>Vent</strong>-Scrub® <strong>Vapor</strong> <strong>Phase</strong> <strong>Adsorbers</strong>Models VSC-200, VSC- 400, VSC-1000 and VSC-2000Data SheetApplicationsThe <strong>Vent</strong>-Scrub® adsorbers have been proven to be the simplestand most cost effective way to treat malodorous and VOC emissionproblems. Sturdy steel construction and specially formulated corrosionresistant internal coating ensures long service life andlow maintenance. Applications for <strong>Vent</strong>-Scrub® adsorbers include:J API separator ventsJ VOC control from soil vapor extraction (SVE)systems and airstrippersJ Wastewater and product storage tank ventsJ Process ventsJ Refinery and chemical plant wastewater sewer ventsJ Laboratory hood exhaustsInstallation, Startup and Operation<strong>Siemens</strong> can provide a total service package that includes utilizingOSHA trained personnel providing on-site carbon changeouts,packaging and transportation of spent carbon for recycling at ourreactivation facilities, where the contaminants are thermallydestroyed.We provide instructions on sampling the spent carbon andcompletion of our spent carbon profile form. Spent carbonacceptance testing can be performed at our certified laboratory.When requested, a certificate of reactivation will be issued.Benefits and Design FeaturesJ Durable, carbon steel constructionJ Abrasion and corrosion resistant baked epoxy lining;urethane exterior finish ((<strong>Vent</strong>-Scrub® 1000 and 2000)J Ready-to-use systems: simple installation andoperationJ Applications to 500 SCFMJ The <strong>Vent</strong>-Scrub® 1000 and 2000adsorbers have forklift channels for easy handlingJ Adsorber vessels are UN/DOT approved transportationcontainers for RCRA hazardous spent carbonJ Hose kit and pipe manifold options are available tosimplify installation and operationPiping Manifold (Optional)J 2" or 3" sch 80 PVC piping and valves (optional carbonsteel and stainless steel piping)J Series or parallel operationJ Sampling ports and pressure gaugesJ Flexible hoses with Kamlock fittings allow easyinstallation and removal during service exchangeoperationsWater Services


Pressure Drop (in H 2 O)Pressure Drop (in H 2 O)Pressure Drop (in H 2 O)Pressure Drop (in H 2 O)Specification<strong>Vent</strong>-Scrub® AdsorberModel No. 200 400 1000 2000Dimensions, diameter xoverall height22" x 34" 32" x 43" 48" x 61" 48" x 97"Inlet Connection 2" FNPT 4" FNPT 4" FNPT 4" FNPTOutlet Connection 2" MPT 4" FNPT 4" FNPT 4" FNPTManway Top Top 18" Top 18" TopInternal Distribution a PVC PVC PVC PVCInterior Coating Epoxy Epoxy Epoxy EpoxyExterior Coating Enamel Enamel Epoxy/Urethane Epoxy/UrethaneCarbon Fill Volume (Cu.ft.) d 6.8 14 34 68Cross Sectional Area (sq.ft.) 2.8 4.9 12.3 12.3Approx. Carbon Weight (lbs) 200 400 1000 2000Empty Vessel Weight (lbs) 50 80 890 1190Flow, CFM (max.) 100 300 500 500Pressure, psig (max.) 3 3 14.9 14.9Temperature, deg. F (max) c 140 140 140 140Vacuum, in. Hg (max.) N/A N/A 12 b 12 ba Carbon steel and stainless steel internals are also available.b For vacuum greater than 12 in. Hg on <strong>Vent</strong>-Scrub® 2000 Adsorber, contact your <strong>Siemens</strong>representative.c For higher temperatures, stainless and carbon steel internals are available.For detailed dimensional information or drawings, contact your local <strong>Siemens</strong> salesrepresentative.d Carbon fill volumes are based on a loaded density of 29.5 lb./ft3. Actual volume will vary withproduct density.WarningThe adsorption of organic compounds ontoactivated carbon generates heat. In rare instances,adsorbed compounds may also react on the carbonsurface to generate additional heat. If these heatsources are not properly dissipated, the carbon bedtemperature may rise to the point where thecarbon can ignite, leading to a fire or otherhazardous condition. A description of industryaccepted engineering practices to assure thedissipation of heat and safe operation of the carbonbed can be provided upon request. In certainapplications where the risk of ignition is significant,activated carbon may not be a recommendedtreatment technology. Please contact yourTechnical Sales Representative for moredetails. Wet activated carbon readily adsorbsatmospheric oxygen. Dangerously low oxygenlevels may exist in closed vessels or poorlyventilated storage areas. Workers should follow allapplicable state and federal safety guidelines forentering oxygen depleted areas.All information presented herein is believed reliableand in accordance with accepted engineeringpractices. <strong>Siemens</strong> makes no warranties as to thecompleteness of this information. Users areresponsible for evaluating individual productsuitability for specific applications. <strong>Siemens</strong>assumes no liability whatsoever for any special,indirect or consequential damages arising from thesale, resale or misuse of its products.Pressure Drop<strong>Vent</strong>-Scrub 200 AdsorberCarbon: 3X6, 4X8, 4X10, 4MM PelletPressure Drop<strong>Vent</strong>-Scrub 400 AdsorberCarbon: 3X6, 4X8, 4X10 & 4MM PelletPressure Drop<strong>Vent</strong>-Scrub 1000 AdsorberCarbon: 3X6, 4X8, 4X10 & 4MM PelletPressure Drop<strong>Vent</strong>-Scrub 2000 AdsorberCarbon: 3X6, 4X8, 4X10 & 4MM Pellet10.01616229.01414208.0187.01212166.04x10104x10104X10144X104x84x84X8124X85.03x64MM P83x64MM P83X64MM P103X64MM P4.06683.04462.041.02220.00 20 40 60 80 100 12000 100 200 300 40000 100 200 300 400 500 60000 100 200 300 400 500 600Flow (SCFM)Flow (SCFM)Flow (SCFM)Flow (SCFM)<strong>Siemens</strong> Industry, Inc.866.613.5620Subject to change without prior noticeOrder No.: WS-VSC-ds-0413Printed in USA© 2013 <strong>Siemens</strong> Industry, Inc.VOCarb and Westates are trademarks of <strong>Siemens</strong>, its subsidiaries or affiliates.The information provided in this flyer contains merely general descriptions orcharacteristics of performance which in case of actual use do not always applyas described or which may change as a result of further development of theproducts. An obligation to provide the respective characteristics shall only existif expressly agreed in the terms of contract.All product designations may be trademarks or product names of <strong>Siemens</strong> AGor supplier companies whose use by third parties for their own purposes couldviolate the rights of the owners.www.siemens.com/es

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!