13.07.2015 Views

technical specification for 11& 33 kv post insulators, 11 ... - WBSEDCL

technical specification for 11& 33 kv post insulators, 11 ... - WBSEDCL

technical specification for 11& 33 kv post insulators, 11 ... - WBSEDCL

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

WEST BENGAL STATE ELECTRICITY DIST. COM. LTD.Office of the Chief Engineer , Procurement & Contracts DepartmentVidyut Bhavan( 4th Floor),Bidhannagar, Block-DJ : Sector-IIKolkata-700 091 : Phone No.0<strong>33</strong>-2359-8397 : Fax No.0<strong>33</strong>-2359-1921Tender Specification, Type Test at the discretion of Ordering authority, shall have to bearranged by the successful contractor from any lot delivered to site, as per the relevantISS from any NABL accredited/Government recognized Test House or Laboratory inpresence of <strong>WBSEDCL</strong>‟S representative.However the necessary cost of the Type Test charges only be reimbursedto the party on production of necessary supporting documents.13.0 DOCUMENTS TO BE SUBMITTED AT THE TIME OF PHYSICAL DELIVERY AT CONSIGNEESTORESThe following documents to be submitted by the vendors to the consignee Stores at thetime of despatch to stores by the vendors:-a) Copy of Purchase Order.b) Copy of Despatch Instruction.c) Inspection Test Certificate.d) Guarantee Certificate.e) Pro<strong>for</strong>ma Invoice.f) Calculation Sheet <strong>for</strong> price Variation on the basis of IEEMA or CACMAI as applicablewith base date of order.g) Seal list and packing list.h) Challan, in triplicate.i) Way bill, if applicable.14.0 SPECIFIC TECHNICAL PARAMETERS14.1 PIN INSULATORS :Sl.No. Description Rating<strong>33</strong>KV<strong>11</strong>KV1. Nominal system Voltage <strong>33</strong> KV <strong>11</strong> KV2 Highest system Voltage : 36 KV 12 KV:3. Dia. of Largest shell : 280mm 165 mm4. Minimum failing load : 10 KN 5 KN5. P.F Vissible Discharge Voltage : 27 KVrms 09 KVrms6. P.F Minimum flash over voltagea) Dry : 130KVrms 75KVrmsb) Wet : 90KVrms 45KVrms7. Impulse flashover voltage1.2/50 micro second wave :a)Positive : 210KVp 95KVpb)Negative : 230KVp 100KVp8. P.F. Withstand Voltage :a)Dry : 95KVrms 60KVrmsb)Wet : 75KVrms 35KVrms9. Impulse withstand voltage 1.2/50micro second wave :a) Positive : 170KVp 75KVpb) Negative : 180 KVp 80 KVp10. Power Frequency puncture withstandvoltage: 180KVrms105KVrmsInsulator – Spec – Amended in March’2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!