13.07.2015 Views

correct handpiece maintenance - everytime

correct handpiece maintenance - everytime

correct handpiece maintenance - everytime

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Rotational <strong>maintenance</strong> system guaranteesthorough cleaning and lubrication of each <strong>handpiece</strong>.Coolant water and air channels are flushed.Care3 Plus Complete PackSingle Rotation Port+ Dual Standard PortsMODELCare3 Plus C1 Type (120V)Care3 Plus C1 Type (230V)Dual Rotation Ports+ Single Standard PortCare3 Plus C2 Type (120V)Care3 Plus C2 Type (230V)ORDER CODEY141-202Y141-204Y141-203Y141-205Specifications• Power Supply : AC 120V or 230V 50/60Hz• Air Pressure : 0.35-0.6 MPa (3.5-6 kgf/cm 2 )• Weight : 7.1 kg (C1 type), 7.2 kg (C2 type)• Dimension : W280 x D275 x H360 mm• Solution Tank Capacity : 350 mLIn full tank about 3,500 <strong>handpiece</strong>s (S mode) arecleaned and lubricated.Connects only to Midwest 4-hole type* Air piping is necessary (3.5-6 kgf/cm2 )AUTOMATIC HANDPIECE CLEANING & LUBRICATION SYSTEM<strong>correct</strong> <strong>handpiece</strong> <strong>maintenance</strong> - <strong>everytime</strong>Contents• Care3 Plus unit • Power cord with L-shaped plug• Maintenance oil (1 litter)• Oil replenish funnel with filter • Mist filter set• Air tube • Air filterLow Speed HandpiecesLow speed <strong>handpiece</strong>s incorporate gearing systems which require extra solution penetration.The NSK rotation system guarantees optimum oil delivery to the internal components of all lowspeed <strong>handpiece</strong>s, while particles in the coolant water and air channels are removed by thecleaning solution.Care3 Plus AdaptorsMODELCare3 Plus ADAPTORSORDER CODEFor ISO E-Type & E-Type LUXE-Type Adaptor U433-035AttachmentsFor High Speed HandpiecesPTL Adaptor Z257-010for PTL-CL-4HV-T CouplingMODELCare3 Plus ADAPTORSORDER CODEFor SironaSR Adaptor ® High SpeedZ257-023Handpieces for Quick CouplingFor W&H ® High SpeedWH Adaptor Handpieces for Roto Quick ® Z257-021CouplingOil & AirFor MACH-QD & CH-QDQD Adaptor Z257-011High Speed HandpiecesB2/M4 AdaptorFor Borden 2-hole High SpeedHandpiecesT904For Bien-Air ® High SpeedBA Adaptor* Handpieces for Unifix ® Z280-022CouplingFor ENDO-MATE TC, DT/F-Type Adaptor* Z280-042TASKAL Wizard HeadsHigh Speed HandpiecesThe critical turbine component, plus all air and water channels of high speed <strong>handpiece</strong>s arethoroughly cleaned and lubricated.For KaVo ® High SpeedKV Adaptor Handpieces for MULTIflex LUX ® Z257-020Coupling*For Care3 Plus only. Don't use when connected to Care3.Check with the dealer for the adaptors to mount other manufactures’ <strong>handpiece</strong>s.* KaVo ® and MULTIflex LUX ® are registered trademarks of Kaltenbach & Voigt GmbH & Co., Germany.Sirona ® is a registered trademark of Sirona Dental Systems GmbH, Germany.W&H ® and Roto Quick ® are registered trademarks of W&H Dentalwerk Bürmoos GmbH, Austria.Bien-Air ® and Unifix ® are registered trademarks of Bien-Air Dental S.A., Switzerland.Spare PartsMODELPRODUCTSORDER CODEMODELPRODUCTSORDER CODEOil & AirMaintenance Oil(1 Bottle)(1 litter)Z016-117AirTube(3m)U508-038Maintenance Oil Set(Pack of 6 Bottles)Y900-138Air Filter U208-352Mist Filter Set(pack of 12 piecese)Y900-159Air Filter Element U508-353SELECTTwo types of units are available according to individual demand.Oil Replenish Funnelwith FilterU433-090Fuse (120V)Fuse (230V)U433-222U433-223C1 TypeSingle Rotation Port+ Dual Standard PortsC2 TypeDual Rotation Ports+ Single Standard PortRotation Port Standard Port Standard PortRotation Port Rotation Port Standard Portwww.nsk-inc.com700 Shimohinata Kanuma-shiTochigi 322-8666,JapanNSK Europe GmbHwww.nsk-europe.deWesterbachstraße 58D-60489 Frankfurt,GermanyNSK United Kingdom Ltd.www.nsk-inc.comGateway1000, Arlington Business Park,Whittle Way, Stevenage,Hertfordshire, SG1 2FP, UKNSK Oceania Pty Ltd.www.nsk-inc.comUnit 22, 198-222 Young St.Waterloo, Sydney,NSW 2017 AustraliaNSK America - Canadian Branchwww.nsk-inc.com1054 Centre St. - Suite 283Thornhill, Ontario, CanadaL4J 8E5NSK Middle Eastwww.nsk-inc.comDubai Airport Free Zone,Room 2W-310,3F West Wing, Dubai, UAETEL : +81 (0)289-64-3380FAX : +81 (0)289-62-5636TEL : +49 (0)69 74 22 99 0FAX : +49 (0)69 74 22 99 29TEL : +44 800 634 1909FAX : +44 800 634 1910TEL : +61 (0)2 8306 3000FAX : +61 (0)2 8306 3030TEL/FAX : +1 905 780 6757Toll Free : +1 866 780 6757TEL : +971 (0)4-299-6644FAX : +971 (0)4-299-6664Powerful Partners ®Specifications are subject to change without notice.PR-D293E Ver.3 07.03.05.Y


Automatic Care3 Plus Is the Key to Handpiece DurabilitySimple to Operate1Fast, user friendly, fully automatic, and economical.Correct <strong>maintenance</strong> performed at regular intervals is a key to high performance and longerlife of your <strong>handpiece</strong>s. NSK designed easy-to-use Care3 Plus to facilitate <strong>handpiece</strong> <strong>maintenance</strong>at your office. Care3 Plus automatically cleans and lubricates up to 3 <strong>handpiece</strong>s atone time with a touch of button. Both high speed and low speed <strong>handpiece</strong>s are processedthoroughly in a single 2-minute operation cycle.Care3 Plus control panel is easy to understand andsimple to operate.Power IndicatorCycle SelectionS : Short Cycle for High Speed HandpiecesL : Long Cycle for Low Speed HandpiecesE : Extra Long Cycle for Speed Reduction Handpieces, etc.Open the door and attach up to 3 <strong>handpiece</strong>sto the Care3 Plus couplings.2After connecting the <strong>handpiece</strong>s, close thedoor. Care3 Plus will not operate if the dooris not properly closed.Error IndicatorAir KeyStart Key3Air ActivationAir supply is activated by the “Air” key.This enables the operator to flush outall residual solution.Easy to CleanAt the touch of a button, the frontcover can be completely removedfor easy cleaning.Solution TankThe solution tank has capacity for maintaining 3,500<strong>handpiece</strong>s (S Mode) before a refill is required. To refillthe tank, simply unscrew the cap on top of the unit andpour in new Care3 Plus solution.Select the S, L, or E mode relevant to each<strong>handpiece</strong> connection location.S: S mode (Approx. 35 seconds)For high speed <strong>handpiece</strong>sL: L mode (Approx. 45 seconds)For low speed <strong>handpiece</strong>sOriginal Air FilterClean air supply is a must for effective<strong>handpiece</strong> <strong>maintenance</strong>. NSKCare3 Plus comes with a highly efficientair filter that can be exchangedand installed easily wherever youdesire.Virtually No MistSpray mist is generally absorbed withinthe Care3 Plus unit by disposable mistfiltration system. Filter sponges are easilyexchanged. (Comes in a pack of 12)Accommodates NSK and OtherBrands’ HandpiecesNSK and all other brands of E-Type low speed <strong>handpiece</strong>sconnect directly to the coupling supplied. NSKhigh speed <strong>handpiece</strong>s require the PTL adaptor.Adaptors are available for direct connection of mostother brands of high speed <strong>handpiece</strong>s.E4: E mode (Approx. 50 seconds)For speed reduction and speed increasing<strong>handpiece</strong>s, etc.*The figures in brackets indicate the clean-lubricate-flushtime for a <strong>handpiece</strong>.The Oil Level IndicatorOil level indicator is ideally located atthe front panel of Care3 Plus unit toclearly show amount of oil in the tank.Power Cord withL-Shaped PlugThe power cord with L-shapedplug allows the Care3 Plus to beinstalled in virtually any surgery location.Convenient Memory FunctionCare3 Plus memory system stores and instantly recalls the last operational setting when thepower switch is turned on. This memory function eliminates the need to repeatedly preset<strong>handpiece</strong> <strong>maintenance</strong>.End-of-Cycle IndicatorPress the start key. In less than two minutes,all <strong>handpiece</strong>s are <strong>correct</strong>ly cleanedand lubricated.(When one long mode and two short modes are selected.)An audible indicator alerts the operator when the cycle is completed.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!