13.07.2015 Views

T Series Industrial Dry Block Calibrators

T Series Industrial Dry Block Calibrators

T Series Industrial Dry Block Calibrators

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

T <strong>Series</strong><strong>Industrial</strong> <strong>Dry</strong> <strong>Block</strong><strong>Calibrators</strong>eurotron“Excellence in measurements”The Eurotron range of field dry blockcalibrator consist of there separatemodels for calibrating temperaturesensors, loop and switches in atemperature range between -48 and1100 °C. These self-contained units areportable, flexible and are suitable forboth field and laboratory temperaturecalibration.Eurotron control technology ensureextremely fast setting time whilstoffering an excellent temperaturestability and well to well uniformity.The new redesigned controller deliverhigh display reading accuracy. Forimproved measurement uncertainty,Eurotron provide a complete range of“working standard” both traceable andUKAS certified.Multi-hole insert are available to suit thevariety of probe size and theprogrammable ramp and switch inputmake simple and quick the testing oftemperature switches.The MicroCal T series is available astemperature source only, or TC versionwhich provide dual electrical input forThermocouple and RTD’s.The standard RS232 and softwarepackage allow to run automatic test andcalibration procedure.MicroCal T100, uses a special peltierelement to cool from ambienttemperature down to 48 °C. Features:• Wide range from -48 to 150 °C• Excellent stability to 0.03 °C• well to well uniformity of 0.1 °C• Reading accuracy ±0.15 °CMicroCal T500, suitable for intermediatetemperature range offers very fastheating and cooling time. Features:• Wide range from 20 to 550 °C• Excellent stability to 0.05 C• well to well uniformity of 0.2 °C• Reading accuracy ±0.3 °CMicroCal T1100, for very hightemperature range, still do notcompromise in technical specification.All the necessary precaution are taken toensure maximum safety and temperaturestability. Features:• Wide range from 200 to 1100 °C• Excellent stability to 0.3 °C• Ceramic insulation for safety andstability• Customised inconel insertsSPECIFICATIONSParameter MicroCal T100 MicroCal T500 MicroCal T1100Temperature range -48°C to 150°C (@20°C)Tamb to 550°COptional to 600°C200 to 1100°CStability ±0.03°C ±0.05°C @ 450 °C ±0.3°C @ 1000 °CAccuracy ±0.15°C ±0.3°C ±0.3% rdgResolution0.01°CUniformity (well to well) ±0.1°C ±0.2°C ±0.2°CHeating time 20°C/min 20°C/min 20°C/minCooling time 22°C/min 25°C/min 18°C/minWell size 35 x 135mm 50 mm 44 mmWell depth 150 mm 185 mm 225Standard insert 4-4.5-5.5-6.5-8.5-10.5mm 4.5-6.5-9.5-17 mm 7-9-11-13.5 mmphisical dimension 16 x 33 x 34 cm 14 x 37 x 30 cm 17 x 45 x 33 cmPower supply 110 or 220 Vac, 50/60 Hz 110 or 220 Vac, 50/60 HzWeight 10 Kg 8 Kg 11 KgInterfaces RS-232 standard RS-232 standard RS-232 standardCertificate included includedCAPABILITIESFeatures T100 T500 T1100Range -48°C to 150°C Tamb to 550°C T200 to 1100°CRemovable inserts• • •Customised inserts optional optional optionalFast heating/Cooling• • •Switch test• • •Fully Programmable ramp• • •Electrical inout for Reference and UUT TC version TC version TC versionSerial Interface RS232• • •ATCS compatible• • •Documenting(offline procedure) with T module with T module with T moduleOrdering InformationsModelT100 <strong>Dry</strong> <strong>Block</strong> Temperature CalibratorT500 <strong>Dry</strong> <strong>Block</strong> Temperature CalibratorT500S <strong>Dry</strong> <strong>Block</strong> Temperature Calibrator (600 °C)T1100 <strong>Dry</strong> <strong>Block</strong> Temperature Calibrator (1100 °C)Version0 basic versionTC Dual input for RTD’s and TC (Ref and UUT)Power supply1 = 115 Vac, 50/60 Hz2 = 220 Vac, 50/60 HzT100 - TC-2 Typical ordering codeStandard delivery includes: Standard insert, switches test leads, instructionmanual, calibration certificate with data, CalPman basic software package.Accessories and inserts: See accessories pageElectrical Input (TC version) Range AccuracyRTD’s type PT100 (IEC), 3,4 wires -100°C to 700 °C 0.3°CT/C’s type J 0 to 1000°C 1°CT/C’s type K, N, R, S 0 to 1300°C 1°CAutomatic Temperature Calibration System (ATCS)Save time and effort by performingon-line calibration procedure. TheATCS system is an high accuracymodular scanner for T/C’s, RTD’spressure switches and temperaturetransmitters controlled by theCalPman advanced version softwarepackage. The system is able to handleup to 32 temperature sensorssimultaneously. Learn more on howATCS can improve efficency in yourcalibration routine and saving money.1


T Fluid <strong>Series</strong>Micro BathTemperature Calibratoreurotron“Excellence in measurements”The MicroCal T100/T200 fluidrepresent one of the smaller portableliquid bath available on the market.Wherever you go with this compactself contained liquid bath you cancount on their performance. Bothmodel offer an excellent stability to0.02 °C and an improved uniformityor 0.03 °C for low uncertainty budgetwhen using a reference thermometer.The uniformity is maintained by amagnetic mixer which speed isadjustable ti suit the fluid viscosity.The excellent display accuracy it hasbeen greatly improved to 0.15 °C sothat you can use the bath forcalibration without a referencethermometer.We have obtained the stability andaccuracy performance of a liquid bathinto a small self contained dry blocksize.EXTREME FLEXIBILITY- 2 IN 1When the use of the liquid it is notaccepted for your application, in suchcases like risk of contamination mightoccur, then the MicroCal T Fluid offerthe great flexibility to add a “<strong>Dry</strong><strong>Block</strong> insert” turning the unit into acommon <strong>Dry</strong> <strong>Block</strong> temperaturecalibrator. These calibrator features• Two different models• Temperature range from -35 to200 °C• Display Accuracy to 0.15 °C• Stability 0.02 °C• Uniformity to 0.03 °C• Large Capacity 400 cc• 2 in 1 Liquid Bath and <strong>Dry</strong> <strong>Block</strong>• Dual Electrical Input (TC version)• RS232 interface as standard• Switch test contact capture• Programmable RampAPPLICATIONThe MicroCal T100/T200 are theperfect solution when you needlaboratory accuracy in the field, orwhen you calibrate short, square orodd-shaped sensors. The liquid batheliminate the source of error relatedto immersion depth and fit which youcan find using common dry blockcalibrator. The fluid media offer anexcellent thermal contact anduniformity. These calibrators are theperfect solution when calibratingsolution.• Short, odd-shaped and squaresensors• Bimetal and glass thermometerTECHNICAL SPECIFICATIONSParameter MicroCal T100 Fluid MicroCal T200 FluidTemperature range -30 °C to 125 °C (@ 20 °C) Tamb to 200 °CStability ±0.02 °C @ 5 °C ±0.02 °C @ 150 °CAccuracy ±0.15 °CResolution 0.01 °CUniformity (radial) ±0.03 °C as liquid bathUniformity(axial) ±0.03 °C as liquid bathHeating Time 12 °C/min 10 °C/minCooling Time 9 °C/min 3 °C/minWell Size50 mm (400 CC capacity)Well Depth150 mmphisical Dimension 16 x 33 x 35 cm Weight 8 KgPower Supply 110 or 220 Vac, 50/60 Hz 110 or 220 Vac, 50/60 HzInterfaces RS-232 standard RS-232 standardCertificate included includedElectrical Input (TC version) Range AccuracyRTD’s type PT100 (IEC), 3, 4 wires -100 °C to 700 °C 0.3 °CT/C’s type J 0 to 1000 °C 1°CT/C’s type K, N, R, S 0 to 1300 °C 1°CAutomatic Temperature Calibration System (ATCS)Save time and effort by performing on-line calibration procedure.The ATCS system is an highaccuracy modular scanner forT/C’s, RTD’s pressure switchesand temperature transmitterscontrolled by the CalPmanadvanced version softwarepackage. The system is able tohandle up to 32 temperaturesensors simultaneously. Learnmore on how ATCS can improveefficency in your calibrationroutine and saving money.FEATURESFeatures T100 Fluid T200 FluidRange -30 °C to 125 °C Tamb to 200 °CType Liquid bath Liquid bath<strong>Dry</strong> <strong>Block</strong> Insert optional optionalFast heating/cooling • •Switch test • •Fully programmable ramp • •Electrical inout for reference and UUT TC version TC versionSerial Interface RS232ATCS compatible••••Documenting (off-line procedure) with T module with T moduleOrdering InformationsModelT100-Fluid MicroBath Temperature CalibratorT200-Fluid MicroBath Temperature CalibratorVersion0 Basic versionTC Dual input for RTD’s and TC (Ref and UUT)Power Supply1 = 115 Vac, 50/60 Hz2 = 220 Vac, 50/60 HzT100 - TC - 2 Typical ordering codeStandard delivery includes: 2 x 500 cc silicon oil bottle, closing cup for transport,empty fluid system, support for glass thermometer, electrical power cord, sparesfuses, clamping-screw adapter for bushes, switch test leads, instruction manual,calibration certificate with data and soft vinyl transport case and CalPman basicsoftware package.Accessories and inserts: See accessories page2


T/T Fluid <strong>Series</strong>Inserts andaccessorieseurotron“Excellence in measurements”T100 INSERTSOrdeing codeT100-INS-A Blank insertT100-INS-B 6 holes: 4, 4.5, 5.5, 6.6, 8.5, 10.5 mm (included as standard)T100-INS-C 2 holes: 6.5 mm, 19.5 mmT100-INS-S3 Custom insert 3 holes maxT100-INS-S6 Custom insert 6 holes maxT100-INS-S10 Custom insert 10 holes maxINS-A INS-B INS-C INS-S3 INS-S6 INS-S10blank4.5 mmmax. 3 holes max. 6 holes max. 10 holes5.5 mm4 mm6.5 mm6.6 mm10.5 mm8.5 mm19.5 mmT500 INSERTSOrdeing codeT500-INS-A Blank insertT500-INS-B Well insert 1 hole 9.5 mmT500-INS-C Well insert 1 hole 17.5 mmT500-INS-D Well insert 1 hole 10.0 mmT500-INS-E Well insert 1 hole 11.0 mmT500-INS-F Well insert 1 hole 12.0 mmINS-A INS-B INS-C INS-D INS-E INS-Fblank9.5 mm 17.5 mm10 mm11 mm 12 mmT1100 INSERTSOrdeing codeT100/200 FLUID INSERTSOrdeing codeT1100-INS-A Blank insertTF-INS-D Blank aluminium insert 60 x 170 mmT1100-INS-B 4 holes: 7, 9, 11, 13.5 mm, included as standardTF-INS-E Drilled aluminium insert 60 x 170 mm with: 2 x 4 mm, 1 x 4.5 mm,INS-AINS-B1 x 5.5 mm, 2 x 6.5 mm, 1 x 8.5 mm, 1 x 10.5 mm and 1 x 12.5 mmblank INS-D INS-E7 mm11 mm13.5 mm9 mmblank4 mm4.5 mm5.5 mm6.5 mm6.5 mm8.5 mm10.5 mm12.5 mmAccessoriesEE880063 Aluminium carrying case (T100, T500)BB880047 Vinyl carrying case with shoulder strap (T100, T500)EE2D2240 Aluminium carrying case (T1100)2DC505 Alumium transit case (37 x 29 x 42 cm) (T100/T200 Fluid)BB530208 USB cable/converterBB260215 CalPman 2008, Vista/XP compatibleBB260130 CalPman 2008 advanced, Vista/XP compatibleEE880063EE2D22402DC505BB530208BB880047BB260215BB2601303eurotron“Excellence in measurements”Eurotron Instruments (UK) ltdUnit 8 The Centre, Holywell Business ParkNorthfield Road, Southam, CV47 0FP UKT: +44(0)1926 810472 F: +44(0)1926 813569www.eurotronuk.com sales@eurotronuk.com• • • • • Distributed by:

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!