13.07.2015 Views

ISOLA IS410

ISOLA IS410

ISOLA IS410

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Technical Values<strong>IS410</strong>Specification Sheet #: IPC-4101A/24Reinforcement:woven E-glassResin system:primary: epoxy • secondary: multifunctional epoxyFlame Retardant Mechanism: brominated epoxy resin • minimum UL requirement: V-1Fillers:noneID Reference:UL/ANSI: FR-4 • ANSI: FR-4/24Glass Transition (T g ): 150 °C - 200 °CExplanations:C = preconditioning in humidity chamberE = preconditioning at temperatureThe figures following the letter symbols indicatewith the first digit the duration of the preconditioningin hours, with the second digitthe preconditioning temperature in °C andwith the third digit the relative humidity.PropertiesUnitsLaminate thickness < 0.50 mm Laminate thickness ≥ 0.50 mmSpecification Isola-Value Specification Isola-Value1. Peel Strength, minimumA. Low profile copper foil andprofile copper foil – all copperweights > 17 µm N/mm 0.70 n/a* 0.70 n/a*B. Standard profile copper foil (35 µm)1. After thermal stress N/mm 0.80 1.07 1.05 1.512. At 125 °C N/mm 0.70 0.87 0.70 1.363. After process solutions N/mm 0.55 1.10 0.80 1.68C. All other foil composite N/mm n/a* n/a* n/a* n/a*2. Volume Resistivity, minimumA. C-96/35/90 MΩ · cm 1.0 · 10 6 6.0 · 10 7 n/a* n/a*B. After moisture resistance MΩ · cm n/a* n/a* 1.0 · 10 4 3.4 · 10 7C. At elevated temperature E-24/125 MΩ · cm 1.0 · 10 3 4.0 · 10 7 1.0 · 10 3 3.8 · 10 73. Surface Resistivity, minimumA. C-96/35/90 MΩ 1.0 · 10 4 9.0 · 10 7 n/a* n/a*B. After moisture resistance MΩ n/a* n/a* 1.0 · 10 4 2.0 · 10 7C. At elevated temperature E-24/125 MΩ 1.0 · 10 3 6.0 · 10 7 1.0 · 10 3 3.8 · 10 74. Moisture Absorption, maximum % n/a* n/a* 0.80 0.20**5. Dielectric Breakdown, minimum kV n/a* n/a* 40 546. Permittivity @ 1 MHz, maximum(Laminate or prepreg as laminated) 5.4 4.5 - 4.9 5.4 4.87. Loss Tangent @ 1MHz, maximum(Laminate or prepreg as laminated) 0.035 0.020 0.035 0.0188. Flexural Strength, minimumA. Length direction N/mm 2 n/a* n/a* 415 592B. Cross direction N/mm 2 n/a* n/a* 345 5349. Flexural Strength @ Elevated Temperature,length direction, minimum N/mm 2 n/a* n/a* n/a* n/a*10. Thermal Stress at 288 °C, minimumA. Unetched s ≥ 10 ≥ 10 ≥ 10 ≥ 10B. Etched s ≥ 10 ≥ 10 ≥ 10 ≥ 1011. Electric Strength, minimum(Laminate or prepreg as laminated) kV/mm 30 36 n/a* n/a*12. Flammability class V-1 V-0 V-1 V-013. Glass Transition Temperature (T g ) DSC °C 150 - 200 170 - 180 150 - 200 170 - 18014. Coefficient of Thermal Expansion (CTE) TMAFill direction (below T g / above T g ) ppm/K – – – 17/15Warp direction (below T g / above T g ) ppm/K – – – 13/6Vertical (below T g / above T g ) ppm/K – – – 55/217Tests are carried out in accordance with IPC-650 test methods.*not applicable **measured at 1.55 mm laminateOur information and our eventual advice for the application of our products in any form (for instance oral,written or by tests) is given carefully and by the best of our knowledge but is not binding and is providedwithout making any representation or warranty, expressed or implied, and without any liability. The useris not released also in the case of our prior testing or if the use is based on our practical applicationadvice from it’s sole responsibility to use our product and to insure the correct application, the conditionand fitness of our product for this application as well as the condition and fitness of the product itself.USA EUROPE ASIA10/05 · 09101053Isola USA Corp.3100 W. Ray Road, Suite 301Chandler, AZ 85226, USAPhone: +1/4 80 / 8 93 65 27Fax: +1/4 80 / 9 17 51 92E-mail: info@isola-usa.comIsola GmbHIsolastr. 252353 DürenGermanyPhone: +49 (0) 24 21/ 80 80Fax: +49 (0) 24 21/ 80 81 64E-mail: info-dur@isola-group.comIsola Werke UK Ltd.2, Wyndford RoadWardpark North Ind. AreaGB-Cumbernauld G68 OBAPhone: +44 / 12 36 / 81 11 00Fax: +44 / 12 36 / 81 11 01E-mail: info-cum@isola-group.comwww.isola-group.comMAS Italia s.r.l.Via S. Sebastiano 21I-51032 Bottegone (PT)Phone: +39 / 05 73 / 92 21Fax: +39 / 05 73 / 92 22 65E-mail: info-bot@isola-group.comIsola Asia Pacific (Taiwan) Inc.No. 915, Sec 2 Cheng Jung RoadKuang-Yin Industrial Zone (32821)Taoyuan Hsien · Taiwan, R.O.C.Phone: +8 86 / 34 83 - 70 00Fax: +8 86 / 34 83 - 70 30E-mail: asia@isola-group.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!