PROGRAMMABLE ONOFF CONTROLLER<strong>X48A</strong>• Universal input• 0 / 1 / 2 / 3 setpoints• Isolated 0/4~20 mA or 0-10 V DCretransmission output• 24 V DC transmitter supply• RS485 / MODBUS RTU• 85~265 V AC SMPS• ONOFF controlSPECIFICATIONSAll specifications at ambient of 25 C, unless specified otherwiseCAT#179R5/P1/2/300611/AINPUTInput group 1ThermocoupleB, E, J, K, N, R, S, TRTDPt100, 3-wireVoltage0~50 mVCurrent0~20 mA, 4~20 mAInput group 2Thermocouple B, C, D, E, G, J, K, N, R, S, TRTDPt100, 3-wireVoltage0~50 mVCurrent0~20 mA, 4~20 mASquare rootTransmitter supply22 V nominal, 30 mA maxRange limits See Table 1Accuracy See Table 1Cold junction compensation AutomaticSensor break protection User programmableINDICATIONProcess variable Upper : 4 digit, 7 segment0.3” (7.6 mm) red LED displaySetpoint Lower : 4 digit, 7 segment0.3” (7.6 mm) green LED displayStatus indicationLEDs for relay statusOUTPUTSNo. of relays 0 / 1 / 2 / 3Relay contact typeNO-C-NC (RL1)NO-C (RL2, RL3)Relay contact rating5A / 230V AC, resistiveSSR drive12 V DC drive signal forexternal SSRCurrent output 4~20 mA / 0~20 mA / 20~4 mA /20~0 mA isolated from inputMaximum load for current 500 ohmsoutputVoltage output0~10 V / user specifiedLoad for voltage output >10 KohmsCOMMUNICATIONPortRS485ProtocolModbus RTUSlave ID User programmable (1~256)PROGRAMMABLEPARAMETERSSetpoint Full range (See Table 1)Unit°C, °F, EUResolutionUser selectable0.01, 0.1 or 1 for linear input,0.1 or 1 for temperatureHigh scale Full range (See Table 1)Low scale Full range (See Table 1)Digital filterA (minimum) ~ F (maximum)Hysteresis0~25% spanBias (for process variable) -50 to 50% of range limitRelay logica. Heatb. Coolc. Fullscale high alarmd. Full scale low alarme. Deviation high alarmf. Deviation low alarmg. Inband alarmh. Outband alarm(e. to h. available for SP2, SP3)Alarm typesSelf reset or latched and can bedisabled at power onAlarm acknowledgeFront panel function used toreset relay in alarm conditionSetpoint lockON, OFFLevel lockON, OFFRelay actionReverse / directOTHERProgrammingDimensions (in mm)MountingPanel cutoutSupply voltageThrough 3 tactile keys48(H) x 48(W) x100(D)Panel mount48 x 48 mma) 85~265 V AC, 50/60 Hzb) 20~35 V DC (optional)4 watts maximumPower consumptionOperating ambienttemperature 0~50 °CRelative humidityBelow 90%, non condensingwww.radix.co.in/ptc.htm


PROGRAMMABLE ONOFF CONTROLLER<strong>X48A</strong>TABLE 1SENSOR / INPUTInput Group 1Pt - 6% Rh / Pt - 30% Rh (B)Chromel / Constantan (E)Iron / Constantan (J)Chromel / Alumel (K)Nicrosil / Nisil (N)Pt / Pt - 13% Rh (R)Pt / Pt - 10% Rh (S)Copper / Constantan (T)Pt100, 3-wireLinear (0~50 mV, 0~20 mA, 4~20 mA)Input Group 2Tungsten - 5% Rh / Tungsten - 26% Rh (C)Tungsten - 3% Rh / Tungsten - 25% Rh (D)Tungsten / Tungsten - 26% Rh (G)RANGE LIMITS(°C / EU)LOW SCALE HIGH SCALEThe following inputs are available in Input Group 2 in addition to inputs of Input Group 1.400-270-210-270-27000-270-200-1999000182085076013721300176017604008509999232023102310RANGE IN WHICHACCURACY IS SPECIFIEDLOW SCALE HIGH SCALE40000-50-50400400-200-200-1999000182085076012001200176017604006009999232023102310TYPICAL ACCURACYAT 30 °C(°C / EU)± 3± 1± 1± 1± 1± 2± 2± 1± 0.3± 5 EU± 3± 3± 3WORST CASEACCURACY(°C / EU)± 5± 3± 3± 3± 3± 5± 5± 3± 1.0± 20 EU± 5± 5± 5CONNECTION DIAGRAMORDERING INFORMATIONEXT SSR*+XSSRY+V/Iout13 14- FACTORY OPTION*NO1 C1 NC15 4 3X YD+ RELAY2*11NO2 XRS48512D C2 Y10 9 8*CJCFOR 2-WIRETRANSMITTERWITH EXTERNALSUPPLY, USEmA INPUT*RELAY1+B'+*2-WIRETRX9 13FOR 2-WIRETRANSMITTERUSING INTERNALSUPPLY*mAInput85~265VAC/DCS2V1RELAY3 *13X NO314YC37 62-WIRERTD :B A SHORTmV/VIN*7 & 8+ +STK-712A0001020304051.2.3.ORDER CODE2006RelayOptionAnalog outputSupply voltageInput typeAConfigurationRS4854~20 mAoutput0 0 00 0 1222001010111Ordering OptionsThe following ordering options are available on request.Minimum order quantity and/or minimum order value may apply.Details0~10 V DC24 V DCGroup 2Note 1 : Transmitter supply can be given only ifRelay 3 / Analog o/p is absent.Note 2 : For supply voltage = 24 VDC, Relay 3 cannot be provided.AN ISO 9001:2008 COMPANYINSTRUMENTS T : + 91 22 42537777 x 701 F : + 91 22 42537700 E : sales@radix.co.inSENSORS T : + 91 22 42537777 x 732 F : + 91 22 42537700 E : sensors@radix.co.inGAUGES T : + 91 22 42537777 x 733 F : + 91 22 42537700 E : gauges@radix.co.inAUTOMATION C : 0-9322405471 C : 0-9324319150 E : automation@radix.co.inRadix Electrosystems Pvt Ltd, B-14, 2nd Floor, Ghanshyam Indl Estate, Veera Desai Road, Andheri (West), Mumbai - 400 053, IndiaTel : + 91 22 42537777 Fax : + 91 22 42537700 Email : sales@radix.co.in www.radix.co.inSALES INQUIRIES1800-22-radix1800-22-7234www.radix.co.inCAT#179R5/P2/2/300611/A

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!