<strong>Thermal</strong> <strong>Shock</strong> <strong>Chamber</strong>TSE11CAT.NO.E01133-T1202


ESPEC offers a compact, but highly performantthermal shock chamber ideal for the requirements oftest standards with small and low-volume specimen.Equipped with superior temperature recovery performancecapable of answering the requirements of severe test specifications,this thermal shock model offers a wide test area in a compact, slim design.1 *The paperless recorder and additional overheat protector are optional.


CharacteristicsA high performance compact package to meet severe test requirements.A temperature recovery time ofless than 5 minutes is achievedin 2 zones (150 and 65)without auxiliary coolingBy realizing a temperature recovery timeof less than 5 minutes for the upstreamair in the 2 zones (150 and 65),we have achieved performance equivalentto that of a large thermal shock chamberwithout having to use auxiliary coolingby means of liquid carbon dioxide, whichwas required in previous compactthermal shock chamber.Complies with MIL-STD-883Hand other test standardsThis compact thermal shock chambersatisfies the temperature cycle testrequirements of MIL-STD-883H andother test standard (see page 5).Smooth specimen transferThe "soft-move mode" is used to reducevibration shock when specimens aremoving between the hot and coldchambers.High-temperature exposureExamples of temperature uniformity Test conditionsHigh temperature exposure 150 30 min.Low temperature exposure 65 30 min.SpecimenPlastic molded IC 2kgLow-temperature exposure Temperature uniformity measurement methodThermocouples were embedded in 10 plasticmolded ICs (16 pin DIPs), which were thenplaced on two levels in each of the cornersand in the center of a specimen basket.Uniform temperaturedistribution across specimensHigh temperature uniformity performanceensures consistent stress on specimens.Within 1.5Sensor temperature(Test area: upstream)Within 1.02


CharacteristicsColor LCD interactivetouch-screen systemOperation and settings simplified by theuse of a touch-screen LCD display(instructions displayed on-screen).At-aglance confirmation of test patterns,test area temperatures, temperaturecycles, upstream / downstream control,and trend graphs display.ControllerTest areaControl panelSetting Interactive key input by touch panelDisplay TFT Color LCDRAM (selected entry): a maximum of 40 patterns can be enteredTest patternsROM (built-in): contains 10 test standard patternsAuxiliaryfunctions Timer preset Program memory Test continuity selection Automatic power shut-off Overheat/ Overcool protection Programmed time display Upstream/ downstream sensor selection Test suspension Stable time control Test completion mode selection Quick exposure control Trend graph Power recovery mode Alarm history display Automatic defrost Sensor calibration Temperature recovery time setting RS-485 communicationLarge 10.9-liter-capacity test areaFeatures a 10.9-liter test area, twice thatof our previous model. The volume thatcan be processed is greatly increased,and a 210 297mm printed circuit boardcan be tested in the horizontal position.Test area anti-drop mechanismA braking system fitted to the drivemechanism prevents specimens fromfalling into the test area when thechamber stops operation.Other protection mechanisms areequipped to ensure that the specimendoes not fall.Easy wiring accessA cable port is provided on the rightside to allow easy wiring of specimensfor measurement during high and lowtemperaturecycle tests.Comprehensive safety systemA dual safety system automaticallystops the test area drive mechanism ifthe door is left open, and automaticallylocks the door when the test area is inmotion.Equipped with casters for mobility3Cable port (50mm, shown with cap installed)


CharacteristicsA whole range of environmentally-friendly featuresReduced power consumptionReduced power consumption is animportant issue for our customers. Thiscompact thermal shock chamberemploys number of measures such asthe use of electronic expansion valve toregulate the refrigeration capacitycontrol. Specifically aimed at energysavings.Required footprint(Installation space: 2.88 m 2 )600Rear intake andceiling exhaustTop viewUnit: mmMinimum footprintIts slim design requires only 2.88m 2installation space (31 ft 2 ). Ideal fornarrow spaces in labs or factories.22501050Material labeling for easy recyclingPlastic molded components are labeledand easily detachable to make recyclingeasier for future disposal of theequipment.600300 680 3001280Paperless recorder (option)Built-in paperless recorders is availableto record temperatures from varioussources, such as test area temperature.Recording is possible on Compact FlashCard or via USB port.Paperless recorder (optional)4


SPECIFICATIONSModelSystemPerformance *1 Test areaConstructionHotchamberClodchamberTemp. recoveryHigh temp. exposure rangeLow temp. exposure rangeTemperature fl uctuation *2Pre-heat upper limitTemp. heat-up time *3Pre-cool lower limitTemp. pull-down time *3Recovery conditionsTemp. recovery timeTest areaHeaterSystemCompressorRefrigerantCondenserCoolerAir circulatorRefrigerationunitFittingsTest area load resistanceSpecimen basket load capacityInside dimensions (WHD)Test area capacityOutside dimensions (WHD) *4WeightAllowable ambient conditionsPower supply(Voltage fl uctuation: rating 10)TSE-11-A2-zone transition by vertical transfer of specimen60 to 200 (140 to 392)65 to 0 (85 to 32)0.5 (0.9)200 (392)Ambient temp. to 200 (392) within 30 min.80 (112)Ambient temp. to 80 (112) within 90 min. 2 zonesHigh temperature exposure: 150 (302), 30 min.Low temperature exposure: 65 (85), 30 min. Sensor position: Upstream Specimen: Plastic molded ICs 2 kgwithin 5 min.Shelf brackets on 2 levels of fi xed locationStripped wire heaterMechanical cascade refrigeration systemRotary 1.5 kW 2R508A R404AAir-cooled condenserPlate fi n cooler, cold accumulatorSirocco fanSpecimen power supply control terminal, integrating hour meter without reset,time signal (2), cable port 50 mm, (right side), casters with leveling feer (4), power cable8 kg2kg per basket (equally distributed load)200V AC3 3W 50/60Hz320148230mm (12.65.89 inch)10.9 L68016251050mm (26.86441.3 inch)approximately 390kg0 to 40 (32 to 104)220V AC3 3W 60Hz380V AC3 4W 50Hz400/415V AC3 4W 50Hz400V AC *53 4W 50HzMaximum load current 26A 25A 17A 17A 17AExhaust heat quantity *617,585kJ/h *760dB or less*1 The performance values are under the conditions of a 23 ambient temperature, relative humidity of 65%rh, rated voltage, and no specimen. Heat up timeand pull down time are those of single-unit operation of each chamber.*2 The performance values are based on IEC60068-3-5:2001, JTM K07:2007.*3 Temperature heat-up/pull-down time account for performance of each temperature chamber.*4 Excluding protrusions. *5 Compliance with CE Marking. *6 At ambient temperature 23.*7 At 1m from front of chamber, 1.2m from floor. (ISO 1996-1:2003 A-weighted sound pressure level) depending on environmentDANGERDo not use specimens which are explosive or inflammable, or which contain suchsubstances. To do so could be hazardous, as this may lead to fire or explosion.Do not place corrosive materials in the chamber. If corrosive substances orhumidifying water is used, the life of the unit may be significantly shortened.Do not place life forms or substances that exceed allowable heat generation.CAUTIONBe sure to read the user’s manual before operation.6


SAFETY DEVICESLeakage breaker (200, 220, 380, 400/ 415V AC)Circuit breaker (400V AC)Electrical compartment door switchHot chamber overheat protection switchCold chamber overheat protection switchHot chamber overheat protector (Controller)Cold chamber overheat / overcool protectors (Controller)Test area overheat and overcool protectors (Built-in controller)Test area overheat / overcool protectorsRefrigerator high pressure switch<strong>Thermal</strong> relay for compressorTemperature switch for compressorTemperature switch for air circulator<strong>Thermal</strong> relay for air circulatorMotor inverterMotor reverse prevention relayHot chamber door switchCold chamber door switchTest area holdDoor lock mechanismsFuseSpecimen power supply control terminalOPTIONSPaperless recorderRecords temperature of each sectionsuch as the temperature inside thechamber.Number of inputs:PL1S: 1 (5 more channels can be turned ON)Data saving cycle: 1 secPL3S: 3 (3 more channels can be turned ON)Data saving cycle: 1 secPL3L: 3 (3 more channels can be turned ON)Data saving cycle: 5 secTemperature range: 100 to 220External memory:CF memory card port(Includes a 256MB CF card)Languag: ENG, JPN can be changedACCESSORIESSpecimen basket (18-8 Cr-Ni stainless steel, 5 mesh metal basket) W320H35D230mm Load capacity: 2kg (equally distributed) 2Cartridge fuse (5 A) 1Cable port rubber plug 2Wirefisher 1User's manual (CD-R, booklet)1 setTemperature recorder (digital display)Temperature range: 100 to 220Effective recording chart width:100mmRK-61: 1penRK-63: 3 pensRK-64: 6 dotsRecorder wiringPreparation of a power cable, temperaturesensor, and conductor groundingwire for additional installation in thefuture.7


OPTIONSTerminal for recorderTo output temperature values fromthe test area, hot chamber, coldchamber.Total cycle counterIndicates cycle counts.Display range: 1 to 99999999(with reset function)Specimen basketEquivalent to standard accessory.Material: stainless steel (5 mesh)Specimenpower supplycontrolterminalTime signalThermocoupleExternal alarmterminal (option)Attached to specimens to measurespecimen temperature.2m4m6mT JIS C 1602 with ball attachedAuxiliary cooling injector (LCO2)Used to reduce the temperaturerecovery time of low temperatureexposure by injecting liquefiedcarbon dioxide at the beginning ofexposure.Auxiliary cooling injector (LN2)Used to reduce the temperaturerecovery time of low temperatureexposure by injecting liquefiednitrogen at the beginning ofexposure.Additional overheat protectorAdditional preventive measures canbe taken for excessive temperaturerise in the chamber, in addition tothe standard equipped overheatprotectors.External alarm terminalIf the safety device of the chamberis activated, the external alarmterminal will notify it to a remotepoint.Emergency stop pushbuttonStops the chamber immediately.Cable port rubber plugPrevents air leakage from the cableport.Anchoring fixturesUsed to bolt the chamber to the floor.Power cableUsed to connect to the primarypower source.5m10mColor specification<strong>Chamber</strong> can be painted to anydesired color. (a color sample isrequired)InterfaceComputer interface GPIBSerial interface RS232C*Select one, instead of standard RS485.Communication cableRS485GPIBRS232C5m/ 10m/ 30m2m/ 4m1.5m/ 3m/ 6mSome photographs listed in this catalog contain Japanese display.8


http://www.espec.co.jp/englishHead Office3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, JapanTel : 81-6-6358-4741 Fax : 81-6-6358-5500ESPEC NORTH AMERICA, INC.Tel : 1-616-896-6100 Fax : 1-616-896-6150ESPEC EUROPE GmbHTel : 49-89-1893-9630 Fax : 49-89-1893-96379ESPEC (CHINA) LIMITEDTel : 852-2620-0830 Fax : 852-2620-0788ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD.Head OfficeTel : 86-21-51036677 Fax : 86-21-63372237BEIJING BranchTel : 86-10-64627025 Fax : 86-10-64627036TIANJIN BranchTel : 86-22-26210366 Fax : 86-22-26282186GUANGZHOU BranchTel : 86-20-83317826 Fax : 86-20-83317825SHENZHEN BranchTel : 86-755-83674422 Fax : 86-755-83674228SUZHOU BranchTel : 86-512-68028890 Fax : 86-512-68028860ESPEC TEST TECHNOLOGY (SHANGHAI) CO., LTD.Tel : 86-21-68798008 Fax : 86-21-68798088ESPEC SOUTH EAST ASIA SDN.BHD.Tel : 60-3-8945-1377 Fax : 60-3-8945-1287Quality Management System Assessedand RegisteredESPEC CORP. has been assessed by andregistered in the Quality Management Systembased on the International Standard ISO9001:2008 (JIS Q 9001:2008) through theJapanese Standards Association (JSA).Registration : ESPEC CORP.(Overseas subsidiaries not included)Environmental Management System Assessedand RegisteredESPEC CORP. Specifications are subject to change without notice due to design improvements.TW2E24C03 (The contents of this catalog is as of February, 2012.) Corporate names and trade names mentioned in this catalog are trademarks or registered trademarks.