Variable Refrigerant Flow SystemMulti Air Conditioning System for BuildingsThe Intelligent Choicein ComfortSERIESN807All products specified in this brochure complywith the AustralianCommunications Authority's (ACA)requirements for ElectromagneticCompatibility (EMC).is a worldwide trademark of FUJITSU GENERAL LIMITED.FUJITSU brand lineup except for compact cassette (AU7 - 18) was certified by China Compulsory Certification.All specifications subject to change without prior notice.Distributed by :Copyright 2003-2007 Fujitsu General Limited. All rights reserved.1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, JapanURL : http://www.fujitsu-general.com2007.12.05 VB009E/09 Printed in Japan


TMHigh-performance air conditioning systemVariable Refrigerant Flow SystemThe compact VRF System provides economical and comfortable air conditioningfor wide range of applications from living space to business space.Piping materialCompact VRF System for use in apartments, homes, shops, officesHomesHomes need individual air conditioning control forspecific rooms that can also be easily switched tostandby mode if the occupants have to go out at shortnotice.Use the correct refrigerant piping and materials for R410A.For the pipe wall thickness, see the table below.Copper pipeoutside diameter( )MaterialCopper pipe 2)wall thickness (mm)Tools6.350.89.520.812.700.815.88CopperJIS H3300 C1220T-O or equivalent 1)Note: Always observe and follow the necessary local regulations when installing refrigerant piping.1) Allowable tensile stress >2= 33 (N/mm ); 2) Design pressure 4.2MPa.R410A work requires a number of special tools ( symbol).Since tools used in R22 work cannot be used, provide the tools separately.1.019.051.2ApartmentsThe common areas and individual room spaces inapartment blocks have differing air conditioning needs.What is required is an air conditioning system that providescomfortable conditions and is economical andsurroundings conscious.A range which allows an unlimited combination of indoor and outdoor units accordOutdoor unitsIndoor unitsHeat Pump R410A Cooling Only R410A Compact Cassette Cassette Compact DuctLow Static PressureDuctDuctTool namePipe cutterFlaring toolTorque wrench (1/2, 5/8)ExpanderPipe benderNitrogen gasWelderGauge manifoldCharging hoseVacuum pump(with adaptor)Electronic scale for refrigerant chargingGas leak testerWork precautionsRefrigerant checkRefrigerant piping workProcess and applicationPipe cuttingPipe flaring workFlare nut connectionRefrigerant piping workExpansion at pipe connectionPipe bending workPipe interior oxidation preventionAir tightness testPipe brazingVacuum evacuation and refrigerantcharging operation checkGas leakage testVacuum dryingRefrigerant additional chargingBefore work, check the refrigerant used and prepare materials matched to the refrigerant.DryNo water insideWaterAir tightness test ~Refrigerant additional chargingObserve the basics (dry, clean) of refrigerant piping and carryout work so that problems will not occur. Moreover, when performingwelding work, seal in nitrogen gas and perform work sothat an oxide film is not produced.CleanNo dirt insideDirtSlim TypeAU20 / AU25 / AU30Leak pressure testConduct a pressure test sufficiently and make sure there is no refrigerant leakage.AJA54L/AO54UAJA54J/AO54FAU7 / AU9 / AU12 /AU14 / AU18AU36 / AU45 / AU54AR7 / AR9 AR12 / AR14 /AR18 / AR22Silent ModelARXB25 / ARXB30AR25 / AR30 /AR36 / AR45Vacuum dryingIf the vacuum pump does not have a reverse flow check mechanism, use the pump togetherwith a reverse flow check adapter.P4, P5 P14P15P16P17P17Additional refrigerantCharge only the amount of R410A refrigerant calculated in the additional refrigerant chargecalculation. This refrigerant should ony be charged in a liquid form.227


TMHigh-performance outdoor unit delivering comTMSERIESOptional PartsEV kitUTR-EV2AXLUTR-EV3XLEV kit is available for installationas necessary.Model code 30 : UTR-EV2AXLModel code 30 : UTR-EV3XLSeparation tubeUTR-BP054X / UTR-BP54USeparation tubes are availablefor installation as necessary.Variable Refrigerant Flow SystemR410AHeat PumpAJ*A54LCLRAO*54UJBMRCooling OnlyAJ*A54JCLRAO*54FJBMRAJ*A: AJYA (FUJITSU) AJ*A: AJGA (GENERAL)AO* : AO (FUJITSU) AO* : AOG (GENERAL)Grille kitUTG-UDYD-WUTG-UDGD-WGrille for compact cassettetype indoor unit.HeaderUTR-HD546UHeaders are available for installationas necessary.<strong>Remote</strong> sensor unitAir clean filterUTD-RS100UTR-FA08Powerful operation with low electricity consumptionThermo sensor for sensing thetemperature of an arbitraryplace in the roomFor wall mounted typeAir clean filter assembly for initialsetting.Excellent COPs are attainable asshown in the table below.Cooling COPHeating COP3.203.40Uses a high-performance DC inverterscroll compressor with variablecapacity according to the load duringcooling and heating.Flange (Square)UTD-SF045TAir clean filterUTR-FB03* COP is the coefficient of performance( capacity (kW) input power (kW)).COP values are base on our own testing method.For duct type205 x 1,063, L=40 (mm)Replacement filter forUTR-FA08High-capacity connection possibleOne outdoor unit can connect to up to 8 indoor units.Connectable capacity is 150% of the outdoor unitrating and can cope with a range of operating modes.Max 8indoor unitsconnectableIndoor unitconnectablecapacity150%When all indoor units are operating at maximum capacity, individual indoorunits operate at slightly lower capacity when connecting more than 100%.Operating outside air temperature rangeOutdoor unit operatesover an ambient temperaturerange of -5 Cto 43 C for cooling and-20 C to 21 C for heating.50403020100-10Cooling43 C-5 CHeating21 C-20 CFlange (Round)UTD-RF204For duct type195 ( 205), L=85 (mm)Long-life filterUTD-LF270For duct type425


TMTMVariable Refrigerant Flow SystemAccessoriesWireless <strong>Remote</strong> <strong>Controller</strong>IR Receiver Unitfort and economySupplied with each indoor unitIR receiver unit is connectedfor each duct type indoor unit.Lightweight and compact designSmall, compact casing can be easily concealed.DimensionsLow height and lightweight designH900 x W900 x D370mmOptional PartsGroup <strong>Remote</strong> <strong>Controller</strong>Network Converter900900mm1,152mm900mmUTB-YDB / UTB-GDBUp to 8indoor units can becontrolled by a single controller.When air conditioner ON/OFFand temperature setting arepreset automatically by usinga weekly timer, operation canbe started and stopped automatically.Wired <strong>Remote</strong> <strong>Controller</strong>UTB-YUB / UTB-GUBUTB-TUBWired remote controller capableof controlling each indoorunit individually.Can be used together withwireless remote controller.7SU MO TU WE TH FR SA3 6 9 12 15 18 21<strong>Simple</strong> <strong>Remote</strong> <strong>Controller</strong>UTB-YRA / UTB-GRAUTB-TRAUTR-YGCANetwork converter is requiredto connect Group <strong>Remote</strong><strong>Controller</strong> to an VRF system.<strong>Simple</strong> <strong>Remote</strong> <strong>Controller</strong>UTB-YPB / UTB-GPBUTB-TPBConcentrates on basicoperations such as On/Off,Fan Control, Master Controland Temperature Setting.External Switch <strong>Controller</strong>UTR-YESA900 370Noise reduction(Unit: mm)The low overall height allowsthe unit to be neatly positionedbeneath a window.Newly designed larger fan and double casing bellmouth construction reduce noise emissions.Large fanLow-speed designsuppresses noise by usinga larger fan.120kgConventional type15.2kW single type97kg15.2kW VRFBlue fin heat exchanger mountedCorrosion-resistance of the heat exchangereven in coastal areas has been improved byblue fin treatment of the outdoor unit heatexchanger.Blue fin heat exchangerCobalt Blue protectionStandard chromate protectionAluminium base materialHydrophilic coating*Cobalt blue protection (Blue Fin) is a standard specification ofAJ*A54LCLR, AJ*A54JCLR.SERIESConcentrates on basicoperations such as On/Off,Fan Control and TemperatureSetting.Switching of the air conditionercan be controlled byconnecting other sensorswitches.Double casing bell mouthDouble casing bell mouth helpsto reduce noise.245


50 500TMCompact VRF System allows design flexibVariable Refrigerant Flow SystemFlexible design Superior design flexibility allows individual airconditioning of multiple rooms.System that allows individual air conditioning of multiple roomsHomesShopsOfficesIndoor unit Compact DuctModels: AR7 / AR9 / AR12 / AR14 / AR18 / AR22*Service accessibility must be allowed for when installing the product.Please consult the installation manual for the necessary service access size.576390Bolt Pitch1664886 (597)Bolt Pitch100or more11300 or more22605575Control box(Unit : mm)( ) : AR7 / AR9Service hole2119437585364Indoor unit Low Static Pressure Duct / DuctModels: ARXB25 / ARXB30AR25 / AR30 / AR36 / AR45*Service accessibility must be allowed for when installing the product.Please consult the installation manual for the necessary service access size.138 264 264 2648275202294ø200(Knock out hole)700586 - 62613839Bolt pitch118 - 158ø205P.C.D. ø225Bolt Pitch 1176Outlet60021(Unit : mm)27097 582913220232492024341094Outlet850 (560)920 (630)600 (400)478520Brackets10150Brackets51181423836P.C.D. ø2251063113511751210300206 32Service holeControl boxPiping connection examples217150Air flow outletControl boxSeparation tube systemSeparation tubeEV kitSeparation tube + header systemSeparation tubeHeaderEV kitRefrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Refrigerant piping flare connection (Gas)4 Drain piping connection (Drain pipe : I.D. 21.5 O.D. 26.0)4 Drain piping connection (Drain pipe : I.D. 35.7 O.D. 38.1)Easier outdoor unit installationDiscreet installationThe compact dimensions allow the outdoor unit to beinstalled below a window.Large capacity connectableMax 8Indoor unitsconnectable900mmHeight 900Width 900Depth 370Unit: mmUp to 8 indoor units can be connected to 1 outdoorunit. Furthermore, the indoor unit connectioncapacity can be up to 150% of the outdoor unitrating. This increases design flexibility.150%ConnectablecapacityLong piping lengthThe maximum piping length is 70m, and can copewith a wide range of applications from homes tooffices.Actual pipe length : 70m max.Note: *1Height difference betweenO.U.and I.U. : 30m max.*1Height difference betweenI.U.and I.U. : 15m max. forAJ*A54LCLR, AJ*A54JCLRHeight difference between I.U. and I.U. : 5m max.for AO*54UJBMR, AO*54FJBMR.All indoor units are supplied with aremote controllerAll indoor units come with a wireless remotecontroller.Note: IR receiver unit is available for duct type indoor unit.Indoor unit Compact Wall MountedModels: AS7 / AS9 / AS12 / AS1425750or more2300or more50or more(Unit : mm)808 187690499546Indoor unit Wall MountedModels: AS18 / AS24 / AS3060 or more 1500 or more 60 or moreRefrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection(Drain hose : I.D. 12 O.D. 16.2-17 L 62031550or more2300or more1120 235593691721Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection(Drain hose : I.D. 17 O.D. 24 L670)50or more1500 or more(Unit : mm)623


7SU MO TU WE TH FR SA3 6 9 12 15 18 217SU MO TU WE TH FR SA3 6 9 12 15 18 21TMDimensionsility and efficient operationVariable Refrigerant Flow SystemOutdoor unit(Unit : mm)Models: AJA54L / AO54U / AJA54J / AO54F123Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Check valveEasy installation Quick and easy to install.Easy to understand piping and wiring installationThe wiring work is simple in the connection wiring system one by one.The dedicated communication line is unnecessary.The electrical work is simple because of single-phase power supply.900System diagramRefrigerant pipingSeparation tubeEV kitPower sourcePower source/signal lineOutdoor unitIndoor unit900715.2Networkconvertor3979373Group<strong>Remote</strong> <strong>Controller</strong><strong>Simple</strong><strong>Remote</strong> <strong>Controller</strong>Wired<strong>Remote</strong> <strong>Controller</strong>+Wireless<strong>Remote</strong> <strong>Controller</strong>Wireless<strong>Remote</strong> <strong>Controller</strong>Wired<strong>Remote</strong> <strong>Controller</strong><strong>Simple</strong><strong>Remote</strong> <strong>Controller</strong>+Wireless<strong>Remote</strong> <strong>Controller</strong>Indoor unit Compact CassetteModels: AU7 / AU9 / AU12 / AU14 / AU18(Unit : mm)230Indoor unit CassetteModels: AU20 / AU25 / AU30 (Slim type)AU36 / AU45 / AU5430(Unit : mm)( ) : AU20 / AU25 / AU30296 (245)System addressingDuring installation work, system addressing canbe performed using the wireless remote controller,thus eliminating manual switch setting.Easier installation of the outdoor unitCompact size and lightweight650570Power source/signal lineOutdoor unitIndoor unit900650 570940750(Grille measurement)650(Hanging bolt position)40012Wireless<strong>Remote</strong> <strong>Controller</strong>900 370(Hanging bolt position)6062454686126111600(Ceiling opening measurement)34041245285603940298305 2481 2120 (70)150 (100)25060750298305 248120 (70)150 (100)Weight97kg(Unit: mm)The outdoor units is light and compact and easy tohandle during installation.1 Refrigerant piping flare connection (Liquid)2 Refrigerant piping flare connection (Gas)3 Drain piping connection(Drain pipe : I.D. 32 O.D. 37)1 Refrigerant piping flare connection (Liquid)2 Refrigerant piping flare connection (Gas)3 Drain piping connection (Drain pipe : I.D. 32 O.D. 37)227


SU MO TU WE TH FR SA73 6 9 12 15 18 21SU MO TU WE TH FR SA73 6 9 12 15 18 21TM8Control system that always provides apleasant air conditioned environmentFive types of controllers are available to meet the varied needs of the building and the user. Tighter control overthe air conditioned environment can be achieved by combining group remote controller which can operate all theindoor units at the same time, a wired remote controller with a weekly or daily schedule, a wireless remotecontroller and a simple remote controller.Wireless controlConveniently positioned and easilyoperated, with full timer functions.Schedule controlIndoor units can be controlled ona weekly or daily schedule.*AS7/AS9/AS12/AS14 are only availablefor wireless remote controller.System diagramPower sourceOutdoor unitRefrigerant pipingPower source/signal lineNetworkconvertorGroup<strong>Remote</strong> <strong>Controller</strong>Indoor unit<strong>Simple</strong><strong>Remote</strong> <strong>Controller</strong>Separation tubeWired<strong>Remote</strong> <strong>Controller</strong>+Wireless<strong>Remote</strong> <strong>Controller</strong>EV kitWireless<strong>Remote</strong> <strong>Controller</strong>Indoor units can be controlled asa group which is convenient whenentering or leaving the building.Program On/Off controlEconomic use of the air conditioningcan be achieved by usingprogrammed on/off control.<strong>Simple</strong> operation controlMinimum necessary functionswith simple operation.Easy to understand and use.Wired<strong>Remote</strong> <strong>Controller</strong>Group control<strong>Simple</strong><strong>Remote</strong> <strong>Controller</strong>+Wireless<strong>Remote</strong> <strong>Controller</strong>Indoor unitCompact DuctLow StaticPressure Duct DuctModel codeAR7 AR9 AR12 AR14 AR18 AR22 ARXB25 ARXB30 AR25 AR30 AR36 AR45Model nameARXA07 ARXA09 ARXA12 ARXA14 ARXA18 ARXA22 ARXB25 ARXB30 ARY25 ARY30 ARY36 ARY45LALR LALR LALR LALR LBLR LBLR LATR LATR UFAAR UFAAR UFAAR UFAARPower source220-240V, 50HzkW 2.15 2.80 3.50 4.00 5.30 6.00 7.05 8.80 7.05 8.80 10.5 12.7Cooling capacityBTU / h 7,300 9,600 11,900 13,700 18,100 21,100 24,100 30,000 24,100 30,000 36,000 43,500kW 2.45 3.10 4.10 4.80 5.60 6.30 7.85 9.10 7.85 9.10 10.7 13.7Heating capacityBTU / h 8,400 10,600 14,000 16,400 19,100 21,500 26,800 31,000 26,800 31,000 36,500 47,000Input powerW32 49 103 77155155315CurrentA0.20 0.24 0.45 0.360.700.681.44Maximum current0.24 0.29 0.54 0.400.840.841.84Heat exchangerPlate fin coilHigh420 620 950 8901,3401,2002,200Air circulation Med m 3 / h 390 550 790 7801,0901,1002,000Low360 470620 6709701,0001,800Recommend static pressure Pa0 to 40 0 to 8030 to 160 30 to 180Fan type x numberSirocco x 1Sirocco x 2Fan motor outputW10 14 52 3647 77275High343340 42334449Noise level(sound pressure)Med dB (A) 322935 38294247Low312730 34264045Air filterPP monofilament net (Antibacterial / Deodorization)Filter : UTD-LF270 (Option)PP honeycomb net, Fungicide TypeDimensions Net217 x 663 x 595217 x 953 x 595270 x 1,210 x 700mm(H x W x D) Gross 324 x 785 x 686324 x 1,075 x 686300 x 1,300 x 790Net18254345WeightGrosskg22295355Liquid6.35 6.35 9.52 6.359.52Diameter mmPipe sizeGas9.52 12.70 15.88 19.05Connection methodFlareDrain pipe materialDia. (mm)ABS/Outer diameter 26mm / Inner diameter 21.5mmNote: Specifications are based on the following conditions.Cooling: Indoor temperature 27 CDB/19 CWB, and outdoor temperature 35 CDB/(24 CWB).Heating: Indoor temperature of 20 CDB/(15 CWB), and outdoor temperature 7 CDB/6 CWB.Standard static pressure: 0Pa (AR7 to AR22, ARXB25, ARXB30), 100Pa (AR25 to AR45).Voltage: 230 [V]Indoor unitModel codeModel namePower sourceCooling capacityHeating capacityInput powerCurrentMaximum currentHeat exchangerAir circulation MedLowFan type x numberFan motor outputNoise level(sound pressure)Air filterCasing colorWeightPipeDrain pipe materialHighHighMedLowDimensions Net(H x W x D) GrossNetGrossLiquidDiameter mmGasConnection methodDiameter(mm)kWBTU / hkWBTU / hWAm 3 / hWdB (A)mmkgAS7AS*7UFADRCompact Wall MountedAS9AS12AS*9AS*12UFADR UFADRNote: Specifications are based on the following conditions.Cooling: Indoor temperature 27 CDB/19 CWB, and outdoor temperature 35 CDB/(24 CWB).Heating: Indoor temperature of 20 CDB/(15 CWB), and outdoor temperature 7 CDB/6 CWB.Voltage: 230 [V]AS14AS*14UFADRFlareSteel/Outer diameter 38.1mm / Inner diameter 35.7mmAS18AS*18UFAJRAS* : AS (FUJITSU), ASG (GENERAL)Wall MountedAS24AS30AS*24UFAJRAS*30UFAJR220-240V, 50Hz2.157,4002.458,4002.809,6003.1010,6003.5011,9004.1014,0003.8013,0004.5015,4005.4018,4005.6019,1006.9023,6007.8026,6008.0027,3008.8030,0002633403850600.150.170.210.180.240.280.180.210.240.220.290.34Plate fin coil4105005408409501,050370450510700800940350410480600670780Cross flow x 113 38303639424548273337394145263034353741PP honeycomb (Antibacterial and Mold proofing)PP monofilament net (Deodorization, Anti-mold)WhiteWhite257 x 808 x 187320 x 1,120 x 220270 x 850 x 310348 x 1,240 x 42781610226.35 9.529.52 12.7015.88With 620mm drain hose, PVC / Outer diameter16.2-17mm / Inner diameter 12mmVariable Refrigerant Flow SystemWith 670mm drain hose, PVC / Outerdiameter 24mm / Inner diameter 17mmAR7 / AR9AR12 / AR14AR18 / AR22ARXB25 / ARXB30Silent ModelAR25 / AR30AR36 / AR45AS7 / AS9 / AS12AS14AS18 / AS24 / AS3021


TM20SpecificationsOutdoor unitModel namePower sourceCoolingCapacityHeatingCoolingInput powerHeatingMaximum currentCoolingCOPHeatingHeat exchanger finAir circulationFan type x NumberFan motor outputNoise levelNormal operation mode(sound pressure) Silent operation modeTypeCompressorDriving methodMotor outputRefrigerantRefrigerant oilCasing colorNetDimensions (H x W x D)GrossNetWeightGrossSafety devicesCoolingOperation rangeHeatingDiameter Liquid / GasPipe Max length / Max height differencePipe connection methodConnectable indoor unitsConnectable indoor unit capacitym 3 / hNote: Specifications are based on the following conditions.Cooling: Indoor temperature 27 CDB/19 CWB, and outdoor temperature 35 CDB/(24 CWB).Heating: Indoor temperature of 20 CDB/(15 CWB), and outdoor temperature 7 CDB/6 CWB.Voltage: 230 [V]Indoor unitModel codeModel namePower sourceCooling capacityHeating capacityInput powerCurrentMaximum currentHeat exchangerAir circulationFan type x numberFan motor outputNoise level(sound pressure)Air filterFUJITSU grille colorGENERAL grille colorWeightDrain pipe materialHighMedLowHighDimensions Net(H x W x D) GrossNetGrosskWBTU / hkWBTU / hWAm 3 / hWMed dB (A)LowmmkgLiquidDiameter mmPipe sizeGasConnection methodDia. (mm)AU7AU7UFAARNote: Specifications are based on the following conditions.Cooling: Indoor temperature 27 CDB/19 CWB, and outdoor temperature 35 CDB/(24 CWB).Heating: Indoor temperature of 20 CDB/(15 CWB), and outdoor temperature 7 CDB/6 CWB.Voltage: 230 [V]kWAWdB(A)WmmkgCmmm2.15 2.807,400 9,6002.45 3.108,400 10,600280.130.15530480410Corrosion-resistance (Blue fin)5,250Propeller x 11505651ScrollDC inverter3,000R410ASynthetic oil (POE oil)BeigeAJ*A : AJYA (FUJITSU), AJ*A : AJGA (GENERAL)AO* : AO (FUJITSU), AOG (GENERAL)AJ*A54LCLR AJ*A54JCLR AO*54UJBMR AO*54FJBMRCompact CassetteAU9AU9UFAARAU12AU12UFAAR3.6012,3004.1014,00023Single-phase, 220-240V, 50Hz15.216.6 - 16.6 -4.754.88 -4.88 -3.20 3.203.40 -3.40 -900 x 900 x 3701,021 x 1,026 x 43697112-5 to 43-20 to 21 --20 to 21520.230.27580520460938104135 3731 34230 x 570 x 570280 x 710 x 75018PS / Outer diameter 37mm / Inner diameter 32mm70 / 30FlareMaximum 850% to 150%Hydrophilic coatingFan motor thermal protector, High pressure switch, Low pressure switch, FuseAU14AU14UFAAR4.0013,7004.5015,400White (UTG-UDYD-W : Option)White (UTG-UDGD-W : Option)9.5212.7030, 25, 20, 15 (The ranges can be selected by setting DIP switch)6.35AU18AU18UFAAR5.0017,1005.4518,600500.220.26640540470154435220-240V, 50Hz5.7019,5005.8019,8001170.760.91Plate fin coil381,030850680Turbo x 19.52 / 19.05PP honeycomb net (Anti-mold)Flare-AU* : AU (FUJITSU), AUG (GENERAL)CassetteAU20 AU25 AU30 AU36 AU45AU*20UFARR37427.0524,1007.8526,8001290.800.961,170970770421420.841.001,2701,0708804540 4239 39246 x 830 x 830385 x 1,045 x 1,015344515.88AU*25UFARRAU*30UFARR8.8030,0009.1031,100WhiteAU*36UFASR10.535,80010.736,5001750.921.101,5001,3001,100AU*45UFASR12.743,40013.746,8001900.941.121,6501,4501,2009048 4944 4741 43296 x 830 x 830435 x 1,045 x 1,01540539.5219.05ABS / Outer diameter 37mm / Inner diameter 32mmAU54AU*54UFASR14.148,10015.853,9002190.951.141,7801,5501,300524945AJ*A54LAO*54UAJ*A54JAO*54FAU7 / AU9 / AU12AU14 / AU18AU20 / AU25 / AU30AU36 / AU45 / AU54Slim TypeGroup remote controllerwhich can operate all the indoor unitsGroup <strong>Remote</strong> <strong>Controller</strong>UTB-YDB / UTB-GDB [Option]Group control of indoor units with simple operationUp to 8 indoor units can be controlled with a single controller.Network Convertor (UTR-YGCA) is required to connect Group<strong>Remote</strong> <strong>Controller</strong>s to an VRF system.High performance and compact sizeON/OFF, master control, set temperature and airflow can be controlled / monitored centrally orindividually.CentralcontrolUp to 8 indoorunits can becentrallycontrolled.ON/OFFcontrolSystem configurationGroup/individual control of up to 8 units ispossible with a single controller.Outdoor unitSpecificationsModelPower SupplyDimension(mm)Weight (g)NetworkconvertorGroup remotecontrollerUp to 8 indoor unitscan be individuallycontrolled.IndoorunitHeightWidthDepthWeeklytimerTwo ON/OFFtimes can be setfor each day of theweek.<strong>Simple</strong> <strong>Remote</strong><strong>Controller</strong>Wired <strong>Remote</strong><strong>Controller</strong>Wireless <strong>Remote</strong><strong>Controller</strong>Built-in weekly timersThe weekly timer is provided as a standardfunction.1. The timer can be set up for up to 4 times perday. (On / Off, master control, set temperature)2. Allows separate settings for each day of theweek.ON/OFF switchingOpe.Temperature switchingStop settingGroup <strong>Remote</strong> <strong>Controller</strong>UTB-YDB/UTB-GDBDC 12V12012017200TimeAir conditioning ON/OFF settingcorresponding to air conditioningspecification needs is possible.(Peak cut)Ope.TimeSince peak power cut is performedin a planned way, setting whichchanges the room temperaturelinked with time is possible.Ope.Variable Refrigerant Flow SystemTimeCooling / HeatingswitchingOpe.TimeSwitching between thecooling mode and heatingmode can be set by time.(Anti-freeze)Ope.TimeLow temperature heatingoperation can be set toprevent freezing in coldregions at night, etc.Indoor unit start/stop matched tothe air conditioning operation endtime is possible.Network ConvertorUTR-YGCA [Option]220-240V 50-60Hz863132161,9009


7SU MO TU WE TH FR SA3 6 9 12 15 18 21TMA controller can be chosen according to usercomfortable, easily adjustable air flowVariable Refrigerant Flow SystemWired <strong>Remote</strong> <strong>Controller</strong>UTB-YUB / UTB-GUB / UTB-TUB [Option]Weekly timer and timer function are easily operated.Dimensions (H x W x D) 120 x 120 x 177SU MO TU WE TH FR SA3 6 9 12 15 18 21Wall MountedAS*18UFAJR AS*24UFAJR AS*30UFAJRPowerful features and compact size<strong>Simple</strong> installationWireless<strong>Remote</strong> <strong>Controller</strong>Wired remote controller, Weekly timer and Setback timerfunctions are combined in one compact unit.<strong>Remote</strong>controlWeeklytimerSetbacktimerComponents are compatible with standardswitch boxes. Flat back construction allowsequipment to be installedwherever it is needed. JIS built-in boxFeatures<strong>Remote</strong> controller operationcombined with easy-to-read LCDand with frequently used buttonsarranged to be easy to use.Two ON/OFFtimes can be setfor each day of theweek.Allows the user to settemperatures for two timespans over the course ofeach day of the week.Accurate and ComfortableEuropeanmounting boxPleasant multi-air flowEffective air flow within a room is achieved by the uniqueoperation of the power diffuser. The angle of the louvre canbe adjusted in six steps to give draught-free air flow.Symmetrical designIndoor temperature can bedetected accurately becausea thermo sensor has beenadded in the body of thewired remote controller.The detecting point in theroom can be freely changedwith the new type wiredremote controller (thermosensor added) and remotesensor (Option).Thermo sensor displaySensorControl button for changing the thermo sensor<strong>Remote</strong> Sensorin the bedroom(valid at night)<strong>Remote</strong> controllerin the living room (valid during the day)[ Example of changing sensor ]Wired <strong>Remote</strong><strong>Controller</strong>DayTHERMOSENSORNight<strong>Remote</strong>SensorThe detecting point can be freely changed.Wide air flow realized by unique operation of the power diffuserCoolingSwing123456HeatingLarge independentlydrivenpower diffuser6-stepHorizontal concentrationand other air directioncontrolWide aieflow with super vaneEasy-to-read center display<strong>Simple</strong> <strong>Remote</strong> <strong>Controller</strong>UTB-YPB / UTB-GPB / UTB-TPB [Option]UTB-YRA / UTB-GRA / UTB-TRA [Option]<strong>Simple</strong> remote controller concentrating on basic operations.Dimensions (H x W x D mm) 120 x 75 x 1412345Swing66-stepStepWarm air reaches everySwingVertical and horizontal symmetrical designmatched to the interior decor<strong>Remote</strong>controlBacklightLCD*1 *2<strong>Simple</strong> operation*1: <strong>Remote</strong> control with the minimum required operation buttons.*2: A simple LCD with the background lighted.A large Start/Stop button is provided in the centreof the remote controller unit for easy operation.The backlight is lit during button operations, and for10 seconds longer in the operation mode and5 seconds longer in the stop mode.FunctionsModelOperationOn/OffFan controlMaster controlTemp. settingUTB-YPB / UTB-GPB /UTB-TPBUTB-YPBUTB-GPBUTB-TPBUTB-YRA / UTB-GRA /UTB-TRAWithout master controlUTB-YRAUTB-GRAUTB-TRAOther functionsOther features include the functions of the existing wallmounted type.2-way draining route Double auto swingOptional partsAir clean filter (UTR-FA08)Easy installationLarger space at base of housing means an extra 15% ofpiping space.Increases pipingspace by 15%1019


SU MO TU WE TH FR SA73 6 9 12 15 18 21TMAttractive wall-mounted unit that delivers aneedsVariable Refrigerant Flow SystemCompact Wall MountedAS*7UFADR AS*9UFADR AS*12UFADR AS*14UFADRWireless<strong>Remote</strong> <strong>Controller</strong>Wireless <strong>Remote</strong> <strong>Controller</strong>[Accessory]Four kinds of timers. Easy operation.Wireless remote controller is an accessory of all indoor units.An IR Receiver Unit necessary for operation by accessorywireless remote controller is connected to Duct type indoor unit.Dimensions (H x W x D mm) 158 x 56 x 20<strong>Remote</strong>control<strong>Remote</strong> controller operation combinedwith easy-to-read LCD and with frequentlyused buttons arranged to be easy to use.ONtimerAt the set time,air conditioneroperation starts.OFFtimerAt the set time,air conditioneroperation stops.ProgramtimerSleeptimer*1 *2Features*AS7/AS9/AS12/AS14 are only available for wireless remote controller.Built-in daily timerSymmetrical designSymmetrical, clean design that suits all interiors.Compact sizePowerful output in spite of small sizeThough the indoor unit is compact, it features a large, highpressure cross fan (90mm diameter) in a centre mountedconfiguration and a Lambda type heat exchanger to provideplenty of power.Height 257Width 808Auto swing louvreThe Auto Swing Louvre function ensures that the airdirection corresponds to the mode selected.Cooling : 3-step (1 - 3)Heating : 6-step (1 - 6)StepSwingSwing*1 : Heating only *1123SwingSelect from 4 different timer programs : On / Off / Program / Sleep*1: Program timer / The program timer operates the ON and OFF timer oncewithin a 24 hour period.*2: Sleep timer / The sleep timer function automatically corrects the settemperature according to the time setting to prevent excessive cooling or heatingduring sleep hours.Cooling operation /dry operationWhen the sleep timer is set, the settemperature automatically rises 1 C everyhour. The set temperature can rise up to amaximum of 2 C.Heating operationWhen the sleep timer is set, the settemperature automatically drops 1 C every 30minutes. The set temperature can drop to amaximum of 4 C.60min.1 CTimer setting1 C2 C3 C30min.60min.90min.Timer setting4 C2 C<strong>Simple</strong> operationMixed-upAfter code changeA B C DA B C DCode selector switch prevents units from beingwrongly switched. (Up to 4 codes can be set.)Wide and precisetransmitting range.Depth 187Unit: mmWashable open panelCleaning the washablepanel removes mould anddust.A regular wipe with a drycloth keeps the casingclean.External Switch <strong>Controller</strong>UTR-YESA [Option]On/Off, Temperature, Fan control, and Master control can be switched in combinationequipped with the Card-key switch or sensor switch.Switching of the air conditioner can be controlled by connecting other sensor switches.*Card-key and other sensor switches are available as field supplied parts.Dimensions (H x W x D mm) 120 x 75 x 30Low noiseFan speedHIGHLOW*AS7 model datadB (A)3026Since the panel is removedand easily washed, it isalways clean.Filter cleaning is alsosimple.45611Room temp.Installation exampleAuto mode operation, which switches the cooling and the heating auto-matically,is enabled by using the sensor switch and external switch controller.In that case, all indoor units run in the same operation mode.T1T2HeatingCoolingTimeNote 1.Please choose a thermosensor switchwhich can be set up for T1 and T2.Note 2.The remote controller's operation isprior to the auto mode operation.Sensor SW(Field supplied)T1 = ON, T2 = OFFTo individual dry contactUp to8 indoor unitsExternal switch controller(UTR-YESA)18


Select to match the capacity and type of the roomvery low ceilingsVariable Refrigerant Flow SystemIndoor unit line up7 types 30 models, ranging from 2.15kW to 14.10kW.Capacity range (kW) 2.15 2.83.64.05.3TypeModel code 79121418Compact CassetteAU7UFAAR AU9UFAAR AU12UFAAR AU14UFAAR AU18UFAARP145.720Low Static PressureDuct Silent ModelARXB25LATR ARXB30LATRDuctAR25UFAAR AR30UFAARAR36UFAAR AR45UFAAR*Wireless remote controller and IR receiver unitis supplied with all duct type indoor units.Wireless<strong>Remote</strong> <strong>Controller</strong>IR Receiver UnitSlim TypeFeaturesCassetteLow static pressure duct typeDuct typeP15P16Silent ModelCompact DuctARXA07LALR ARXA09LALR ARXA12LALR ARXA14LALRARXA18LBLRAU*20UFARROptimum model for hotels or bedrooms26dBLow speedAn ultra low-noisemodel that achieves aquiet interior. Perfectfor hotels or bedroomswith limited air ductinstallation space.Installation stylesDirect air flow installation can be performed.Air intake system can also be chosen.Powerful model with a flexible designWith a powerful motor, appropriate for a widerange of static pressure.Max.Flexible air duct180Painstallation ispossible in alarge spacesuch as an office.Installation stylesEmbedded CeilingLow Static Pressure DuctP17Hanging from CeilingDuctP17Savings in space and easy installationTwo-direction drain pipingSlim compact design allows for easy installation innarrow ceiling space.P18Compact Wall MountedAS*7UFADR AS*9UFADR AS*12UFADR AS*14UFADR27cmDuctindoor unitWall MountedP19AU*: AUY(FUJITSU), AUG(GENERAL) AS*: ASY(FUJITSU), ASG(GENERAL)AS*18UFAJRSuspended InstallationHanger boltsDirect InstallationAnchor boltsOptional partsFlange (square)Flange (round)Long-life filter<strong>Remote</strong> sensor unitUTD-SF045TUTD-RF204UTD-LF270UTD-RS100Two-directiondrain piping1217


TMUltra-slim duct air conditioner for use withVariable Refrigerant Flow SystemCompact DuctARXA07LALR ARXA09LALR ARXA12LALRARXA14LALR ARXA18LBLR ARXA22LBLR*Wireless remote controller and IR receiver unitis supplied with all duct type indoor units.Wireless<strong>Remote</strong> <strong>Controller</strong>6.0226.9247.05258.83010.53612.74514.154AccessoriesWireless<strong>Remote</strong><strong>Controller</strong>IRReceiverUnitIR Receiver UnitSlim TypeSlim TypeFeaturesAU*25UFARR AU*30UFARR AU*36UFASR AU*45UFASR AU*54UFASRCompact and space-saving designUltra-slim unit simplifies installation.AR7 / AR9AR12 / AR14 / AR18 / AR22Low noise levelThese compact duct type units are extremely quiet.Model 7 9 12 14 18 22Static pressure(standard/max)Pa0 / 40Air flow volume(high/low)m 3 /h 420/360 620/470 950/620 890/670Noise level(Low speed)dB(A)31273034ARXA22LBLREasy installation (Universal type)Slim and compact dimensions allow for ceilinginstallation or floor standing.Two-direction drain pipingARXB25LATRARXB30LATRAR25UFAAR AR30UFAAR AR36UFAAR AR45UFAARPerfectly housed in ceiling space.Installation examplePerfectly housed in the spacebelow a window.Duct indoor unitTwo-direction drain pipingFilter (Accessory)ARXA07 / ARXA09 ARXA12 / ARXA14 / ARXA18 /ARXA22Filter(2pcs.)Filter(3pcs.)Optional parts<strong>Remote</strong> sensor unit UTD-RS100OthersAir intake from rear or bottom sideTwo direction drain pipingAS*24UFAJRAS*30UFAJR1613


TMSlim and compact cassette, designed for limited ceiling spaceVariable Refrigerant Flow SystemCompact CassetteAU7UFAAR AU9UFAAR AU12UFAARAU14UFAAR AU18UFAARCassetteSlim TypeAU*20UFARR AU*25UFARR AU*30UFARRCassetteAU*36UFASR AU*45UFASRAU*54UFASRComfortable air flow4-step swingAuto air flow directionand auto swing12344-step swing4 3 2 14-step swingSwingStep2~4 way air flow systemSelect 2-way, 3-way or 4-way air flow to suit your needs.2-way3-way4-wayFeaturesWireless<strong>Remote</strong> <strong>Controller</strong>Compact sizeCompact grille fits European ceiling panel(600mm x 600 mm).Punch hole grille650650Easy maintenance60057024520Unit: mmComfortable air flow4-step swing: Auto air flow direction and auto swing122-way34SwingStep2-4 way air flow system:Select 2-way, 3-way, or 4-way air flow to suit your needs.3-way43214-wayFeaturesFlexible installationWireless<strong>Remote</strong> <strong>Controller</strong>Compact body ensures space saving installation.A slender fit option is available where ceiling void spaceis limited.Standard settingHaSlender settingStandard setting Slender settingHaHbAU20 / AU25 / AU30 235 200AU36 / AU45 / AU54 285 250HbWide air flowUnit louvre distributes the outlet air flow further in thehorizontal direction.Duct connection hole openingFresh air can be introducedthrough this opening.Conditioned air can be distributed by means of a distribution duct.Two-wayDistributionductFresh airDistributionductOne-wayPlacing all the electrical components inside the unitensures easy maintenance.Wide opening foreasy maintenance.Detachable,washable filterand intake grille.Electrical component box(Built-in)Condensate pump lifts to 400mmExtremely quietLarge air flow at reduced noiseoutput achieved by incorporatinga large diameter variable pitchturbo fan.Draught preventionNormal positionFlap angle36 - 65Draughtpreventionposition7 blades fanThe angle of the flap can be changed during installation,thereby preventing uncomfortable draughts.Flap angle25 - 65298mmEasy maintenanceLong-life filterHigh efficiency,long-life filterextends thecleaning cycle.Long-lifefilter<strong>Simple</strong>maintenanceThe control box iseasy accessible formaintenance work.Detachable,washable filterand intake grille.Condensate pump lifts to 800mmImproved noise level and air distributionNoise output has been dramatically lowered.Improved turbo fan shape (aerodynamic design)Expanded air distribution Low internal resistanceMoulded fan motorDraught preventionThe angle of the flap can be changed during installation,thereby preventing uncomfortable draughts.Normal positionDraught prevention positionCeiling panel400mmOptional partsGrille kitUTG-UDYD-W, UTG-UDGD-WCeiling panel800mmFlap angle36 - 65Flap angle25 - 651415